[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-40":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":579},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,40,50,2321,[13,35,48,61,74,87,100,113,121,134,146,158,170,182,194,206,218,230,242,250,263,275,287,295,307,319,331,340,352,364,376,388,400,412,424,436,448,456,465,473,485,497,505,512,519,531,538,549,558,569],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1035468,2,"多选题","强电控制一般分为（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","根据控制地点分为远方控制和就地控制两种；",false,{"key":24,"text":25,"correct":26},"B","根据控制地点分为集中控制和就地控制两种；",true,{"key":28,"text":29,"correct":26},"C","按跳、合闸回路监视方式分为灯光监视和音响监视两种；",{"key":31,"text":32,"correct":26},"D","按控制回路接线分为控制开关具有固定位置的不对应接线与控制开关自动复位的 接线。","BCD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1035471,"采用定型标准2200mm高的屏（屏台）时，下列屏面设备布置尺寸正确的是（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":26},"仪表的水平中心线宜距地面1200~2000mm;",{"key":24,"text":42,"correct":22},"电能表的氷平中心线宜距地面1500~2100mm;",{"key":28,"text":44,"correct":26},"操作、切换开关按布置在水平中心线距地面高度800~1600mm之间；",{"key":31,"text":46,"correct":26},"光字牌布置的水平中心线距地面高度应在1400~1700mm之间。","ACD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},1035474,"关于屏面布置的要求，正确的说法是（ ）。",[52,54,56,58],{"key":20,"text":53,"correct":26},"同类安装单位的屏面布置虚应一致，当不同安装单位的设备安装在同一块屏（台〉上 时，宜按纵向划分；",{"key":24,"text":55,"correct":22},"同类安装单位的屏面布置宜一致，两个不同安装单位设备应按纵向划分；",{"key":28,"text":57,"correct":26},"同一块屏面上的设备纵向，横向安装单位设备位置应一致，并考虑运行、維护、检 修方便；",{"key":31,"text":59,"correct":22},"以上均不正确。","AC",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},1035477,"中央信号装置可分为（ ）。",[65,67,69,71],{"key":20,"text":66,"correct":22},"中央信号能重复动作；",{"key":24,"text":68,"correct":26},"中央信号复归不重复动作；",{"key":28,"text":70,"correct":26},"中央信号复归能重复动作；",{"key":31,"text":72,"correct":22},"中央信号不重复动作。","BC",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":86,"analysis":34},1035480,"属于多功能电能表功能的是（ ）。",[78,80,82,84],{"key":20,"text":79,"correct":26},"计量有功（无功〉电能；",{"key":24,"text":81,"correct":26},"具有分时、分方向需量；",{"key":28,"text":83,"correct":26},"显示、储存和输出；",{"key":31,"text":85,"correct":22},"显示全天、全月总功量。","ABC",{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":99,"analysis":34},1035483,"下列电流互感器中可用于继电保护装置的是（ ）级。",[91,93,95,97],{"key":20,"text":92,"correct":22},"0.2;",{"key":24,"text":94,"correct":22},"0.5；",{"key":28,"text":96,"correct":26},"P；",{"key":31,"text":98,"correct":26},"TP。","CD",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":112,"analysis":34},1035485,"自动投人装置应符合的要求有（ 〉。",[104,106,108,110],{"key":20,"text":105,"correct":26},"应保证在工作电源或设备断开后，才投入备用电源或设备；",{"key":24,"text":107,"correct":22},"应保证工作电源或设备完好的情况下，才投入备用电源；",{"key":28,"text":109,"correct":22},"C工作电源或设备上的电压，不论因任何原因消失时，自动投入装置均应动作;",{"key":31,"text":111,"correct":26},"自动投入装置应保证只动作一次。","AD",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":60,"analysis":34},1035487,"( )容量的变压器，应装瓦斯保护。 A. O. 8MVA及以上的油浸式变压器； B. 1. OMVA及以上的油浸式变压器； C 0.4MVA及以上的车间内油浸式变压器； D. 0.63MVA及以上的车间内油浸式变压器。",[117,118,119,120],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":133,"analysis":34},1035490,"对变压器、引出线、套管及内部的短路故障，按规定，（ ）容量的变压器，应装 纵联差动作为主保护。",[125,127,129,131],{"key":20,"text":126,"correct":26},"1OMVA及以上单独运行的变压器；",{"key":24,"text":128,"correct":26},"6. 3MVA及以上并列运行的变压器；",{"key":28,"text":130,"correct":26},"6. 3MVA及以下单独运行的重要变压器；",{"key":31,"text":132,"correct":26},"2MVA及以上变压器，当电流速断灵敏系数不符合要求时;","ABCD",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":33,"analysis":34},1035493,"变压器采用纵联差动保护时，按（ ）确定保护装置的一次动作电流。",[138,140,142,144],{"key":20,"text":139,"correct":22},"躲过电动机自启动的最大工作电流；",{"key":24,"text":141,"correct":26},"躲过励磁涌流；",{"key":28,"text":143,"correct":26},"C躲过外部短路产生的不平衡电流；",{"key":31,"text":145,"correct":26},"躲过电流互感器二次因路断线时的最大负荷电流.",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":33,"analysis":34},1035496,"对由外部相间短路引起的变压器过电流，按( )规定装设相应保护作为后备 保护.",[150,152,154,156],{"key":20,"text":151,"correct":22},"单相式低电压启动过电流用于降压变压器；",{"key":24,"text":153,"correct":26},"复合电压启动的过电流保护，宜用于升压变压器、系统联络变压器、过电流保护不 符合要求的降压变压器；",{"key":28,"text":155,"correct":26},"6.3MVA及以上升压变压器，可采用负序电流和单相式低电压启动过电流保护；",{"key":31,"text":157,"correct":26},"当以上选项不能满足灵敏度和选择性要求时，可采用阻抗保护。",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":33,"analysis":34},1035499,"一次电压为1OkV及以下，绕组为星形星形接线，低压侧中性点直接接地的变压 器，对低压侧单相接地短路应装设下列（ ）保护之一。",[162,164,166,168],{"key":20,"text":163,"correct":22},"零序电流电压保护；",{"key":24,"text":165,"correct":26},"接于低压侧的三相电流保护；",{"key":28,"text":167,"correct":26},"接于低压侧中性线上的零序电流保护；",{"key":31,"text":169,"correct":26},"利用高压侧的三相式过电流保护。",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":99,"analysis":34},1035502,"对由外部相间短路引起的变压器过电流，正确的保护配置是（ )。",[174,176,178,180],{"key":20,"text":175,"correct":22},"过电流保护宜用于升压变压器；",{"key":24,"text":177,"correct":22},"复合电压（含负序电压及线电压）启动的过电流保护，宜用于降压变压器；",{"key":28,"text":179,"correct":26},"负序电流和单相式低电压启动的过电流保护，可用于6.3MVA及以上升压变压器；",{"key":31,"text":181,"correct":26},"当以上保护不能满足灵敏性和选择性要求时，可采用阻抗保护。",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":99,"analysis":34},1035504,"( )电动机应装设过负荷保护。",[186,188,190,192],{"key":20,"text":187,"correct":22},"高压电动机（3kV及以上）；",{"key":24,"text":189,"correct":22},"短时断续工作的低压电动机；",{"key":28,"text":191,"correct":26},"易过负荷的电动机；",{"key":31,"text":193,"correct":26},"需要防止启动或自启动时间过长的电动机。",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":86,"analysis":34},1035506,"( )应装设低电压保护.",[198,200,202,204],{"key":20,"text":199,"correct":26},"当电源电压短时降低或短时中断后，为保证重要电动机自启动而需要断开的次要电 动机；",{"key":24,"text":201,"correct":26},"当电源电压短时降低或短时中断后，不允许或不需要自启动的电动机；",{"key":28,"text":203,"correct":26},"需要自启动，但为保证人身和设备安全，在电源电压长时间消失后，须从电力网中自动断开的电动机；",{"key":31,"text":205,"correct":22},"I类负荷电动机。",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":73,"analysis":34},1035509,"6300kVA以下高压厂用变压器（带一段母线）电流速断保护装置配置应为（ ）。",[210,212,214,216],{"key":20,"text":211,"correct":22},"两相二继电器式；",{"key":24,"text":213,"correct":26},"两相三继电器式；",{"key":28,"text":215,"correct":26},"三相三继电器式；",{"key":31,"text":217,"correct":22},"三相二继电器式.",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":60,"analysis":34},1035512,"请从以下五个方面对变配电所微机监控系统的硬件作出选择： 监控系统分为（ ）和（ ）两部分。",[222,224,226,228],{"key":20,"text":223,"correct":26},"站控层；",{"key":24,"text":225,"correct":22},"设备层；",{"key":28,"text":227,"correct":26},"间隔层；",{"key":31,"text":229,"correct":22},"主控层。",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":33,"analysis":34},1035515,"交流电流回路的设计有一些基本要求，下列正确的说法是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":22},"在某些特殊情况下，保护装置和测量仪表必须共用一组电流互感器的同一个二次绕组上，此时测量仪表应接在保护装置之前；",{"key":24,"text":237,"correct":26},"对中性点直接接地系统，可按三相配置电流互感器，对中性点非直接接地系统，依 具体要求可按两相或三相配置；",{"key":28,"text":239,"correct":26},"电流互感器的二次回路不宜进行切换；",{"key":31,"text":241,"correct":26},"1lOkV及以上的电流互感器的额定二次电流宜选1",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":60,"analysis":34},1035518,"变电所操作电源分为（）。 A.直流操作电源；B高频操作电源；C.交流操作电源；D.控制操作电源.",[246,247,248,249],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":262,"analysis":34},1035521,"11OkV及以下变电所的直流负荷类别可分为（ ）.",[254,256,258,260],{"key":20,"text":255,"correct":26},"经常负荷；",{"key":24,"text":257,"correct":26},"事故负荷；",{"key":28,"text":259,"correct":22},"脉动负荷；",{"key":31,"text":261,"correct":26},"冲击负荷.","ABD",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":60,"analysis":34},1035523,"发电厂和变电所直流系统宜采用的接线型式有（ ）。",[267,269,271,273],{"key":20,"text":268,"correct":26},"单母线；",{"key":24,"text":270,"correct":22},"双母线；",{"key":28,"text":272,"correct":26},"单母线分段；",{"key":31,"text":274,"correct":22},"双母线单分段。",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":99,"analysis":34},1035525,"控制负荷、动力负荷和直流事故照明共用蓄电池组的电压可采用（）。",[279,281,283,285],{"key":20,"text":280,"correct":22},"24V；",{"key":24,"text":282,"correct":22},"48V；",{"key":28,"text":284,"correct":26},"110V;",{"key":31,"text":286,"correct":26},"220V。",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":86,"analysis":34},1035528,"事故负荷是变电所失去交流电源时，必须由直流系统供电的负荷，一般包栝下列 ( )处的照明。 A.变电所主控制室； B 6~1OkV屋内配电装置； C. 35kV室内配电装置； D. 1lOkV室外配电装置。",[291,292,293,294],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":73,"analysis":34},1035531,"蓄电池组的容量，应满足（ ）要求。",[299,301,303,305],{"key":20,"text":300,"correct":22},"合闸；",{"key":24,"text":302,"correct":26},"全所故亊停电Ih的放电容量；",{"key":28,"text":304,"correct":26},"事故放电末期最大的冲击负荷容量；",{"key":31,"text":306,"correct":22},"信号.",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":86,"analysis":34},1035534,"当采用蓄电池组作直流电源时，应满足（ ）要求。",[311,313,315,317],{"key":20,"text":312,"correct":26},"由浮充电设备引起的波纹系数不应大于1%;",{"key":24,"text":314,"correct":26},"电压允许波动应控制在额定电压的5%范围内；",{"key":28,"text":316,"correct":26},"放电末期直流母线电压下限不应低于额定电压的85%;",{"key":31,"text":318,"correct":22},"充电后期直流母线电压上限不应高于额定电压的120%。",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":86,"analysis":34},1035537,"发电厂主控制室装设两组相同电压、容量且互联的蓄电池组（动力与控制合用），在 进行蓄电池组负荷统计计算时，下列说法正确的是（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":26},"每组蓄电池按照全部控制负荷的100%统计；",{"key":24,"text":326,"correct":26},"每组蓄电池按照全部直流事故照明负荷的60%统计；",{"key":28,"text":328,"correct":26},"对于动力负荷和通信和远动负荷，宜平均分配在两组蓄电池上；",{"key":31,"text":330,"correct":22},"应考虑互联増加的负荷统计。",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":339,"analysis":34},1035540,"原能源部在总结了国内外经验的基础上，提出了用（）和（ ）来选择蓄电 池容量。 A.电流控制法； B电压控制法； C.容量控制法； D.阶梯负荷计算法。",[335,336,337,338],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},"BD",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":99,"analysis":34},1035543,"浮充电硅整流装置的输出电流应按（）选择。",[344,346,348,350],{"key":20,"text":345,"correct":22},"动力负荷电流之和；",{"key":24,"text":347,"correct":22},"亊故照明负荷电流之和；",{"key":28,"text":349,"correct":26},"C经常负荷电流之和；",{"key":31,"text":351,"correct":26},"蓄电池组自放电电流。",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":33,"analysis":34},1035544,"充电设备的选择应满足的条件有（）。",[356,358,360,362],{"key":20,"text":357,"correct":22},"亊故放电电流之和;",{"key":24,"text":359,"correct":26},"大于初充电电流；",{"key":28,"text":361,"correct":26},"大于亊故放电后的补充电流；",{"key":31,"text":363,"correct":26},"大于核对性放电后的充电电流。",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":112,"analysis":34},1035547,"事故放电末期冲击电流应考虑（ ）。",[368,370,372,374],{"key":20,"text":369,"correct":26},"最大一台断路器的合闸电流；",{"key":24,"text":371,"correct":22},"母差保护动作跳开多台断路器；",{"key":28,"text":373,"correct":22},"C两台断路器以间隔大于0.25s合闸，不按同时考虑；",{"key":31,"text":375,"correct":26},"变电所装有备用电源自动投入，有可能出现两台或多台断路器合闸的情况，应根据 具体情况确定。",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":33,"analysis":34},1035549,"关于事故停电时间，下列说法正确的是（ ）。",[380,382,384,386],{"key":20,"text":381,"correct":22},"无人值班变电所3h;",{"key":24,"text":383,"correct":26},"有人值班变电所lh;",{"key":28,"text":385,"correct":26},"与电力系统相连的发电厂lh;",{"key":31,"text":387,"correct":26},"交流不停电电源装置0.5h。",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":86,"analysis":34},1035552,"直流设备的充电装置的额定电流的选择应满足（ )条件。",[392,394,396,398],{"key":20,"text":393,"correct":26},"满足浮充电流要求；",{"key":24,"text":395,"correct":26},"大于初充电电流;",{"key":28,"text":397,"correct":26},"C大于均衡充电电流；",{"key":31,"text":399,"correct":22},"小于均衡充电电流。",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":339,"analysis":34},1035555,"关于直流配电屏上熔断器熔件和空气断路器热脱扣器的额定电流选择，正确的是 ( ).",[404,406,408,410],{"key":20,"text":405,"correct":22},"对于直流电动机馈线可不考虑电动机起动电流；",{"key":24,"text":407,"correct":26},"B对于控制、信号馈线应按短时最大工作电流选择；",{"key":28,"text":409,"correct":22},"对于电磁型操动机构，按额定合闸电流选择，但熔件的熔断时间应大于断路器固有 合闸时间；",{"key":31,"text":411,"correct":26},"应保证短路时各级保护设备的选择性.",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":133,"analysis":34},1035557,"蓄电池与直流屏之间的联络电缆及动力馈线的电缆截面选择应符合（ ）规定。",[416,418,420,422],{"key":20,"text":417,"correct":26},"蓄电池与直流屏之间的联络电缆长期允许载流量的选择应按蓄电池Ih放电率电流 或亊故放电初期Imin放电电流二者取大者；",{"key":24,"text":419,"correct":26},"B直流动力馈线电缆截面应根据最大负荷电流并按直流母线计算的最低电压和用电设 备的允许电压选择；",{"key":28,"text":421,"correct":26},"C直流屏与直流分电屏电缆截面应根据最大负荷电流选择，电压降宜取額定电压的 0.5%,",{"key":31,"text":423,"correct":26},"电压降应不大于计算允许值，宜取额定电压的1%。",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":262,"analysis":34},1035560,"下列蓄电池组布置方式正确的是（ ）。",[428,430,432,434],{"key":20,"text":429,"correct":26},"蓄电池组宜布置在电气控制楼（主控制楼、网络控制楼、单元控制楼）的底层；",{"key":24,"text":431,"correct":26},"不同容量、不同电压的酸性蓄电池组可以同室布置；",{"key":28,"text":433,"correct":22},"酸性蓄电池和城性蓄电池可以同室布置；",{"key":31,"text":435,"correct":26},"蓄电池組布罝应避开潮湿和多灰尘的地方。",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":86,"analysis":34},1035562,"蓄电池室的布置与安装要求（ ）。",[440,442,444,446],{"key":20,"text":441,"correct":26},"应考虑到与直流屏的相对位置，方便端电池的接线和至直流屏的电缆最短；",{"key":24,"text":443,"correct":26},"B蓄电池室净高不低于3m;",{"key":28,"text":445,"correct":26},"蓄电池引出线一般采用塑料絶缘铜芯电缆，穿硬塑料管埋地敷设，管口用防酸材料 封堵；",{"key":31,"text":447,"correct":22},"母线支持点间的距离不应大于3m。",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":47,"analysis":34},1035565,"交流操作的小型配电所中主要采用（ ）。 A.弹簧储能操动机构; B.由电压互感器供电； C.直动式继电器； D去分流方式分闸.",[452,453,454,455],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":464,"analysis":34},1035567,"当采用交流操作的保护装置时，变压器的瓦斯保护和中性点非直接接地电力网的接 地保护，可由（ ）取得操作电源，亦可增加电容储能电源作为跳闸的后备电源。 A.电压互感器； B变电所所用变压器； C硅整流; D.电池装置。",[460,461,462,463],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},"AB",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":24,"analysis":34},1035575,"已知某电厂1lOV直流系统蓄电池仅带控制负荷，经常电流为25A，放电初期（0~ Imin)放电电流为93A, 1~30min放电电流为25A, 30~60min放电电流为25A,选用GF 型铅酸蓄电池，电池个数为53个，根据已知条件回答下列问题。",[469,470,471,472],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":28,"analysis":34},1035577,"已知某电厂1lOV直流系统蓄电池仅带控制负荷，经常电流为25 A，放电初期（0~ Imin)放电电流为93A, 1~30min放电电流为25A, 30~60min放电电流为25A,选用GF 型铅酸蓄电池，电池个数为53个，根据已知条件回答下列问题。",[477,479,481,483],{"key":20,"text":478,"correct":22},"事故放电末期，放电系数为（)。",{"key":24,"text":480,"correct":22},"0.1; B0. 12；",{"key":28,"text":482,"correct":26},"0.14;",{"key":31,"text":484,"correct":22},"0.16。",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":73,"analysis":34},1035579,"已知某电厂1lOV直流系统蓄电池仅带控制负荷，经常电流为25 A，放电初期（0~ Imin)放电电流为93A, 1~30min放电电流为25A, 30~60min放电电流为25A,选用GF 型铅酸蓄电池，电池个数为53个，根据已知条件回答下列问题。 事故放电初期，冲击系数为（ ）。 A. 0.5; B 0.51; C. 0.52; D. 0.53。",[489,491,493,495],{"key":20,"text":490,"correct":22},"事故放电初期，单个电池电压为1.88V，则实际电压为额定电压的百分值为（ ）.",{"key":24,"text":492,"correct":26},"90%, B 90. 3%；",{"key":28,"text":494,"correct":26},"90.6%;",{"key":31,"text":496,"correct":22},"90.9%。",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":24,"analysis":34},1035582,"已知同第1题。",[501,502,503,504],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":507,"answer":28,"analysis":34},1035585,[508,509,510,511],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":514,"answer":28,"analysis":34},1035587,[515,516,517,518],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":24,"analysis":34},1035589,"已知同第1题。 最终选择的蓄电池额定容量为（ ）。",[523,525,527,529],{"key":20,"text":524,"correct":22},"180Ah；",{"key":24,"text":526,"correct":26},"200Ah;",{"key":28,"text":528,"correct":22},"250Ah；",{"key":31,"text":530,"correct":22},"300Ah。",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":533,"answer":28,"analysis":34},1035592,[534,535,536,537],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":540,"answer":24,"analysis":34},1035594,[541,543,545,547],{"key":20,"text":542,"correct":22},"基本模块数量为（ ）块。",{"key":24,"text":544,"correct":26},"1；",{"key":28,"text":546,"correct":22},"2; C 3；",{"key":31,"text":548,"correct":22},"4。",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":551,"answer":20,"analysis":34},1035597,[552,554,555,557],{"key":20,"text":553,"correct":26},"附加模块数量为（）块，",{"key":24,"text":544,"correct":22},{"key":28,"text":556,"correct":22},"2； C 3；",{"key":31,"text":548,"correct":22},{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":560,"answer":28,"analysis":34},1035599,[561,563,565,567],{"key":20,"text":562,"correct":22},"1组高频开关电源的模块数量为（）块。",{"key":24,"text":564,"correct":22},"1;",{"key":28,"text":566,"correct":26},"2, C 3；",{"key":31,"text":568,"correct":22},"4。 按方式2计算每组蓄电池配置2组高频开关电源其每组模块选择：",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":20,"analysis":34},1035602,"模块数量为（ ）块,",[573,574,576,578],{"key":20,"text":544,"correct":26},{"key":24,"text":575,"correct":22},"2；",{"key":28,"text":577,"correct":22},"3；",{"key":31,"text":548,"correct":22},[580,584,587,590,593,596],{"id":581,"name":582,"category":7,"favorite":583},1,"领导干部任职前廉政法规知识测试题",92,{"id":585,"name":586,"category":7,"favorite":581},595,"建筑结构与设备",{"id":588,"name":589,"category":7,"favorite":581},715,"招标采购专业知识与法律法规",{"id":591,"name":592,"category":7,"favorite":581},848,"市政方向-通用基础",{"id":594,"name":595,"category":7,"favorite":8},534,"BIM工程师",{"id":597,"name":595,"category":7,"favorite":8},535]