[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1113599":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1113599,787,2,"多选题","6kV以上的橡塑电缆，应做（ ）",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","交流耐压试验",true,{"key":16,"text":17,"correct":14},"B","直流耐压试验",{"key":19,"text":20,"correct":21},"C","测量金属屏蔽层电阻",false,{"key":23,"text":24,"correct":21},"D","绝缘油试验",{"key":26,"text":27,"correct":14},"E","泄露电流测量试","ABE","2020版教材P69 电缆封端应严密，并根据要求做绝缘试验。6kV以上的橡塑电缆，应做交流耐压试验和直流耐压试验及泄露电流测试；1KV及以下的橡塑电缆用2500V兆欧表测试绝缘电阻代替耐压试验，电缆绝缘电阻在试验前后无明显变化，并做好记录。",{"id":6,"name":31,"category":32,"favorite":33},"二建机电工程实务","建筑工程",0]