[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-39":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":624},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,39,50,2321,[13,34,48,60,72,84,97,109,121,134,147,160,168,180,192,204,217,229,242,255,267,279,291,303,315,326,339,351,363,375,387,399,411,423,435,447,459,471,483,495,506,517,529,540,552,564,576,589,600,612],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":32,"analysis":33},1035342,2,"多选题","架空线路导线排列方式为（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","35kV架空线路的导线一般采用三角形或水平排列；",true,{"key":24,"text":25,"correct":22},"B","10kV架空线路的导线一般采用三角形或水平排列；",{"key":27,"text":28,"correct":22},"C","10kV多回架空线路导线，宜采用三角形、水平混合排列或垂直排列；",{"key":30,"text":31,"correct":22},"D","lkV以下架空线路导线，一般采用水平排列。","ABCD","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":47,"analysis":33},1035345,"架空线路导线间隔应为（)。",[38,41,43,45],{"key":20,"text":39,"correct":40},"10kV及以下线路与35kV线路同杆架设时，导线间垂直距离不应小于3m;",false,{"key":24,"text":42,"correct":40},"10kV双回路或多回路的直线杆横担垂直距离不应小于lm;",{"key":27,"text":44,"correct":22},"通信电缆与10kV架空线路合杆时，其间距不应小于2.5m;",{"key":30,"text":46,"correct":22},"广播线路及通信电缆与380V架空线路合杆时，其间距不应小于1.5m。","CD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":47,"analysis":33},1035348,"10kV及以下架空线路绝缘子类型应按（ ）选择。",[52,54,56,58],{"key":20,"text":53,"correct":40},"蝴蝶形絶缘子多用于10kV及以下的转角杆；",{"key":24,"text":55,"correct":40},"针式绝缘子多用于线路终端、耐张及转角杆上；",{"key":27,"text":57,"correct":22},"悬式绝缘子用于6kV及以上的线路上；",{"key":30,"text":59,"correct":22},"拉紧绝缘子用于拉线上作为拉线绝缘和连接用。",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":32,"analysis":33},1035351,"按绝缘水平选择绝缘子应符合（ ）要求。",[64,66,68,70],{"key":20,"text":65,"correct":22},"一般地区架空线路其绝缘子或绝缘子串的爬电比距（桉额定线电压计算值）不应小 于 1.6cm\u002FkV;",{"key":24,"text":67,"correct":22},"架设在污秽地区的线路应根据运行经验和可能污染的程度，增加爬电比距；",{"key":27,"text":69,"correct":22},"污秽地区的线路宜采用防污型絶缘子或采取其他有效措施；",{"key":30,"text":71,"correct":22},"3~10kV钢筋混凝土电杆铁横担、对供电可靠性要求高的线路，宜采用高一级电压 等级的绝缘子。",{"id":73,"libraryId":5,"type":15,"typeLabel":16,"stem":74,"options":75,"answer":32,"analysis":33},1035353,"不同污秽等级下的爬电比距应符合（ ）要求。",[76,78,80,82],{"key":20,"text":77,"correct":22},"污秽等级I——大气轻度污秽地区：1. 6~2. Ocm\u002FkV;",{"key":24,"text":79,"correct":22},"污秽等级Ⅱ——大气中等污秽地区：2. 0~2. 5cm\u002FkV;",{"key":27,"text":81,"correct":22},"污秽等级Ⅲ——大气污染较严重地区：2. 5~3. 2cm\u002FkV;",{"key":30,"text":83,"correct":22},"污秽等级Ⅳ——大气特别严重汚染地区：3. 2~3. 8cm\u002FkV。",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":96,"analysis":33},1035356,"断路器的控制回路应满足的要求有（ ）。",[88,90,92,94],{"key":20,"text":89,"correct":22},"应能指示合闸和跳闸的位置；",{"key":24,"text":91,"correct":22},"能监视电源及跳、合闸回路的完整性；",{"key":27,"text":93,"correct":22},"C有防止断路器“跳跃”的电气闭锁装置；",{"key":30,"text":95,"correct":40},"合闸或跳闸完成后应由另外的装置使命令脉冲解除。","ABC",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":96,"analysis":33},1035358,"在主控制室内控制的断路器当采用音响监视控制回路时，一般为单灯接线，应满足 的要求有（ ）.",[101,103,105,107],{"key":20,"text":102,"correct":22},"断路器的控制回路用中间继电器监视；",{"key":24,"text":104,"correct":22},"断路器的位置由控制开关的手柄位置来表示；",{"key":27,"text":106,"correct":22},"控制开关手柄内应有信号灯；",{"key":30,"text":108,"correct":40},"信号灯在断路器与控制开关位置对应时燃亮。",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":96,"analysis":33},1035361,"下列电力装置回路，应测量无功功率的有（ ）。",[113,115,117,119],{"key":20,"text":114,"correct":22},"髙压侧35kV及以上，低压侧1200V及以上的主变压器，其中双绕组主变压器只测 量一侧，三绕组主变压器测量两侧；",{"key":24,"text":116,"correct":22},"1200V及以上的并联电力电容器组；",{"key":27,"text":118,"correct":22},"35kV以上的线路；",{"key":30,"text":120,"correct":40},"35kV以上的永久性内桥断路器回路。",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":133,"analysis":33},1035364,"下列电力装置回路，应采用三只电流表分别测量三相电流的有（）。",[125,127,129,131],{"key":20,"text":126,"correct":22},"三相负荷不平衡率大于15%的1200V以下供电线路；",{"key":24,"text":128,"correct":22},"三相负荷不平衡率大于10%的1200V及以上供电线路；",{"key":27,"text":130,"correct":40},"1lOkV所有线路；",{"key":30,"text":132,"correct":22},"并联电力电容器组的总回路。","ABD",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":146,"analysis":33},1035367,"电流互感器的应用，应遵守的规则是( )。",[138,140,142,144],{"key":20,"text":139,"correct":22},"测量仪表与保护装置共用一组电流互感器时，宜分别接于不同的二次绕组；",{"key":24,"text":141,"correct":40},"若受条件限制测量仪表与保护装置需共用一个二次绕组时，应该将保护接在仪表 之后；",{"key":27,"text":143,"correct":22},"电流互感器的二次回路一般不进行切换；",{"key":30,"text":145,"correct":22},"应有一个接地点，宜在配电装置处接地。","ACD",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":159,"analysis":33},1035369,"变配电所的中央信号装置由下列信号（ ）组成。",[151,153,155,157],{"key":20,"text":152,"correct":22},"事故信号；",{"key":24,"text":154,"correct":40},"瞬时预告信号；",{"key":27,"text":156,"correct":40},"延时预告信号；",{"key":30,"text":158,"correct":22},"带短延时的瞬时预告信号。","AD",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":96,"analysis":33},1035372,"6~35kV线路应安装的保护有（ ）。 A.无时限或带时限的电流速断保护； B.过电流保护； C根据需要装设单相接地保护； D.低电压保护。",[164,165,166,167],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":40},{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":146,"analysis":33},1035374,"对电力变压器，应装设相应的保护装置的情况有（ ）。",[172,174,176,178],{"key":20,"text":173,"correct":22},"绕组的匝间短路；",{"key":24,"text":175,"correct":40},"电压降低；",{"key":27,"text":177,"correct":22},"冷却系统故障；",{"key":30,"text":179,"correct":22},"变压器温度升髙。",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":96,"analysis":33},1035377,"变压器的纵联差动保护应符合的规定有（ ）。",[184,186,188,190],{"key":20,"text":185,"correct":22},"应能躲过励磁涌流；",{"key":24,"text":187,"correct":22},"应能躲过外部短路产生的不平衡电流；",{"key":27,"text":189,"correct":22},"差动保护范围应包括变压器套管及其引线；",{"key":30,"text":191,"correct":40},"差动保护范围可以包括变压器套管而不包括其引线。",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":96,"analysis":33},1035380,"对电压为3kV及以上的异步电动机应装设保护防御的故障有（ ）。",[196,198,200,202],{"key":20,"text":197,"correct":22},"定子绕组相间短路；",{"key":24,"text":199,"correct":22},"定子绕组过负荷；",{"key":27,"text":201,"correct":22},"定子绕组单相接地；",{"key":30,"text":203,"correct":40},"定子绕组过电压。",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":216,"analysis":33},1035383,"变配电所计箅机监控系统的选型应做到安全可靠、（ ）、（ ）、符合国情。",[208,210,212,214],{"key":20,"text":209,"correct":40},"方便灵活；",{"key":24,"text":211,"correct":22},"技术先进；",{"key":27,"text":213,"correct":40},"节省投资；",{"key":30,"text":215,"correct":22},"经济适用。","BD",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":133,"analysis":33},1035385,"1600kVA油浸变压器单独运行且不作为其他电源的备用时保护配置为（ ).",[221,223,225,227],{"key":20,"text":222,"correct":22},"带时限的过电流保护；",{"key":24,"text":224,"correct":22},"电流速断保护；",{"key":27,"text":226,"correct":40},"过负荷保护；",{"key":30,"text":228,"correct":22},"瓦斯保护和温度保护。",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":241,"analysis":33},1035387,"断路器采用灯光监视回路时，宜采用双灯制接线，以下关于灯光指示的选项正确的 是（ ）。",[233,235,237,239],{"key":20,"text":234,"correct":22},"断路器在合闸位置时，红灯亮；",{"key":24,"text":236,"correct":22},"断路器在跳闸位置时，缘灯亮；",{"key":27,"text":238,"correct":40},"断路器在合闸位置时，绿灯亮；",{"key":30,"text":240,"correct":40},"断路器在跳闸位置时，红灯与绿灯都亮。","AB",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":254,"analysis":33},1035390,"常用测量仪表的准确度等级，应按（ ）要求选择。",[246,248,250,252],{"key":20,"text":247,"correct":40},"交流回路仪表的准确度等级，不应低于2. 5级；",{"key":24,"text":249,"correct":22},"除谐波测量仪表外，交流回路仪表的准确庋等级不应低于1.5级；",{"key":27,"text":251,"correct":22},"直流回路仪表的准确度等级，不应低于1.5级；",{"key":30,"text":253,"correct":22},"电量变送器输出侧仪表的准确度，不应低于1.0级。","BCD",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":96,"analysis":33},1035393,"常用测量仪表配用的互感器准确度等级，应按（ ）要求选择。",[259,261,263,265],{"key":20,"text":260,"correct":22},"准确度等级1.5级的常用測量仪表，应配用不低于1.0级的互感器；",{"key":24,"text":262,"correct":22},"电量变送器应配用不低于0.5级的电流互感器；",{"key":27,"text":264,"correct":22},"准确度等级2. 5级的常用测量仪表，应配用不低于1.0级的互感器；",{"key":30,"text":266,"correct":40},"电量变送器应配用不低于1.0级的电流互感器。",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":96,"analysis":33},1035396,"( )电力装置回路，应测量交流电压。",[271,273,275,277],{"key":20,"text":272,"correct":22},"发电机；",{"key":24,"text":274,"correct":22},"交流系统的各段母线；",{"key":27,"text":276,"correct":22},"根据生产工艺的要求，需监测交流电压的其他电力装置回路；",{"key":30,"text":278,"correct":40},"照明。",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":32,"analysis":33},1035398,"在（ )，应采用三只电流表分别测量三相电流。",[283,285,287,289],{"key":20,"text":284,"correct":22},"三相负荷不平衡率大于10%的1200V及以上的电力用户线路；",{"key":24,"text":286,"correct":22},"三相负荷不平衡率大于15%的1200V以下的供电线路；",{"key":27,"text":288,"correct":22},"并联电力电容器组的总回路》",{"key":30,"text":290,"correct":22},"汽轮发电机和380V的水轮发电机电力装置回路。",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":32,"analysis":33},1035401,"( )应测量有功功率。",[295,297,299,301],{"key":20,"text":296,"correct":22},"35kV及以上的线路；",{"key":24,"text":298,"correct":22},"发电机电力装置回路；",{"key":27,"text":300,"correct":22},"专用旁路和兼用旁路的断路器回路；",{"key":30,"text":302,"correct":22},"根据生产工艺的要求，需监测有功功率的其他电力装置回路。",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":32,"analysis":33},1035404,"( )应装设无功电能表。",[307,309,311,313],{"key":20,"text":308,"correct":22},"并联电力电容器组电力装置回路；",{"key":24,"text":310,"correct":22},"电力用户处的无功电量计量点电力装置回路；",{"key":27,"text":312,"correct":22},"电力系统中，3~IlOkV的线路；",{"key":30,"text":314,"correct":22},"发电机电力装置回路。",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":146,"analysis":33},1035406,"( )应采用2.0级的有功电能表.",[319,321,322,324],{"key":20,"text":320,"correct":22},"75kW及以上的电动机电力装里回路；",{"key":24,"text":298,"correct":40},{"key":27,"text":323,"correct":22},"在315kVA以下的变压器低压侧计费的电力用户电能计量点电力装置回路；",{"key":30,"text":325,"correct":22},"仅作为企业内部技术经济考核而不计费的线路和电力装置回路。",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":338,"analysis":33},1035409,"( )电力装置回路，应采用3.0级的无功电能表。",[330,332,334,336],{"key":20,"text":331,"correct":40},"发电机",{"key":24,"text":333,"correct":22},"在315kVA以下的变压器低压侧计费的电力用户能量计量点；",{"key":27,"text":335,"correct":22},"仅作为企业内部技术经济考核而不计费的电力用户电能计量点；",{"key":30,"text":337,"correct":40},"75kW及以上的电动机。","BC",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":32,"analysis":33},1035412,"( )应配用不低于0.5级的互感器。",[343,345,347,349],{"key":20,"text":344,"correct":22},"1.0级的有功电能表；",{"key":24,"text":346,"correct":22},"1.0级的专用电能计量仪表；",{"key":27,"text":348,"correct":22},"2. 0级计费用的有功电能表；",{"key":30,"text":350,"correct":22},"2.0级的无功电能表。",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":146,"analysis":33},1035414,"3~1lOkV电力网中，在（ ）情况下，应装设自动重合闸装置。",[355,357,359,361],{"key":20,"text":356,"correct":22},"旁路断路器和兼作旁路的母联或分段断路器；",{"key":24,"text":358,"correct":40},"3kV及以上的电缆线路，当用电设备允许且无备用电源自动投入时；",{"key":27,"text":360,"correct":22},"3kV及以上的架空线路，当用电设备允许且无备用电源自动投入时；",{"key":30,"text":362,"correct":22},"3kV及以上的电缆与架空的混合线路，当用电设备允许且无备用电源自动投入时。",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":241,"analysis":33},1035417,"对单侧电源线路的自动重合闸方式的选择应符合（ ）规定。",[367,369,371,373],{"key":20,"text":368,"correct":22},"采用一次重合闸；",{"key":24,"text":370,"correct":22},"当电力网由几段串联线路构成时，宜采用重合闸前加速保护动作或顺序自动重合闸",{"key":27,"text":372,"correct":40},"采用解列重合闸；",{"key":30,"text":374,"correct":40},"同步检定的重合闸。",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":254,"analysis":33},1035420,"双侧电源的单回线路，（ )方式。",[379,381,383,385],{"key":20,"text":380,"correct":40},"可采用一次重合闸；",{"key":24,"text":382,"correct":22},"可采用解列重合闸；",{"key":27,"text":384,"correct":22},"当水力发电厂条件许可时，可釆用自同步重合闸；",{"key":30,"text":386,"correct":22},"可采用一侧无电压检定，另一侧同步检定的重合闸。",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":96,"analysis":33},1035422,"自动重合闸装置，应符合（ ）要求。",[391,393,395,397],{"key":20,"text":392,"correct":22},"手动或通过遥控装置将断路器断开或将断路器投入故障线路上而随即由保护装置将 其断开时，自动重合闸均不应动作;",{"key":24,"text":394,"correct":22},"自动重合闸装置在装置的某些元件损坏以及继电器触点粘住或拒动等情况下，均不 应使断路器多次重合；",{"key":27,"text":396,"correct":22},"当断路器处于不正常状态不允许实现自动重合闸时，应将自动重合闸装置闭锁;",{"key":30,"text":398,"correct":40},"可釆用一侧无电压检定，另一侧同步检定的重合闸。",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":32,"analysis":33},1035425,"( )情况可装设备用电源或备用设备的自动投入装置。",[403,405,407,409],{"key":20,"text":404,"correct":22},"由双申源供电的变电站和配电所，其中一个电源经常断开作为备用；",{"key":24,"text":406,"correct":22},"发电厂、变电站和配电所内有互为备用的母线段；",{"key":27,"text":408,"correct":22},"发电厂、变电站内有备用变压器；",{"key":30,"text":410,"correct":22},"变电站内有两台站用变压器.",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":32,"analysis":33},1035428,"备用设备的自动投入装置，应符合（ ）要求。",[415,417,419,421],{"key":20,"text":416,"correct":22},"保证备用电源有电压、工作回路断开后才投入备用回路； 9",{"key":24,"text":418,"correct":22},"工作回路上的电压，不论因何原因消失时，自动投入装置均应延时动作；",{"key":27,"text":420,"correct":22},"手动断开工作回路时，不启动自动投入装置；",{"key":30,"text":422,"correct":22},"保证自动投入装置只动作一次。",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":32,"analysis":33},1035431,"变电所内的（ ）元件，应在控制室内控制。",[427,429,431,433],{"key":20,"text":428,"correct":22},"主变压器；",{"key":24,"text":430,"correct":22},"屋外配电装置的母线分段、旁路及母联断路器；",{"key":27,"text":432,"correct":22},"35kV屋外配电装置的线路；",{"key":30,"text":434,"correct":22},"1lOkV屋外配电装置的线路。",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":32,"analysis":33},1035434,"继电保护和自动装置应满足可靠性、选择性、灵敏性和速动性的要求，并应符合 ( )规定。",[439,441,443,445],{"key":20,"text":440,"correct":22},"继电保护和自动装置应简单可靠，使用的元件和触点应尽量少，接线回路简单，运 行维护方便，在能够满足要求的前提下宜采用最简单的保护；",{"key":24,"text":442,"correct":22},"对相邻设备和线路有配合要求的保护，前后两级之间的灵敏性和动作时间应相互 配合；",{"key":27,"text":444,"correct":22},"当被保护设备或线路范围内发生故障时，应具有必要的灵敏系数；",{"key":30,"text":446,"correct":22},"保护装置应能尽快地切除短路故障。当需要加速切除短路故障时，可允许保护装置 无选择性地动作，但应利用自动重合闸或备用电源自动投入装置，缩小停电范围。",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":96,"analysis":33},1035435,"0.4MVA及以上，绕组为星形一星形联结、低压侧中性点直接接地的变压器，对低 压侧单相接地短路应选择（）方式，保护装置应带时限动作于跳闸。",[451,453,455,457],{"key":20,"text":452,"correct":22},"利用高压侧的过电流保护时，保护装置宜采用三相式保护；",{"key":24,"text":454,"correct":22},"接于低压倒中性线上的零序电流保护；",{"key":27,"text":456,"correct":22},"接于低压侧的三相电流保护；",{"key":30,"text":458,"correct":40},"接于低压侧的两相电流保护。",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":32,"analysis":33},1035437,"对3kV及以上的并联补偿电容器组的（ 〉故障及异常运行方式，应装设相应的 保护装置。",[463,465,467,469],{"key":20,"text":464,"correct":22},"电容器内部故障及其引出线短路；",{"key":24,"text":466,"correct":22},"电容器組和断路器之间连接线短路；",{"key":27,"text":468,"correct":22},"电容器组中某些故障电容器切除后所引起的过电压；",{"key":30,"text":470,"correct":22},"电容器组的单相接地。",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":96,"analysis":33},1035439,"对3~35kV线路的（ ）故障或异常运行，应装设相应的保护装置。",[475,477,479,481],{"key":20,"text":476,"correct":22},"相间短路；",{"key":24,"text":478,"correct":22},"单相接地；",{"key":27,"text":480,"correct":22},"过负荷；",{"key":30,"text":482,"correct":40},"过电压。",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":32,"analysis":33},1035441,"对3?1OkV线路装设相间短路保护装置，应符合（ ）要求。 A.由电流继电器构成的保护装置，应接于两相电流互感器上，同一网络的所有线路均",[487,489,491,493],{"key":20,"text":488,"correct":22},"应装在相同的两相上；",{"key":24,"text":490,"correct":22},"当线路短路使发电厂厂用母线或重要用户母线电压低于额定电压的63%时，以及线 路导线截面过小，不允许带时限切除短路时，应快速切除故障；",{"key":27,"text":492,"correct":22},"当过电流保护的时限不大于0.5?0.7s时，且没有特殊情况时，或没有配合上的要 求时，可不装设瞬动的电流速断保护；",{"key":30,"text":494,"correct":22},"后备保护应采用远后备方式。",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":32,"analysis":33},1035443,"对电压为3kV及以上的异步电动机和同步电动机的（ ）故障及异常运行方式， 应装设相应的保护装置。",[499,501,502,504],{"key":20,"text":500,"correct":22},"同步电动机失磁；",{"key":24,"text":197,"correct":22},{"key":27,"text":503,"correct":22},"定子绕组低电压；",{"key":30,"text":505,"correct":22},"定子绕组单相接地。",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":32,"analysis":33},1035445,"对6~1lOkV油浸电力变压器的（ ）故障及异常运行方式，应装设相应的保护 装置。",[510,512,513,515],{"key":20,"text":511,"correct":22},"绕组及其引出线的相间短路和在中性点直接接地侧的单相接地短路；",{"key":24,"text":480,"correct":22},{"key":27,"text":514,"correct":22},"油面降低，变压器溫度升高或油箱压力升高或冷却系统故障；",{"key":30,"text":516,"correct":22},"绕组的匝间短路。",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":338,"analysis":33},1035446,"按机械强度要求，继电保护、自动装置、控制、信号的二次回路线路，铜芯控制电 缆或绝缘导线的芯线最小截面为（）。",[521,523,525,527],{"key":20,"text":522,"correct":40},"弱电回路：不应小于1.5mm2;",{"key":24,"text":524,"correct":22},"弱电回路：不应小于0.5mm2;",{"key":27,"text":526,"correct":22},"强电控制回路,不应小于1.5mm2;",{"key":30,"text":528,"correct":40},"强电控制回路：不应小于2.5mm2。",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":96,"analysis":33},1035448,"继电保护、自动装置、控制、信号的二次回路线路电缆芯线截面的选择尚应符合 ( )要求。",[533,535,537,539],{"key":20,"text":534,"correct":22},"电流回路：应使电流互感器的工作准确等级，符合规范相应的规定。短路电流倍数 无可靠数据时，可按断路器的断流容量确定最大短路电流，电缆芯线截面不应小 于 2. 5mm2 ；",{"key":24,"text":536,"correct":22},"电压回路：当全部保护装置和安全自动装置动作时（考虑到发展，电压互感器的负 荷最大时），电压互感器至保护和自动装置屏的电缆压降不应超过额定电压的3%。。电缆芯 线截面不应小于1.5mm2;",{"key":27,"text":538,"correct":22},"操作回路：在最大负荷下，操作母线至设备的电压降，不应超过额定电压的10%；;",{"key":30,"text":528,"correct":40},{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":32,"analysis":33},1035450,"当采用静态保护，根据保护装置的要求’在继电保护、自动装置、控制、信号的二 次回路内应采用（ ）抗干扰措施。",[544,546,548,550],{"key":20,"text":545,"correct":22},"A在电缆敷设时，首先应充分利用自然屏蔽物的屏蔽作用；",{"key":24,"text":547,"correct":22},"采用屏蔽电缆，屏蔽层宜在两端接地；",{"key":27,"text":549,"correct":22},"强电和弱电回路不宜合用同一根电缆；",{"key":30,"text":551,"correct":22},"保护用电缆与电力电缆不应同层敷设。",{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":338,"analysis":33},1035452,"直流主屏的布置地点宜为（ ）。",[556,558,560,562],{"key":20,"text":557,"correct":40},"蓄电池室；",{"key":24,"text":559,"correct":22},"蓄电池室附近单独的电源室内或电气继电器室；",{"key":27,"text":561,"correct":22},"对于网络控制室直流系统，也可布置在控制室内；",{"key":30,"text":563,"correct":40},"负荷中心处。",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":146,"analysis":33},1035455,"应监测交流系统绝缘的回路是（ ）。",[568,570,572,574],{"key":20,"text":569,"correct":22},"同步发电机的定子回路；",{"key":24,"text":571,"correct":40},"1lOkV中性点接地系统母线；",{"key":27,"text":573,"correct":22},"35kV中性点不接地系统母线；",{"key":30,"text":575,"correct":22},"IOkV中性点不接地系统母线。",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":588,"analysis":33},1035458,"宜计量有功电能的回路是（ ）。",[580,582,584,586],{"key":20,"text":581,"correct":22},"厂用电变压器高压侧；",{"key":24,"text":583,"correct":40},"厂用6kV线路；",{"key":27,"text":585,"correct":22},"高压电动机；",{"key":30,"text":587,"correct":40},"低压电动机.","AC",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":146,"analysis":33},1035461,"应计量无功电能的回路有（ ）。",[593,595,596,598],{"key":20,"text":594,"correct":22},"1lOkV变压器高压侧；",{"key":24,"text":583,"correct":40},{"key":27,"text":597,"correct":22},"1lOkV线路；",{"key":30,"text":599,"correct":22},"1OkV并联电容器。",{"id":601,"libraryId":5,"type":15,"typeLabel":16,"stem":602,"options":603,"answer":338,"analysis":33},1035464,"正确的有功、无功电能表接线形式是（ ）。",[604,606,608,610],{"key":20,"text":605,"correct":40},"中性点有效接地系统的电能表采用三相三线；",{"key":24,"text":607,"correct":22},"中性点有效接地系统的电能表应采用三相四线；",{"key":27,"text":609,"correct":22},"中性点非有效接地系统的电能表应采用三相三线;",{"key":30,"text":611,"correct":40},"中性点非有效接地系统的电能表采用三相四线。",{"id":613,"libraryId":5,"type":15,"typeLabel":16,"stem":614,"options":615,"answer":133,"analysis":33},1035466,"断路器控制回路接线，应满足的要求是（ ）。",[616,618,620,622],{"key":20,"text":617,"correct":22},"应有电源监视，并宜监视跳、合闸绕组回路的完整性，应能指示断路器合闸、跳闸 的位置状态；自动重合闸或跳闸时应有明显信号；",{"key":24,"text":619,"correct":22},"合闸或跳闸完成后应使命令脉冲自动解除，有防止断路器“跳跃”的自动闭锁装置；",{"key":27,"text":621,"correct":40},"有反映断路器故障跳闸时的故障信号；",{"key":30,"text":623,"correct":22},"接线应简单可靠，使用电缆芯最少。",[625,629,632,635,638,641],{"id":626,"name":627,"category":7,"favorite":628},1,"领导干部任职前廉政法规知识测试题",92,{"id":630,"name":631,"category":7,"favorite":626},595,"建筑结构与设备",{"id":633,"name":634,"category":7,"favorite":626},715,"招标采购专业知识与法律法规",{"id":636,"name":637,"category":7,"favorite":626},848,"市政方向-通用基础",{"id":639,"name":640,"category":7,"favorite":8},534,"BIM工程师",{"id":642,"name":640,"category":7,"favorite":8},535]