[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-757-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":576},{"id":5,"name":6,"category":7,"favorite":8},757,"电气工程师基础专业知识(基础考试)","建筑工程",0,4,50,1066,[13,34,46,58,66,78,90,102,114,122,134,146,158,170,180,192,204,216,228,236,248,256,268,280,292,304,316,327,339,351,358,370,382,390,398,410,420,428,440,451,463,475,487,499,511,523,535,545,557,568],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1036487,1,"单选题","按照国家技术标准规定，计算变压器的性能时,对绕阻电阻的温度要换算到（）数值。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","40℃",false,{"key":24,"text":25,"correct":22},"B","55℃",{"key":27,"text":28,"correct":22},"C","65℃",{"key":30,"text":31,"correct":32},"D","75℃",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1036491,"变压器利用电磁感应作用实现电压变换的根本方法是（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"—次与二次绕组的匝数相同",{"key":24,"text":41,"correct":32},"—次与二次绕组的匝数不同",{"key":27,"text":43,"correct":22},"一次与二次绕组有电的联系",{"key":30,"text":45,"correct":22},"—次与二次绕组互相绝缘",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},1036494,"上题图为一台单相变压器示意图,其额定电压U1N\u002FU2N=220\u002F110V。现将X与a两端用导线连接，在 A、x之间加电压U=330V，则变压器的主磁通与空载时的主磁通相比较为（）。",[50,52,54,56],{"key":20,"text":51,"correct":32},"不变",{"key":24,"text":53,"correct":22},"变大",{"key":27,"text":55,"correct":22},"变小",{"key":30,"text":57,"correct":22},"不确定",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1036498,"—台单相变压器的额定电压U1N\u002FU2N=220\u002F110V,如题4-87图所示,将X与x两端用导线连接,在 A、a之间加电压U=110V,则变压器的主磁通与空载时的主磁通相比较为（）。",[62,63,64,65],{"key":20,"text":51,"correct":32},{"key":24,"text":53,"correct":22},{"key":27,"text":55,"correct":22},{"key":30,"text":57,"correct":22},{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":30,"analysis":33},1036502,"变压器一次绕组漏电抗X1；是与交链一次绕组（）相对应的参数。",[70,72,74,76],{"key":20,"text":71,"correct":22},"总磁通",{"key":24,"text":73,"correct":22},"磁通",{"key":27,"text":75,"correct":22},"主磁通",{"key":30,"text":77,"correct":32},"漏磁通",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":27,"analysis":33},1036505,"变压器励磁电阻Rm的物理意义是反映变压器（）的一个等效电阻。",[82,84,86,88],{"key":20,"text":83,"correct":22},"总损耗",{"key":24,"text":85,"correct":22},"短路损耗",{"key":27,"text":87,"correct":32},"铁芯损耗",{"key":30,"text":89,"correct":22},"二次绕组损耗",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":27,"analysis":33},1036508,"一台单相变压器的额定容量SN=100kVA,额定电压U1N\u002FU2N=6\u002F0.23kV,—次绕组电阻与漏抗为R1,=4.32Ω、X1=8.9二次绕组电阻与漏抗为R2=0.006Ω、X2=0.013Ω。利用简化等效电路求得额定电压下的稳态短路电流为（）A。",[94,96,98,100],{"key":20,"text":95,"correct":22},"606.06",{"key":24,"text":97,"correct":22},"584.51",{"key":27,"text":99,"correct":32},"306.59",{"key":30,"text":101,"correct":22},"250.58",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":30,"analysis":33},1036511,"影响变压器的电压调整率的所有可能的因素是（）。",[106,108,110,112],{"key":20,"text":107,"correct":22},"漏阻抗和励磁阻抗",{"key":24,"text":109,"correct":22},"励磁阻抗和负载大小",{"key":27,"text":111,"correct":22},"负载大小和性质以及励磁阻抗",{"key":30,"text":113,"correct":32},"漏阻抗及负载大小和性质",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":30,"analysis":33},1036514,"—台Y\u002F△—11连接的三相变压器,其额定容饿SN=5600kVA,额定电压U1N\u002FU2N=35\u002F6.3kV,短路电阻Rk=2.07短路电抗Xk=16.2Ω，当带纯电阻负载在额定情况下运行时,其电压调整率△U%为（）。 （A）0.55% （8）0.315% （0）1.65% （D）0.95%",[118,119,120,121],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":32},{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":24,"analysis":33},1036517,"—台Y\u002FYn-0连接的三相变压器,其额定容量SN=320kVA,额定电压U1N\u002FU2N=6.3\u002F0.4kV,短路损耗PkN=5.5kW,阻抗电压Uk=4.5%，当带纯电感负载在额定情况下运行时,其电压调整率为（）。",[126,128,130,132],{"key":20,"text":127,"correct":22},"4.39%",{"key":24,"text":129,"correct":32},"4.15%",{"key":27,"text":131,"correct":22},"3.38%",{"key":30,"text":133,"correct":22},"2.75%",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":30,"analysis":33},1036519,"变压器空载合闸时不产生冲击电流的电压初相角α0为（）。",[138,140,142,144],{"key":20,"text":139,"correct":22},"0",{"key":24,"text":141,"correct":22},"π\u002F6",{"key":27,"text":143,"correct":22},"π\u002F3",{"key":30,"text":145,"correct":32},"π\u002F2",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":20,"analysis":33},1036521,"变压器做空载试验时，在一、二次侧分别进行，并且都加额定电压，则两种情况下分别测得的铁耗是（）。",[150,152,154,156],{"key":20,"text":151,"correct":32},"相等",{"key":24,"text":153,"correct":22},"不相等",{"key":27,"text":155,"correct":22},"—次侧测得铁耗大",{"key":30,"text":157,"correct":22},"二次侧测得铁耗大",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":20,"analysis":33},1036524,"—台三相变压器的额定容量SN=100kV，额定电压U1N\u002FU2N=6\u002F0.4kV,空载损耗P0=0.616kW,短路损耗PkN=1.92kW,当变压器运行在额定状态,且负载的功率因数cosφ2=0.8时，该变压器的效率为（）。",[162,164,166,168],{"key":20,"text":163,"correct":32},"O.969",{"key":24,"text":165,"correct":22},"O.948",{"key":27,"text":167,"correct":22},"O.931",{"key":30,"text":169,"correct":22},"O.924",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":20,"analysis":33},1036526,"当变压器的负载增大时,其铁耗为（）。",[174,175,177,179],{"key":20,"text":51,"correct":32},{"key":24,"text":176,"correct":22},"增大",{"key":27,"text":178,"correct":22},"减小",{"key":30,"text":57,"correct":22},{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":24,"analysis":33},1036527,"一台三相变压器的额定容狱SN=1000kV A，额定电压U1N\u002FU2N=10\u002F6.3kV，空载损耗P0=4.9kW,短路损耗PkN=15kW,当变压器带纯电阻负载在额定情况下运行时,其最高效率为为（）。",[184,186,188,190],{"key":20,"text":185,"correct":22},"O.990",{"key":24,"text":187,"correct":32},"O.983",{"key":27,"text":189,"correct":22},"O.977",{"key":30,"text":191,"correct":22},"O.971",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":30,"analysis":33},1036530,"三相组式变压器不采用Y\u002FY连接的原因是（）。",[196,198,200,202],{"key":20,"text":197,"correct":22},"—、二次绕组的线电动势为尖顶波",{"key":24,"text":199,"correct":22},"空载电流为尖顶波",{"key":27,"text":201,"correct":22},"主磁通为尖顶波",{"key":30,"text":203,"correct":32},"—二次绕组的相电动势为尖顶波",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":24,"analysis":33},1036534,"Y\u002FA连接组既适用于相组式变压器，也适用于三相芯式变压器，原因是（）。",[208,210,212,214],{"key":20,"text":209,"correct":22},"—、二次绕组的线电动势为正弦形",{"key":24,"text":211,"correct":32},"—、二次绕组的相电动势为正弦形",{"key":27,"text":213,"correct":22},"空载电流为正弦形",{"key":30,"text":215,"correct":22},"主磁通为尖顶波形",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":24,"analysis":33},1036537,"一台单相变压器额定电压U1N\u002FU2N=220\u002F110V，出厂前进行极性试验，接线图如题4-101图所示，将X与X两端用导线连接,在 A、X两端加额定电压U1N=220V,测 A、a两端电压。如果 A、a两端为同极性,则 A、a两端电压为（）V。",[220,222,224,226],{"key":20,"text":221,"correct":22},"220",{"key":24,"text":223,"correct":32},"110",{"key":27,"text":225,"correct":22},"O",{"key":30,"text":227,"correct":22},"330",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":27,"analysis":33},1036540,"一台三相感应电动机的额定频率f=50Hz，额定转速nN=2900r\u002Fmin，其额定转差率SN为（）。 （A）0.013 （B）0.034 （C）0.033 （0）0.043",[232,233,234,235],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":22},{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":27,"analysis":33},1036543,"—台绕线式感应电动机,定子绕组通入三相交流电流,旋转磁场逆时针方向旋转,转子绕組开路，此时电动机将会（）。",[240,242,244,246],{"key":20,"text":241,"correct":22},"逆时针方向旋转",{"key":24,"text":243,"correct":22},"顺时针方向旋转",{"key":27,"text":245,"correct":32},"不动",{"key":30,"text":247,"correct":22},"摆动",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":20,"analysis":33},1036546,"一台绕线型感应电动机，将定子三相绕组短接，转子三相绕组通入三相交流电流，转子旋转磁场逆时针方向旋转,此时电动机将会（）。",[252,253,254,255],{"key":20,"text":243,"correct":32},{"key":24,"text":241,"correct":22},{"key":27,"text":245,"correct":22},{"key":30,"text":247,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":30,"analysis":33},1036548,"—台三相感应电动机，额定数据为：额定功率PN=4.5kW,额定电压UN=380V,额定功率因数cosφN=0.8，额定效率Th=0.8，额定转速nN=1450r\u002Fmin，Y形接线，则额定电流为（）A。",[260,262,264,266],{"key":20,"text":261,"correct":22},"14.80",{"key":24,"text":263,"correct":22},"18.50",{"key":27,"text":265,"correct":22},"8.54",{"key":30,"text":267,"correct":32},"10.68",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":24,"analysis":33},1036552,"如上题所给数据,该电机的额定转差率SN为（）。",[272,274,276,278],{"key":20,"text":273,"correct":22},"0.034",{"key":24,"text":275,"correct":32},"0.033",{"key":27,"text":277,"correct":22},"0.023",{"key":30,"text":279,"correct":22},"O.013",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":30,"analysis":33},1036555,"三相感应电动机等值电路中的电阻（上消耗的功率为（）。",[284,286,288,290],{"key":20,"text":285,"correct":22},"轴上输出机械功率",{"key":24,"text":287,"correct":22},"电磁功率",{"key":27,"text":289,"correct":22},"输入功率",{"key":30,"text":291,"correct":32},"总机械功率",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":20,"analysis":33},1036559,"一台三相4级感应电动机,在某一运行情况下，电动机从电源输入功率为6kW,定子铜耗PCu1=300W,铁耗PFe=150W,转子铜耗PCu2=200W，机械损耗=50W,附加损耗Pad=30W,电源频率f=50Hz。则该电机的电磁功率为（）kW。",[296,298,300,302],{"key":20,"text":297,"correct":32},"5.55",{"key":24,"text":299,"correct":22},"5.56",{"key":27,"text":301,"correct":22},"5.57",{"key":30,"text":303,"correct":22},"5.35",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":30,"analysis":33},1036560,"如题4-108所给数据,该电机的电磁转矩为（）N?m。",[308,310,312,314],{"key":20,"text":309,"correct":22},"34.06",{"key":24,"text":311,"correct":22},"35.97",{"key":27,"text":313,"correct":22},"35.46",{"key":30,"text":315,"correct":32},"35.34",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":30,"analysis":33},1036564,"如题4-108所给数据，该电机的轴上输出转矩（即负载转矩）T2为（）N?M。",[320,322,324,325],{"key":20,"text":321,"correct":22},"33.48",{"key":24,"text":323,"correct":22},"34.94",{"key":27,"text":313,"correct":22},{"key":30,"text":326,"correct":32},"34.82",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":24,"analysis":33},1036567,"一台三相6极感应电动机的额定数据为：PN=7.5kW,UN=380V,f=50Hz,cosΦN=0.824,=960r\u002Fmin，定子为△接法。额定运行时的各项损耗为：PCu1=474W,PFe=231W,Pmcc=45W,Pad=38W。则该电机额定运行时的效率ηN为（）。",[331,333,335,337],{"key":20,"text":332,"correct":22},"O.82",{"key":24,"text":334,"correct":32},"O.87",{"key":27,"text":336,"correct":22},"O.90",{"key":30,"text":338,"correct":22},"O.92",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":30,"analysis":33},1036569,"如上题所给数据，则该电机额定运行时的电流IN为（）A。",[343,345,347,349],{"key":20,"text":344,"correct":22},"13.83",{"key":24,"text":346,"correct":22},"27.48",{"key":27,"text":348,"correct":22},"23.95",{"key":30,"text":350,"correct":32},"15.87",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":353,"answer":20,"analysis":33},1036572,[354,355,356,357],{"key":20,"text":20,"correct":32},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},1036575,"如上题所给数据,该电机额定运行时的空载转矩T0为（）N?m。",[362,364,366,368],{"key":20,"text":363,"correct":22},"8.50",{"key":24,"text":365,"correct":32},"7.24",{"key":27,"text":367,"correct":22},"6.83",{"key":30,"text":369,"correct":22},"7.00",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":20,"analysis":33},1036579,"三相感应电动机启动时,所带负载越大,其启动电流是（）。",[374,376,378,380],{"key":20,"text":375,"correct":32},"与负载大小无关",{"key":24,"text":377,"correct":22},"与负载大小有关",{"key":27,"text":379,"correct":22},"越大",{"key":30,"text":381,"correct":22},"越小",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":24,"analysis":33},1036581,"一台三相感应电动机的额定电压UN=220V,定子三相绕组为△接法。启动时将定子绕组改为Y接法，并接在380V的交流电源上，则电机的启动电流与接在220V电源上仍为△接法直接启动时相比较,则Y接法的启动电流比△接法的启动电流（）。",[386,387,388,389],{"key":20,"text":176,"correct":22},{"key":24,"text":178,"correct":32},{"key":27,"text":51,"correct":22},{"key":30,"text":57,"correct":22},{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":27,"analysis":33},1036584,"如上题所述，则电机的启动转矩（）。",[394,395,396,397],{"key":20,"text":176,"correct":22},{"key":24,"text":178,"correct":22},{"key":27,"text":51,"correct":32},{"key":30,"text":57,"correct":22},{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":20,"analysis":33},1036587,"—台三相感应电动机在额足情况下运行，当忽略空载转矩后，则电磁转矩T与额定转矩TN相等，即T=TN。在负载不变的情况下，当电源电压下降10%，稳定运行后，电机的电磁转矩为（）。",[402,404,406,408],{"key":20,"text":403,"correct":32},"T=TN",{"key":24,"text":405,"correct":22},"T TN",{"key":27,"text":407,"correct":22},"T=O.81TN",{"key":30,"text":409,"correct":22},"T=O.90TN",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":27,"analysis":33},1036591,"如上题所述，电机的最大转矩（）。",[414,415,416,418],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":22},{"key":27,"text":417,"correct":32},"Tm降至额定电压时的81%",{"key":30,"text":419,"correct":22},"Tm降至额定电压时的90%",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":27,"analysis":33},1036593,"将三相感应电动机的转子电阻增大一倍,则最大电磁转矩将会（）。",[424,425,426,427],{"key":20,"text":176,"correct":22},{"key":24,"text":178,"correct":22},{"key":27,"text":51,"correct":32},{"key":30,"text":57,"correct":22},{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":20,"analysis":33},1036597,"互感器运行时，要求其二次侧（）。",[432,434,436,438],{"key":20,"text":433,"correct":32},"电压互感器开路，电流互感器短路",{"key":24,"text":435,"correct":22},"电压互感器短路,电流互感器短路",{"key":27,"text":437,"correct":22},"电压互感器短路,电流互感器开路",{"key":30,"text":439,"correct":22},"电压互感器开路，电流互感器开路",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":20,"analysis":33},1036601,"电压互感器二次侧额定电压一般为（）V。",[444,446,447,449],{"key":20,"text":445,"correct":32},"1OO",{"key":24,"text":221,"correct":22},{"key":27,"text":448,"correct":22},"380",{"key":30,"text":450,"correct":22},"5",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":27,"analysis":33},1036604,"电流互感器不完全星形接线时,测世电压的相别为（）。",[455,457,459,461],{"key":20,"text":456,"correct":22},"a、b",{"key":24,"text":458,"correct":22},"b、c",{"key":27,"text":460,"correct":32},"a、c",{"key":30,"text":462,"correct":22},"b",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":27,"analysis":33},1036607,"电流互感器二次侧负荷主要包括（）。",[467,469,471,473],{"key":20,"text":468,"correct":22},"仪器仪表的阻抗",{"key":24,"text":470,"correct":22},"连接电缆的阻抗",{"key":27,"text":472,"correct":32},"仪器仪表和电缆的阻抗",{"key":30,"text":474,"correct":22},"仪器仪表、电缆与变压器阻抗",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":30,"analysis":33},1036609,"电压互感器二次侧开口三角的作用是（）。",[479,481,483,485],{"key":20,"text":480,"correct":22},"测世三相电压",{"key":24,"text":482,"correct":22},"测量线电压",{"key":27,"text":484,"correct":22},"监视相序",{"key":30,"text":486,"correct":32},"测量零序电压",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":30,"analysis":33},1036612,"电压互感器与电流互感器一次侧接入电力系统的方式是（）。",[491,493,495,497],{"key":20,"text":492,"correct":22},"串接、串接",{"key":24,"text":494,"correct":22},"并接、并接",{"key":27,"text":496,"correct":22},"串接、并接",{"key":30,"text":498,"correct":32},"并接、串接",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":24,"analysis":33},1036616,"电压互感器配置原则为（）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"每段主母线和旁路母线都接一组电压互感器",{"key":24,"text":506,"correct":32},"主母线接互感器、旁路母线不接",{"key":27,"text":508,"correct":22},"主母线接互感器、旁路母线视情况而定",{"key":30,"text":510,"correct":22},"主母线与旁路母线都视情况决定是否接",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":24,"analysis":33},1036618,"互感器二次侧接地属于（）。",[515,517,519,521],{"key":20,"text":516,"correct":22},"工作接地",{"key":24,"text":518,"correct":32},"保护接地",{"key":27,"text":520,"correct":22},"安全接地",{"key":30,"text":522,"correct":22},"防雷接地",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":30,"analysis":33},1036622,"电流互感器的容量通常表示为（）。",[527,529,531,533],{"key":20,"text":528,"correct":22},"电流",{"key":24,"text":530,"correct":22},"电压",{"key":27,"text":532,"correct":22},"VA",{"key":30,"text":534,"correct":32},"阻抗",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":20,"analysis":33},1036625,"电压互感器一次侧接高压熔断器的合适电压等级为（）kV。",[539,541,542,543],{"key":20,"text":540,"correct":32},"35",{"key":24,"text":223,"correct":22},{"key":27,"text":221,"correct":22},{"key":30,"text":544,"correct":22},"500",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":24,"analysis":33},1036629,"直流电机的电枢电动势表达式中的磁通是指（）。",[549,551,553,555],{"key":20,"text":550,"correct":22},"空载时的每极磁通",{"key":24,"text":552,"correct":32},"负载时的每极磁通",{"key":27,"text":554,"correct":22},"空载时所有磁极磁通的总知",{"key":30,"text":556,"correct":22},"负载时所有磁极磁通的总和",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":20,"analysis":33},1036631,"如果他励直流发电机的转速上升20%,则空载时发电机的端电压升高（）。",[561,563,565,567],{"key":20,"text":562,"correct":32},"20%",{"key":24,"text":564,"correct":22},"大于20%",{"key":27,"text":566,"correct":22},"小于20%",{"key":30,"text":51,"correct":22},{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":24,"analysis":33},1036633,"如果并励直流发电机的转速上升20%，则空载时发电机的端电压升高（）。",[572,573,574,575],{"key":20,"text":562,"correct":22},{"key":24,"text":564,"correct":32},{"key":27,"text":566,"correct":22},{"key":30,"text":51,"correct":22},[577,580,583,586,589,592],{"id":15,"name":578,"category":7,"favorite":579},"领导干部任职前廉政法规知识测试题",92,{"id":581,"name":582,"category":7,"favorite":15},595,"建筑结构与设备",{"id":584,"name":585,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":587,"name":588,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":590,"name":591,"category":7,"favorite":8},534,"BIM工程师",{"id":593,"name":591,"category":7,"favorite":8},535]