[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":536},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,6,50,2321,[13,30,38,46,58,66,74,86,98,109,121,133,141,149,156,168,180,192,204,216,228,236,243,250,257,265,277,289,300,312,324,336,344,356,368,380,388,400,412,424,436,448,460,472,480,488,496,504,516,524],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":23,"analysis":29},1031146,1,"单选题","负荷无功功率的大幅度快速变化，主要影响电能质量指标中的（） A.电压不平衡度； B电压波动和闪变； C.波形； D.频率，",[19,22,25,27],{"key":20,"text":20,"correct":21},"A",false,{"key":23,"text":23,"correct":24},"B",true,{"key":26,"text":26,"correct":21},"C",{"key":28,"text":28,"correct":21},"D","",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":32,"options":33,"answer":28,"analysis":29},1031149,"三相不平衡负荷（含单相负荷）主要影响电能质量指标中的（ ）。 A.频率； B电压波动和闪变； C.波形； D.电压不平衡度。",[34,35,36,37],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":28,"analysis":29},1031151,"负荷的非线性，主要影响电能质量指标中的（ )。 A.电压不平衡度；B 电压偏移； C电压波动和闪变； D.波形畸变。",[42,43,44,45],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":23,"analysis":29},1031153,"三相电力系统中，三相电压不平衡度的定义是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":21},"电压零序分量与正序分量的方均根值百分比；",{"key":23,"text":53,"correct":24},"电压负序分量与正序分量的方均根值百分比；",{"key":26,"text":55,"correct":21},"电压零序分量与额定电压的方均根值百分比；",{"key":28,"text":57,"correct":21},"三相电压差值的最大值与额定电压的百分比。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":29},1031155,"电力系统公共连接点正常电压不平衡度的允许值为（）。 A. 0.5%, B 1.0%； C 1. 5%； D. 2%。",[62,63,64,65],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":23,"analysis":29},1031157,"接于公共连接点的每个用户，引起该点正常电压不平衡度的允许值一般为（）。 A. 0.5% B 1.3%； C 2% D. 2.5%。",[70,71,72,73],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":20,"analysis":29},1031159,"GB 12326—2000《电能质量电压波动和闪变》规定的公共连接点（PC C)是指 ()",[78,80,82,84],{"key":20,"text":79,"correct":24},"电力系统中一个以上用户的连接处；",{"key":23,"text":81,"correct":21},"企业专用总变电所向所属各车间供电的母线处；",{"key":26,"text":83,"correct":21},"C车间变电所向所属各工段供电的母线处；",{"key":28,"text":85,"correct":21},"动力配电箱向各设备供电的母线处。",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":20,"analysis":29},1031161,"由波动负荷在电力系统公共连接点产生的电压变动限值，与公共连接点的（ ） 有关。",[90,92,94,96],{"key":20,"text":91,"correct":24},"电压等级和电压变动频度；",{"key":23,"text":93,"correct":21},"短路容量；",{"key":26,"text":95,"correct":21},"C供电能力；",{"key":28,"text":97,"correct":21},"电压偏差，",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":23,"analysis":29},1031163,"电力系统公共连接点由波动负荷产生的闪变限值，与公共连接点的（）有关。",[102,103,105,107],{"key":20,"text":93,"correct":21},{"key":23,"text":104,"correct":24},"电压等级；",{"key":26,"text":106,"correct":21},"供电能力；",{"key":28,"text":108,"correct":21},"电压总谐波畸变率。",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":26,"analysis":29},1031164,"按GB 12326—2000《电能质量电压波动和闪变》规定，闪变限值有两种：“电力 系统公共连接点闪变限值（简称PCC限值)”和“任何一个波动负荷在电力系统公共连接点 单独引起的闪变限值（简称_个用户限制）”。这两种限值的关系是（ ）。",[113,115,117,119],{"key":20,"text":114,"correct":21},"两种限值在数量上是相同的；",{"key":23,"text":116,"correct":21},"两种限值在数量上是不相同的，但用户只要符合其中的任一种限值即可；",{"key":26,"text":118,"correct":24},"应根据PCC限值，按一定算法扣去背景值，再根据该用户协议用电容量与PCC供 电能力之比，按一定算法求出该用户的单个用户限制；",{"key":28,"text":120,"correct":21},"应根据PCC限值，不考虑背景值影响，再根据该用户波动负荷容量与PCC供电能 力之比，按一定算法求出该用户的单个用户限值。",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":28,"analysis":29},1031166,"按GB 12326—2000《电能质量电压波动和闪变》规定，长时间闪变值P11的每 次测量周期为（ ）。",[125,127,129,131],{"key":20,"text":126,"correct":21},"lOmin；",{"key":23,"text":128,"correct":21},"50min",{"key":26,"text":130,"correct":21},"lh；",{"key":28,"text":132,"correct":24},"2h。",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":26,"analysis":29},1031168,"计算电压变动和闪变值，应选取电力系统正常运行的较小方式下的短路容量为依 据。无法取得该短路容量的数据时，可选取用户项目投产时系统最大短路容量乘以系数 ()进行计算。 A. 0.9; B. 0.8； C 0.7； D. 0.6。",[137,138,139,140],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":28,"analysis":29},1031171,"当用户供电电压大于35kV时，不经闪变核算就可直接入电网的条件是：公共连 接点短路容量与波动负荷视在功率的变动量之比为（ ）以上。 A. 80； B120； C. 500； D. 1000,",[145,146,147,148],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":151,"answer":23,"analysis":29},1031174,[152,153,154,155],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":23,"analysis":29},1031177,"电力系统正常频率偏差的允许值为（）。",[160,162,164,166],{"key":20,"text":161,"correct":21},"士0.1Hz;",{"key":23,"text":163,"correct":24},"土0.2Hz;",{"key":26,"text":165,"correct":21},"±0. 3Hz;",{"key":28,"text":167,"correct":21},"±0. 4Hz。",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":20,"analysis":29},1031180,"电力系统正常频率偏差的允许值，当系统容量较小时可以放宽到（ ）",[172,174,176,178],{"key":20,"text":173,"correct":24},"士0.5Hz;",{"key":23,"text":175,"correct":21},"±1.0Hz;",{"key":26,"text":177,"correct":21},"±1. 5Hz;",{"key":28,"text":179,"correct":21},"±2. 0Hz。",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":23,"analysis":29},1031181,"用户冲击负荷引起的系统频率变动一般不得超过（ ），根据冲击负荷性质和 大小以及系统的条件也可适当变动限值，但应保证近区电力网、发电机组和用户的安全、稳 定运行和供电。",[184,186,188,190],{"key":20,"text":185,"correct":21},"±0.1;",{"key":23,"text":187,"correct":24},"±0.2;",{"key":26,"text":189,"correct":21},"±0.5;",{"key":28,"text":191,"correct":21},"士 1.0,",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":23,"analysis":29},1031184,"电力系统频率偏差的定义是（ ）。",[196,198,200,202],{"key":20,"text":197,"correct":21},"实际最大值与实际最小值之差；",{"key":23,"text":199,"correct":24},"B实际值和标称值之差，有名值；",{"key":26,"text":201,"correct":21},"实际最大值与实际最小值之差，以标称值的百分数表示；",{"key":28,"text":203,"correct":21},"实际最大值与平均值之差。",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":28,"analysis":29},1031187,"谐波含有率（HR)是指（ ）。",[208,210,212,214],{"key":20,"text":209,"correct":21},"对周期性交流量进行傅里叶分解，得到频率为基波频率的整流倍（大于1)的分量",{"key":23,"text":211,"correct":21},"B从周期性交流量中减去基波分量所得的量；",{"key":26,"text":213,"correct":21},"谐波频率与基波频率的整数比；",{"key":28,"text":215,"correct":24},"周期性交流量中含有的第h次谐波分量的方均根值与基波分量的方均根值之比（用 百分数表示）",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":20,"analysis":29},1031190,"总谐波畸变率（TH D)是指（ ）。 A.周期性交流量中的谐波含量的方均根值与其基波分量的方均根值之比（用百分数表",[220,222,224,226],{"key":20,"text":221,"correct":24},"示）；",{"key":23,"text":223,"correct":21},"从周期性交流量t减去基波分量所得的量；",{"key":26,"text":225,"correct":21},"对周期性交流量进行傅里叶分解，得到频率为基波频率的整数倍（大于1)的分量；",{"key":28,"text":227,"correct":21},"周期性交流量的方均根值。",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":23,"analysis":29},1031193,"对快速变化的负荷，评定谐波所进行的测量结果，可取（ ）内所测值的平均 值，且此期间内均匀间隔的测量次数应不小于（ ）。 A. Is, 2 次； R 3s, 6 次； C 5s, 8 次； D. 8s, 10 次",[232,233,234,235],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":238,"answer":20,"analysis":29},1031195,[239,240,241,242],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":245,"answer":23,"analysis":29},1031198,[246,247,248,249],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":252,"answer":26,"analysis":29},1031201,[253,254,255,256],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":20,"analysis":29},1031204,"根据我国电能质量国家标准，标称电压为380V公用电网电压总谐波畸变率限值 为（），各奇次谐波电压含有率限值为（），各偶次谐波电压含有率限值为（）。 A. 5%, 4%，2%； B 5%, 2%, 4% C. 2%, 4%, 5%； D. 3%,1.2% 2.4%.",[261,262,263,264],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":20,"analysis":29},1031206,"如将同一标称电压的三种谐波电压限值，按从大到小排列，正确的顺序应 是（ ）。 A.电压总谐波畸变率限值，奇次谐波电压含有率限值，偶次谐波电压含有率限值；",[269,271,273,275],{"key":20,"text":270,"correct":24},"偶次谐波电压含有率限值，奇次谐波电压含有率限值，电压总谐波畸变率限值；",{"key":23,"text":272,"correct":21},"偶次谐波电压畸变率限值，电压总谐波畸变率限值，奇次谐波电压含有率限值；",{"key":26,"text":274,"correct":21},"奇次谐波电压含有率限值，偶次谐波畸变率限值，电压总谐波畸变率限值。",{"key":28,"text":276,"correct":21},"提示：（1)偶次谐波有点类似于负序分量，其对电网和用户的危害，更甚于奇次谐波。",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":23,"analysis":29},1031209,"116.按我国电能质量国家标准，标称电压为35kV公用电网电压总谐波畸变率限值为 ( ),各奇次谐波电压含有率限值为（ ），各偶次谐波电压含有率限值为（ ）.",[281,283,285,287],{"key":20,"text":282,"correct":21},"3%，1.2%, 2.4%；",{"key":23,"text":284,"correct":24},"3%, 2.4%； 1.2%；",{"key":26,"text":286,"correct":21},"5%, 4%, 2%；",{"key":28,"text":288,"correct":21},"1%, 1.2%； 2.4%。",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":26,"analysis":29},1031212,"应急电源的工作时间，应按生产技术上要求的停车时间考虑。当与自启动的发电 机组配合使用时，不宜少于（ ）。",[293,295,297,298],{"key":20,"text":294,"correct":21},"20min",{"key":23,"text":296,"correct":21},"15min；",{"key":26,"text":126,"correct":24},{"key":28,"text":299,"correct":21},"5min",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":23,"analysis":29},1031214,"电压损失的定义是（ ）。",[304,306,308,310],{"key":20,"text":305,"correct":21},"受端电压与送端电压相量的几何差；",{"key":23,"text":307,"correct":24},"B受端电压与送端电压的代数差；",{"key":26,"text":309,"correct":21},"受端电压与网络标称电压的代数差；",{"key":28,"text":311,"correct":21},"送端电压与网络标称电压的代数差。",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":28,"analysis":29},1031217,"在配电线路受端加装并联电容器以减少线路电压损失，其适用的情况是（ ）",[316,318,320,322],{"key":20,"text":317,"correct":21},"受端负荷的自然功率因数很高；",{"key":23,"text":319,"correct":21},"配电线路的感性电抗很小；",{"key":26,"text":321,"correct":21},"C配电线路的感性电抗虽然很大，但受端负荷的自然功率因数已接近于1.0;",{"key":28,"text":323,"correct":24},"受端负荷的自然功率因数低，而配电线路的感性电抗又很大，",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":26,"analysis":29},1031218,"选择并联电容器装置回路的电器和导体时要注意，其稳定过电流应取为电容器额 定电流的（ ）倍。",[328,330,332,334],{"key":20,"text":329,"correct":21},"1. 1；",{"key":23,"text":331,"correct":21},"1.2；",{"key":26,"text":333,"correct":24},"1.35；",{"key":28,"text":335,"correct":21},"1.5。",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":26,"analysis":29},1031221,".不规则、随机性波动负荷（如炼钢电弧炉）引起的电压波动频率r可取为（ ）。",[340,341,342,343],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":20,"analysis":29},1031224,"在TN-C系统中，PEN线（保护中性线）上装设开关设备的规定是（）。",[348,350,352,354],{"key":20,"text":349,"correct":24},"PEN线严禁接入开关设备；",{"key":23,"text":351,"correct":21},"PEN线应接入开关设备；",{"key":26,"text":353,"correct":21},"需要时，PEN线可接入开关设备；",{"key":28,"text":355,"correct":21},"PEN线允许接入开关设备。",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":26,"analysis":29},1031226,"当装设漏电电流动作的保护时，应能将其所保护的回路所有带电导线断开，但对 于TN系统，N线开断与否的规定是（ ）。",[360,362,364,366],{"key":20,"text":361,"correct":21},"无条件，必需开断N线；",{"key":23,"text":363,"correct":21},"无条件，禁止开断N线；",{"key":26,"text":365,"correct":24},"当能可靠保持N线为地电位时，N线可不开断；",{"key":28,"text":367,"correct":21},"当能可靠保持N线为地电位时，N线也必须开断。",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":23,"analysis":29},1031229,"除用电设备容量较大、负荷集中、选用更大容量变压器更经济合理的情况外，变 电所中单台变压器（低压为0.4kV)的容量不宜大于( )。",[372,374,376,378],{"key":20,"text":373,"correct":21},"1600kVA;",{"key":23,"text":375,"correct":24},"1250kVA；",{"key":26,"text":377,"correct":21},"lOOOkVA；",{"key":28,"text":379,"correct":21},"800kV",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":26,"analysis":29},1031232,"带可燃性油的高压配电装置宜装在单独的高压配电室内，当高压开关柜的数量为 ( )台及以下时，可与低压配电屏布置在同一房间内。 A. 10； B. 8; C 6; D. 5。",[384,385,386,387],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":23,"analysis":29},1031235,"设置于10kV及以下变电所的非封闭式干式变压器，当多台干式变压器在一起设置 时，变压器之间的净距不小于（ ）。",[392,394,396,398],{"key":20,"text":393,"correct":21},"2m；",{"key":23,"text":395,"correct":24},"lm；",{"key":26,"text":397,"correct":21},"0.8m;",{"key":28,"text":399,"correct":21},"0.6m.",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":20,"analysis":29},1031238,"供给一级负荷供电的两路电缆不应通过同一电缆沟或电缆隧道，当无法分开时，该 电缆沟或电缆隧道内的两路电缆应采用阻燃性电缆且分别置于电缆通道两侧支架上，两路电 缆应保持大于（ ）的距离。",[404,406,408,410],{"key":20,"text":405,"correct":24},"400mm；",{"key":23,"text":407,"correct":21},"300mm;",{"key":26,"text":409,"correct":21},"250mm；",{"key":28,"text":411,"correct":21},"200mm.",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":23,"analysis":29},1031241,"为了人身和设备的安全，10kV及以下的露天变电所的变压器四周应设固定围栏 (墙），其高度不低于（ ）.",[416,418,420,422],{"key":20,"text":417,"correct":21},"1. 4m；",{"key":23,"text":419,"correct":24},"1. 7m；",{"key":26,"text":421,"correct":21},"1. 6m；",{"key":28,"text":423,"correct":21},"1. 5m",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":26,"analysis":29},1031244,"lOkV及以下高压配电装置室，当电源从柜（屏）后进线且需在柜（屏）正背后墙上 另设隔离开关及其手动操动机构时，柜（屏）后通道净宽不应小于（ ）。",[428,430,432,434],{"key":20,"text":429,"correct":21},"2.0m;",{"key":23,"text":431,"correct":21},"1. 8m；",{"key":26,"text":433,"correct":24},"1.5m;",{"key":28,"text":435,"correct":21},"1. 3m",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":28,"analysis":29},1031247,"lOkV及以下高压配电室内的柜后维护通道或柜前操作通道宽度，在建筑物的墙面遇 有柱类局部凸出时，凸出部位的通道宽度比规范要求的宽度可减小（ ）。",[440,442,444,446],{"key":20,"text":441,"correct":21},"500mm;",{"key":23,"text":443,"correct":21},"400mm,",{"key":26,"text":445,"correct":21},"300mm；",{"key":28,"text":447,"correct":24},"200mm。",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":23,"analysis":29},1031249,"民用主体建筑内的附设变电所和车间内变电所的可燃油浸变压器室，应设置容量为 ( )变压器油量的贮油池。",[452,454,456,458],{"key":20,"text":453,"correct":21},"50%;",{"key":23,"text":455,"correct":24},"100%；",{"key":26,"text":457,"correct":21},"80%；",{"key":28,"text":459,"correct":21},"20%.",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":26,"analysis":29},1031251,"附设变电所或露天变电所中，油量为（）及以上的变压器，应设置容量为100%变 压器油量的挡油设施。",[464,466,468,470],{"key":20,"text":465,"correct":21},"1500kg；",{"key":23,"text":467,"correct":21},"1200kg；",{"key":26,"text":469,"correct":24},"1000kg;",{"key":28,"text":471,"correct":21},"800kg。",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":28,"analysis":29},1031255,"在10kV及以下配电室内裸导体正上方不应布置灯具和明敷线路。当在配电室内裸 导体上方布置灯具时，灯具与裸导体的水平净距不应小于（），灯具不得采用吊链和软线 吊装。 A. 2. 0m； B1. 8m; C 1. 5m; D. 1. Om.",[476,477,478,479],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":23,"analysis":29},1031258,"标称电压超过交流25V (方均根值）容易被触及的裸导体（但无防止进水造成有害影响）必须设置遮护物或外罩，其防护等级不应低于GB 4208—1984《外壳防护等级分类》的（ )级。 A.IP1X; BIP2X； C.IP31； D.IP32。",[484,485,486,487],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":26,"analysis":29},1031260,"500V及以下的裸带电体布置在有人活动的上方，裸带电体与地面或平台的垂直净 距不应小于（ )。 A. 3. Om； B 2. 8m； C 2.5m; D. 2.0m。",[492,493,494,495],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":28,"analysis":29},1031263,"在工业企业厂房内，500V及以下的裸导体与需经常维护的管道（可燃气体及易燃、 易爆液体管道除外）同侧敷设时：裸导体应敷设在管道的上面，其净距不应小于（ ），当 其净距小于或等于该值时应加遮护。 A. 1. 2m； B 1.5m; C. 1.6m; D. 1.8m。",[500,501,502,503],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":26,"analysis":29},1031265,"放置11OkV全封闭组合电器楼面的均布活荷载标准值为（ ）。",[508,510,512,514],{"key":20,"text":509,"correct":21},"80kN\u002Fm2；",{"key":23,"text":511,"correct":21},"9. OkN\u002Fm2,",{"key":26,"text":513,"correct":24},"10. OkN\u002Fm2,",{"key":28,"text":515,"correct":21},"7. OkN\u002Fm2.",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":20,"analysis":29},1031268,"屋内3、6、lOkV配电装置开关室楼面活荷载标准值为4.0~7.OkN\u002Fm2，该值是在 每组开关质量为（ ）时适用。 A.≤8kN; B≤9kN； C. 10kN； D. ≤12kN。",[520,521,522,523],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":28,"analysis":29},1031271,"高压电容器室的长度超过（ ）时应设两个出口，门应向外开。",[528,530,532,534],{"key":20,"text":529,"correct":21},"15m；",{"key":23,"text":531,"correct":21},"12m；",{"key":26,"text":533,"correct":21},"10m;",{"key":28,"text":535,"correct":24},"7m。",[537,540,543,546,549,552],{"id":15,"name":538,"category":7,"favorite":539},"领导干部任职前廉政法规知识测试题",92,{"id":541,"name":542,"category":7,"favorite":15},595,"建筑结构与设备",{"id":544,"name":545,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":547,"name":548,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":550,"name":551,"category":7,"favorite":8},534,"BIM工程师",{"id":553,"name":551,"category":7,"favorite":8},535]