[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-45":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":618},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,45,50,2321,[13,34,48,57,70,82,94,107,119,132,145,156,169,182,194,206,218,230,242,254,266,274,282,294,306,318,330,343,355,367,379,391,403,415,427,439,451,463,475,487,499,511,523,535,547,559,570,582,594,606],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":32,"analysis":33},1036218,2,"多选题","消防控制室的控制设备应具备的控制及显示功能有C ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","控制消防设备的启、停，并应显示其工作状态,",true,{"key":24,"text":25,"correct":22},"B","显示系统供电电源的工作状态；",{"key":27,"text":28,"correct":22},"C","显示保护对象的重点部位、疏散通道及消防设备所在位置的平面图或模拟图等",{"key":30,"text":31,"correct":22},"D","显示火灾报警、故障报警的部位。","ABCD","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":47,"analysis":33},1036222,"火灾报警后，消防控制设备对防烟、排烟设施应具备的控制、显示功能有（",[38,40,42,45],{"key":20,"text":39,"correct":22},"停止有关部位的空调送风、关闭电动防火阀，并接收其反馈信号；",{"key":24,"text":41,"correct":22},"启动有关部位的防烟和排烟风机、排烟阀等，并接收其反債信号；",{"key":27,"text":43,"correct":44},"感烟探猁器报警后，控制作为防火分隔的防火卷帘下降至1.8m；",false,{"key":30,"text":46,"correct":22},"控制挡烟垂壁等防烟设施。","ABD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":56,"analysis":33},1036226,"下列应设置消防专用电话分机的部位有（ ）。 A.消防水泵房； 备用发电机房、配变电室s C.主要通风和空调机房、排烟机房； D.卫星电视机房。",[52,53,54,55],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":44},"ABC",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":69,"analysis":33},1036230,"某建筑总髙度为23m,每层建筑面积为2200m2的商场宜采用（ ）。",[61,63,65,67],{"key":20,"text":62,"correct":22},"区域报警系统；",{"key":24,"text":64,"correct":22},"集中报警系统；",{"key":27,"text":66,"correct":44},"控制中心报警系统；",{"key":30,"text":68,"correct":44},"不确定。","AB",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":56,"analysis":33},1036233,"下列场合中，（）时不宜选择离子感烟探测器。",[74,76,78,80],{"key":20,"text":75,"correct":22},"相对湿度经常大于95%；",{"key":24,"text":77,"correct":22},"有大量粉尘、水雾滞留；",{"key":27,"text":79,"correct":22},"在正常情况下有烟滞留；",{"key":30,"text":81,"correct":44},"经常有人员活动的场所。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":47,"analysis":33},1036237,"下列（ ）属于消防控制设备。",[86,88,90,92],{"key":20,"text":87,"correct":22},"电梯迫降控制装置；",{"key":24,"text":89,"correct":22},"防排烟控制装置；",{"key":27,"text":91,"correct":44},"排水泵控制装置；",{"key":30,"text":93,"correct":22},"喷淋増压泵控制装置。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":106,"analysis":33},1036241,"下列场所中，（ ）不宜选择光电感烟探测器。",[98,100,102,104],{"key":20,"text":99,"correct":44},"气流速度>5m的场所；",{"key":24,"text":101,"correct":22},"有大量粉尘、水雾滞留的场所；",{"key":27,"text":103,"correct":44},"正常情况下较黑暗的场所；",{"key":30,"text":105,"correct":22},"正常情下有烟滞留的场所。","BD",{"id":108,"libraryId":5,"type":15,"typeLabel":16,"stem":109,"options":110,"answer":32,"analysis":33},1036245,"缆式线型定温探测器适用于（ ）。",[111,113,115,117],{"key":20,"text":112,"correct":22},"电缆夹层；",{"key":24,"text":114,"correct":22},"计算机房吊顶内；",{"key":27,"text":116,"correct":22},"计算机房架空地板下；",{"key":30,"text":118,"correct":22},"皮带输送装置。",{"id":120,"libraryId":5,"type":15,"typeLabel":16,"stem":121,"options":122,"answer":131,"analysis":33},1036249,"火焰探测器不宜装设在（ ）场所。",[123,125,127,129],{"key":20,"text":124,"correct":44},"火灾时有强烈的火焰辐射；",{"key":24,"text":126,"correct":22},"在火焰出现前有浓烟扩散；",{"key":27,"text":128,"correct":22},"探测器易受阳光或其他光源照射；",{"key":30,"text":130,"correct":44},"液体燃烧等无阴燃阶段的大灾。","BC",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":144,"analysis":33},1036253,"房间高度为9m的丙类仓库不宜装设（ ）。",[136,138,140,142],{"key":20,"text":137,"correct":22},"感温探测器；",{"key":24,"text":139,"correct":44},"感烟探测器；",{"key":27,"text":141,"correct":44},"火焰探测器；",{"key":30,"text":143,"correct":22},"可燃气体探測器。","AD",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":69,"analysis":33},1036256,"房间高度为15m的展览厅不宜装设（ ）。",[149,151,153,154],{"key":20,"text":150,"correct":22},"感温探測器；",{"key":24,"text":152,"correct":22},"离子感烟探测器；",{"key":27,"text":141,"correct":44},{"key":30,"text":155,"correct":44},"红外光束感烟探测器.",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":168,"analysis":33},1036259,"对于建筑总高度为ILOM的酒店，下列（ ）可不设火灾探测器。",[160,162,164,166],{"key":20,"text":161,"correct":22},"卫生间；",{"key":24,"text":163,"correct":44},"封闭楼梯间；",{"key":27,"text":165,"correct":22},"游泳池；",{"key":30,"text":167,"correct":44},"水泵房。","AC",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":181,"analysis":33},1036263,"火灾自动报警系统主电源的保护开关不应采用（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":44},"断路器；",{"key":24,"text":176,"correct":44},"熔断器；",{"key":27,"text":178,"correct":22},"负荷开关；",{"key":30,"text":180,"correct":22},"漏电保护开关，","CD",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":69,"analysis":33},1036267,"建筑物内可能散发（）的场所应设可燃气体报警装置。",[186,188,190,192],{"key":20,"text":187,"correct":22},"可燃气体；",{"key":24,"text":189,"correct":22},"可燃蒸气；",{"key":27,"text":191,"correct":44},"可燃液体；",{"key":30,"text":193,"correct":44},"CO2。",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":32,"analysis":33},1036271,"智能化系统设计要素包括（）。",[198,200,202,204],{"key":20,"text":199,"correct":22},"信息设施系统；",{"key":24,"text":201,"correct":22},"信息应用系统；",{"key":27,"text":203,"correct":22},"建筑设备管理系统；",{"key":30,"text":205,"correct":22},"公共安全系统。",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":32,"analysis":33},1036275,"智能化集成系统应具有（）。",[210,212,214,216],{"key":20,"text":211,"correct":22},"可靠性；",{"key":24,"text":213,"correct":22},"容错性；",{"key":27,"text":215,"correct":22},"易维护性；",{"key":30,"text":217,"correct":22},"可扩展性。",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":69,"analysis":33},1036278,"下列（）场所的照明宜采用时间程序控制。",[222,224,226,228],{"key":20,"text":223,"correct":22},"公共卫生间；",{"key":24,"text":225,"correct":22},"公共走廊；",{"key":27,"text":227,"correct":44},"值班照明；",{"key":30,"text":229,"correct":44},"会议厅。",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":131,"analysis":33},1036282,"建筑设备管理系统的功能宜包括对电梯及自动扶梯的（）。",[234,236,238,240],{"key":20,"text":235,"correct":44},"启停控制；",{"key":24,"text":237,"correct":22},"运行状态显示；",{"key":27,"text":239,"correct":22},"故障报警；",{"key":30,"text":241,"correct":44},"遥控复位（迫降）。",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":47,"analysis":33},1036286,"建筑设备管理系统的功能宜包括送排风系统的（ ）。",[246,248,250,252],{"key":20,"text":247,"correct":22},"启、停控制；",{"key":24,"text":249,"correct":22},"风机故障报警；",{"key":27,"text":251,"correct":44},"风机电动机缺相保护；",{"key":30,"text":253,"correct":22},"运行状态显示。",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":265,"analysis":33},1036290,"建筑设备管理系统的功能宜包括空调制冷机组的（）。",[258,260,261,263],{"key":20,"text":259,"correct":44},"制冷机组保护；",{"key":24,"text":239,"correct":22},{"key":27,"text":262,"correct":22},"机组运行均衡控制；",{"key":30,"text":264,"correct":22},"机组台数控制。","BCD",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":181,"analysis":33},1036294,"建筑设备管理系统中常用的开关量控制阀有（）， A.电动二通阀；B.电动三通阀；C电动蝶阀； D.电磁阀。",[270,271,272,273],{"key":20,"text":20,"correct":44},{"key":24,"text":24,"correct":44},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":69,"analysis":33},1036298,"建筑设备管理系统中常用的电动调节阀有（）。 A.电动二通阀；B电动三通阀；C.电动蝶阀； D.电磁阀。",[278,279,280,281],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":44},{"key":30,"text":30,"correct":44},{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":144,"analysis":33},1036302,"扩声系统以下作法正确的有（ ）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"扩声系统保证听众有足够的声压级，声音清晰、声场均匀；",{"key":24,"text":289,"correct":44},"传声器信号线采用RVV系列导线；",{"key":27,"text":291,"correct":44},"声控室设不可开启的观察窗；",{"key":30,"text":293,"correct":22},"声控室与主扬声器距离较远时，在主扬声器系统安装位置的附近区域设置功放机房。",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":265,"analysis":33},1036306,"根据2006年版厅堂扩声系统设计规范，声学特性指标分为（）。",[298,300,302,304],{"key":20,"text":299,"correct":44},"音乐扩声类；",{"key":24,"text":301,"correct":22},"多用途类；",{"key":27,"text":303,"correct":22},"会议类；",{"key":30,"text":305,"correct":22},"文艺演出类。",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":47,"analysis":33},1036310,"病房呼叫系统一般由（ ）等组成。",[310,312,314,316],{"key":20,"text":311,"correct":22},"护士站主控台；",{"key":24,"text":313,"correct":22},"走廊显示屏；",{"key":27,"text":315,"correct":44},"病室门口对讲机；",{"key":30,"text":317,"correct":22},"病床呼叫单元,",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":32,"analysis":33},1036314,"常用显示屏的种类有（）。 A.发光二极管显示屏（LE",[322,324,326,328],{"key":20,"text":323,"correct":22},"； R阴极摄像管显示屏（CRT）；",{"key":24,"text":325,"correct":22},"等离子显示屏（PDP）；",{"key":27,"text":327,"correct":22},"液晶显示屏（LC",{"key":30,"text":329,"correct":22},"。",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":342,"analysis":33},1036318,"建筑智能化系统机房包括（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":22},"消防控制室；",{"key":24,"text":337,"correct":44},"物业管理用房；",{"key":27,"text":339,"correct":22},"弱电进线间；",{"key":30,"text":341,"correct":22},"扩声机房.","ACD",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":32,"analysis":33},1036320,"智能化系统机房设计中，应考虑（）。",[347,349,351,353],{"key":20,"text":348,"correct":22},"适当的机房位置、面积、层高、建筑装修要求；",{"key":24,"text":350,"correct":22},"适当的楼板荷载；",{"key":27,"text":352,"correct":22},"供电、接地、抗干扰要求；",{"key":30,"text":354,"correct":22},"空调、消防要求。",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":69,"analysis":33},1036324,"对于智能化系统机房，下列作法正确的有（ ）。",[359,361,363,365],{"key":20,"text":360,"correct":22},"不设于厕所、浴室或其他经常积水场所正下方，不与上述场所相贴邻；",{"key":24,"text":362,"correct":22},"做等电位联结；",{"key":27,"text":364,"correct":44},"设置于变电站旁边；",{"key":30,"text":366,"correct":44},"空调风管干线在机房内穿过。",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":342,"analysis":33},1036328,"对于楼层弱电间（弱电竖井），下列作法正确的有（ ）。",[371,373,375,377],{"key":20,"text":372,"correct":22},"采用丙级的防火门；",{"key":24,"text":374,"correct":44},"设有综合布线机柜时，房间使用面积4m2；",{"key":27,"text":376,"correct":22},"与强电竖井分别设置；",{"key":30,"text":378,"correct":22},"上下位置垂直对齐。",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":168,"analysis":33},1036354,"消防控制室布置，以下正确的有（ ）。",[383,385,387,389],{"key":20,"text":384,"correct":22},"设备面盘前橾作距离，单面布置时不小于1.5m,双面布置时不小于2.0m；",{"key":24,"text":386,"correct":44},"设备背后距墙不小于0.7m；",{"key":27,"text":388,"correct":22},"壁挂设备，侧面距墻不小于0.5m；",{"key":30,"text":390,"correct":44},"并排设备总长超过7m时，两侧均设置通道。",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":27,"analysis":33},1036358,"对火灾探测器设置的下列问题作出正确选择。 某车间的锯齿型屋顶坡度为30°,顶棚高度8~1Om,长80m,宽30m,若采用点型感烟探测器，则单个探测器的保护半径不应大于（）。",[395,397,399,401],{"key":20,"text":396,"correct":44},"4.9m；",{"key":24,"text":398,"correct":44},"7.2m；",{"key":27,"text":400,"correct":22},"8.0m；",{"key":30,"text":402,"correct":44},"9.9m。",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":56,"analysis":33},1036361,"电气传动系统一般由三部分组成，（ ）属于电气传动系统的主要组成部分。",[407,409,411,413],{"key":20,"text":408,"correct":22},"电动机；",{"key":24,"text":410,"correct":22},"电源装置；",{"key":27,"text":412,"correct":22},"控制装里；",{"key":30,"text":414,"correct":44},"照明系统。",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":69,"analysis":33},1036365,"以下电机属于直流电动机的有（ ）。",[419,421,423,425],{"key":20,"text":420,"correct":22},"他励电动机；",{"key":24,"text":422,"correct":22},"串励电动机；",{"key":27,"text":424,"correct":44},"励磁式同步电动机；",{"key":30,"text":426,"correct":44},"绕线型电动机。",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":56,"analysis":33},1036369,"下列电动机中，属于交流电动机的有（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":22},"无换向器电机；",{"key":24,"text":434,"correct":22},"鼠笼型电动机；",{"key":27,"text":436,"correct":22},"磁阻电动机；",{"key":30,"text":438,"correct":44},"复励电动机。",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":47,"analysis":33},1036373,"某电动机结构防护等级为IP54,以下对IP54的简述（ ）是不正确的。",[443,445,447,449],{"key":20,"text":444,"correct":22},"防止大于12mm固体进入电机、防滴电机；",{"key":24,"text":446,"correct":22},"防止大于1mm固体进入电机、防浸水电机；",{"key":27,"text":448,"correct":44},"防尘电机、防溅水电机；",{"key":30,"text":450,"correct":22},"防止大于1mm固体进入电机、防溅水电机。",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":56,"analysis":33},1036376,"根据生产机械的负载转矩随转速变化的负载特性，生产机械的负载类型有（ ）。]",[455,457,459,461],{"key":20,"text":456,"correct":22},"恒转矩负载；",{"key":24,"text":458,"correct":22},"恒功率负载；",{"key":27,"text":460,"correct":22},"风机、水泵类负载；",{"key":30,"text":462,"correct":44},"长期运行负载。",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":106,"analysis":33},1036379,"按照电动机转矩T的方向不同，电动机有四种运行状态，对应于T一n坐标平面上 的4个象限，电动机在（ ）工作时，能量从机械返回电动机。",[467,469,471,473],{"key":20,"text":468,"correct":44},"第1象限；",{"key":24,"text":470,"correct":22},"第2象限；",{"key":27,"text":472,"correct":44},"第3象限；",{"key":30,"text":474,"correct":22},"第4象限。",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":131,"analysis":33},1036383,"关于他励直流电动机磁通和转速的关系，以下说法正确的是（ ）。",[479,481,483,485],{"key":20,"text":480,"correct":44},"励磁电流越小，磁通量越大；",{"key":24,"text":482,"correct":22},"电枢端电压一定时，励磁电流越小转速越高；",{"key":27,"text":484,"correct":22},"励磁电流越大，磁通量越大；",{"key":30,"text":486,"correct":44},"电枢端电压一定时，励磁电流越大转速越髙。",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":181,"analysis":33},1036387,"下列关于复励直流电动机和并励直流电动机的特点的叙述，错误的是（ ）。",[491,493,495,497],{"key":20,"text":492,"correct":44},"复励直流电动机启动转矩比并励直流电动机大；",{"key":24,"text":494,"correct":44},"复励直流电动机过栽能力比并励直流电动机大；",{"key":27,"text":496,"correct":22},"复励直流电动机启动转矩比并励直流电动机小；",{"key":30,"text":498,"correct":22},"复励直流电动机过栽能力比并励直流电动机小。",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":342,"analysis":33},1036390,"当直流电动机吊放重物运行时，电枢电路外串附加电阻R逐渐加大，电动机速度降 低，电动机堵转时电枢电路外串附加电阻为R1，如继续加大则R>R1，下列对于此时电 动机的状态和操作的描述中，正确的是（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"转速变负，电动机将要反转；",{"key":24,"text":506,"correct":44},"这时应立即断开直流电机的电源，使电动机停车，避免发生事故；",{"key":27,"text":508,"correct":22},"这种状态为负载倒拉反转制动状态；",{"key":30,"text":510,"correct":22},"在R>R1的区域内，R值越大，重物下降的速度越高。",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":56,"analysis":33},1036394,"设定直流电动机外加电枢电压和励磁电流均为额定值，负载转矩为常数。当电枢电 路外串联电阻R数值增加时，下列叙述的状态正确的是（ ）。",[515,517,519,521],{"key":20,"text":516,"correct":22},"电动机机械特性的斜率增加；",{"key":24,"text":518,"correct":22},"电动机的转速降增加；",{"key":27,"text":520,"correct":22},"实际转速降低；",{"key":30,"text":522,"correct":44},"电动机的机械特性变硬。",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":47,"analysis":33},1036398,"当用直流电动机提升和下放重物运行时，外加电压和励磁电流均为额定值，用调节 电枢电路外串附加电阻R实现速度控制。下列对于直流电动机这种运行状态的描述中，正 确的是（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":22},"提升重物时，电枢回路附加电阻R增大，电动机转速降低；",{"key":24,"text":530,"correct":22},"提升重物时，当电枢回路附加电阻R增大到某一值时，电动机的转速为零，电动机 堵转；",{"key":27,"text":532,"correct":44},"下放重物时，直流电动机的电压方向应与提升重物时相反；",{"key":30,"text":534,"correct":22},"下放重物时，直流电动机的电源产生制动转矩.保证重物平稳下放。",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":265,"analysis":33},1036402,"A.甲区为恒转矩调速，乙区为恒功率调速； B.甲区调整电压，电压升高，转速提高；乙区调整",[539,541,543,545],{"key":20,"text":540,"correct":44},"励磁，磁通量増加，转速提高；",{"key":24,"text":542,"correct":22},"在甲区功率随着电压升高而加大；在乙区功率随",{"key":27,"text":544,"correct":22},"着转矩的降低而减小；",{"key":30,"text":546,"correct":22},"无论在甲区还是在乙区转矩和转速始终成正比。",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":56,"analysis":33},1036405,"采用以下（ ）设备可以用作直流电动机改变电压调速的方法。",[551,553,555,557],{"key":20,"text":552,"correct":22},"晶闸管变流器；",{"key":24,"text":554,"correct":22},"直流斩波器；",{"key":27,"text":556,"correct":22},"C旋转变流机组；",{"key":30,"text":558,"correct":44},"交-直-交变频器。",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":561,"answer":47,"analysis":33},1036410,[562,564,566,568],{"key":20,"text":563,"correct":22},"比例关系；",{"key":24,"text":565,"correct":22},"积分关系；",{"key":27,"text":567,"correct":44},"双曲线关系；",{"key":30,"text":569,"correct":22},"微分关系.",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":342,"analysis":33},1036413,"下列关于直流电动机改变磁通调速方法性能的描述，正确的是（ ）。",[574,576,578,580],{"key":20,"text":575,"correct":22},"改变磁通调速适合于恒功率调速；",{"key":24,"text":577,"correct":44},"当直流电动机在额定状态下运行时，励磁回路电流减小，电动机转速降低；",{"key":27,"text":579,"correct":22},"电动机励磁回路中改变其串联电阻的大小，可以改变励磁电流和磁通；",{"key":30,"text":581,"correct":22},"采用专门的励磁调节器来控制励磁电压，可以改变励磁电流和磁通。",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":47,"analysis":33},1036417,"双桥并联整流系统是在直流传动系统中使用的直流调速系统。以下（）不可以 作为双桥并联整流系统的整流变压器。",[586,588,590,592],{"key":20,"text":587,"correct":22},"1台接线组别为Dd的双绕组变压器；",{"key":24,"text":589,"correct":22},"2台接线组别为Yy的双绕组变压器；",{"key":27,"text":591,"correct":44},"1台三绕组变压器，二次绕组接线组别分别为Y和d;",{"key":30,"text":593,"correct":22},"1台三绕组变压器，二次绕组接线组别分剎为Y。和y。",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":265,"analysis":33},1036421,"以下（ ）不能作为双桥并联整流系统的整流器。",[598,600,602,604],{"key":20,"text":599,"correct":44},"2台三相桥式全波整流器；",{"key":24,"text":601,"correct":22},"3台单相桥式全波整流器：",{"key":27,"text":603,"correct":22},"1台三相挢式全波整流器；",{"key":30,"text":605,"correct":22},"2台单相桥式全波整流器.",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":265,"analysis":33},1036424,"双桥并联整流系统一般不适用于（）。",[610,612,614,616],{"key":20,"text":611,"correct":44},"1OOOkW以上直流电动机，晶闸管不需要串联；",{"key":24,"text":613,"correct":22},"1OOOkW以上直流电动机，晶闸管需要串联；",{"key":27,"text":615,"correct":22},"50~1OOkW直流电动机；",{"key":30,"text":617,"correct":22},"1OOkW以下永磁式同步电动机，",[619,623,626,629,632,635],{"id":620,"name":621,"category":7,"favorite":622},1,"领导干部任职前廉政法规知识测试题",92,{"id":624,"name":625,"category":7,"favorite":620},595,"建筑结构与设备",{"id":627,"name":628,"category":7,"favorite":620},715,"招标采购专业知识与法律法规",{"id":630,"name":631,"category":7,"favorite":620},848,"市政方向-通用基础",{"id":633,"name":634,"category":7,"favorite":8},534,"BIM工程师",{"id":636,"name":634,"category":7,"favorite":8},535]