[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1113799":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1113799,787,2,"多选题","通向室外的排水管，穿过墙壁或基础必须下翻时，应采用的连接方式是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","90°斜四通",false,{"key":16,"text":17,"correct":18},"B","45°三通",true,{"key":20,"text":21,"correct":18},"C","45°弯头",{"key":23,"text":24,"correct":14},"D","90°斜三通",{"key":26,"text":27,"correct":14},"E","45°四通","BC","2020版教材P132 本题考查的是建筑管道施工技术要点。通向室外的排水管，穿过墙壁或基础必须下翻时，应采用45°三通和45°弯头连接，并应在垂直管段顶部设置清扫口；通向室外排水检查井的排水管，井内引入管应高于排出管或两管顶相平，并有不小于90°的水流转角，如跌落差大于300mm可不受角度限制。用于室内排水的水平管道与水平管道、水平管道与立管的连接要求：应采用45°三通或45°四通和90°斜三通或90°斜四通。立管与排出管端部的连接，应采用两个45°弯头或曲率半径不小于4倍管径的90°弯头。",{"id":6,"name":31,"category":32,"favorite":33},"二建机电工程实务","建筑工程",0]