[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1106082":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},1106082,781,2,"多选题","水下灌注混凝土应符合的要求有（ ）。",[11,15,18,21,24],{"key":12,"text":13,"correct":14},"A","粗集料应为卵石，或级配良好的碎石",true,{"key":16,"text":17,"correct":14},"B","混凝土的含砂率宜为40%～50%",{"key":19,"text":20,"correct":14},"C","当桩孔直径D＜1.5m时，坍落度宜为180～220mm",{"key":22,"text":23,"correct":14},"D","水灰比宜为0.5～0.6",{"key":25,"text":26,"correct":27},"E","水泥的强度等级应不低于42.5MPa，初凝时间不晚于2.5h",false,"ABCD","水下灌注混凝土（导管灌注混凝土）应符合下列要求：①水泥的强度等级应不低于42.5MPa，其初凝时间不早于2.5h。②粗集料应为卵石，或级配良好的碎石。③粗集料最大粒径为37.5mm，且不得大于导管内径的1\u002F8～1\u002F6及钢筋最小净距的1\u002F4。④混凝土的含砂率宜为40%～50%。⑤缓凝外掺剂，只有得到监理工程师的批准，才能采用。⑥抗硫水泥应按图纸说明，或按监理工程师的要求采用。⑦其坍落度当桩孔直径D＜1.5m时，宜为180～220mm；D≥1.5m时，宜为160～200mm，且应充分考虑气温、运距及施工时间的影响导致的坍落度损失。⑧除非监理工程师另有许可，水泥用量应不少于350kg\u002Fm3。⑨水灰比宜为0.5～0.6。",{"id":6,"name":31,"category":32,"favorite":33},"目标控制（交通工程）","建筑工程",0]