[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1113714":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},1113714,787,2,"多选题","关于照明配电箱的安装技术要求，正确的有（ ）。 A.配电箱内应标明用电回路的名称和功率",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","零线和保护接地线应在汇流排上连接",false,{"key":16,"text":17,"correct":18},"B","每个三相分支回路的电流不宜超过16",true,{"key":20,"text":21,"correct":18},"C","每个单相分支回路的灯具数量不宜超过25个",{"key":23,"text":24,"correct":18},"D","插座为单独回路时的插座数量不宜超过10个","BCD","2020版教材P140 该题主要考察的是：照明配电箱安装技术要求， 原文是1.照明配电箱安装技术要求（1）照明配电箱应安装牢固，配电箱内应标明用电回路名称。（2）照明配电箱内应分别设置零线和保护接地线（PE线）汇流排，零线和保护线应在汇流排上连接，不得绞接。（3）照明配电箱内每一单相分支回路的电流不宜超过16A，灯具数量不宜超过25个。大型建筑组合灯具每一单相回路电流不宜超过25A，光源数量不宜超过60个。⑷插座为单独回路时，数量不宜超过10个。灯具和插座混为一个回路时，其中插座数不宜超过5个。",{"id":6,"name":28,"category":29,"favorite":30},"二建机电工程实务","建筑工程",0]