[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1111535":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1111535,786,2,"多选题","钻孔灌注桩断桩的防治措施有（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","混凝土坍落度要控制在18～22cm",true,{"key":16,"text":17,"correct":18},"B","在灌注过程中，导管的埋置深度一般控制在2.0～4.0m的范围内",false,{"key":20,"text":21,"correct":14},"C","在提拔导管时要通过测量混凝土的灌注深度及已拆下导管的长度，认真计算提拔导管的长度",{"key":23,"text":24,"correct":14},"D","导管使用前，要对导管检漏和抗拉力试验",{"key":26,"text":27,"correct":18},"E","首批混凝土灌注后要能埋住导管","ACD","2020版教材P154 （ 2 ） 认真测量和计算孔深与导管长度，下导管时，底口距孔底的距离控制在25-40cm之间（注意导管口不能埋入沉淀的回淤泥渣中），同时要能保证首批混凝土灌注后能埋住导管至少1.0m。",{"id":6,"name":31,"category":32,"favorite":33},"二建公路工程实务","建筑工程",0]