[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":543},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,4,50,2321,[13,30,38,46,54,62,70,78,86,94,102,114,122,134,142,154,162,174,186,194,206,214,226,238,250,262,274,286,298,306,318,330,342,354,366,378,390,402,414,423,435,447,459,471,482,492,500,512,523,531],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":29},1030846,1,"单选题","I类汽车库用电应为（ ) a. 一级负荷；B 二级负荷； c.三级负荷； d. 一级负荷中特别重要负荷。",[19,22,25,27],{"key":20,"text":20,"correct":21},"A",true,{"key":23,"text":23,"correct":24},"B",false,{"key":26,"text":26,"correct":24},"C",{"key":28,"text":28,"correct":24},"D","",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":32,"options":33,"answer":23,"analysis":29},1030850,"I类修车库用电应为（ ）。 A. 一级负荷； B 二级负荷； c三级负荷； d. —级负荷中特别重要负荷。",[34,35,36,37],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":20,"analysis":29},1030854,"建筑高度超过50m的乙、丙类厂房和丙类仓库，其消防用电设备应为（ ） a. 一级负荷； b. 二级负荷； C.三级负荷； d. —级负荷中特别重要负荷。",[42,43,44,45],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":23,"analysis":29},1030858,"座位数超过1500个的影剧院、座位数超过3000个的体育馆、任一层建筑面积大于 3000mz的商店、展览建筑，其消防用电设备应为（) a. 一级负荷； b. 二级负荷；C三级负荷； d. —级负荷中特别重要负荷。",[50,51,52,53],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":20,"analysis":29},1030861,"一类高层建筑的消防用电设备应为（ ）. a. 一级负荷； b. 二级负荷；c.三级负荷； d. —级负荷中特别重要负荷。",[58,59,60,61],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":63,"libraryId":5,"type":15,"typeLabel":16,"stem":64,"options":65,"answer":23,"analysis":29},1030863,"二类高层建筑的消防用电设备应为（ ) a. 一级负荷； b. 二级负荷；c.三级负荷； d. —级负荷中特别重要负荷。",[66,67,68,69],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":23,"analysis":29},1030867,"室外消防用水量大于25L\u002Fs的公共建筑，其消防用电设备应为（ ）。 a. 一级负荷； B二级负荷； c.三级负荷； d. —级负荷中特别重要负荷。",[74,75,76,77],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":23,"analysis":29},1030871,"室外消防用水量大于30L\u002FS的工厂、仓库，其消防用电设备应为（ ）。 A. 一级负荷；B二级负荷； c.三级负荷； d. —级负荷中特别重要负荷。",[82,83,84,85],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":23,"analysis":29},1030875,"室外消防用水量大于35L\u002Fs的可燃材料堆场、可燃气体储罐和甲、乙类液体储罐, 其消防用电设备应为（）。 a. 一级负荷；B. 二级负荷； c.三级负荷 d. 一级负荷中特别重要负荷。",[90,91,92,93],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":26,"analysis":29},1030879,"对一级负荷供电电源的要求是（ ）。 a.必须两回6kv及以上的线路供电； B应由两回6kv及以上的专別线路供电； c.应由两个电源供电，当一个电源发生故障时，另一个电源应不致同时受到损坏; d.除由两个电源供电外，尚应增设应急电源。",[98,99,100,101],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":23,"analysis":29},1030882,"对一级负荷中特别重要负荷供电电源的要求是（）。",[106,108,110,112],{"key":20,"text":107,"correct":24},"a.必须由两个电源供电；",{"key":23,"text":109,"correct":21},"b.除由两个电源供电外，尚应增设应急电源，并严禁将其他负荷接入应急电源系统；",{"key":26,"text":111,"correct":24},"c.应由两个电源供电，当一个电源发生故障时，另一个电源应不致同时受到损坏；",{"key":28,"text":113,"correct":24},"d.可由一个电源供电，但应増设应急电源。",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":20,"analysis":29},1030886,"对三级负荷供电电源的要求是（ ）。 a.无特殊要求； b.可由一回6kv及以上的架空线供电； C宜由两回线路供电； d.宜由两个电源供电。",[118,119,120,121],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":23,"analysis":29},1030890,"对二级负荷供电电源的要求是（）。",[126,128,130,132],{"key":20,"text":127,"correct":24},"a.宜由两个电源供电；",{"key":23,"text":129,"correct":21},"b.应由两回线路供电；",{"key":26,"text":131,"correct":24},"c.在负荷较小或地区供电条件困难时，可由一根6kv及以上的专用电缆线路供电；",{"key":28,"text":133,"correct":24},"d.无特殊要求。",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":28,"analysis":29},1030893,"在负荷较小或地区供电条件困难时，二级负荷可由一回6kV及以上的专用架空线 供电；当采用电缆线路时，应采用两根电缆组成的线路供电，其每根电缆应能承受（ ）的 二级负荷。 a. 50%; B.60%~70%; c. 80%； d. 100%,",[138,139,140,141],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":29},1030896,"允许中断供电时间为毫秒级的供电，其应急电源可选用（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":21},"a.蓄电池静止型不间断供电装置；",{"key":23,"text":149,"correct":24},"b.快速自起动的柴油发电机组；",{"key":26,"text":151,"correct":24},"c.带自动投入装置的独立于正常电源的专用馈电线路；",{"key":28,"text":153,"correct":24},"d.带自动重合闸装置的独立于正常电源的专用架空线路。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":29},1030900,"允许中断供电时间为（）以上的供电，其应急电源可选用快速自起动的柴油发电 机组。 a.毫秒级； b.1.5s; c. 5s; d. 15s",[158,159,160,161],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":28,"analysis":29},1030903,"当采用快速自启动的发电机组作为应急电源时，由它供电的一级负荷中特别重要负 荷允许的供电中断时间应不短于（ ）。",[166,168,170,172],{"key":20,"text":167,"correct":24},"1. 5ms;",{"key":23,"text":169,"correct":24},"15ms；",{"key":26,"text":171,"correct":24},"1. 5s；",{"key":28,"text":173,"correct":21},"15s",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":28,"analysis":29},1030907,"当一级负荷中特别重要负荷允许中断供电的时间为毫秒级时，可采用的应急电源是 ( ).",[178,180,182,184],{"key":20,"text":179,"correct":24},"快速自启动的发电机组；",{"key":23,"text":181,"correct":24},"带自动投入装置的、独立于正常电源的专用馈电线；",{"key":26,"text":183,"correct":24},"手动切换的独立于正常电源的专用馈电线路；",{"key":28,"text":185,"correct":21},"蓄电池静止型不间断供电装置、蓄电机械贮能电机型供电装置或柴油机不间断供电 装置。",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":26,"analysis":29},1030911,"将其他负荷（除一级负荷中特别重要负荷之外的负荷）接入由应急电源供电的应急 供电系统，是设计规范所（ ）. A.推荐的； B允许的； C.严禁的； D.不宜的。",[190,191,192,193],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":28,"analysis":29},1030915,"对一级负荷中特别重要负荷供电的应急电源，它与正常电源的关系是（ ）。",[198,200,202,204],{"key":20,"text":199,"correct":24},"应并列运行；",{"key":23,"text":201,"correct":24},"宜并列运行；",{"key":26,"text":203,"correct":24},"可并列运行；",{"key":28,"text":205,"correct":21},"必须采取措施防止并列运行。",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":26,"analysis":29},1030919,"同时供电的两回及以上供配电线路中一回路中断供电时，其余线路应能供给（ ）。 A. 一级负荷中的特别重要负荷； B全部一级负荷； C.全部一、二级负荷之和； D.全部一、二、三级负荷之和。",[210,211,212,213],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":29},1030922,"设计供配电系统的正确原则之一是（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":21},"除一级负荷中特别重要负荷外，不应按一个电源系统检修或故障的同时另一电源又 发生故障进行设计；",{"key":23,"text":221,"correct":24},"无论负荷级别如何，都应按一个电源系统检修或故障的同时另一电源又发生故障进 行设计；",{"key":26,"text":223,"correct":24},"除一级负荷中特别重要负荷外，应按一个电源系统检修或故障的同时另一电源又发 生故障进行设计；",{"key":28,"text":225,"correct":24},"无论负荷级别如何，都不应按一个电源系统检修或故障的同时另一电源又发生故障 进行设计。",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":29},1030926,"为使供电系统简单可靠，同一电压供电系统的配电级数不宜多于（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":21},"两级；",{"key":23,"text":233,"correct":24},"三级；",{"key":26,"text":235,"correct":24},"五级；",{"key":28,"text":237,"correct":24},"四级。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":28,"analysis":29},1030929,"有一级负荷的用电单位难以从地区电力网取得两个电源时，从邻近单位取得第二电 源的正确原则是（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":24},"只要有可能从邻近单位取得第二电源，无论其供电可靠性如何，都应从邻近单位取 得第二电源；",{"key":23,"text":245,"correct":24},"B—律禁止从邻近单位取得第二电源，必须自备发电机；",{"key":26,"text":247,"correct":24},"有可能从邻近单位取得第二电源，且第二电源满足“当第一电源发生故障时，第二 电源不应同时受到损坏”的条件，就必须从邻近单位取得第二电源；",{"key":28,"text":249,"correct":21},"有可能从邻近单位取得第二电源，且第二电源满足“当第一电源发生故障时，第二 电源不应同时受到损坏”的条件，宜从邻近单位取得第二电源。",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":23,"analysis":29},1030933,"当配电电压为35kV时，（ ）。",[254,256,258,260],{"key":20,"text":255,"correct":24},"不准采用35kV直降380\u002F220V配电；",{"key":23,"text":257,"correct":21},"可以采用35kV直降380\u002F220V配电；",{"key":26,"text":259,"correct":24},"必须将35kV降为10k_V再降为380\u002F220V配电；",{"key":28,"text":261,"correct":24},"必须将35kV降为6kV再降为380\u002F220V配电。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":23,"analysis":29},1030937,"供配电系统设计的正确原则之一是（）。",[266,268,270,272],{"key":20,"text":267,"correct":24},"变配电所应远离负荷中心；",{"key":23,"text":269,"correct":21},"变配电所宜靠近负荷中心；",{"key":26,"text":271,"correct":24},"只有10kV及以下变配电所才宜靠近负荷中心；",{"key":28,"text":273,"correct":24},"lOkV及以上变配电所，尽管条件允许，也不应靠近负荷中心。",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":20,"analysis":29},1030941,"用电单位内部、邻近的变电所之间，设置联络线的正确原则是（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":21},"宜设置低压联络线；",{"key":23,"text":281,"correct":24},"禁止设置低压联络线；",{"key":26,"text":283,"correct":24},"必须设置低压联络线；",{"key":28,"text":285,"correct":24},"不宜设置低压联络线。",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":20,"analysis":29},1030944,"确定小负荷用电单位供电电源方案的正确原则是.（）。",[290,292,294,296],{"key":20,"text":291,"correct":21},"宜接入地区低压电网；",{"key":23,"text":293,"correct":24},"宜自建变电所；",{"key":26,"text":295,"correct":24},"宜自建发电厂；",{"key":28,"text":297,"correct":24},"宜装设柴油发电机组。",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":26,"analysis":29},1030947,"低压配电系统设计中，当部分用电设备距供电点较远，且彼此距离很近、容量很 小、性质次要，则可采用链式供电，但每一链式回路上的设备不宜超过（）台，其总容 量不宜超过（ ）。 A. 10、20kW； B 7、15kW； C 5、10kW; D. 3、8kW。",[302,303,304,305],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":26,"analysis":29},1030951,"低压配电系统中，确定同一生产流水线的各用电设备的配电方式的原则是（）。",[310,312,314,316],{"key":20,"text":311,"correct":24},"应由不同回路配电；",{"key":23,"text":313,"correct":24},"禁由不同回路配电,",{"key":26,"text":315,"correct":21},"宜由同一回路配电；",{"key":28,"text":317,"correct":24},"宜由不同回路配电。",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":23,"analysis":29},1030962,"在TN及TT系统接地型式的低压电网中，三相配电变压器的接线组别宜选 用（）。",[322,324,326,328],{"key":20,"text":323,"correct":24},"YynO；",{"key":23,"text":325,"correct":21},"Dynll；",{"key":26,"text":327,"correct":24},"Ydll；",{"key":28,"text":329,"correct":24},"YNdll.",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":26,"analysis":29},1030966,"在TN及TT系统接地型式的低压电网中，当选用YynO接线组别的三相变压器时, 其由单相不平衡负荷引起的中性线电流不得超过低压绕组额定电流的（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":24},"50%;",{"key":23,"text":337,"correct":24},"40%；",{"key":26,"text":339,"correct":21},"25%；",{"key":28,"text":341,"correct":24},"10%。",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":26,"analysis":29},1030969,"在TN及TT系统接地型式的低压电网中，当选用YynO接线组别的三相变压器时， 除控制中性电流不超过低压线组额定电流的25%外，还应控制任一相电流不超过低压绕组 额定电流的（ ）。",[346,348,350,352],{"key":20,"text":347,"correct":24},"75%-,",{"key":23,"text":349,"correct":24},"87.5%;",{"key":26,"text":351,"correct":21},"100%；",{"key":28,"text":353,"correct":24},"125%。",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":20,"analysis":29},1030972,"当采用220\u002F380V的TN及TT系统接地型式的低压电网时，照明和其他电力设备 的供电关系是（）。",[358,360,362,364],{"key":20,"text":359,"correct":21},"宜由同一台变压器供电，必要时亦可单独设置照明变压器；",{"key":23,"text":361,"correct":24},"禁止由同一台变压器供电；",{"key":26,"text":363,"correct":24},"经主管部门批准，可由同一台变压器供电；",{"key":28,"text":365,"correct":24},"必须由同一台变压器供电，不应单独设置照明变压器。",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":20,"analysis":29},1030975,"由建筑物外引人的配电线路，在室内靠近进线点处，是否需要装设隔离电器的条件 是（ ）。",[370,372,374,376],{"key":20,"text":371,"correct":21},"无条件，都应装设；",{"key":23,"text":373,"correct":24},"放射式供电，可不装设；",{"key":26,"text":375,"correct":24},"树干式供电，可不装设；",{"key":28,"text":377,"correct":24},"该建筑物与供电电源归同一单位管理维护时，可不装设",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":28,"analysis":29},1030979,"我国110kV电网，除个别特殊地区外，中性点接地方式一般多采用（ )",[382,384,386,388],{"key":20,"text":383,"correct":24},"不接地；",{"key":23,"text":385,"correct":24},"经消弧线圈接地；",{"key":26,"text":387,"correct":24},"经电阻接地；",{"key":28,"text":389,"correct":21},"直接接地。",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":28,"analysis":29},1030983,"中心点不接地的电网单相接地故障时，电网带故障继续运行的允许时间是（ ）。",[394,396,398,400],{"key":20,"text":395,"correct":24},"2s;",{"key":23,"text":397,"correct":24},"2min；",{"key":26,"text":399,"correct":24},"20min；",{"key":28,"text":401,"correct":21},"1~2h。",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":23,"analysis":29},1030987,"按限制操作过电压和弧光接地过电压的效果，最好的排在最前，顺次递减，多种中 性点接地方式的正确顺序是（）。",[406,408,410,412],{"key":20,"text":407,"correct":24},"不接地，经消弧线圈接地，经低电阻接地，直接接地；",{"key":23,"text":409,"correct":21},"直接接地，经低电阻接地，经消孤线圏接地，不接地；",{"key":26,"text":411,"correct":24},"经低电阻接地，经消孤线圏接地，不接地，直接接地；",{"key":28,"text":413,"correct":24},"经消弧线團接地，经低电阻接地，不接地，直接接地。",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":28,"analysis":29},1030990,"如果仅以限制操作过电压和弧光接地过电压为目的，应选择的中性点接地方式是（）",[418,419,420,422],{"key":20,"text":383,"correct":24},{"key":23,"text":385,"correct":24},{"key":26,"text":421,"correct":24},"经低电阻接地；",{"key":28,"text":389,"correct":21},{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":28,"analysis":29},1030994,"中性点经消弧线圏接地的最好运行方式是（ 〉。",[427,429,431,433],{"key":20,"text":428,"correct":24},"全补偿；",{"key":23,"text":430,"correct":24},"欠补偿；",{"key":26,"text":432,"correct":24},"过补偿，手动控制过朴偿量为适当值；",{"key":28,"text":434,"correct":21},"过补偿，自动控制过补偿量为适当值。",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":23,"analysis":29},1030998,"正常运行情况下，电动机、一般工作场所的照明和无特殊规定的用电设备端子处电 压偏差允许值（以额定电压的百分数表示）为( )。",[439,441,443,445],{"key":20,"text":440,"correct":24},"±10% ；",{"key":23,"text":442,"correct":21},"±5%；",{"key":26,"text":444,"correct":24},"士7%’",{"key":28,"text":446,"correct":24},"正负偏差绝对值之和不超过10%。",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":26,"analysis":29},1031002,"对远离变电所的小面积一般工作场所的照明、应急照明、道路照明和警卫照明，在 正常情况下，用电设备端子处的电压偏差（以额定电压百分数表示）可为（ )。",[451,453,455,457],{"key":20,"text":452,"correct":24},"±10%;",{"key":23,"text":454,"correct":24},"±7%;",{"key":26,"text":456,"correct":21},"+5, -10%；",{"key":28,"text":458,"correct":24},"+10，一5%。",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":23,"analysis":29},1031005,"10kV及以下三相供电的电压允许偏差，在用户电能计量点处考核，为（ ）。",[463,465,467,469],{"key":20,"text":464,"correct":24},"标称电压的±10%;",{"key":23,"text":466,"correct":21},"B标称电压的±7%;",{"key":26,"text":468,"correct":24},"标称电压的士5%;",{"key":28,"text":470,"correct":24},"正、负偏差绝对值之和不超过标称电压的10%。",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":28,"analysis":29},1031008,"35kV及以上供电电压允许偏差，在用户电能计量点处考核，为（ ）.",[475,477,479,480],{"key":20,"text":476,"correct":24},"标称电压的土 10%;",{"key":23,"text":478,"correct":24},"标称电压的士7%;",{"key":26,"text":468,"correct":24},{"key":28,"text":481,"correct":21},"正、负偏差絶对值之和不超过标称电压的10%。",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":28,"analysis":29},1031009,"220V单相供电电压允许偏差，在用户电能计量点处考核，为（）。",[486,487,488,490],{"key":20,"text":464,"correct":24},{"key":23,"text":478,"correct":24},{"key":26,"text":489,"correct":24},"标称电压的±5%;",{"key":28,"text":491,"correct":21},"标称电压的+7%、10%。",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":23,"analysis":29},1031012,"为降低220\u002F380V三相四线低压配电系统的不对称度，由地区公共低压电网供电的 220V照明负荷，当电流大于30A时，宜采用的供电方式是（ ）。 A. 220V单相供电, R 220\u002F380V三相四线制供电； C. 220\u002F380V两相三线制供电； D. 380V供电再变220V。",[496,497,498,499],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":20,"analysis":29},1031015,"供配电系统中的逆调压是指（ ）。",[504,506,508,510],{"key":20,"text":505,"correct":21},"负荷增加，送端电压往高调，负荷减小，送端电压往低调；",{"key":23,"text":507,"correct":24},"负荷增加，送端电压往低调，负荷减小，送端电压往高调；",{"key":26,"text":509,"correct":24},"无论负荷增加或减小，都维持送端电压不变；",{"key":28,"text":511,"correct":24},"无论负荷增加或减小，都不进行调节，送端电压任其自然变化。",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":28,"analysis":29},1031018,"35kV以上电网逆调压的范围宜为额定电压的（ ）。",[516,517,519,521],{"key":20,"text":454,"correct":24},{"key":23,"text":518,"correct":24},"士5%;",{"key":26,"text":520,"correct":24},"0~+7%；",{"key":28,"text":522,"correct":21},"0~+5%。",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":28,"analysis":29},1031021,"供电电压偏差允许值的时间条件是（ ）。 A. —天中的最大偏差值； B*—月中的最大偏差值； C. 一季度中的最大偏差值； D. —年四个季度中的最大偏差值。",[527,528,529,530],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":28,"analysis":29},1031024,"供电电压偏差允许值的考核处所是（）。",[535,537,539,541],{"key":20,"text":536,"correct":24},"用户接地的地区变电所母线；",{"key":23,"text":538,"correct":24},"用户降压变电所主变压器低压侧母线；",{"key":26,"text":540,"correct":24},"用户用电设备端子处；",{"key":28,"text":542,"correct":21},"用户计费电度表处。",[544,547,550,553,556,559],{"id":15,"name":545,"category":7,"favorite":546},"领导干部任职前廉政法规知识测试题",92,{"id":548,"name":549,"category":7,"favorite":15},595,"建筑结构与设备",{"id":551,"name":552,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":554,"name":555,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":557,"name":558,"category":7,"favorite":8},534,"BIM工程师",{"id":560,"name":558,"category":7,"favorite":8},535]