[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1113606":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1113606,787,2,"多选题","电气的交接试验注意事项包括（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","在高压试验设备和高电压引线周围，应装设遮拦并悬挂警示牌",true,{"key":16,"text":17,"correct":18},"B","不设防护栅时，最小安全距离为0.5m",false,{"key":20,"text":21,"correct":14},"C","高压试验结束后，应对直流试验设备多次放电",{"key":23,"text":24,"correct":18},"D","成套设备应连接一起进行耐压试验",{"key":26,"text":27,"correct":18},"E","断路器的交流耐压试验合闸状态即可","AC","2020版教材P59 本题考查的是电气设备的施工技术要求。进行高电压试验时，操作人员与高电压回路间应具有足够的安全距离。例如：电压等级6～10kV，不设防护栏时，最小安全距离为0.7m。断路器的交流耐压试验应在分、合闸状态下分别进行。成套设备进行耐压试验时，宜将连接在一起的各种设备分离开来单独进行。",{"id":6,"name":31,"category":32,"favorite":33},"二建机电工程实务","建筑工程",0]