[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1112576":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},1112576,787,1,"单选题","下列耐火喷涂料施工技术要点中，错误的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","采用湿法喷涂",true,{"key":16,"text":17,"correct":18},"B","喷涂方向应垂直于受喷面",false,{"key":20,"text":21,"correct":18},"C","分段连续喷涂",{"key":23,"text":24,"correct":18},"D","一次喷到设计厚度","2020版教材P125 该题主要考察的是：耐火喷涂料施工技术要求，原文是耐火喷涂料施工的主要技术要求1.喷涂料应采用半干法喷涂，喷涂料加入喷涂机之前，应适当加水润湿，并搅拌均匀;2.喷涂时，料和水应均匀连续喷射，喷涂面上不允许出现干料或流淌；3.喷涂方向应垂直于受喷面，喷嘴与喷涂面的距离宜为1~1.5m，喷嘴应不断地进行螺旋式移动，使粗细颗粒分布均匀；4.喷涂应分段连续进行，一次喷到设计厚度，内衬较厚需分层喷涂时，应在前层喷涂料凝结前喷完次层;5.施工中断时，宜将接槎处做成直槎，继续喷涂前应用水润湿；6.喷涂完毕后，应及时开设膨胀缝线，可用1~3mm厚的楔形板压入30~50mm而成。",{"id":6,"name":27,"category":28,"favorite":29},"二建机电工程实务","建筑工程",0]