[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-757-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":556},{"id":5,"name":6,"category":7,"favorite":8},757,"电气工程师基础专业知识(基础考试)","建筑工程",0,6,50,1066,[13,34,46,54,66,78,90,102,114,121,133,145,157,169,181,193,201,213,225,237,249,261,273,285,297,308,320,332,344,356,368,380,392,404,416,428,439,451,459,471,479,487,494,501,508,516,523,530,542,549],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1036738,1,"单选题","—台水轮发电机的电动势频率为50Hz,磁极数为12，其额定转速nN等于（）r\u002Fmin。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","50",false,{"key":24,"text":25,"correct":22},"B","600",{"key":27,"text":28,"correct":29},"C","500",true,{"key":31,"text":32,"correct":22},"D","250","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1036741,"一台水轮发电机的额定数据为：PN=100MW,UN=13.8kV,cosφN=0.9（滞后）f=50Hz,4O个磁极,Y接法，其额定电流为（）A。",[38,40,42,44],{"key":20,"text":39,"correct":29},"4648.6",{"key":24,"text":41,"correct":22},"4812.3",{"key":27,"text":43,"correct":22},"8051.4",{"key":31,"text":45,"correct":22},"2683.9",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1036742,"如上题所述,该发电机额定运行时的无功功率为（）MVar。 （A）111.11 （B）52.6 （0）50.5 （D）48.4",[50,51,52,53],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":27,"analysis":33},1036744,"如题所述,该发电机的额定转速是（）r\u002Fmin。",[58,60,62,64],{"key":20,"text":59,"correct":22},"75",{"key":24,"text":61,"correct":22},"166.7",{"key":27,"text":63,"correct":29},"150",{"key":31,"text":65,"correct":22},"125",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":20,"analysis":33},1036746,"—台同步电动机的额定数据为：PN=500kW,cosψN=0.8（超前），ηN=95%。该电动机额定运行时从电网吸取的无功功率为（）kVar。",[70,72,74,76],{"key":20,"text":71,"correct":29},"394.74",{"key":24,"text":73,"correct":22},"300.0",{"key":27,"text":75,"correct":22},"375.0",{"key":31,"text":77,"correct":22},"315.79",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":31,"analysis":33},1036748,"同步电机定子旋转磁场具有的特点为（）。",[82,84,86,88],{"key":20,"text":83,"correct":22},"其磁极数和转速与转子相同，但转向可不同",{"key":24,"text":85,"correct":22},"其磁极数和转向与转子相同，但转速可不同",{"key":27,"text":87,"correct":22},"其转速和转向与转子相同，但磁极对数不同",{"key":31,"text":89,"correct":29},"其转速和转向与转子相同，而且磁极对数也相同",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":31,"analysis":33},1036751,"同步发电机带三相对称负载稳定运行时，转子励磁绕组中（）。",[94,96,98,100],{"key":20,"text":95,"correct":22},"感应低频电动势",{"key":24,"text":97,"correct":22},"感应基频电动势",{"key":27,"text":99,"correct":22},"感应直流电动势",{"key":31,"text":101,"correct":29},"不感应电动势",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":27,"analysis":33},1036753,"一台三相同步发电机在对称负载下稳定运行，当电枢电流I与空载电动势E0之间的夹角为-90° ψ 0°时的电枢反应为（）。",[106,108,110,112],{"key":20,"text":107,"correct":22},"直轴助磁电枢反应",{"key":24,"text":109,"correct":22},"既有直轴去磁电枢反应,又有交轴电枢反应",{"key":27,"text":111,"correct":29},"既有直轴助磁电枢反应，又有交轴电枢反应",{"key":31,"text":113,"correct":22},"既有直轴电枢反应（去磁或助磁不确定），又有交轴电枢反应",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":116,"answer":27,"analysis":33},1036755,[117,118,119,120],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":24,"analysis":33},1036757,"同步电抗表征同步电机在三相对称稳定运行时（〉。",[125,127,129,131],{"key":20,"text":126,"correct":22},"电枢反应磁场的一个综合参数",{"key":24,"text":128,"correct":29},"电枢反应磁场和电枢漏磁场的一个综合参数",{"key":27,"text":130,"correct":22},"气隙合成磁场的一个综合参数",{"key":31,"text":132,"correct":22},"励磁场和励磁漏磁场的一个综合参数",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":24,"analysis":33},1036760,"相应于感应电动机的励磁电抗Xm,在同步电机中有（）。",[137,139,141,143],{"key":20,"text":138,"correct":22},"漏电抗",{"key":24,"text":140,"correct":29},"电枢反应电抗",{"key":27,"text":142,"correct":22},"同步电抗",{"key":31,"text":144,"correct":22},"没有相应的电抗与之对应",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":24,"analysis":33},1036763,"并联于无穷大电网的发电机,欲提高其过载能力,应当（）。",[149,151,153,155],{"key":20,"text":150,"correct":22},"减小励磁电流,减小发电机的输出功率",{"key":24,"text":152,"correct":29},"增大励磁电流,减小发电机的输出功率",{"key":27,"text":154,"correct":22},"增大励磁电流,增大发电机的输出功率",{"key":31,"text":156,"correct":22},"减小励磁电流,增大发电机的输出功率",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":31,"analysis":33},1036766,"—台并联于无穷大电网的同步发电机,在电流落后于电压某一相角时，保持原动机输入不变,逐渐减小励磁电流,则电枢电流为（）。",[161,163,165,167],{"key":20,"text":162,"correct":22},"渐大",{"key":24,"text":164,"correct":22},"先增大后减小",{"key":27,"text":166,"correct":22},"渐小",{"key":31,"text":168,"correct":29},"先减小后增大",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":27,"analysis":33},1036769,"并联于无穷大电网的同步发电机,若保持有功功率不变，由过励运行状态变为欠励运行，则其（）。",[173,175,177,179],{"key":20,"text":174,"correct":22},"功率因数角由正变负,功角由大变小",{"key":24,"text":176,"correct":22},"功率因数角由负变正,功角由大变小",{"key":27,"text":178,"correct":29},"功率因数角由正变负，功角由小变大",{"key":31,"text":180,"correct":22},"功率因数角由负变正,功角由小变大",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":31,"analysis":33},1036772,"并联于无穷大电网的同步发电机，若保持电枢电流为额定值,欲使Cosψ=O.8（滞后）变为cosψ（滞后），必须（）。",[185,187,189,191],{"key":20,"text":186,"correct":22},"增加励磁电流，同时增加输入功率",{"key":24,"text":188,"correct":22},"增加励磁电流,同时减小输入功率",{"key":27,"text":190,"correct":22},"减小励磁电流,同时减小输入功率",{"key":31,"text":192,"correct":29},"减小励磁电流，同时增加输入功率",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":20,"analysis":33},1036774,"一用户为800kW，cosψ=0.65（滞后）的感性负载,若用一台三相同步发电机单独供电，则发电机的额定容量为（ （A）1230.77 （13）935.3 （C）1425.86 （D）1521.73",[197,198,199,200],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":27,"analysis":33},1036777,"如上题所述，则发电机的功率因数为（）。",[205,207,209,211],{"key":20,"text":206,"correct":22},"O.85",{"key":24,"text":208,"correct":22},"O.75",{"key":27,"text":210,"correct":29},"O.65",{"key":31,"text":212,"correct":22},"O.55",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":31,"analysis":33},1036780,"对于感应过电压，（）的说法是错误的。",[217,219,221,223],{"key":20,"text":218,"correct":22},"感应过电压的极性与雷电流的极性相反",{"key":24,"text":220,"correct":22},"感应过电压的电磁分量是由于先导通道中的电流所产生的磁场变化而引起",{"key":27,"text":222,"correct":22},"感应过电压的静电分量是由于先导通道中的电荷被中和所引起",{"key":31,"text":224,"correct":29},"线路上的感应过电压只有雷击杆塔塔顶时才会产生",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":20,"analysis":33},1036782,"接地电阻的数值大小与（）因素基本无关。",[229,231,233,235],{"key":20,"text":230,"correct":29},"金属接地体本身的电阻",{"key":24,"text":232,"correct":22},"金属接地体的形状和大小",{"key":27,"text":234,"correct":22},"金属接地体埋入的深度",{"key":31,"text":236,"correct":22},"大地电阻率",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":31,"analysis":33},1036785,"（）的说法是错误的。",[241,243,245,247],{"key":20,"text":242,"correct":22},"人的两脚着地点之间的电位差称为跨步电压",{"key":24,"text":244,"correct":22},"人所站立的地点与接地设备之间的电位差称为接触电压",{"key":27,"text":246,"correct":22},"接地点处的电位与接地电流的比值定义为该点的接地电阻",{"key":31,"text":248,"correct":29},"在有电流流入接地点时,该点的电位与大地的任何一点保持等电位",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":20,"analysis":33},1036787,"ZnO避雷器的续流在（）范围内。",[253,255,257,259],{"key":20,"text":254,"correct":29},"微安级",{"key":24,"text":256,"correct":22},"安培级",{"key":27,"text":258,"correct":22},"几十安培",{"key":31,"text":260,"correct":22},"数百安培级",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":24,"analysis":33},1036790,"ZnO避雷器具有良好的陡波响应特性的原因是其（）。",[265,267,269,271],{"key":20,"text":266,"correct":22},"几乎无续流",{"key":24,"text":268,"correct":29},"无火花间隙",{"key":27,"text":270,"correct":22},"通流容量大",{"key":31,"text":272,"correct":22},"阀片具有极其优异的非线性特性",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":20,"analysis":33},1036793,"ZnO避雷器不具有（）。",[277,279,281,283],{"key":20,"text":278,"correct":29},"灭弧电压参数",{"key":24,"text":280,"correct":22},"残压参数",{"key":27,"text":282,"correct":22},"起始动作电压参数",{"key":31,"text":284,"correct":22},"容许最大持续运行电压参数",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":20,"analysis":33},1036796,"（）能对内部电压施行保护。",[289,291,293,295],{"key":20,"text":290,"correct":29},"ZnO避雷器",{"key":24,"text":292,"correct":22},"SiC避雷器",{"key":27,"text":294,"correct":22},"管式避雷器",{"key":31,"text":296,"correct":22},"间隙",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":20,"analysis":33},1036799,"装设避雷针或避雷线可使设备免受直接雷击,所谓免受是指受雷击的概率小于（）。",[301,303,305,307],{"key":20,"text":302,"correct":29},"0.1%",{"key":24,"text":304,"correct":22},"0.01%",{"key":27,"text":306,"correct":22},"0.2%",{"key":31,"text":306,"correct":22},{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":24,"analysis":33},1036801,"为保护离避雷针22m远的髙为10m的设备,避雷针至少应高于（）m。",[312,314,316,318],{"key":20,"text":313,"correct":22},"22",{"key":24,"text":315,"correct":29},"28",{"key":27,"text":317,"correct":22},"30",{"key":31,"text":319,"correct":22},"26",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":20,"analysis":33},1036804,"为保护离避雷针5m远的髙为20m的设备，独立避雷针的接地电阻应小于（）Ω。",[324,326,328,330],{"key":20,"text":325,"correct":29},"15",{"key":24,"text":327,"correct":22},"8",{"key":27,"text":329,"correct":22},"20",{"key":31,"text":331,"correct":22},"5",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":31,"analysis":33},1036807,"髙压断路器与隔离开关的作用是（）。",[336,338,340,342],{"key":20,"text":337,"correct":22},"断路器切合空载电流,隔离开关切合短路电流",{"key":24,"text":339,"correct":22},"渐铬器切合短路电流，镉离开关切合空载电琉",{"key":27,"text":341,"correct":22},"断路器切合负荷电流，隔离开关切合空载电流",{"key":31,"text":343,"correct":29},"断路器切合短路电流，隔离开关不切合电流",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":24,"analysis":33},1036810,"SF6断路器的特点是（）。",[348,350,352,354],{"key":20,"text":349,"correct":22},"开断性能好，可靠性低",{"key":24,"text":351,"correct":29},"开断性能好,可銪性高",{"key":27,"text":353,"correct":22},"开断性能差,可靠性高",{"key":31,"text":355,"correct":22},"开断性能差,可餚性低",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":27,"analysis":33},1036813,"断路器的额定关合电流是其额定开断电流的倍数为（）。",[360,362,364,366],{"key":20,"text":361,"correct":22},"1.0",{"key":24,"text":363,"correct":22},"1.73",{"key":27,"text":365,"correct":29},"2.55",{"key":31,"text":367,"correct":22},"3.14",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":24,"analysis":33},1036815,"断路器重合闸的无电流间隔时间为（）s。",[372,374,376,378],{"key":20,"text":373,"correct":22},"O.1-0.3",{"key":24,"text":375,"correct":29},"0.3-0.5",{"key":27,"text":377,"correct":22},"O.5-0.7",{"key":31,"text":379,"correct":22},"I.0-3.0",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":27,"analysis":33},1036818,"相同的条件下，SF6气体的灭弧能力大约是空气灭弧能力的（）倍。",[384,386,388,390],{"key":20,"text":385,"correct":22},"2",{"key":24,"text":387,"correct":22},"1O",{"key":27,"text":389,"correct":29},"1OO",{"key":31,"text":391,"correct":22},"1000",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":24,"analysis":33},1036821,"变电所停电时（）。",[396,398,400,402],{"key":20,"text":397,"correct":22},"先拉隔离开关,后切断断路器",{"key":24,"text":399,"correct":29},"先切断断路器,后拉隔离开关",{"key":27,"text":401,"correct":22},"先合隔离开关，后合断路器",{"key":31,"text":403,"correct":22},"先合断路器,后合隔离开关",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":20,"analysis":33},1036824,"真空断路器与少油断路器相比，其开断距离（）。",[408,410,412,414],{"key":20,"text":409,"correct":29},"小",{"key":24,"text":411,"correct":22},"大",{"key":27,"text":413,"correct":22},"相等",{"key":31,"text":415,"correct":22},"差不多",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":27,"analysis":33},1036827,"压缩空气断路器，压缩空气作为（）。",[420,422,424,426],{"key":20,"text":421,"correct":22},"灭弧介质和绝缘介质,油作为操作动力",{"key":24,"text":423,"correct":22},"只是灭弧介质",{"key":27,"text":425,"correct":29},"同时作为灭弧介质、绝缘介质的操作动力",{"key":31,"text":427,"correct":22},"只作为绝缘介质",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":20,"analysis":33},1036829,"断路器重燃弧的熄灭，要求弧隙介质强度的恢复比弧隙电压的恢复（）。",[432,434,436,437],{"key":20,"text":433,"correct":29},"快",{"key":24,"text":435,"correct":22},"慢",{"key":27,"text":413,"correct":22},{"key":31,"text":438,"correct":22},"相近",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":31,"analysis":33},1036832,"SF6全封闭组合电器不包括（）。",[443,445,447,449],{"key":20,"text":444,"correct":22},"隔离开关",{"key":24,"text":446,"correct":22},"互感器",{"key":27,"text":448,"correct":22},"避雷器",{"key":31,"text":450,"correct":29},"变压器",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":24,"analysis":33},1036835,"下列（）为导体长期工作的温升曲线。",[455,456,457,458],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":31,"analysis":33},1036838,"短路故障通常会对设备产生（）主要影响。",[463,465,467,469],{"key":20,"text":464,"correct":22},"劣化、磁化",{"key":24,"text":466,"correct":22},"发热、老化",{"key":27,"text":468,"correct":22},"发热、增加接触电阻",{"key":31,"text":470,"correct":29},"发热、受力",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":24,"analysis":33},1036841,"下列（）截面形状布置的导体集肤效应系数较小。",[475,476,477,478],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":31,"analysis":33},1036843,"下列（）曲线描述了导体的经济电流密度与最大负荷利用小时数的关系。",[483,484,485,486],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":489,"answer":27,"analysis":33},1036846,[490,491,492,493],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":496,"answer":24,"analysis":33},1036849,[497,498,499,500],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":503,"answer":31,"analysis":33},1036852,[504,505,506,507],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":33},1036855,"某双绕组变压器的额定容量为15000kVA,额定变比为121\u002F10.5kV,△P0=20",[512,513,514,515],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":518,"answer":20,"analysis":33},1036858,[519,520,521,522],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":525,"answer":27,"analysis":33},1036860,[526,527,528,529],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":20,"analysis":33},1036863,"一条阻抗为10+j_3011的110kV线路,取基准功率SB=100MVA,基准电压为各级平均额定电压，那么该线路阻抗的标幺值为（）。",[534,536,538,540],{"key":20,"text":535,"correct":29},"0.0756+j0.2268",{"key":24,"text":537,"correct":22},"0.0634+j0.1902",{"key":27,"text":539,"correct":22},"0.0936+j0.2808",{"key":31,"text":541,"correct":22},"0.123+j0.369",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":544,"answer":31,"analysis":33},1036866,[545,546,547,548],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":551,"answer":24,"analysis":33},1036868,[552,553,554,555],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},[557,560,563,566,569,572],{"id":15,"name":558,"category":7,"favorite":559},"领导干部任职前廉政法规知识测试题",92,{"id":561,"name":562,"category":7,"favorite":15},595,"建筑结构与设备",{"id":564,"name":565,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":567,"name":568,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":570,"name":571,"category":7,"favorite":8},534,"BIM工程师",{"id":573,"name":571,"category":7,"favorite":8},535]