[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":541},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,7,50,2321,[13,34,46,58,70,78,88,100,108,120,130,142,154,166,174,186,194,202,210,218,230,238,246,254,262,274,285,297,309,319,327,339,347,359,371,381,393,405,413,425,433,441,453,465,477,485,497,505,517,529],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1031274,1,"单选题","35kV及以下的电力电缆，在不易有经常性开挖的地段、较易翻修的城镇人行道下 或道路边缘，同一通路的电缆根数少于（）根可用直埋方式敷设。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","6；",true,{"key":24,"text":25,"correct":26},"B","8；",false,{"key":28,"text":29,"correct":26},"C","10；",{"key":31,"text":32,"correct":26},"D","12。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1031277,"室内变电所的每台油量为（ ）及以上的三相变压器，应设在单独的变压器室内。",[38,40,42,44],{"key":20,"text":39,"correct":22},"100kg；",{"key":24,"text":41,"correct":26},"70kg；",{"key":28,"text":43,"correct":26},"90kg;",{"key":31,"text":45,"correct":26},"50kg",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1031279,"在同一配电室内单列布置髙、低压配电装置时，当髙压开关柜或低压配电屏顶面有 裸露带电导体时，两者之间的净距不应小于（ ）。当高压开关柜和低压配电屏的顶面封闭 外壳防护等级符合IP2X级时可靠近布置。",[50,52,54,56],{"key":20,"text":51,"correct":26},"0. 8m；",{"key":24,"text":53,"correct":22},"2.0m;",{"key":28,"text":55,"correct":26},"1.5m;",{"key":31,"text":57,"correct":26},"1.0m。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1031282,"变电所宜单层布置。当采用双层布置时，变压器应设在（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"远离变电所5m处；",{"key":24,"text":65,"correct":26},"远离变电所10m处",{"key":28,"text":67,"correct":22},"底层（",{"key":31,"text":69,"correct":26},"二层。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},1031285,"当电缆线路与地下管网交叉不多，地下水位较低、无高温介质溢出可能的地区，同 —路径的高压电力电缆根数一般不宜超过（ ）根时可采用电缆沟敷设。当髙、低压电缆在 同一沟内敷设时根数可适当增加。 A. 18; B 20; C. 22; D. 12。",[74,75,76,77],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":28,"analysis":33},1031288,"一般正常情况下，同一路径高压电力电缆根数在（ ）根以上时可采用电缆隧道敷 设。在特殊情况下，电缆根数虽少，也可以采用电缆隧道敷设。",[82,83,84,86],{"key":20,"text":25,"correct":26},{"key":24,"text":29,"correct":26},{"key":28,"text":85,"correct":22},"15；",{"key":31,"text":87,"correct":26},"6。",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":31,"analysis":33},1031291,"电缆穿保护管敷设时，保护管的内径不宜小于电缆外径或多根电缆包络外径的 ()倍。",[92,94,96,98],{"key":20,"text":93,"correct":26},"1.0;",{"key":24,"text":95,"correct":26},"1.1;",{"key":28,"text":97,"correct":26},"1.2；",{"key":31,"text":99,"correct":22},"1.5。",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":31,"analysis":33},1031293,"6kV或10kV屋外无遮拦裸导体至地面的安全净距应不小于（ )。 A. 2000mm； B 2300mm； C 2500mm； D. 2700mm",[104,105,106,107],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":31,"analysis":33},1031296,"小于的母排引出线至屋外人行通道地面的最小电气安全净距应不小 于（ ）。",[112,114,116,118],{"key":20,"text":113,"correct":26},"2700mm；",{"key":24,"text":115,"correct":26},"3000mm；",{"key":28,"text":117,"correct":26},"3300mm；",{"key":31,"text":119,"correct":22},"3650mm。",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":31,"analysis":33},1031299,"3~35kV屋内配电装置通向屋外的出线套管至屋外人行通道路面的安全净距应不小 于（ ）。",[124,125,126,128],{"key":20,"text":113,"correct":26},{"key":24,"text":115,"correct":26},{"key":28,"text":127,"correct":26},"3650mm；",{"key":31,"text":129,"correct":22},"4000mm。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},1031301,"成套电容器柜单列布置时，柜正面与墙面的距离不应小于1.5m;当双列布置时, 柜面之间最小距离应不小于（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"1. 5m；",{"key":24,"text":137,"correct":26},"1.6m;",{"key":28,"text":139,"correct":22},"2. Om；",{"key":31,"text":141,"correct":26},"1.9m。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},1031304,"电缆沟与工业水管、沟交叉时，应使电缆沟位于工业水管沟的（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"上方；",{"key":24,"text":149,"correct":26},"下方；",{"key":28,"text":151,"correct":26},"左方；",{"key":31,"text":153,"correct":26},"右方。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},1031307,"3~63kV屋内或屋外配电装置中，同一电压等级的不同相带电部分之间的安全净距 ( )带电部分至接地部分之间的安全净距。",[158,160,162,164],{"key":20,"text":159,"correct":26},"不等于；",{"key":24,"text":161,"correct":22},"等于；",{"key":28,"text":163,"correct":26},"大于；",{"key":31,"text":165,"correct":26},"小于。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},1031309,"llOkV中性点非有效接地系统屋外配电装置中，其相对相与相对地的安全净距不一 样，不同相的带电部分之间的安全净距比带电部分至接地部分之间的安全净距大（）。 A. 25%； B. 15%; C 10%； D. 5%。",[170,171,172,173],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":20,"analysis":33},1031312,"长度大于（ ）的10kV及以下的配电室应设两个出口，并宜布置在配电室的两 端，长度大于60m时宜增加一个出口。",[178,180,182,184],{"key":20,"text":179,"correct":22},"7m；",{"key":24,"text":181,"correct":26},"15m；",{"key":28,"text":183,"correct":26},"10m；",{"key":31,"text":185,"correct":26},"20m。",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":24,"analysis":33},1031315,"lOkV及以下的露天或半露天变电所的变压器四周应设不低于（ ）的固定围栏 (墙)。 A. 1.2m; R. 1.7m; C. 1.6m; D. 1.5m。",[190,191,192,193],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":28,"analysis":33},1031317,"lOkV及以下露天或半露天变电所的变压器外廓与围栏（墙）的净距应不小 于（ ）。 A. 0.5m; B 0. 6m; C. 0.8m; D. 0.7。",[198,199,200,201],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":31,"analysis":33},1031320,"lOkV及以下变电所中的1250kVA及以上可燃油油浸变压器外廓与变压器室后壁、 侧壁的最小净距应不小于（ ）。 A. 500mm; B. 600mm； C 700mm； D. 800mm",[206,207,208,209],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":31,"analysis":33},1031323,"lOkV及以下露天或半露天变压器供给一级负荷用电时，相邻的可燃油油浸变压器 的防火净距应不小于（ ）。若小于该值时应设防火墙。 A. 3m; B4m； C. 4.8m； D. 5m",[214,215,216,217],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":28,"analysis":33},1031325,"lOkV及以下变电所的100~1000kVA可燃油油浸变压器外廓与变压器室门的最小 净距应不小于（ ）。",[222,224,226,228],{"key":20,"text":223,"correct":26},"500mm",{"key":24,"text":225,"correct":26},"600mm",{"key":28,"text":227,"correct":22},"800rnm",{"key":31,"text":229,"correct":26},"700mm",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":24,"analysis":33},1031328,"lOkV及以下配电装置的长度大于（ ）时，其柜（屏）后通道应设两个出口，低 压配电装置两个出口间的距离超过15m时应增加出口。 A. 10m; B 6m； C. 7m； D. 8m。",[234,235,236,237],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},1031331,"10kV及以下高压配电室内当开关柜单排布置时，其柜后维护通道的最小宽度应不 小于（ ）。 A. 800mm； B 600mm； C 700mm ； D. 500mm。",[242,243,244,245],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":31,"analysis":33},1031333,"当屋外油浸变压器之间的距离不满足防火净距要求时应设置防火墙。考虑散热问 题，防火墙离变压器外廓距离以不小于（ ）为宜. A. 0. 5m； B. 1. Om； C 1. 5m； D. 2.0m。",[250,251,252,253],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":28,"analysis":33},1031336,"lOkV及以下高压配电室内，当开关柜双排背对背布置、柜后通道仅作维护用时,其柜后维护通道的最小宽度应不小于（） A. 600mm； B 700mm； C. 1000mm； D. 800mm。",[258,259,260,261],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":31,"analysis":33},1031339,"lOkV及以下高压配电室内，当固定式开关柜单排布置时，其柜前操作通道最小宽 度应不小于（ )。",[266,268,270,272],{"key":20,"text":267,"correct":26},"1000mm；",{"key":24,"text":269,"correct":26},"1200mm;",{"key":28,"text":271,"correct":26},"1400mm；",{"key":31,"text":273,"correct":22},"1500mm。",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":28,"analysis":33},1031342,"lOkV及以下高压配电室内，当固定式开关柜双排背对背布置时，其柜前操作通道 最小宽度应不小于（ ）。",[278,279,281,283],{"key":20,"text":267,"correct":26},{"key":24,"text":280,"correct":26},"1200mm",{"key":28,"text":282,"correct":22},"1500mm;",{"key":31,"text":284,"correct":26},"1400mm",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":24,"analysis":33},1031344,"lOkV及以下高压配电室内，当手车式开关柜单排布置时，其柜前操作通道最小宽 度应不小于（ )",[289,291,293,295],{"key":20,"text":290,"correct":26},"单车长度+900mm;",{"key":24,"text":292,"correct":22},"单车长度+1200mm;",{"key":28,"text":294,"correct":26},"单车长度+1100mm;",{"key":31,"text":296,"correct":26},"单车长度+1000mm。",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":20,"analysis":33},1031347,"lOkV及以下高压配电室内，当手车式开关柜双排面对面布置时，其柜前操作通道 最小宽度应不小于（ ）。",[301,303,305,307],{"key":20,"text":302,"correct":22},"双车长庋+900mm;",{"key":24,"text":304,"correct":26},"双车长度+700mm;",{"key":28,"text":306,"correct":26},"C双车长度+800tnm;",{"key":31,"text":308,"correct":26},"双车长度+600mm。",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":24,"analysis":33},1031350,"低压配电室内的固定式配电屏单排布置或双排面对面布置、屏后通道仅作维护用 时，其屏后通道的最小宽度应不小于（ ）。",[313,314,315,317],{"key":20,"text":229,"correct":26},{"key":24,"text":267,"correct":22},{"key":28,"text":316,"correct":26},"900mm；",{"key":31,"text":318,"correct":26},"800mm。",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":31,"analysis":33},1031352,"独立避雷针及其接地装置与道路或建筑物的出、人口等的距离应大于（ ），否则 应采取均压措施或铺设砾石、卵石和沥混凝土路面。 A. 1. Om B1. 5m； C. 2. Om； D. 3. Om。",[323,324,325,326],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":20,"analysis":33},1031355,"独立避雷针的接地装置与接地网的地中距离不应小于（ ），当不能满足时，可以采用沥青或沥青混凝土作为绝绝隔离层。",[331,333,335,337],{"key":20,"text":332,"correct":22},"3m；",{"key":24,"text":334,"correct":26},"5m；",{"key":28,"text":336,"correct":26},"6m；",{"key":31,"text":338,"correct":26},"10m。",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":33},1031358,"避雷针或避雷线的构架上的照明电源线，必须采用直埋于地下的带金属护层的电缆 或穿人金属管的绝缘导线，电缆的金属外皮护层或金属管必须接地，埋地长度应在（ ）以 上，方可与35kV及以下配电装置的接地网及低压配电装置的接地网相连。 A. 8m； B. 10m； C 6m D. 5m。",[343,344,345,346],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":28,"analysis":33},1031361,"低压配电室内的固定式配电屏双排背对背布置时，其屏后通道的最小宽度应不小",[351,353,355,357],{"key":20,"text":352,"correct":26},"于（ ）。",{"key":24,"text":354,"correct":26},"1200mm；",{"key":28,"text":356,"correct":22},"1300mm; C 1500mm;",{"key":31,"text":358,"correct":26},"1400mm。",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":31,"analysis":33},1031363,"低压配电室内的抽屉式配电屏，当单排布置或双排面对面布置或双排背对背布置 时，其屏后通道最小宽度应不小于（ ）。",[363,365,367,369],{"key":20,"text":364,"correct":26},"700mm{",{"key":24,"text":366,"correct":26},"800mmf",{"key":28,"text":368,"correct":26},"900mm",{"key":31,"text":370,"correct":22},"1000mm",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":31,"analysis":33},1031365,"低压配电室内的固定式配电屏，当单排布置或双排背对背布置时，其屏前通道的最 小宽度应不小于（ ）。",[375,376,378,380],{"key":20,"text":269,"correct":26},{"key":24,"text":377,"correct":26},"1300mm;",{"key":28,"text":379,"correct":26},"1400mm;",{"key":31,"text":273,"correct":22},{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":28,"analysis":33},1031368,"低压配电室内的固定式配电屏，当双排面对面布置时，其屏前通道最小宽度应不小 于（ ）。",[385,387,389,391],{"key":20,"text":386,"correct":26},"1600mm；",{"key":24,"text":388,"correct":26},"1800mm;",{"key":28,"text":390,"correct":22},"2000mm;",{"key":31,"text":392,"correct":26},"1900mm。",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":24,"analysis":33},1031371,"低压配电室内的抽屉式配电屏，当单排布置或双排背对背布置时，其屏前通道最小 宽度应不小于（ ）。",[397,399,401,403],{"key":20,"text":398,"correct":26},"1550mm；",{"key":24,"text":400,"correct":22},"1800mm；",{"key":28,"text":402,"correct":26},"1750mm;",{"key":31,"text":404,"correct":26},"1650mm。",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":28,"analysis":33},1031374,"低压配电室内的抽屉式配电屏，当双排面对面布置时，其屏前通道的最小宽度应不 小于（ ）。 A. 2000mm； B 2100mm； C. 2300mm； D. 2200mm。",[409,410,411,412],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":31,"analysis":33},1031377,"埋地敷设在严寒地区的电缆应埋设于冻土层以下，当无法深埋时，可在土壤排水性 好的干燥冻土层或回填土中埋设，也可采取防止电缆受损伤的其他措施或在电缆的上方和下 方增加细砂层的厚度，上下方各增加的厚度不宜小于（ ）。",[417,419,421,423],{"key":20,"text":418,"correct":26},"100mm;",{"key":24,"text":420,"correct":26},"150mm;",{"key":28,"text":422,"correct":26},"180mm;",{"key":31,"text":424,"correct":22},"200mm。",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":31,"analysis":33},1031380,"变电所建筑物室内地面标高宜（ ），并根据地质条件考虑沉降量 A.与屋外地面相同； B低于屋外地面； C高出屋外地面0~50mm; D.高出屋外地面150~300mm。",[429,430,431,432],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":31,"analysis":33},1031382,"35kV及以下的直埋电力电缆与地下压力水管、自流水管、压缩空气管之间最小水 平净距应不小于（ ）。 A. 0. 6m B 0.8m; C 0.9m; D. 1.0m。",[437,438,439,440],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":31,"analysis":33},1031385,"35kV及以下的直埋电力电缆与地下热力管（未采取隔热措施时）或热力管沟之间 最小水平净距应不小于（ ）。",[445,447,449,451],{"key":20,"text":446,"correct":26},"1. 6m;",{"key":24,"text":448,"correct":26},"1. 7m；",{"key":28,"text":450,"correct":26},"1. 8m;",{"key":31,"text":452,"correct":22},"2. Om。",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":20,"analysis":33},1031387,"35kV及以下的直埋电力电缆与地下通信电缆之间最小水平净距应不小于（ ）。",[457,459,461,463],{"key":20,"text":458,"correct":22},"0.5m;",{"key":24,"text":460,"correct":26},"0.3m;",{"key":28,"text":462,"correct":26},"0.4m;",{"key":31,"text":464,"correct":26},"0.1m。",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":24,"analysis":33},1031390,"35kV及以下的直埋电力电缆与地下压力水管、自流水管、热力管、压缩空气管、 事故排油管、明沟沟底相互交叉的最小垂直净距应不小于（ ）",[469,471,473,475],{"key":20,"text":470,"correct":26},"0. 2m；",{"key":24,"text":472,"correct":22},"0. 5m;",{"key":28,"text":474,"correct":26},"0. 4m;",{"key":31,"text":476,"correct":26},"0. 3m。",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":28,"analysis":33},1031393,"同型号的抽屉式低压配电屏，当布置不受（场地〉限制且屏后通道仅作维护用时, 双排背对背布置的配电室最小宽度比双排面对面布置的（ ）。 A.小； B小2个配电屏的深度； C.大； D.相等。",[481,482,483,484],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":31,"analysis":33},1031396,"同型号的低压配电屏，不论是固定式的还是抽屉式的，当布置不受（场地）限制 时，双排面对面布置的配电室最小宽度比双排背对背布置的（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":26},"相等；",{"key":24,"text":492,"correct":26},"大一个配电屏的深度；",{"key":28,"text":494,"correct":26},"大；",{"key":31,"text":496,"correct":22},"小。",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":31,"analysis":33},1031399,"35kV及以下的直埋电力电缆与道路相互交叉时，道路路面与电缆间的最小垂直净 距应不小于（ ）。 A. 0.5m; B 0.8m; C. 0. 9m； D. 1.0m。",[501,502,503,504],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":20,"analysis":33},1031400,"设计llOkV屋外配电装置及选择导体和电器时的最大风速，可采用离地（ ）高、 ( )一遇lOmin平均最大风速。",[509,511,513,515],{"key":20,"text":510,"correct":22},"10m, 30 年；",{"key":24,"text":512,"correct":26},"15m, 30 年；",{"key":28,"text":514,"correct":26},"10m, 50 年；",{"key":31,"text":516,"correct":26},"15m, 50 年。",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":24,"analysis":33},1031403,"3~llOkV屋外配电装置中，当电气设备外绝缘体最低部位距地面小于（ ）时应装设固定遮栏。",[521,523,525,527],{"key":20,"text":522,"correct":26},"2. 8m；",{"key":24,"text":524,"correct":22},"2. 5m；",{"key":28,"text":526,"correct":26},"3m",{"key":31,"text":528,"correct":26},"4m",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":20,"analysis":33},1031406,"3~llOkV配电装置中相邻带电部分不是同一额定电压等级时，应按（ ）确定其 电气安全净距。",[533,535,537,539],{"key":20,"text":534,"correct":22},"较高等级的额定电压；",{"key":24,"text":536,"correct":26},"较高等级的额定电压净距与较低等级的额定电压净距之和的一半；",{"key":28,"text":538,"correct":26},"较低等级的额定电压；",{"key":31,"text":540,"correct":26},"较高等级额定电压净距与较低等级额定电压净距之差的一半。",[542,545,548,551,554,557],{"id":15,"name":543,"category":7,"favorite":544},"领导干部任职前廉政法规知识测试题",92,{"id":546,"name":547,"category":7,"favorite":15},595,"建筑结构与设备",{"id":549,"name":550,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":552,"name":553,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":555,"name":556,"category":7,"favorite":8},534,"BIM工程师",{"id":558,"name":556,"category":7,"favorite":8},535]