[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1113970":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1113970,787,2,"多选题","关于阀门的安装要求，正确的说法有（）。2013",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","截止阀门安装时应按介质流向确定其安装方向",true,{"key":16,"text":17,"correct":14},"B","阀门与管道以螺纹方式连接时，阀门应处于关闭状态",{"key":19,"text":20,"correct":21},"C","阀门与管道以焊接连接时，阀门应处于关闭状态",false,{"key":23,"text":24,"correct":14},"D","闸阀与管道以法兰方式连接时，阀门应处于关闭状态",{"key":26,"text":27,"correct":21},"E","安全阀应水平安装以方便操作","ABD","(1）阀门安装前，应按设计文件核对其型号，并应按介质流向确定其安装方向；检查阀门填料，其压盖螺栓应留有调节余量。(2）当阀门与金属管道以法兰或螺纹方式连接时，阀门应在关闭状态下安装；以焊接方式连接时，阀门应在开启状态下安装，对接焊缝底层宜采用氧弧焊。当非金属管道采用电熔连接或热熔连接时，接头附近的阀门应处于开启状态。(3）安全阀安装应垂直安装；安全阀的出口管道应接向安全地点：在安全阀的进出管道上设置截止阀时，应加铅封，且应锁定在全开启状态。",{"id":6,"name":31,"category":32,"favorite":33},"二建机电工程实务","建筑工程",0]