[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1113743":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1113743,787,2,"多选题","风管系统制作的一般要求包括（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","复合风管板材的覆面材料必须为不燃材料",true,{"key":16,"text":17,"correct":18},"B","风管与配件的制作宜选用电气焊切割",false,{"key":20,"text":21,"correct":14},"C","风管与法兰连接采用铆接或焊接",{"key":23,"text":24,"correct":18},"D","中、低压系统矩形法兰螺栓及铆钉间距不小于150mm",{"key":26,"text":27,"correct":14},"E","板厚大于1.5mm的风管采用电焊、氩弧焊","ACE","2020版教材P147 本题考查的是风管系统的分类与组成。风管与配件的制作宜选用机械加工方式。通常采用现场半机械手工制作、简易风管生产流水线制作、工厂风管自动流水线制作。 一般板厚小于等于1.2mm的金属板材采用咬口连接，咬口连接有单咬口、联合角咬口、转角咬口、按扣式咬口、立咬口等方法。板厚大于1.5mm的风管采用电焊、氩弧焊等方法。风管与法兰连接采用铆接或焊接连接。中、低压系统矩形法兰螺栓及铆钉间距小于等于150mm,高压系统小于等于100mm。",{"id":6,"name":31,"category":32,"favorite":33},"二建机电工程实务","建筑工程",0]