[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1113328":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1113328,787,2,"多选题","下列关于垂直埋设的人工接地体的施工技术要求，正确的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","接地体的连接应搭接焊接",true,{"key":16,"text":17,"correct":18},"B","接地体的顶部距地面不小于0.7m",false,{"key":20,"text":21,"correct":18},"C","垂直接地体的长度一般为2m",{"key":23,"text":24,"correct":18},"D","用作接地体的镀锌圆钢直径为12mm",{"key":26,"text":27,"correct":14},"E","接地体连接应牢固可靠，有足够的机械强度","AE","本题考查的是接地装置的施工技术要求。垂直埋设的金属接地体一般采用镀锌角钢、镀锌钢管、镀锌圆钢等。镀锌钢管的壁厚不小于2.5mm，镀锌角钢的厚度为4mm，镀锌圆钢的直径不小于14mm，垂直接地体的长度一般为2.5m。埋设后接地体的顶部距地面不小于0.6m，为减小相邻接地体的屏蔽效应，接地体的水平间距应不小于5m。水平埋设的接地体通常采用镀锌扁钢、镀锌圆钢等。镀锌扁钢的厚度应小于4mm，截面积不小于100mm2；镀锌圆钢截面积不小于100mm2。",{"id":6,"name":31,"category":32,"favorite":33},"二建机电工程实务","建筑工程",0]