[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":528},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,5,50,2321,[13,30,38,50,62,73,85,97,105,117,125,137,149,157,169,181,189,197,209,221,229,237,245,253,261,273,284,292,300,308,320,328,339,351,363,371,381,393,401,413,421,433,441,453,461,473,485,497,509,520],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":29},1031027,1,"单选题","当配电变压器变压比为10(6)±5%\u002F0.4kV时，如将分接头放在一5%,低压侧电压提升率以标称电压0.38kV表示，应约为（ ）。 A. -5%； B 土0%; C. +5%； D. +10?.",[19,22,24,26],{"key":20,"text":20,"correct":21},"A",false,{"key":23,"text":23,"correct":21},"B",{"key":25,"text":25,"correct":21},"C",{"key":27,"text":27,"correct":28},"D",true,"",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":32,"options":33,"answer":23,"analysis":29},1031030,"端电压偏差对异步电动机的影响之一是：起动转矩和最大转矩按端电压的（ ）次 方增减。 A. 1； B 2； C. 3； D. 4。",[34,35,36,37],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":23,"analysis":29},1031033,"端电压偏差对同步电动机的影响之一是：起动转矩按端电压的（ ）次方增减。",[42,44,46,48],{"key":20,"text":43,"correct":21},"1；",{"key":23,"text":45,"correct":28},"2；",{"key":25,"text":47,"correct":21},"3；",{"key":27,"text":49,"correct":21},"4,",{"id":51,"libraryId":5,"type":15,"typeLabel":16,"stem":52,"options":53,"answer":25,"analysis":29},1031035,"白炽灯的光通量，约与其端电压的（ ）次方成正比。",[54,56,58,60],{"key":20,"text":55,"correct":21},"-1；",{"key":23,"text":57,"correct":21},"—2. 5;",{"key":25,"text":59,"correct":28},"+3.6；",{"key":27,"text":61,"correct":21},"-5.",{"id":63,"libraryId":5,"type":15,"typeLabel":16,"stem":64,"options":65,"answer":23,"analysis":29},1031038,"荧光灯的光通量，约与其端电压的（ ）次方成正比。",[66,68,69,71],{"key":20,"text":67,"correct":21},"1;",{"key":23,"text":45,"correct":28},{"key":25,"text":70,"correct":21},"3;",{"key":27,"text":72,"correct":21},"4",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":20,"analysis":29},1031041,"荧光灯管的使用寿命与其端电压关系是（ ）。",[77,79,81,83],{"key":20,"text":78,"correct":28},"端电压升高10%，使用寿命降低20%;端电压降低10%,使用寿命降低35%;",{"key":23,"text":80,"correct":21},"端电压升高10%，使用寿命增长20%;",{"key":25,"text":82,"correct":21},"端电压升高10%,使用寿命增长10%;",{"key":27,"text":84,"correct":21},"端电压升高5%，使用寿命延长10%。",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":23,"analysis":29},1031044,"高压钠灯的光通量，当电压降10%时，光通量降低（ ）。",[89,91,93,95],{"key":20,"text":90,"correct":21},"19%；",{"key":23,"text":92,"correct":28},"37%；",{"key":25,"text":94,"correct":21},"45%；",{"key":27,"text":96,"correct":21},"55%,",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":27,"analysis":29},1031047,"接在电动机控制设备电动机侧的电容器的额定电流，不应超过（ ). A.电动机额定电流； B电动机额定电流的0.9倍； C.电动机励磁电流； D.电动机励磁电流的0.9倍。",[101,102,103,104],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":28},{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":23,"analysis":29},1031050,"在中性点非直接接地的电网中，高压电容器组的接线方式宜为（）。",[109,111,113,115],{"key":20,"text":110,"correct":21},"三角形接线；",{"key":23,"text":112,"correct":28},"单或双星形接线，中性点不接地;",{"key":25,"text":114,"correct":21},"单或双星形接线，中性点经电阻接地；",{"key":27,"text":116,"correct":21},"三角形接线，B相相线接地。",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":23,"analysis":29},1031053,"在中性点非直接接地电网中，高压电容器组的接线方式，单星形和双星形比较， 宜优先采用（ ）。 A.双星形，中性点不接地； B单星形，中性点不接地； C.单星形，中性点直接接地； D.双星形，中性点直接接地。",[121,122,123,124],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":27,"analysis":29},1031056,"当电容器组的每相或每臂由多台电容器串联组合时，接线方式应是（ ）。",[129,131,133,135],{"key":20,"text":130,"correct":21},"先串联后并联；",{"key":23,"text":132,"correct":21},"不必计较先串联抑或先并联；",{"key":25,"text":134,"correct":21},"无论先串抑或先并都被允许；",{"key":27,"text":136,"correct":28},"先并联后串联。",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":20,"analysis":29},1031058,"在中性点非直接地的电网中， 当电容器组为星形接线时，电容器组的中性点应（).",[141,143,145,147],{"key":20,"text":142,"correct":28},"不接地；",{"key":23,"text":144,"correct":21},"直接接地；",{"key":25,"text":146,"correct":21},"经电阻接地；",{"key":27,"text":148,"correct":21},"经电抗接地。",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":27,"analysis":29},1031060,"当为电容器配置熔断器时，正确的原则是（）。 A.每5台电容器共用一支熔断器； B.每3台电容器共用一支熔断器； C.每2台电容器共用一支熔断器； D每1台电客器配置一支熔断器。",[153,154,155,156],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":28},{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":20,"analysis":29},1031063,"高压电容器组与放电装置之间（）。",[161,163,165,167],{"key":20,"text":162,"correct":28},"不应设置开关或熔断器，而应直接连接(不含保护单台电容器的熔断器）；",{"key":23,"text":164,"correct":21},"可以设置自动接通的触点；",{"key":25,"text":166,"correct":21},"可以设置断路器；",{"key":27,"text":168,"correct":21},"可以设置负荷开关，",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":23,"analysis":29},1031066,"低压电容器组与放电装置之间可设置（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":21},"隔离开关；",{"key":23,"text":176,"correct":28},"自动接通的触点；",{"key":25,"text":178,"correct":21},"熔断器；",{"key":27,"text":180,"correct":21},"带熔断器的隔离开关。",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":20,"analysis":29},1031069,"当电容器组的放电器为星形接线时，其中性点（ ）。 A.不应接地； B应直接接地； C.应经电感接地； D.应经电阻接地。",[185,186,187,188],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":25,"analysis":29},1031071,"避雷器用于限制并联电容器装置操作过电压时，应选用的型式是（) A.有间隙碳化硅避雷器； B有间隙碳化硅磁吹避雷器； C无间隙金属氧化物避雷器； D.有间隙金属氧化物避雷器",[193,194,195,196],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":20,"analysis":29},1031074,"并联电容器装置中的串联电抗器，当仅以限制涌流为目标，其电抗率宜取为（）。",[201,203,205,207],{"key":20,"text":202,"correct":28},"0.1%～1%；",{"key":23,"text":204,"correct":21},"4.5%～6%;",{"key":25,"text":206,"correct":21},"12%",{"key":27,"text":208,"correct":21},"30%.",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":23,"analysis":29},1031077,"并联电容器装置中的串联电抗器,当以抑制谐波为目标，且装置接人电网处的背 景谐波为5次及5次以上时，其电抗率宜取为（ ）。",[213,215,217,219],{"key":20,"text":214,"correct":21},"0.1%～1%",{"key":23,"text":216,"correct":28},"4.5%~6%；",{"key":25,"text":218,"correct":21},"12%;",{"key":27,"text":220,"correct":21},"30%。",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":20,"analysis":29},1031080,"10kV及以下配电所、变电所的高压及低压母线，当供电连续性要求不是很髙时， 宜采用（）接线。 A.单母线或分段单母线； B单母线带旁路母线； C.分段单母线带旁路母线； D.分段双母线带旁路母线。",[225,226,227,228],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":25,"analysis":29},1031082,"配电所、变电所的高压母线，当供电连续性要求很高吋，宜采用的接线是（ ）。 A.单母线或分段单母线； B单母线带旁路母线； C.分段单母线带旁路母线或双母线； D.双母线带旁路母线。",[233,234,235,236],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":20,"analysis":29},1031085,"配电所的10kV或6kV非专用电源线的进线侧，应装设（）。 A.带保护的开关设备； B不带保护的开关设备； C.隔离插头； D.隔离开关。",[241,242,243,244],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":20,"analysis":29},1031087,"10kV或6kV母线的分段处，可装设隔离开关或隔离触头的条件是( )。 A.出线回路数很少，分段开关无需带负荷操作且无继电保护和自动装置要求时； B出线回路数较多，需要分段开关带负荷橾作时； C.分段开关需备用自投入时； D.分段开关需设置过电流速断保护，以防止合闸到已存在故障的母线段上时。",[249,250,251,252],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":27,"analysis":29},1031089,"10、6kV分段单母线当需要进行带负荷切换或备用自动投人(BZT)时，母线分段 处宜装设（ ）。 A.隔离开关； B隔离插头； C.熔断器； D.断路器。",[257,258,259,260],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":28},{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":29},1031091,"10kV及以下两配电所之间的联络线，当两侧的供电可能性相同时，应装设的开关 的型式是（ ）。",[265,267,269,271],{"key":20,"text":266,"correct":28},"两侧都装设断路器；",{"key":23,"text":268,"correct":21},"两侧都装设隔离开关；",{"key":25,"text":270,"correct":21},"一侧装设断路器，另一侧装设隔离开关；",{"key":27,"text":272,"correct":21},"一侧装设带熔断器的负荷开关，另一侧装设隔离开关。",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":25,"analysis":29},1031093,"10kV及以下配电所引出线宜装设的开关型式宜是（ ）。",[277,278,280,282],{"key":20,"text":174,"correct":21},{"key":23,"text":279,"correct":21},"隔离插头；",{"key":25,"text":281,"correct":28},"断路器，当能满足继电保护和操作要求时，可采用带熔断器的负荷开关；",{"key":27,"text":283,"correct":21},"熔断器。",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":25,"analysis":29},1031094,"10kV及以下变、配电所向频繁操作的高压用电设备供电的出线开关兼做操作开关 时，应选用（ ) A.负荷开关； B负荷开关加熔断器； C.具有頻繁操作性能的断路器； D.不带熔断器的真空接触器",[288,289,290,291],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":20,"analysis":29},1031096,"当出线为架空线时，10(6)kV固定式配电装置出线断路器的线路侧（ ）。 A.应装设隔离开关； B可不装设隔离开关； C.严禁装设隔离开关； D.不应装设隔离开关。",[296,297,298,299],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":29},1031098,"当出线为有反馈可能的电缆线路时，10、6kV固定式配电装置出线断路器的线路 侧（ ）。 A.应装设隔离开关； B可不装设隔离开关； C.严禁装设隔离开关； D.不应装设隔离开关",[304,305,306,307],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":20,"analysis":29},1031100,"10kV或6kV固定式配电装置中，当采用焰断器负荷开关出线时，母线与熔断器负 荷开关之间（ ）",[312,314,316,318],{"key":20,"text":313,"correct":28},"应装设隔离开关；",{"key":23,"text":315,"correct":21},"不应装设隔离开关；",{"key":25,"text":317,"correct":21},"C可不装设隔离开关；",{"key":27,"text":319,"correct":21},"严禁装设隔离开关。",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":23,"analysis":29},1031102,"10kV及以下配电所，变电所架空进、出线上的避雷器回器中（) A.应装设隔离开关； B可不装设隔离开关； C.严禁装设隔离开关； D.不应装设隔离开关。",[324,325,326,327],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":23,"analysis":29},1031104,"10kV及以下配电所，接在母线上的避雷器和电压互感器（ ）。",[332,334,336,338],{"key":20,"text":333,"correct":21},"应分别单独装设隔离开关；",{"key":23,"text":335,"correct":28},"宜合用一组隔离开关；",{"key":25,"text":337,"correct":21},"可不装设隔离开关；",{"key":27,"text":319,"correct":21},{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":20,"analysis":29},1031106,"由地区电网供电的10kV及以下配电所电源进线处，宜装设供计费用的（ ）。",[343,345,347,349],{"key":20,"text":344,"correct":28},"专用的电压互感器和专用的电流互感器；",{"key":23,"text":346,"correct":21},"专用的电压互感器，电流互感器宜与其他仪表共用；",{"key":25,"text":348,"correct":21},"专用的电流互感器，电压互感器宜与其他仪表共用；",{"key":27,"text":350,"correct":21},"与其他仪表共用电流互感器，但不宜与继电保护装置共用电流互感器。",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":20,"analysis":29},1031108,"当10(6)\u002F0.4kV配电变压器就在本配电所内且为放射式专线供电，变压器一次侧 ( )。",[355,357,359,361],{"key":20,"text":356,"correct":28},"可不装设开关；",{"key":23,"text":358,"correct":21},"必須装设开关；",{"key":25,"text":360,"correct":21},"必須装设熔断器；",{"key":27,"text":362,"correct":21},"必须装设熔断器负荷开关.",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":25,"analysis":29},1031111,"当以树干式对10(6)\u002F0. 4kV变压器供电时，变压器一次侧（ ）。 A.可不装设开关；B应装设隔离开关； C.应装设带保护的开关设备或跌开式熔断器； D.不应装设开关。",[367,368,369,370],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":27,"analysis":29},1031113,"当出线回路较多、或有并列运行要求、或有继电保护和自动装置要求时，降压变 电所主变压器二次侧（10kV或6kV)的总开关，应采用（ ）。",[375,376,378,379],{"key":20,"text":174,"correct":21},{"key":23,"text":377,"correct":21},"隔离触头；",{"key":25,"text":178,"correct":21},{"key":27,"text":380,"correct":28},"断路器。",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":20,"analysis":29},1031115,"当出线回路较少且无并列运行要求，又无继电保护和自动装置要求时，降压变电 所主变压器二次侧（10kV或6kV)的总开关的选型原则是（ ）。",[385,387,389,391],{"key":20,"text":386,"correct":28},"可采用隔离开关或隔离触头；",{"key":23,"text":388,"correct":21},"必须选用断路器；",{"key":25,"text":390,"correct":21},"必须选用熔断器；",{"key":27,"text":392,"correct":21},"必须选用负荷开关。",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":20,"analysis":29},1031117,"当有继电保护要求、或需自动切换电源、或希望缩短手动切换电源的时间时，10 (6)\u002F0.4kV配电变压器二次总开关和母线分段开关，均应采用（ ）。 A.低压断路器； B隔离开关； C.隔离触头； D.熔断器。",[397,398,399,400],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":23,"analysis":29},1031118,"当0.4\u002F0.23kV母线具有双电源，且电源进线总开关和母线分段开关采用低压断路 器时，为便于检修低压断路器，宜采取的措施是（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":21},"低压断路器的一侧装设隔离开关或隔离触头；",{"key":23,"text":408,"correct":28},"B低压断路器的两侧装设隔离开关或隔离触头，或釆用移开式（插拔式、手车式）低 压断路器； -",{"key":25,"text":410,"correct":21},"禁止在低压断路器的两侧装设隔离开关；",{"key":27,"text":412,"correct":21},"无需装设任何隔离电器。",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":23,"analysis":29},1031120,"有两台及以上变压器的10kV及以下变电所，当其中任一台变压器断开时，其余变 压器的容量应能满足（ ）的用电。 A.仅一级负荷； B—级负荷和二级负荷； C. 一级、二级和三级负荷； D.仅一级负荷中特别重要的负荷。",[417,418,419,420],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":29},1031122,"多层或高层主体建筑内的lOkV及以下变电所，其变压器宜选用（ ）.",[425,427,429,431],{"key":20,"text":426,"correct":28},"不燃或难燃型变压器；",{"key":23,"text":428,"correct":21},"带护罩的油浸式变压器；",{"key":25,"text":430,"correct":21},"防腐型油浸式变压器；",{"key":27,"text":432,"correct":21},"防尘型油浸式变压器，",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":25,"analysis":29},1031124,"0kV及以下变电所所用油浸变压器，当装在髙压配电室中的高压柜内时，其油量 应小于（ ） A. 200kg； B 150kg； C. 100kg； D. 75kg。",[437,438,439,440],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":25,"analysis":29},1031126,"当10kV及以下变电所高压断路器的电磁操动机构采用硅整流合闸时，宜设两回路 所用电源，并注意其中一路应引自（）。",[445,447,449,451],{"key":20,"text":446,"correct":21},"母线电压互感器；",{"key":23,"text":448,"correct":21},"连接在另一段母线上的所用变压器；",{"key":25,"text":450,"correct":28},"C接在电源进线断路器前面的所用变压;",{"key":27,"text":452,"correct":21},"另一段母线电压互感器。",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":20,"analysis":29},1031128,"供一级负荷的配电所或大型配电所，当装有电磁操动机构的断路器时，直流操作 电源应采用（ ）。 A.220V或110V蓄电池作分、合闸电源； B-硅整流器合闸，电容器储能分闸； C.硅整流器合闸，48V蓄电池分闸； D.硅整流器合闸，小容量镉镍电池分闸。",[457,458,459,460],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":25,"analysis":29},1031130,"装有两台及以上主变压器的35~llOkV变电所，当其中一台变压器断开时，其余 变压器的容量，应能满足（ ）的用电。",[465,467,469,471],{"key":20,"text":466,"correct":21},"仅一级负荷中的一级负荷；",{"key":23,"text":468,"correct":21},"仅一级负荷；",{"key":25,"text":470,"correct":28},"一级与二级负荷，且不小于全部负荷的60%;",{"key":27,"text":472,"correct":21},"全部负荷。",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":27,"analysis":29},1031132,"具有三种电压的35~llOkV变电所，宜采用三绕组变压器的条件之一是各侧绕组 的负荷均达到该变压器额定容量的（）以上。",[477,479,481,483],{"key":20,"text":478,"correct":21},"5%；",{"key":23,"text":480,"correct":21},"7.5%；",{"key":25,"text":482,"correct":21},"10%；",{"key":27,"text":484,"correct":28},"15%。",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":27,"analysis":29},1031135,"35~llOkV变电所采用有载调压主变压器的条件，以下描述中正确的是（ ）",[489,491,493,495],{"key":20,"text":490,"correct":21},"单台变压器容量达5MVA及以上；",{"key":23,"text":492,"correct":21},"B有一级负荷中特别重要的负荷；",{"key":25,"text":494,"correct":21},"有一级负荷；",{"key":27,"text":496,"correct":28},"电力潮流变化大、电压偏差大，经计算，采用普通变压器不能满足电力系统和用户 对电能质量的要求时。",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":27,"analysis":29},1031138,"35~llOkV变电所采用内桥接线时，为了在检修进线断路时保证不中断线路供电， 常在进线断路器的外侧增设带两组隔离开关的跨条，请问在跨条上设置两组串联的隔离开关 的目的是（ ）。",[501,503,505,507],{"key":20,"text":502,"correct":21},"互为备用；",{"key":23,"text":504,"correct":21},"可选用较低额定电压的隔离开关；",{"key":25,"text":506,"correct":21},"可选用较低額定电流的隔离开关；",{"key":27,"text":508,"correct":28},"检修隔离开关时，不至于要求两回进线全部停电",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":27,"analysis":29},1031141,"35~llOkV变电所采用外桥接线，如桥上只装隔离开关（所谓隔离开关外桥），通 常都是由两组隔离开关串联构成，其目的是（ )",[513,515,516,518],{"key":20,"text":514,"correct":21},"两组隔离开关，互为备用；",{"key":23,"text":504,"correct":21},{"key":25,"text":517,"correct":21},"可选用较低额定电流的隔离开关；",{"key":27,"text":519,"correct":28},"检修隔离开关时，不至于要求两回进线和两台主变压器全部停电。",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":20,"analysis":29},1031143,"负荷缓慢地大幅度变化（昼夜性或季节性〉，主要影响电能质量指标中的（）。 A.电压偏差； B电压不平衡度； C.波形； D.频率，",[524,525,526,527],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},[529,532,535,538,541,544],{"id":15,"name":530,"category":7,"favorite":531},"领导干部任职前廉政法规知识测试题",92,{"id":533,"name":534,"category":7,"favorite":15},595,"建筑结构与设备",{"id":536,"name":537,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":539,"name":540,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":542,"name":543,"category":7,"favorite":8},534,"BIM工程师",{"id":545,"name":543,"category":7,"favorite":8},535]