[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-41":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":579},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,41,50,2321,[13,34,42,54,66,78,89,101,111,122,131,144,155,164,173,186,199,208,221,233,241,249,257,269,282,294,306,318,330,342,355,367,379,387,399,411,423,435,447,455,467,475,487,495,507,519,531,543,555,567],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1035604,2,"多选题","2组高频开关电源的模块数量为（）块。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1；",false,{"key":24,"text":25,"correct":26},"B","2;",true,{"key":28,"text":29,"correct":22},"C","3；",{"key":31,"text":32,"correct":22},"D","4。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1035607,"UPS电源容量选择。某变电所采用交流操作电源（交流220V),其断路器为真空断 路器，经常负荷容量为300VA,每台断路器分合闸容量为500VA,可靠系数为1. 2。试选 择UPS电源容量。 事故操作时所需UPS电源容量为（）， A. 960VA； B 1200VA； C 1500VA； D. 1800VA,",[38,39,40,41],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":28,"analysis":33},1035611,"UPS电源容量选择。某变电所采用交流操作电源（交流220V),其断路器为真空断 路器，经常负荷容量为300VA,每台断路器分合闸容量为500VA,可靠系数为1. 2。试选 择UPS电源容量。 一般UPS电源容量不宜超过（ )。",[46,48,50,52],{"key":20,"text":47,"correct":22},"1500VA;",{"key":24,"text":49,"correct":22},"2500VA;",{"key":28,"text":51,"correct":26},"3000VA",{"key":31,"text":53,"correct":22},"3500V",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":20,"analysis":33},1035614,"已知蓄电池额定容量为200Ah,直流系统经常负荷为25A,试计算该直流系统的充 电装置额定电流并应满足浮充电、初充电、均衡充电要求。 蓄电池放电试验装置电流为（ ）。",[58,60,62,64],{"key":20,"text":59,"correct":26},"26A；",{"key":24,"text":61,"correct":22},"27A;",{"key":28,"text":63,"correct":22},"28A;",{"key":31,"text":65,"correct":22},"29",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":31,"analysis":33},1035617,"UPS电源容量选择。某变电所采用交流操作电源（交流220V),其断路器为真空断 路器，经常负荷容量为300VA,每台断路器分合闸容量为500VA,可靠系数为1. 2。试选 择UPS电源容量。",[70,72,74,76],{"key":20,"text":71,"correct":22},"UPS电源额定容量应选（ ）。",{"key":24,"text":73,"correct":22},"1200VA；",{"key":28,"text":75,"correct":22},"1500VA； C 1800VA；",{"key":31,"text":77,"correct":26},"2200V",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":24,"analysis":33},1035619,"UPS电源容量选择。某变电所采用交流操作电源（交流220V),其断路器为真空断 路器，经常负荷容量为300VA,每台断路器分合闸容量为500VA,可靠系数为1. 2。试选 择UPS电源容量。 正常操作时所需UPS电源容量为（ ）。",[82,84,86,87],{"key":20,"text":83,"correct":22},"800VA；",{"key":24,"text":85,"correct":26},"960VA；",{"key":28,"text":73,"correct":22},{"key":31,"text":88,"correct":22},"1500V",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":31,"analysis":33},1035622,"已知蓄电池额定容量为200Ah,直流系统经常负荷为25A,试计算该直流系统的充 电装置额定电流并应满足浮充电、初充电、均衡充电要求。 充电装置的额定电流应为（ ）。",[93,95,97,99],{"key":20,"text":94,"correct":22},"25A；",{"key":24,"text":96,"correct":22},"30A；",{"key":28,"text":98,"correct":22},"40A；",{"key":31,"text":100,"correct":26},"50",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":31,"analysis":33},1035623,"已知蓄电池额定容量为200Ah,直流系统经常负荷为25A,试计算该直流系统的充 电装置额定电流并应满足浮充电、初充电、均衡充电要求。",[105,107,109,110],{"key":20,"text":106,"correct":22},"满足均衡充电要求的电流为（）",{"key":24,"text":108,"correct":22},"25A；B30A;",{"key":28,"text":98,"correct":22},{"key":31,"text":100,"correct":26},{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":20,"analysis":33},1035626,"已知蓄电池额定容量为200Ah,直流系统经常负荷为25A,试计算该直流系统的充 电装置额定电流并应满足浮充电、初充电、均衡充电要求。 满足初充电要求的电流为（ )。",[115,117,119,120],{"key":20,"text":116,"correct":26},"25A;",{"key":24,"text":118,"correct":22},"26A;",{"key":28,"text":61,"correct":22},{"key":31,"text":121,"correct":22},"28",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":20,"analysis":33},1035629,"已知蓄电池额定容量为200Ah,直流系统经常负荷为25A,试计算该直流系统的充 电装置额定电流并应满足浮充电、初充电、均衡充电要求。 满足浮充电要求的电流为（ ）.",[126,127,128,130],{"key":20,"text":94,"correct":26},{"key":24,"text":59,"correct":22},{"key":28,"text":129,"correct":22},"27A；",{"key":31,"text":121,"correct":22},{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":143,"analysis":33},1035632,"系统运行中出现于设备绝缘上的电压有（ ）。",[135,137,139,141],{"key":20,"text":136,"correct":26},"工频运行电压；",{"key":24,"text":138,"correct":26},"暂时过电压；",{"key":28,"text":140,"correct":26},"操作过电压；",{"key":31,"text":142,"correct":26},"雷电过电压。","ABCD",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":154,"analysis":33},1035635,"属于暂时过电压的有（ )。",[148,150,152,153],{"key":20,"text":149,"correct":26},"工频过电压；",{"key":24,"text":151,"correct":26},"谐振过电压；",{"key":28,"text":140,"correct":22},{"key":31,"text":142,"correct":22},"AB",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":163,"analysis":33},1035637,"关于交流电气装置过电压的标幺值，正确的是（ ）。",[159,160,161,162],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},"AD",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":172,"analysis":33},1035640,"电力系统工频过电压的标幺值一般不超过（ ）。",[168,169,170,171],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},"ACD",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":185,"analysis":33},1035641,"在进行绝缘配合时，相对地计算用最大操作过电压的标幺值应取（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":26},"110 kV 系统：3.0 p. u.；",{"key":24,"text":180,"correct":26},"66kV及以下系统（低电阻接地除外）：4. Op. u.;",{"key":28,"text":182,"correct":22},"3~10 kV系统（低电阻接地除外）：3. 5 p. u.；",{"key":31,"text":184,"correct":26},"35 kV及以下低电阻接地系统：3. 2 p. u.。","ABD",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":198,"analysis":33},1035644,"电力规范关于雷电活动分区，下列正确的是（ ）。",[190,192,194,196],{"key":20,"text":191,"correct":22},"少雷区是平均年雷暴日不超过20的地区；",{"key":24,"text":193,"correct":22},"中雷区是平均年雷暴日超过20但不超过40的地区；",{"key":28,"text":195,"correct":26},"多雷区是平均年雷暴日超过40但不超过90的地区；",{"key":31,"text":197,"correct":26},"雷电活动特殊强烈地区是平均年雷暴日超过90的地区及根据运行经验雷害特殊严重 的地区。","CD",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":207,"analysis":33},1035646,"关于架空线路上的雷电过电压，下列正确的是（ ）。",[203,204,205,206],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},"AC",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":220,"analysis":33},1035649,"变电所内的雷电过电压来自雷电对配电装置的直接雷击、反击和架空进线上出现的 雷电侵人波。下列防护措施正确的是（）。 A.应该采用避雷针或避雷线对户外高压配电装置进行直击雷保护并采取措施防止反",[212,214,216,218],{"key":20,"text":213,"correct":26},"击；",{"key":24,"text":215,"correct":26},"应该采取措施防止或减少变电所近区线路的雷击闪络，并在所内适当配置阀式避雷 器以减少雷电侵入波过电压的危害；",{"key":28,"text":217,"correct":26},"对采用的雷电侵入波过电压保护方案校验时，一般应该保证2km外线路导线上出现 雷电侵入波过电压时，不引起变电所电气设备绝缘损坏；",{"key":31,"text":219,"correct":22},"对采用的雷电侵入波过电压保护方案校验时，一般应该保证1km外线路导线上出现 雷电侵入波过电压时，不引起变电所电气设备绝缘损坏。","ABC",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":154,"analysis":33},1035651,"变电所的直击雷过电压保护可采用避雷针、避雷线。下列设施应装设直击雷保护装 置的是（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":26},"屋外配电装置，包括母线廊道；",{"key":24,"text":228,"correct":26},"油处理室、燃油泵房、露天油罐及其架空管道、装卸油台、易燃材料仓库等建筑物；",{"key":28,"text":230,"correct":22},"独立的主控制室屋顶及35kV及以下变电所屋顶；",{"key":31,"text":232,"correct":22},"露天布置的GIS外壳.",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":185,"analysis":33},1035653,"在配电装置的架构或屋顶上装设避雷针的条件是（）。",[237,238,239,240],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":243,"answer":248,"analysis":33},1035656,[244,245,246,247],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},"BCD",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":248,"analysis":33},1035658,"将线路避雷线引接到变电所出线门型架构上的条件是（）。",[253,254,255,256],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":220,"analysis":33},1035660,"发电厂和变电所有爆炸危险且爆炸后可能波及发电厂和变电所主要设备或严重影 响发供电的建、构筑物，应采用独立避雷针保护，并应采取防止雷电感应的措施。下列要求 中正确的是（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":26},"避雷针与呼吸阀的水平距离不应小于3m,但5000m3以上贮罐则不应小于5m;",{"key":24,"text":264,"correct":26},"避雷针的保护范围边缘高出呼吸阀顶部不应小于2m,对5000m3以上贮罐则避雷针 尖高出呼吸阀不应小于5m;",{"key":28,"text":266,"correct":26},"C在非高土壤电阻率地区，避雷针的接地电阻不宜大于1On;",{"key":31,"text":268,"correct":22},"露天贮罐应设集中接地体，一点接地。",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":281,"analysis":33},1035663,"在装有避雷针、避雷线的架构上敷设电气线路，下列正确的是（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":22},"不宜在装有避雷针、避雷线的构筑物上架设未采取保护措施的通信线、广播线和低 压线；",{"key":24,"text":276,"correct":26},"必须采用直接埋地的带金属外皮的电缆或穿入金属管的导线；",{"key":28,"text":278,"correct":22},"当电缆外皮或金属管埋地长度在5m以上时，才允许与35kV及以下配电装置的接地 网及低压配电装置相连接；",{"key":31,"text":280,"correct":26},"当电缆外皮或金属管埋地长度在1Om以上时，才允许与35kV及以下配电装置的接 地网及低压配电装置相连接。","BD",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":172,"analysis":33},1035666,"连接35kV及以上架空进线的变电所高压配电装置，防雷电侵入波过电压保护应符 合（)。 A.未沿全线架设避雷线的35~IlOkV线路，应在变电所1~2km的进线段架设避雷",[286,288,290,292],{"key":20,"text":287,"correct":26},"线；",{"key":24,"text":289,"correct":22},"全线架设避雷线时，变电所母线上可不装设阀式避雷器；",{"key":28,"text":291,"correct":26},"C变电所母线上应装设1组阀式避雷器；",{"key":31,"text":293,"correct":26},"进线开关在雷季可能经常断路运行时，应在其外侧装设一组排气式避雷器或阀式避 雷器。",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":220,"analysis":33},1035669,"连接35kV及以上电缆进线段的变电所高压配电装置，防雷电侵入波过电压保护应 符合（）。",[298,300,302,304],{"key":20,"text":299,"correct":26},"在电缆与架空线的连接处应装设阀式避雷器；",{"key":24,"text":301,"correct":26},"如电缆长度不超过50m或虽超过50m,但经校验，装1组阀式避雷器即可满足保护 要求时，可只在电缆首端或变电所母线上装设1組阀式避雷器；",{"key":28,"text":303,"correct":26},"C如电缆长度超过50m,且断路器在雷季可能经常断路运行，则还应在电缆束端装设 排气式避雷器或阀式避雷器；",{"key":31,"text":305,"correct":22},"连接电缆段的500m架空线路应架设避雷线。",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":185,"analysis":33},1035671,"在变电所中变压器中性点装设雷电过电压保护装置（避雷器〉的条件是（ ）。 A.在有效接地系统的中性点不接地的变压器，其中性点为分级绝缘且未装设保护间隙",[310,312,314,316],{"key":20,"text":311,"correct":26},"时；",{"key":24,"text":313,"correct":26},"在有效接地系统的中性点不接地的变压器，其中性点为全绝缘，但变电所为单进线、 单台变压器运行时；",{"key":28,"text":315,"correct":22},"不接地、消弧线圈接地和高电阻接地系统中的变压器；",{"key":31,"text":317,"correct":26},"有单进线运行可能时，中性点接有消弧线囷的变压器。",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":143,"analysis":33},1035673,"有架空进线的3~1OkV变配电所的配电装置（包括电力变压器），防雷电侵入波过 电压保护措施，正确的是（）。",[322,324,326,328],{"key":20,"text":323,"correct":26},"应在每組母线和架空进线上分别装设电站型和配电型阀式避雷器，母线上阀式避雷 器至变压器的最大电气距离：1路架空进线为15m,每増加1路増加5m, 4路及以上为 30m。 -",{"key":24,"text":325,"correct":26},"B有电缆进线段的架空线路，阀式避雷器应装设在电缆头附近，其接地端应和电缆金 属外皮相连。如各架空进线均有电缆段，则阀式避雷器与主变压器的最大电气距离不受限 制。",{"key":28,"text":327,"correct":26},"阀式避雷器应以最短的接地线与变配电所的主接地网连接（包括通过电缆金属外皮 连接）。阀式避雷器接地点应装设集中接地装置。",{"key":31,"text":329,"correct":26},"3~1OkV配电所，当无所用变压器时，可仅在每路架空进线上装设阀式避器。",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":220,"analysis":33},1035676,"3~1OkV配电系统的雷电过电压保护，正确的是（）。",[334,336,338,340],{"key":20,"text":335,"correct":26},"配电变压器、柱上断路器和负荷开关，应装设阀式避雷器保护；",{"key":24,"text":337,"correct":26},"B装设在架空线路上的电容器，宜装设阀式避雷器保护；",{"key":28,"text":339,"correct":26},"Yyn和Yy接线变压器的低压側，宜装设1组阀式避雷器或击穿保险器；",{"key":31,"text":341,"correct":22},"IT系统中配电变压器的中性点，宜装设阀式避雷器保护.",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":354,"analysis":33},1035679,"3~1OkV钢筋混凝土杆架空配电线路雷电过电压保护措施，下列正确的是（ ）。",[346,348,350,352],{"key":20,"text":347,"correct":22},"除少雷区外，宜采用铁横担，对供电可靠性要求高的线路宜采用高一级电压等级的 绝缘子。",{"key":24,"text":349,"correct":26},"除少雷区外，宜采用瓷或其他绝缘材料的横担；如用铁横担，对供电可靠性要求高 的线路宜采用高一级电压等级的绝缘子。",{"key":28,"text":351,"correct":26},"铁横担与绝缘子固定部分或瓷横担固定部分之间，宜有可靠的电气连接并与接地引 下线相连。",{"key":31,"text":353,"correct":22},"与架空线路相连接的长度不超过50m的电缆，应在其两端装设阀式避雷器或保护间隙。","BC",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":198,"analysis":33},1035681,"按开断续流的范围选择排气式避雷器，下列正确的是（ ）。",[359,361,363,365],{"key":20,"text":360,"correct":22},"其开断续流的上限，不考虑非周期分量，不得小于安装处短路电流的最小有效值；",{"key":24,"text":362,"correct":22},"其开断续流的下限，考虑非周期分量，不得小于安装处短路电流的可能最小值；",{"key":28,"text":364,"correct":26},"其开断续流的上限，考虑非周期分量，不得小于安装处叛路电流的最大有效值",{"key":31,"text":366,"correct":26},"其开断续流的下限，不考虑非周期分量，不得大于安装处短路电流的可能最小值。",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":172,"analysis":33},1035683,"3~66kV不接地系统或消弧线圈接地系统偶然脱离消弧线圈的部分，当连接有中 性点接地的电磁式电压互感器的空载母线，因合闸充电或运行中接地故障消除等原因，可能 产生铁磁谐振过电压，为限制这类过电压，可选取的措施有（ ）。",[371,373,375,377],{"key":20,"text":372,"correct":26},"选用励磁特性饱和点较高的电磁式电压互感器；",{"key":24,"text":374,"correct":22},"1OkV及以下电压互感器高压绕组中性点均应直接接地；",{"key":28,"text":376,"correct":26},"10kV及以下电压互感器高压绕组中性点经电阻接地；",{"key":31,"text":378,"correct":26},"在互感器的开口三角形绕组装设电阻或专用消谐装置。",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":354,"analysis":33},1035686,"在3~66kV系统中，为限制开断并联电容补偿装置时断路器发生重击穿而产生的 过电压，可选取的措施有（ ）. A.限制并联电容补偿装置的容量；B采用开断时不重击穿的断路器； C装设金属氧化物避雷器； D.装设差动速断保护。",[383,384,385,386],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":354,"analysis":33},1035688,"下列属于第二类防雷建筑物的是（）。",[391,393,395,397],{"key":20,"text":392,"correct":22},"省级重点文物保护的建筑物及省级档案馆；",{"key":24,"text":394,"correct":26},"B预计雷击次数大于0.06次\u002F年的部、省级办公建筑物及其他重要或人员密集的公共 建筑物；",{"key":28,"text":396,"correct":26},"预计雷击次数大于0.3次\u002F年的住宅、办公楼等一般性民用建筑物；",{"key":31,"text":398,"correct":22},"年平均雷暴日大于15天\u002F年的地区，高度在20m及以上的烟囱、水塔等孤立的高耸 建筑物。",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":281,"analysis":33},1035693,"下列属于第三类防雷建筑物的是（）。",[403,405,407,409],{"key":20,"text":404,"correct":22},"年平均雷暴日大于15天\u002F年地区的一般性工业建筑物；",{"key":24,"text":406,"correct":26},"B预计雷击次数大于或等于o.o6次\u002F年的一般性工业建筑物；",{"key":28,"text":408,"correct":22},"C具有2区或11区爆炸危险环境的建筑物；",{"key":31,"text":410,"correct":26},"根据雷击后对工业生产的影响及产生的后果，并结合当地气象、地形、地质及周围 环境等因素，确定需要防雷的火灾危险坏境。",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":143,"analysis":33},1035696,"各类防雷建筑物除应采取防直击雷和防雷电波侵入的措施外，下述建筑物中 ( )尚应采取防雷电感应的措施。",[415,417,419,421],{"key":20,"text":416,"correct":26},"第一类防雷建筑物；",{"key":24,"text":418,"correct":26},"B制造、使用或贮存爆炸物质的建筑物，且电火花不易引起爆炸或不致造成巨大破坏 和人身伤亡者;",{"key":28,"text":420,"correct":26},"具有1区爆炸危险环境的建筑物，且电火花不易引起爆炸或不致造成巨大破坏和人 身伤亡者；",{"key":31,"text":422,"correct":26},"具有2区或11区爆炸危险环境的建筑物。",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":143,"analysis":33},1035699,"第一类防雷建筑物的防直击雷措施，一般装设独立避雷针或架空避雷网.当建筑 物太髙或其他原因难以实施时，可将避雷针或网格不大于5mX5m或4mX6m的避雷网直 接装在建筑物上，尚应符合（）。",[427,429,431,433],{"key":20,"text":428,"correct":26},"引下线不应少于2 根，并应沿建筑物四周均匀或对称布置，其间距不应大于12m;",{"key":24,"text":430,"correct":26},"B建筑物应装设均压环，所有引下线、建筑物的金属结构和金属设备均应连到环上， 环间垂直距离不应大于12m;",{"key":28,"text":432,"correct":26},"C防直去雷的接地装置应围绕建筑物敷设成环形接地体，每根引下线的冲击接地电阻 不应大于10n;",{"key":31,"text":434,"correct":26},"当建筑物高于30m时，应采取以下防侧击雷的措施：从30m起每隔不大于6m沿建 筑物四周设水平避雷带并与引下线相连，30m及以上外墙上的栏杆、门窗等较大的金属物 与防雷装置连接。",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":163,"analysis":33},1035701,"第一类防雷建筑物和具有爆炸危险环境的第二类防雷建筑物，应采取的防雷电感 应措施包括（ ）。",[439,441,443,445],{"key":20,"text":440,"correct":26},"建筑物内的设备、管道、构架、电缆金属外皮、钢屋架、钢窗等较长大金属物和突 出屋面的金属放散管、风管等均应就近连接到防雷电感应或共用接地装置上；",{"key":24,"text":442,"correct":22},"当管道、构架、电缆金属外皮等长金属物，其平行或交叉敷设的净距小于150mm时 应采用金属线跨接，跨接点的间距不应大于35m;",{"key":28,"text":444,"correct":22},"当长金属物的弯头、阀门、法兰盘等连接处的过渡电阻大于0.3n时，连接处应用 金属线跨接，但第二类防雷建筑物可不跨接；",{"key":31,"text":446,"correct":26},"防雷电感应的接地干线与接地装置的连接不应少于2处，第一类防雷建筑物防雷电 感应的接地装置与独立避雷针等接闪器的接地装置之间的间隔距离应符合相关要求。",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":198,"analysis":33},1035703,"第二、三类防雷建筑物防直击雷接地装置的要求，下列正确的是（）。",[451,452,453,454],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":281,"analysis":33},1035706,"下列建筑物中不宜利用钢筋混凝土屋面内的钢筋作为接闪器的是（ ）。 A.国家级的会堂、办公、大型展览和博览建筑物、大型火车站和机场、国宾馆、国家 级档案馆、大型城市的重要给水水泵房等特别重要的建筑物；",[459,461,463,465],{"key":20,"text":460,"correct":22},"国家级重点文物保护的建筑物；",{"key":24,"text":462,"correct":26},"C国家级计算中心、国际通信枢纽等对国民经济有重要意义且装设有大量电子设备的",{"key":28,"text":464,"correct":22},"建筑物；",{"key":31,"text":466,"correct":26},"具有爆炸危险环境的第二类防雷建筑物。",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":207,"analysis":33},1035708,"第二类防雷建筑物，当在建筑物周边的无钢筋的闭合条形混凝土基础内敷设人工 基础接地体时，接地体的最小规格尺寸符合要求的是（ ）。",[471,472,473,474],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":220,"analysis":33},1035711,"当利用建筑物的结构钢筋作为防雷装置时，对钢筋连接的要求，下列合乎要求的 做法是（ ）。",[479,481,483,485],{"key":20,"text":480,"correct":26},"构件内有箍筋连接的钢筋，其箍筋与钢筋的连接或成网状的钢筋与钢筋的连接，采 用土建施工的绑扎法连接；",{"key":24,"text":482,"correct":26},"B长度方向主钢筋之间的连接，采用土建施工的螺丝扣连接或焊接；",{"key":28,"text":484,"correct":26},"单根钢筋或圆钢或外引预埋连接板、线与结构钢筋的连接采用焊接或螺栓紧固的卡 夹器连接；",{"key":31,"text":486,"correct":22},"构件之间不要求连接成电气通路。",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":248,"analysis":33},1035713,"第二类防雷建筑物，在防雷的接地装置同其他接地装置和进出建筑物的管道相连 的情况下，对6m柱距或大多数柱距为6m的单层工业建筑物，当利用柱子基础的钢筋作为 外部防雷装置的接地体并符合下列条件（）时，可不另加接地体。",[491,492,493,494],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":163,"analysis":33},1035716,"各防雷类别的高层建筑物应采取防雷电侧击的保护措施，下列正确的是：应将 ()及以上外墙上的栏杆、门窗等较大的金属物与防雷装置连接。",[499,501,503,505],{"key":20,"text":500,"correct":26},"一类防雷建筑物30m;",{"key":24,"text":502,"correct":22},"二类防雷建筑物45m;",{"key":28,"text":504,"correct":22},"三类防雷建筑物50m;",{"key":31,"text":506,"correct":26},"其他防雷建筑物60m。",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":248,"analysis":33},1035719,"为防雷电波沿各种金属管道侵入建筑物内，下列正确的是（ ）。 A.进出第一类防雷建筑物的架空金属管道，在距建筑物50m内，应每隔25m左右接 地一次，其冲击接地电阻不应大于10n;",[511,513,515,517],{"key":20,"text":512,"correct":22},"B进出有爆炸危险环境的第二类防雷建筑物的架空金属管道，应在距建筑物25m处接",{"key":24,"text":514,"correct":26},"地一次，其冲击接地电阻不应大于10n;",{"key":28,"text":516,"correct":26},"进出第一、二类防雷建筑物的架空或埋地金属管道，在进出处应就近与防雷电感应\u002F 防雷的接地装置相连;",{"key":31,"text":518,"correct":26},"进出第三类防雷建筑物的架空金属管道，在进出处应就近接到防雷或电气设备共用 接地装置上或独自接地，其冲击接地电阻不宜大于30n.",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":143,"analysis":33},1035720,"当一座防雷建筑物中兼有第一、二、三类防雷建筑物时，其防雷分类和防雷措施, 下列正确的是（ ）.",[523,525,527,529],{"key":20,"text":524,"correct":26},"当第一类防雷建筑物部分的面积占建筑物总面积的30%及以上时，该建筑物宜确定 为第一类防雷建筑物；",{"key":24,"text":526,"correct":26},"B当第一类防雷建筑物部分的面积占建筑物总面积的30%以下，且第二类防雷建筑物 部分的面积占建筑物总面积的30%及以上时，或当这两类防雷建筑物部分的面积均小于建 筑物总面积的30%,但其面积之和又大于30%时，该建筑物宜确定为第二类防雷建筑物；",{"key":28,"text":528,"correct":26},"当第一、二类防雷建筑物部分的面积之和小于建筑物总面积的30%,且不可能遭直 接雷击时，该建筑物可确定为第三类防雷建筑物，当可能遭直接雷击时，宜按各自类别采取 防雷措施；",{"key":31,"text":530,"correct":26},"对第一、二类防雷建筑物部分的防雷电感应和防雷电波侵入，应采取各自类别的保 护措施.",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":248,"analysis":33},1035722,"有爆炸危险的露天封闭钢罐的防雷措施，下列正确的是（ ）。",[535,537,539,541],{"key":20,"text":536,"correct":22},"当其壁厚大于4mm时，可不采取防雷措施；",{"key":24,"text":538,"correct":26},"当其壁厚小于4mm时，应采用接闪器防护，其外表面的2区爆炸危险环境可不在滚 球法确定的保护范围内；",{"key":28,"text":540,"correct":26},"当其壁厚不小于4mm时，可不装设接闪器，但应将罐体接地，且接地点不应少于2 处，两接地点间距离不宜大于30m,冲击接地电阻不应大于30n;",{"key":31,"text":542,"correct":26},"其放散管和呼吸阀的管口或管帽应处于接闪器保护范围内，并应符合第一类防雷建 筑物的相关要求；引出\u002F入罐体的金属管道应在法兰等接头处做好电气连接。",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":185,"analysis":33},1035725,"固定在建筑物上的节日彩灯、航空障碍信号灯及其他用电设备的线路防止雷电波 侵人的措施，下列正确的是（ ）。",[547,549,551,553],{"key":20,"text":548,"correct":26},"无金属外壳或保护网罩的用电设备宜处在接闪器的保护范围内，不宜布置在避雷网 之外，并不宜高出避雷网；",{"key":24,"text":550,"correct":26},"从配电盘引出的线路穿钢管敷设，钢管的一端与配电盘金属外壳相连，另一端与用 电设备金属外壳、保护罩相连，并就近与屋顶防雷装置相连，当钢管因连接设备而中间断开 时加设跨接线；",{"key":28,"text":552,"correct":22},"从配电盘引出的线路穿塑料绝缘管保护，但在配电盘母线上应装设过电压保护器；",{"key":31,"text":554,"correct":26},"在配电盘内出线开关的电源侧与外壳之间装设过电压保护器。",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":220,"analysis":33},1035728,"建筑物防雷接闪器可由下列（ ）中的一种或多种组成。",[559,561,563,565],{"key":20,"text":560,"correct":26},"独立避雷针；",{"key":24,"text":562,"correct":26},"B架空避雷线或架空避雷网；",{"key":28,"text":564,"correct":26},"c直接装设在建筑物上的避雷针、避雷带或避雷网；",{"key":31,"text":566,"correct":22},"无线电视广播的共用天线的金属杆。",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":163,"analysis":33},1035730,"在220\u002F380V三相系统中电涌保护器SPD的安装，下列正确的是（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":26},"在TN系统中，在N线与PE线连接处，应在3根相线与PE线间装设SPD;",{"key":24,"text":574,"correct":22},"在TN系统中，在N线与PE线分开处，应在3根相线与N线间及N线与PE线间 装设SPD;",{"key":28,"text":576,"correct":22},"在TT系统中，当SPD安装在剩余电流保护器的电源侧时，应在3根相线与PE线 间及N线与PE线间装设SPD；",{"key":31,"text":578,"correct":26},"在IT系统中，应在3根相线与PE线间装设SPD。",[580,584,587,590,593,596],{"id":581,"name":582,"category":7,"favorite":583},1,"领导干部任职前廉政法规知识测试题",92,{"id":585,"name":586,"category":7,"favorite":581},595,"建筑结构与设备",{"id":588,"name":589,"category":7,"favorite":581},715,"招标采购专业知识与法律法规",{"id":591,"name":592,"category":7,"favorite":581},848,"市政方向-通用基础",{"id":594,"name":595,"category":7,"favorite":8},534,"BIM工程师",{"id":597,"name":595,"category":7,"favorite":8},535]