[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1113635":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1113635,787,2,"多选题","管道系统压力试验（气压）实施要点正确的是（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","应选用干燥洁净的空气做试验",true,{"key":16,"text":17,"correct":14},"B","试验压力应为设计压力的1.15倍",{"key":19,"text":20,"correct":21},"C","真空管道的试验压力应为1.0MPA",false,{"key":23,"text":24,"correct":21},"D","试验时应装有压力泄放装置，其设定压力不得高于试验压力1.15倍",{"key":26,"text":27,"correct":14},"E","应在试验压力下稳压10min，再将压力降至设计压力，以发泡剂检验不泄漏为合格","ABE","2020版教材P83 本题考查的是管道系统试验。承受内压钢管及有色金属管试验压力应为设计压力的1.15倍，真空管道的试验压力应为0.2MPa。试验时应装有压力泄放装置，其设定压力不得高于试验压力1.1倍。试验前，应用空气进行预试验，试验压力宜为0.2MPa。",{"id":6,"name":31,"category":32,"favorite":33},"二建机电工程实务","建筑工程",0]