[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-42":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":604},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,42,50,2321,[13,34,48,56,69,82,94,102,110,122,134,146,158,170,179,191,204,217,229,241,253,261,273,285,297,309,321,333,345,357,369,381,393,401,414,425,437,449,461,473,485,497,509,521,533,544,556,568,580,592],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":32,"analysis":33},1035732,2,"多选题","按用途，A类电气装置的接地有（）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","工作（系统）接地；",true,{"key":24,"text":25,"correct":22},"B","保护接地；",{"key":27,"text":28,"correct":22},"C","雷电保护接地；",{"key":30,"text":31,"correct":22},"D","防静电接地","ABCD","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":47,"analysis":33},1035735,"发电厂、变电所接地的一般要求，正确的是（ ）。",[38,41,43,45],{"key":20,"text":39,"correct":40},"变电所内不同用途和不同电压的电气装置、设施，应分别设置接地装里；",false,{"key":24,"text":42,"correct":22},"变电所内不同用途和不同电压的电气装置、设施，应使用一个总的接地装置;",{"key":27,"text":44,"correct":22},"总接地装置的接地电阻应符合不同用途中最小值的要求；",{"key":30,"text":46,"correct":40},"各接地装置的接地电阻应分别符合不同用途的要求。","BC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":50,"answer":55,"analysis":33},1035736,[51,52,53,54],{"key":20,"text":20,"correct":40},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},"BCD",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":68,"analysis":33},1035739,"A类电气装置保护接地的范围包括（）.",[60,62,64,66],{"key":20,"text":61,"correct":22},"互感器的二次绕组；",{"key":24,"text":63,"correct":22},"铠装控制电缆的外皮；",{"key":27,"text":65,"correct":40},"安装在配电屏上的低压电器外壳；",{"key":30,"text":67,"correct":22},"装在配电线路杆塔上的开关设备、电容器等电气设备。","ABD",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":81,"analysis":33},1035741,"A类电气装置保护接地的范围包括（）。",[73,75,77,79],{"key":20,"text":74,"correct":22},"装有避雷线的架空线路杆塔；",{"key":24,"text":76,"correct":40},"沥青地面居民区内，不接地、经消弧线圈和高电阻接地系统中，无避雷线架空线路 的金属和钢筋混凝土杆塔；",{"key":27,"text":78,"correct":22},"一般居民区内，不接地、经消弧线圈和高电阻接地系统中，无避雷线架空线路的金 属和钢筋混凝土杆塔；",{"key":30,"text":80,"correct":22},"电力电缆接线盒、终端盒的外壳。","ACD",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":68,"analysis":33},1035746,"发电厂、变电所的电气设备和电力生产设施的下列金属部分，可不接地的 是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"不良导电地面的干燥房间内，交流标称电压380V及以下的电气设备外壳，且维护 人员不可能同时触及其他接地物体者；",{"key":24,"text":89,"correct":22},"标称电压220V及以下的蓄电池室内的支架；",{"key":27,"text":91,"correct":40},"一般居民区内，不接地、经消弧线圏和高电阻接地系统中，无避雷线架空线路的金属和钢筋混凝土杆塔；",{"key":30,"text":93,"correct":22},"由发电厂、变电所区域内引出的无防静电接地要求的铁路轨道。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":55,"analysis":33},1035749,"发电厂、变电所A类电气装置保护接地的接地电阻应符合（ ）要求。 A.不接地、经消弧线圈和高电阻接地系统中，髙压与发电厂、变电所电力生产用低压",[98,99,100,101],{"key":20,"text":20,"correct":40},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":81,"analysis":33},1035751,"A类电气装置的接地电阻应符合（）要求。",[106,107,108,109],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":40},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":55,"analysis":33},1035754,"A类电气装置保护接地的计箅用接地故障电流I应为（ ）。",[114,116,118,120],{"key":20,"text":115,"correct":40},"对有效接地系统和低电阻接地系统，采用系统最大运行方式下的接地短路电流或单 相接地故障电流；",{"key":24,"text":117,"correct":22},"B对有效接地系统和低电阻接地系统，采用在接地装置内、外短路时，经接地装置流 入地中最大短路电流对称分量的最大值；",{"key":27,"text":119,"correct":22},"对装有消弧线圏的发电厂、变电所电气装置的接地装置，等于接在其上的同一系统 各消弧线囷颏定电流总和的1. 25倍；",{"key":30,"text":121,"correct":22},"对不装消弧线圈的发电厂、变电所电气装置的接地装置，等于系统中断开最大一台 消弧线围或最长线路被切除时的最大可能残余电流值。",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":68,"analysis":33},1035756,"高土壤电阻率地区，可采用的降低接地电阻的措施有（ ）。",[126,128,130,132],{"key":20,"text":127,"correct":22},"敷设引外接地极，但距离不超过2000m;",{"key":24,"text":129,"correct":22},"采用井式或深钻式接地极；",{"key":27,"text":131,"correct":40},"在永冻土层内敷设接地网；",{"key":30,"text":133,"correct":22},"填充电阻率较低的物质或降阻剂。",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":55,"analysis":33},1035758,"关于发电厂、变电所接地装置的设置，正确的是（）。",[138,140,142,144],{"key":20,"text":139,"correct":40},"接地装置应利用自然接地极，当其接地电阻符合要求时，可不另设人工接地极；",{"key":24,"text":141,"correct":22},"接地装置除利用自然接地极外，还应敷设以水平接地极为主的人工接地网；",{"key":27,"text":143,"correct":22},"接地装置应与架空线路的避雷线相连，且有便于分开的连接点；",{"key":30,"text":145,"correct":22},"对于3~IOkV变电所、配电所，当采用建筑物的基础作接地极且接地电阻又满足 規定值时，可不另设人工接地。",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":32,"analysis":33},1035761,"关于发电厂、变电所以水平接地极为主的人工接地网的敷设，正确的是（ ）。",[150,152,154,156],{"key":20,"text":151,"correct":22},"接地网外缘应闭合，各角应为圆弧形，圓弧半径不宜小于均压带间距的一半；",{"key":24,"text":153,"correct":22},"接地网内应敷设水平均压带，均压带可采用等间距或不等间距布置；",{"key":27,"text":155,"correct":22},"接地两网的埋设深度不宜小于0.6m;",{"key":30,"text":157,"correct":22},"35 kV及以上变电所接地网边缘经常有人出入的走道处，应铺设砾石、沥青路面或 在地下装设两条均压带。",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":32,"analysis":33},1035764,"发电厂、变电所接地装置的导体应符合（）要求。",[162,164,166,168],{"key":20,"text":163,"correct":22},"热稳定；",{"key":24,"text":165,"correct":22},"均压；",{"key":27,"text":167,"correct":22},"防腐蚀；",{"key":30,"text":169,"correct":22},"机械强度。",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":178,"analysis":33},1035765,"A类电气装置的接地装置，其地下导体按机械强度要求的最小尺寸为（ ）。 A.圆钢的直径6mm; B扁钢的截面48mm2; C.扁钢的截面24mm2; D.角钢和扁钢的厚度4mm。",[174,175,176,177],{"key":20,"text":20,"correct":40},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":40},{"key":30,"text":30,"correct":22},"BD",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":81,"analysis":33},1035767,"A类电气装置的接地装置，其地上屋内导体按机械强度要求的最小尺寸为（ )。",[183,185,187,189],{"key":20,"text":184,"correct":22},"A圆钢的直径6mm;",{"key":24,"text":186,"correct":40},"扁钢的截面48mm2;",{"key":27,"text":188,"correct":22},"C扁钢的截面24mm2;",{"key":30,"text":190,"correct":22},"扁钢的厚度3mm。",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":203,"analysis":33},1035770,"发电厂、变电所电气装置中，应专门敷设接地线的部位是（ ）。",[195,197,199,201],{"key":20,"text":196,"correct":22},"避雷器、避雷线、避雷针等的接地端子；",{"key":24,"text":198,"correct":22},"变压器中性点接地设备的接地端子和直接接地的变压器中性点；",{"key":27,"text":200,"correct":22},"11OkV及以上钢筋混凝土构件支座上电气设备的金属外壳；",{"key":30,"text":202,"correct":40},"1lOkV及以上钢结构支座上电气设备的金属外壳。","ABC",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":216,"analysis":33},1035773,"当不要求采用专门敷设接地线时，发电厂、变电所电气设备的接地线宜利 用（ ）。",[208,210,212,214],{"key":20,"text":209,"correct":22},"金属构件和普通钢筋混凝土构件的钢筋；",{"key":24,"text":211,"correct":40},"B穿线的金属蛇皮管；",{"key":27,"text":213,"correct":22},"穿线的钢管和电缆的铅、铝外皮；",{"key":30,"text":215,"correct":40},"低压照明导线的铅皮。","AC",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":55,"analysis":33},1035776,"发电厂、变电所电气设备接地线的截面应进行热稳定校验，接地线的温度应符合 的要求是（ ）。 A.在有效接地系统和低电阻接地系统中，接地线的短时温度：钢线不超过500℃、铜 线不超过400℃、铝线不超过300℃;",[221,223,225,227],{"key":20,"text":222,"correct":40},"在有效接地系统和低电阻接地系统中，接地线的短时温度：钢线不超过400℃、铜 线不超过450℃、铝线不超过300℃;",{"key":24,"text":224,"correct":22},"在不接地、经消弧线围和髙电阻接地系统中，接地线的长时间温度：地上敷设者不 大于150℃、地下敷设者不大于100℃;",{"key":27,"text":226,"correct":22},"与架空送配电线路相连的6~66 kV电气设备接地线，应按两相异地短路校验热稳",{"key":30,"text":228,"correct":22},"定，接地线的短时温度：钢线不超过400℃、铜线不超过450℃、铝线不超过300℃。",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":68,"analysis":33},1035778,"关于发电厂、变电所电气设备埃地线的连接，正确的是（）。",[233,235,237,239],{"key":20,"text":234,"correct":22},"接地线各线段的连接应采用焊接；当为搭接焊接时，搭接长度应为扁钢宽度的2倍 或圆钢直径的6倍；",{"key":24,"text":236,"correct":22},"B接地线与接地极的连接宜采用焊接；",{"key":27,"text":238,"correct":40},"接地线与GlS接地母线的连接宜采用焊接",{"key":30,"text":240,"correct":22},"当利用钢管作接地线时，钢管连接处应保证有可靠的电气连接。",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":81,"analysis":33},1035779,"关于接地线与电气设备的连接，正确的是（）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"接地线与电气设备的连接可用螺栓连接或焊接；",{"key":24,"text":248,"correct":40},"接地线与电气设备的连接禁止采用焊接；",{"key":27,"text":250,"correct":22},"用螺栓连接时应设防松螺帽或防松垫片；",{"key":30,"text":252,"correct":22},"电气设备每个接地部分应以单独的接地线与接地母线相连接，严禁在一个接地线中 串接几个需要接地的部分。",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":178,"analysis":33},1035783,"按IEC标准，低压电气装置（建筑物电气装置）的两种接地为（ ）。 A.工作接地； B功能性接地； C.雷电保护接地； D.防护性接地。",[257,258,259,260],{"key":20,"text":20,"correct":40},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":40},{"key":30,"text":30,"correct":22},{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":55,"analysis":33},1035785,"低压配电系统的带电导体系统分类包括（ ）。",[265,267,269,271],{"key":20,"text":266,"correct":40},"TN系统；",{"key":24,"text":268,"correct":22},"三相四线系统；",{"key":27,"text":270,"correct":22},"三相三线系统；",{"key":30,"text":272,"correct":22},"单相三线系统",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":203,"analysis":33},1035788,"低压配电系统的接地系统分类包括（ ）。",[277,279,281,283],{"key":20,"text":278,"correct":22},"TN系统;",{"key":24,"text":280,"correct":22},"TT系统；",{"key":27,"text":282,"correct":22},"IT系统；",{"key":30,"text":284,"correct":40},"三相五线系统.",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":55,"analysis":33},1035790,"TN-S系统适用于设有变电所的工业与民用建筑中（ ）。",[289,291,293,295],{"key":20,"text":290,"correct":40},"对供电连续性要求高、对接触电压有严格限制者；",{"key":24,"text":292,"correct":22},"单相负荷较大或非线性负荷较多者；",{"key":27,"text":294,"correct":22},"有较多信息技术系统者;",{"key":30,"text":296,"correct":22},"有爆炸、火灾危险者。",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":47,"analysis":33},1035793,"关于TN-C系统、TN-C-S系统的适用范围，正确的是（ ）。",[301,303,305,307],{"key":20,"text":302,"correct":40},"TN-C系统适用于对可靠性要求不高的民用建筑;",{"key":24,"text":304,"correct":22},"TN-C系统适用于有专业人员维护管理的一般工业厂房；",{"key":27,"text":306,"correct":22},"TN-C-S系统适用于无变电所而适用TN-S系统的工业与民用建筑；",{"key":30,"text":308,"correct":40},"TN-C-S系统适用于无等电位联结的户外场所。",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":68,"analysis":33},1035795,"关于TT系统和IT系统的适用范围，正确的是（ ）。",[313,315,317,319],{"key":20,"text":314,"correct":22},"TT系统适用于无变电所而适用TN-S系统的民用建筑；",{"key":24,"text":316,"correct":22},"TT系统适用于无等电位联结的户外场所；",{"key":27,"text":318,"correct":40},"TT系统适用于应急电源系统和矿井下电气装置；",{"key":30,"text":320,"correct":22},"IT系统适用于应急电源系统和矿井下电气装置。",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":216,"analysis":33},1035797,"关于不同接地系统的兼容性，正确的是（）。",[325,327,329,331],{"key":20,"text":326,"correct":22},"同一建筑物内宜采用TN系统或TT系统中的一种；",{"key":24,"text":328,"correct":40},"同一建筑物内IT系统不能和TN系统或TT系统兼容；",{"key":27,"text":330,"correct":22},"同一变压器供电范围内IT系统不能和TN系统或TT系统兼容；",{"key":30,"text":332,"correct":40},"同一变压器供电范围内TN系统和TT系统不能兼容。",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":178,"analysis":33},1035800,"外露可导电部分、外部可导电部分的正确定义是（ ）。 A.外露可导电部分是电气设备的带电部分，正常情况下不能触及，但因外壳防护缺陷 或损坏而能触及者；",[337,339,341,343],{"key":20,"text":338,"correct":40},"外露可导电部分是电气设备上能触及的在正常情况下不带电，但在基本绝缘棋损坏时",{"key":24,"text":340,"correct":22},"可变为带电的可导电部分；",{"key":27,"text":342,"correct":40},"外部可导电部分是室外电气装置或其他设施上能触及的可导电部分；",{"key":30,"text":344,"correct":22},"外部可导电部分是不是电气装置的组成部分且易于引入一个电位（通常是局部电位) 的可导电部分。",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":216,"analysis":33},1035802,"保护导体、保护联结导体的正确定义是（）。",[349,351,353,355],{"key":20,"text":350,"correct":22},"保护导体是为安全目的（如电击防护）而设置的导体；",{"key":24,"text":352,"correct":40},"保护导体是为防护性或功能性接地而设置的导体；",{"key":27,"text":354,"correct":22},"保护联结导体是为保护性等电位联结而设置的导体；",{"key":30,"text":356,"correct":40},"保护联结导体是保护导体和等电位联结导体的统称。",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":55,"analysis":33},1035805,"间接接触防护接地的一般要求包括（）。",[361,363,365,367],{"key":20,"text":362,"correct":40},"无论何种间接接触防护、外露可导电部分均应与保护导体相连接。",{"key":24,"text":364,"correct":22},"间接接触防护采用自动切断电源时，外露可导电部分应与保护导体相连接；",{"key":27,"text":366,"correct":22},"保护导体应按其系统接地型式的具体条件与外露可导电部分连接和接地；",{"key":30,"text":368,"correct":22},"可同时触及的外露可导电部分，应接到同一个接地系统上。",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":203,"analysis":33},1035810,"在各种间接接触防护中，不应接地的例子是（ ）。",[373,375,377,379],{"key":20,"text":374,"correct":22},"采用Ⅱ类设备时；",{"key":24,"text":376,"correct":22},"采用非导电场所时；",{"key":27,"text":378,"correct":22},"采用电气分隔时；",{"key":30,"text":380,"correct":40},"采用自动切断电源时。",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":68,"analysis":33},1035817,"可以省去间接接触防护接地的例子是（）。",[385,387,389,391],{"key":20,"text":386,"correct":22},"触及不到钢筋的钢筋混凝土电杆；",{"key":24,"text":388,"correct":22},"伸臂范围以外的架空线绝缘子的支撑物；",{"key":27,"text":390,"correct":40},"装有額定动作电流为30mA的剩余电流保护装置时；",{"key":30,"text":392,"correct":22},"因尺寸小或因其位置不会被抓住或不会与人身有效接触，且与保护导体连接很困难 或连接不可靠时。",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":178,"analysis":33},1035820,"TN系统中发生相线对外露可导电部分的接地故障时，降低系统接地电阻对故障电 流和接触电压的影响是（ ）。 A.故障电流升高； B故障电流基本不变;C.接触电压降低； D.接触电压基本不变。",[397,398,399,400],{"key":20,"text":20,"correct":40},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":40},{"key":30,"text":30,"correct":22},{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":413,"analysis":33},1035823,"采用TN-C-S系统时，降低预期接触电压的正确措施是（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":22},"降低保护导体电阻；",{"key":24,"text":408,"correct":40},"降低系统接地电阻；",{"key":27,"text":410,"correct":40},"进线处重复接地；",{"key":30,"text":412,"correct":22},"实施总等电位联结。","AD",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":216,"analysis":33},1035825,"手持式用电设备和固定式设备由同一配电箱供电时，降低预期接触电压的正确措施",[418,420,422,424],{"key":20,"text":419,"correct":22},"是( )。",{"key":24,"text":421,"correct":40},"降低保护导体电阻； B降低系统接地电阻；",{"key":27,"text":423,"correct":22},"做局部等电位联结；",{"key":30,"text":412,"correct":40},{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":55,"analysis":33},1035828,"由TN系统供电的总等电位联结作用区以外（如室外）的电气设备，其间接接触防 护可采用（ ）。",[429,431,433,435],{"key":20,"text":430,"correct":40},"局部IT系统；",{"key":24,"text":432,"correct":22},"局部TT系统；",{"key":27,"text":434,"correct":22},"Ⅱ类设备；",{"key":30,"text":436,"correct":22},"经隔离变压器供电。",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":413,"analysis":33},1035831,"按建筑物电气装置的接地配置要求，埋入土壤中接地极的最小尺寸为（ ）。",[441,443,445,447],{"key":20,"text":442,"correct":22},"每股直径1.8mm的铜绞线，截面不小于25mm2;",{"key":24,"text":444,"correct":40},"每股直径1.0mm的铜绞线，截面不小于50mm2;",{"key":27,"text":446,"correct":40},"热浸锌的型钢，厚度不小于2mm，截面不小于50mm2;",{"key":30,"text":448,"correct":22},"热浸锌的型钢，厚度不小于3mm，截面不小于90mm2。",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":68,"analysis":33},1035833,"按建筑物电气装置的接地配置要求，有腐蚀防护的接地导体的最小截面为（ ）。",[453,455,457,459],{"key":20,"text":454,"correct":22},"无机械损伤防护的铜、铁导体，不小于16mm2;",{"key":24,"text":456,"correct":22},"有机械损伤防护的铜导体，不小于2. 5mm2;",{"key":27,"text":458,"correct":40},"有机械损伤防护的铜导体，不小于4mm2;",{"key":30,"text":460,"correct":22},"有机械损伤防护的铁导体，不小于IOmm2",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":47,"analysis":33},1035836,"按建筑物电气装置的接地配置要求，无腐蚀防护的接地导体的最小截面为（）。",[465,467,469,471],{"key":20,"text":466,"correct":40},"铜导体不小于16mm2;",{"key":24,"text":468,"correct":22},"铜导体不小于25mm2;",{"key":27,"text":470,"correct":22},"铁导体不小于50mm2 ；",{"key":30,"text":472,"correct":40},"铁导体不小于90mm2。",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":32,"analysis":33},1035839,"可用作保护导体的是（）。",[477,479,481,483],{"key":20,"text":478,"correct":22},"多芯电缆中的导体；",{"key":24,"text":480,"correct":22},"与带电导体共用的外护物；",{"key":27,"text":482,"correct":22},"固定安装的棵露或绝缘的导体；",{"key":30,"text":484,"correct":22},"符合条件的电缆金属护套、铠装、屏蔽层等。",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":203,"analysis":33},1035842,"不允许用作保护导体或保护联结导体的是（).",[489,491,493,495],{"key":20,"text":490,"correct":22},"金属水管、燃气或可燃液体金属管；",{"key":24,"text":492,"correct":22},"正常使用中承受机械应力的结构部分、支撑线；",{"key":27,"text":494,"correct":22},"柔性或可挠金属导管、柔性金属部件；",{"key":30,"text":496,"correct":40},"电缆托盘和梯架。",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":55,"analysis":33},1035844,"对保护导体的电气连续性的要求是（）。",[501,503,505,507],{"key":20,"text":502,"correct":40},"保护导体的连接应为焊接；",{"key":24,"text":504,"correct":22},"在保护导体中不应串入开关器件；",{"key":27,"text":506,"correct":22},"器具的外露可导电部分不应用于构成其他设备保护导体的一部分",{"key":30,"text":508,"correct":22},"保护导体对机械、化学或电化学损伤应有适当的防护性能。",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":413,"analysis":33},1035847,"对加强型保护导体的界定和要求，正确的是（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":22},"加强型保护导体是电流超过1OmA的保护导体；",{"key":24,"text":516,"correct":40},"加强型保护导体是电流超过1OA的保护导体；",{"key":27,"text":518,"correct":40},"加强型保护导体的全长应采用截面至少为4mm2的铜导体或16mm2的铝导体；",{"key":30,"text":520,"correct":22},"加强型保护导体的全长应采用截面至少为1Omm2的铜导体或16mm2的铝等体。",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":81,"analysis":33},1035849,"TN系统中低压电气装置对高压系统接地故障的防护，正确的是（ ）。",[525,527,529,531],{"key":20,"text":526,"correct":22},"TN系统中故障电压应在给定的时间内被切断；",{"key":24,"text":528,"correct":40},"TN系统中应力电压应在给定的时间内被切断；",{"key":27,"text":530,"correct":22},"如在给定的时间内切断的条件得不到满足，低压系统中性导体应通过一个电气上独 立的接地极接地；",{"key":30,"text":532,"correct":22},"建筑物已实施总等电位联结时，预期接触电压实际为零。",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":47,"analysis":33},1035852,"TT系统中低压电气装置对高压系统接地故障的防护，正确的是（ ）。",[537,539,541,542],{"key":20,"text":538,"correct":40},"TT系统中故障电压应在给定的时间内被切断；",{"key":24,"text":540,"correct":22},"TT系统中应力电压应在给定的时间内被切断；",{"key":27,"text":530,"correct":22},{"key":30,"text":543,"correct":40},"建筑物已实施总等电位联结时，加在絶缘上的应力电压不会升高。",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":216,"analysis":33},1035855,"如果下列（ ）和（ ）能分别或同时满足，则可认为符合低压电气装置对髙 压系统接地故障的防护的条件。",[548,550,552,554],{"key":20,"text":549,"correct":22},"变电所连接的有金属护层的高、低压电缆总长度超过1km;",{"key":24,"text":551,"correct":40},"变电所连接的有金属护层的高、低压电缆总长度超过",{"key":27,"text":553,"correct":22},"变电所外露可导电部分的接地电阻（保护接地电阻）不超过1n;",{"key":30,"text":555,"correct":40},"变电所外露可导电部分的接地电阻（保护接地电阻）不超过2n.",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":68,"analysis":33},1035858,"信息技术装置接地和等电位联结的一般要求包括（）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"建筑物的总接地端子通常能用于功能性接地；",{"key":24,"text":563,"correct":22},"B信息技术装置的功能性接地可利用其供电回路的保护导体；",{"key":27,"text":565,"correct":40},"信息技术装置的功能性接地不得利用其供电回路的保护导体；",{"key":30,"text":567,"correct":22},"建筑物的总接地端子可通过连接一根接地干线加以延伸，以使信息技术装置以尽可 能短的距离与其联结和\u002F或接地.",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":216,"analysis":33},1035861,"信息技术装置接地和等电位联结的一般要求包括（）。 A.接地干线宜采用50mm2的铜导体，在建筑物边界线内側四周敷设成一个等电位联",[572,574,576,578],{"key":20,"text":573,"correct":22},"结环；",{"key":24,"text":575,"correct":40},"接地干线宜采用0.5XIOOmm的薄铜带，装设在总接地端子箱内；",{"key":27,"text":577,"correct":22},"功能性等电位联结可由导体、电缆护皮、建筑物中的金属构件如水管、电缆管道、 安装在各楼层或某区域的金属网状结构物等组成；",{"key":30,"text":579,"correct":40},"功能性等电位联结应采用专门敷设的导体，以星形结构连接到建筑物的总接地端子箱",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":32,"analysis":33},1035862,"室内场所照明开关和控制要求有（ ）。",[584,586,588,590],{"key":20,"text":585,"correct":22},"每个开关所控光源数不宜太多；",{"key":24,"text":587,"correct":22},"所控灯列与侧窗平行；",{"key":27,"text":589,"correct":22},"生产场所宜按车间、工段或工序分组；",{"key":30,"text":591,"correct":22},"报告厅、电化教室等场所，靠近讲台部分灯具应能单独控制。",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":68,"analysis":33},1035865,"道路照明的控制要求有（）。",[596,598,600,602],{"key":20,"text":597,"correct":22},"宜采用集中控制； ‘",{"key":24,"text":599,"correct":22},"宜采用按道路亮度和设定时间自动控制；",{"key":27,"text":601,"correct":40},"每个开关所控灯数不要太多，开关应设置在靠近灯、操作方便、安全的位置； ：",{"key":30,"text":603,"correct":22},"应采用半夜降低照度的节能控制方式。",[605,609,612,615,618,621],{"id":606,"name":607,"category":7,"favorite":608},1,"领导干部任职前廉政法规知识测试题",92,{"id":610,"name":611,"category":7,"favorite":606},595,"建筑结构与设备",{"id":613,"name":614,"category":7,"favorite":606},715,"招标采购专业知识与法律法规",{"id":616,"name":617,"category":7,"favorite":606},848,"市政方向-通用基础",{"id":619,"name":620,"category":7,"favorite":8},534,"BIM工程师",{"id":622,"name":620,"category":7,"favorite":8},535]