[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-47":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":275},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,47,50,2321,[13,35,48,61,73,82,95,107,119,131,143,156,168,180,189,202,214,226,238,251,263],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1036606,2,"多选题","( )为电动机调速系统的静态指标。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","静差率；",true,{"key":24,"text":25,"correct":26},"B","超调量；",false,{"key":28,"text":29,"correct":26},"C","跟踪误差；",{"key":31,"text":32,"correct":22},"D","调速范围。","AD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1036610,"( )为电动机调速系统的动态指标。",[39,41,43,45],{"key":20,"text":40,"correct":26},"稳速精度；",{"key":24,"text":42,"correct":22},"动态波动量；",{"key":28,"text":44,"correct":22},"响应时间；",{"key":31,"text":46,"correct":26},"转速分辨率","BC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},1036613,"直流电动机调速系统的反馈回路中，一般应该加人滤波器。（ )是加入滤波器 的目的。",[52,54,56,58],{"key":20,"text":53,"correct":22},"滤掉反馈信号中的谐波成分I",{"key":24,"text":55,"correct":22},"抗干扰；",{"key":28,"text":57,"correct":26},"降低电枢发热；",{"key":31,"text":59,"correct":26},"提高系统功率因数。","AB",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":33,"analysis":34},1036617,"用晶闸管变流装置与直流电动机组成的直流调速系统中，（ ）不使用进线电 抗器。",[65,67,69,71],{"key":20,"text":66,"correct":22},"传动系统单机容量大于500kW,每台晶闸管变流器单独用一台整流变压器，将电网 电压变换成变流器所需的交流电压时",{"key":24,"text":68,"correct":26},"供电电源的容量是单台变流器容量的2倍，变流器所需的交流电压与电网电压相 同时；",{"key":28,"text":70,"correct":26},"传动系统单机容量小于500KW,多台变流器共用一台整流变压器时；",{"key":31,"text":72,"correct":22},"供电电源的容量是单台变流器容量的8倍，变流器所需的交流电压与电网电压相 同时。",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":81,"analysis":34},1036620,"( )是可编程序控制器基本组成部分。",[77,78,79,80],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},"ABCD",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":94,"analysis":34},1036624,"( )属于可编程序控制器的中央处理器（CPU)完成的任务。",[86,88,90,92],{"key":20,"text":87,"correct":22},"以扫描方式读入所有揄入装里的状态和数据；",{"key":24,"text":89,"correct":22},"完成软硬件系统的诊断；",{"key":28,"text":91,"correct":26},"供给PLC的内部电和总线电源；",{"key":31,"text":93,"correct":22},"执行逻辑运算.算术运算、数据传输等任务。","ABD",{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":97,"options":98,"answer":47,"analysis":34},1036627,"关于可编程序控制器的存储器的组成和功能，以下叙述错误的是（ ）。",[99,101,103,105],{"key":20,"text":100,"correct":26},"PLC的存储器是用来存放程序和数据的；",{"key":24,"text":102,"correct":22},"用户编制的应用程序存放在系统程序存储区；",{"key":28,"text":104,"correct":22},"存储器的用户程序存储区存放PLC的监控程序、管理程序、自诊断程序等；",{"key":31,"text":106,"correct":26},"存储器包括系统程序存储区、用户程序存储区和系统数据存储区。",{"id":108,"libraryId":5,"type":15,"typeLabel":16,"stem":109,"options":110,"answer":94,"analysis":34},1036630,"以下对一个PLC系统的扫描速度和扫描周期影响因素的叙述，不正确的是 ( ).",[111,113,115,117],{"key":20,"text":112,"correct":22},"不同系列、不同型号的PLC本身固有的扫描速度是相同的；",{"key":24,"text":114,"correct":22},"PLC系统的扫描周期包括输入采样、用户程序执行所用的时间，但不包括输出刷新 所用的时间；",{"key":28,"text":116,"correct":26},"PLC的扫描速庋与用户程序的长短密切相关，取决于控制系统的复杂程度和编程技 巧高低；",{"key":31,"text":118,"correct":22},"系统连接的I\u002FO点越少，系统扫描周期越长。",{"id":120,"libraryId":5,"type":15,"typeLabel":16,"stem":121,"options":122,"answer":94,"analysis":34},1036634,"在PLC的数据通信系统中，串行通信常用于（）的数据传送。",[123,125,127,129],{"key":20,"text":124,"correct":22},"计算机和PLC之间；",{"key":24,"text":126,"correct":22},"PLC和PLC之间；",{"key":28,"text":128,"correct":26},"PLC与UPS电源之间；",{"key":31,"text":130,"correct":22},"计算机与计算机之间。",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":33,"analysis":34},1036638,"PLC的基本数据通信方式有（ ）。",[135,137,139,141],{"key":20,"text":136,"correct":22},"并行通信；",{"key":24,"text":138,"correct":26},"无线通信；",{"key":28,"text":140,"correct":26},"点对点通信；",{"key":31,"text":142,"correct":22},"串行通信。",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":155,"analysis":34},1036641,"以下对并行数据通信方式的描述，正确的是（）。",[147,149,151,153],{"key":20,"text":148,"correct":22},"并行数据通信方式是指以字节或字为单位的数据传输方式；",{"key":24,"text":150,"correct":26},"并行数据传输方式是以二进制的位（bit)为单位的数据传输方式；",{"key":28,"text":152,"correct":22},"并行传送数据时，每个数据位都需要一条单独的数据线；",{"key":31,"text":154,"correct":26},"并行传输数据时，数据的各个不同位分时使用同一根传输线，从低位开始一位接一 位地依次传送。","AC",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":60,"analysis":34},1036644,"以下对串行数据通信方式的描述，正确的是（）。",[160,162,164,166],{"key":20,"text":161,"correct":22},"传输速度慢，需要的信号线少，适合远距离传输数据；",{"key":24,"text":163,"correct":22},"常用于计算机与PLC之间、多台PLC之间的数据通信；",{"key":28,"text":165,"correct":26},"常用于PLC内部各元件、主机与扩展模块之间的通信；",{"key":31,"text":167,"correct":26},"传输速度快，硬件成本高，不宜于远距离通信.",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":33,"analysis":34},1036648,"关于现场总线的基本概念，以下叙述正确的是（ ）。",[172,174,176,178],{"key":20,"text":173,"correct":22},"现场总线是一种开放的、数字式的、串行多点通信的数据控制网络；",{"key":24,"text":175,"correct":26},"由于现场总线要求信息传榆的实时性强、可靠性高，其网络结构必须由七层构成；",{"key":28,"text":177,"correct":26},"现场总线是专供DCS集散控制系统使用的，一般PLC系统较少使用",{"key":31,"text":179,"correct":22},"PROFIBUS是目前广泛应用的一种现场总线。",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":188,"analysis":34},1036652,"PLC与计算机控制系统的性能比较见表14-3,正确的是（〉.",[184,185,186,187],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},"BCD",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":201,"analysis":34},1036655,"在具备自动控制的生产线上，操作站系统是用来对工艺控制过程进行操作管理和监 视的一种人机接口装置。下列（ ）是操作站系统必需考虑的要求.",[193,195,197,199],{"key":20,"text":194,"correct":22},"应能对生产工艺过程显示和管理；",{"key":24,"text":196,"correct":22},"应能适应工厂生产现场的恶劣环境；",{"key":28,"text":198,"correct":22},"C对过程信号、画面刷新等实时快速响应；",{"key":31,"text":200,"correct":26},"操作站必须设在现场设备附近。","ABC",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":33,"analysis":34},1036658,"直流他励电动机要实现能耗制动，除了要把电动机电枢从直流电源断开外，还应采 取（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"在电枢回路中串电阻；",{"key":24,"text":209,"correct":26},"在励磁回路中串电阻；",{"key":28,"text":211,"correct":26},"切断励磁电源；",{"key":31,"text":213,"correct":22},"不切断励磁电源。",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":60,"analysis":34},1036662,"在工程设计中通常根据生产机械的负荷类型及工作制选用不同的电动机与之配套。 生产机械的负载转矩T随转矩n而变化的特性T = f(n)称为负载特性，图14-14中四组曲 线为不同生产机械的负载曲线。 图14-14中（ ）属于恒转矩负载？",[218,220,222,224],{"key":20,"text":219,"correct":22},"(a)；",{"key":24,"text":221,"correct":22},"(b)；",{"key":28,"text":223,"correct":26},"(c)；",{"key":31,"text":225,"correct":26},"(d)。",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":188,"analysis":34},1036665,"某工厂有一台同步电动机，电气参数为：额定功率1250kW,额定电压交流三相 6kV,额定电流0.144kA,额定启动电流倍数6倍，电动机启动转矩与额定转矩之比为 1.1, 6kV母线短路容量为40MVA,母线上预接负荷的无功功率为1Mvar,要求启动时母 线电压不低于额定电压的85%。选择启动方式和计算启动的有关参数。 下列（ ）启动方式可能作为本台电动机的启动方式。",[230,232,234,236],{"key":20,"text":231,"correct":26},"Y—△降压启动；",{"key":24,"text":233,"correct":22},"自耦变压器降压启动；",{"key":28,"text":235,"correct":22},"电抗器降压启动；",{"key":31,"text":237,"correct":22},"全压启动。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":250,"analysis":34},1036669,"—台风机配用额定功率为55kW的交流电动机，三角形接线，额定电压380V，额 定电流为102A。该电动机采用热继电器作过载和断相保护器件。为提高运行功率因数及减少启动时对电网的冲击，设计方案中考虑星-三角启动方式和电动机单独补偿电容器。请回 答以下热继电器设置及参数计算的有关问题。 为避免电动机启动时间太长而导致热继电器误动作，下列措施正确有效的是( )o",[242,244,246,248],{"key":20,"text":243,"correct":26},"提高热继电器的整定电流；",{"key":24,"text":245,"correct":22},"将热继电器经速饱和电流互感器接入主回路；",{"key":28,"text":247,"correct":26},"减小热继电器的整定电流；",{"key":31,"text":249,"correct":22},"在启动过程中短接热继电器过载保护器件。","BD",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":155,"analysis":34},1036673,"—台风机配用额定功率为55kW的交流电动机，三角形接线，额定电压380V，额 定电流为102A。该电动机采用热继电器作过载和断相保护器件。为提高运行功率因数及减少启动时对电网的冲击，设计方案中考虑星-三角启动方式和电动机单独补偿电容器。请回 答以下热继电器设置及参数计算的有关问题。 为提高系统运行功率因数，对风机的电动机单独设置补偿电容器。设置补偿电容器 后，以下热继电器的设置方案的调整，正确的是（ ）。",[255,257,259,261],{"key":20,"text":256,"correct":22},"如电容器接入位置在热继电器之前，整定电流值与原整定电流相同；",{"key":24,"text":258,"correct":26},"如电容器接入位置在热继电器之前，整定电流值为原整定电流1.5倍；",{"key":28,"text":260,"correct":22},"如电容器接入位置在热继电器之后，整定电流值为原整定电流0.92~0.95倍；",{"key":31,"text":262,"correct":26},"如电容器接入位置在热继电器之后，整定电流值与原整定电流相同；",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":20,"analysis":34},1036677,"某工厂有一台同步电动机，电气参数为：额定功率1250kW,额定电压交流三相 6kV,额定电流0.144kA,额定启动电流倍数6倍，电动机启动转矩与额定转矩之比为 1.1, 6kV母线短路容量为40MVA,母线上预接负荷的无功功率为1Mvar,要求启动时母 线电压不低于额定电压的85%。选择启动方式和计算启动的有关参数。 该同步电动机额定启动容量为（ ）（选最接近的一个数据）。",[267,269,271,273],{"key":20,"text":268,"correct":22},"9MVA；",{"key":24,"text":270,"correct":26},"7.5MVA；",{"key":28,"text":272,"correct":26},"5MVA;",{"key":31,"text":274,"correct":26},"2.5MV",[276,280,283,286,289,292],{"id":277,"name":278,"category":7,"favorite":279},1,"领导干部任职前廉政法规知识测试题",92,{"id":281,"name":282,"category":7,"favorite":277},595,"建筑结构与设备",{"id":284,"name":285,"category":7,"favorite":277},715,"招标采购专业知识与法律法规",{"id":287,"name":288,"category":7,"favorite":277},848,"市政方向-通用基础",{"id":290,"name":291,"category":7,"favorite":8},534,"BIM工程师",{"id":293,"name":291,"category":7,"favorite":8},535]