[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1113326":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1113326,787,2,"多选题","关于灯具安装技术要求，不正确的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","灯具安装应牢固，小型灯具可以使用木榫固定",true,{"key":16,"text":17,"correct":18},"B","固定件的承载能力应与电气照明灯具的重量相匹配",false,{"key":20,"text":21,"correct":14},"C","II类灯具的金属外壳必须用铜芯软线与保护导体可靠连接",{"key":23,"text":24,"correct":18},"D","当吊灯灯具重量超过3kg时，应采取预埋吊钩或螺栓固定",{"key":26,"text":27,"correct":14},"E","质量大于10kg的灯具的固定及悬吊装置应按灯具重量的3倍做恒定均布载荷强度试验","ACE","本题考查的是电气照明施工技术要求。灯具安装应牢固可靠，采用预埋吊钩、膨胀螺栓等安装固定，在砌体和混凝土结构上严禁使用木楔、尼龙塞或塑料塞固定。固定件的承载能力应与电气照明灯具的重量相匹配。I类灯具的金属外壳必须用铜芯软线与保护导体可靠连接，连接处应有接地标识。当吊灯灯具重量超过3kg时，应采取预埋吊钩或螺栓固定。质量大于10kg的灯具的固定及悬吊装置应按灯具重量的5倍做恒定均布载荷强度试验，持续时间不得少于15min。",{"id":6,"name":31,"category":32,"favorite":33},"二建机电工程实务","建筑工程",0]