[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-38":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":625},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,38,50,2321,[13,35,48,61,74,87,100,113,125,134,146,158,170,182,190,202,214,226,238,250,262,274,286,299,311,323,335,347,359,371,383,395,407,419,432,444,456,469,481,493,505,517,529,541,553,565,577,589,601,613],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1035209,2,"多选题","在外部火势作用一定时间内需维持通电的场所或回路明敷的电缆应实施耐火防护或 选用具有耐火性的电缆的场所有（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","消防、报警、应急照明回路；",true,{"key":24,"text":25,"correct":26},"B","正常照明回路；",false,{"key":28,"text":29,"correct":22},"C","计算机监控、双重化继电保护、保安电源等双回路合用同一通道未相互隔离时其中 一个回路；",{"key":31,"text":32,"correct":22},"D","钢铁厂中可能有熔化金属溅落等易燃的场所。","ACD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1035211,"电缆用防火阻燃材料产品的选用，应符合的规定有（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":22},"用于阻止延燃的材枓产品，应按等效工程使用条件的燃烧试验满足有效自熄性；",{"key":24,"text":42,"correct":26},"用于耐火防护的材枓产品，应按等效工程使用条件的燃烧试验满足耐火极限不低于 2h的要求;",{"key":28,"text":44,"correct":26},"用于电力电缆的阻燃、耐火槽盒与电缆载流能力无关，而与使用场所的防火等级 有关》",{"key":31,"text":46,"correct":22},"采用的材料产品应适于工程环境，具有耐久可靠性。","AD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},1035214,"电缆的防火与阻燃设计应符合的规定有（）。",[52,54,56,58],{"key":20,"text":53,"correct":26},"同一通道中可以把非阻燃电缆与阻燃电缆并列配置；",{"key":24,"text":55,"correct":22},"同一通道中明敷电缆数量较少时，可采用涂防火涂料，包带或把电缆穿于耐火管中；",{"key":28,"text":57,"correct":22},"靠近高压含油设备的电缆沟，宜使该区段沟盖板密封；",{"key":31,"text":59,"correct":22},"在地下公共设施的电缆密集部位；多回充油电缆的终端设置处等安全性要求较高的 场所，可装设水喷雾灭火等专用消防设施。","BCD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},1035217,"( )情况下的电力电缆，应采用铜芯。",[65,67,69,71],{"key":20,"text":66,"correct":22},"耐火电缆；",{"key":24,"text":68,"correct":22},"振动剧烈、有爆炸危险；",{"key":28,"text":70,"correct":22},"对铝有腐蚀等严酷的工作环境；",{"key":31,"text":72,"correct":22},"电机励磁、重要电源、移动式电气设备等需要保持连接具有高可靠性的回路。","ABCD",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":86,"analysis":34},1035219,"用于（ ）情况下的电力电缆，宜采用铜芯。",[78,80,82,84],{"key":20,"text":79,"correct":22},"紧靠高温设备配置；",{"key":24,"text":81,"correct":22},"安全性要求高的重要公共设施中；",{"key":28,"text":83,"correct":22},"水下敷设或当工作电流较大需增多电缆根数时；",{"key":31,"text":85,"correct":26},"工业企业。","ABC",{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":99,"analysis":34},1035222,"当用于（），且技术经济比较合理时，可采用单芯电缆。",[91,93,95,97],{"key":20,"text":92,"correct":26},"工厂企业配电；",{"key":24,"text":94,"correct":22},"水下數设；",{"key":28,"text":96,"correct":22},"工作电流较大的回路；",{"key":31,"text":98,"correct":26},"重要建筑物。","BC",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":112,"analysis":34},1035225,"60℃以上（小于100℃)髙温场所，应按经受高温及其持续时间和绝缘类型要求, 选用（ ）适合的耐热型电缆。",[104,106,108,110],{"key":20,"text":105,"correct":22},"耐热聚氯乙烯电缆；",{"key":24,"text":107,"correct":22},"交联聚乙烯电缆；",{"key":28,"text":109,"correct":26},"C聚氯乙烯绝缘电缆；",{"key":31,"text":111,"correct":22},"乙丙橡皮绝缘电缆。","ABD",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":86,"analysis":34},1035227,"一 15℃以下低温环境，应按低温条件和绝缘类型要求，选用（ ）、耐寒橡皮绝缘 电缆。",[117,119,121,123],{"key":20,"text":118,"correct":22},"耐寒橡皮绝缘电缆；",{"key":24,"text":120,"correct":22},"交联聚乙烯绝缘电缆；",{"key":28,"text":122,"correct":22},"聚乙烯绝缘电缆；",{"key":31,"text":124,"correct":26},"聚氯乙烯绝缘电缆。",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":86,"analysis":34},1035230,"有低毒阻燃性防火要求的场所，可采用（ ）。",[129,130,131,133],{"key":20,"text":122,"correct":22},{"key":24,"text":120,"correct":22},{"key":28,"text":132,"correct":22},"C乙丙橡皮绝缘电缆；",{"key":31,"text":124,"correct":26},{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":86,"analysis":34},1035233,"直埋电缆外护层的选择，应符合（ ）规定。",[138,140,142,144],{"key":20,"text":139,"correct":22},"电缆承受较大压力或有机械损伤危险时，应有加强层或钢带铠装；",{"key":24,"text":141,"correct":22},"在流砂层、回填土地带等可能出现位移的土壤中，电缆应有钢丝铠装；",{"key":28,"text":143,"correct":22},"白蚁严重危害地区用的塑料电缆可加尼龙外套，也可采用金属套或钢带铠装；",{"key":31,"text":145,"correct":26},"一般情况采用带铠装的外护层。",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":73,"analysis":34},1035236,"空气中固定敷设电缆时的外护层选择，应符合（ ）规定。 A.敷设在桥架等支承较密集的电缆可不含铠装；",[150,152,154,156],{"key":20,"text":151,"correct":22},"小截面挤塑绝缘电缆直接在臂式支架上数设时，宜具有钢带铠装；",{"key":24,"text":153,"correct":22},"在地下客运、商业设施等安全性要求高而鼠害严重的场所，塑料绝缘电缆应具有金",{"key":28,"text":155,"correct":22},"属套或钢带铠装；",{"key":31,"text":157,"correct":22},"电缆位于高落差的受力条件需要时，多芯电缆应具有钢丝铠装。",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":73,"analysis":34},1035238,"( )情况的回路，相互间不宜合用同一根控制电缆。",[162,164,166,168],{"key":20,"text":163,"correct":22},"弱电信号与强电信号、控制回路；",{"key":24,"text":165,"correct":22},"低电平信号与高电平信号回路；",{"key":28,"text":167,"correct":22},"交流断路器分相操作的各相弱电控制回路；",{"key":31,"text":169,"correct":22},"控制回路与强电信号。",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":60,"analysis":34},1035241,"电力系统计箅机监测系统信号回路控制电缆的屏蔽选择，应符合（ ）要求。",[174,176,178,180],{"key":20,"text":175,"correct":26},"低电平模拟信号可不用对绞线分屏蔽；",{"key":24,"text":177,"correct":22},"开关量信号，可用总屏蔽；",{"key":28,"text":179,"correct":22},"高电平模拟信号，宜选用对绞线芯总屏蔽，必要时也可选用对绞线芯分屏蔽；",{"key":31,"text":181,"correct":22},"低电平模拟信号或脉冲量信号，宜选用对绞线分屏蔽，必要时也可对绞线芯分屏蔽 复合总屏蔽。",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":60,"analysis":34},1035243,"母线槽按结构形式分为（ ）。 A.密集式母线槽； B。馈电式母线槽； C.插接式母线槽； D.滑接式母线槽。",[186,187,188,189],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":73,"analysis":34},1035246,"电缆的路径选择应符合（ ）规定。",[194,196,198,200],{"key":20,"text":195,"correct":22},"避免电缆遭受机械外力、过热、腐蚀等危害；",{"key":24,"text":197,"correct":22},"满足安全要求条件下使电缆较短；",{"key":28,"text":199,"correct":22},"便于敷设、维护，避免将要挖掘施工的地方；",{"key":31,"text":201,"correct":22},"充油电缆线路通过起伏地形时，使供油装置合理分配。",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":112,"analysis":34},1035249,"同一层支架上电缆排列配置方式，应符合（ ）规定。",[206,208,210,212],{"key":20,"text":207,"correct":22},"控制和信号电缆可紧靠或多层迭置；",{"key":24,"text":209,"correct":22},"除交流系统用单芯电力电缆的同一回路可采取品字形（三叶形）配置外，对重要的 同一回路多根电力电缆，不宜迭置；",{"key":28,"text":211,"correct":26},"C电力电缆可紧靠或多层迭置；",{"key":31,"text":213,"correct":22},"除交流系统用单芯电力电缆外，电力电缆相互间宜有1倍电缆外径的空隙。",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":73,"analysis":34},1035252,"电缆支架应符合（）规定。",[218,220,222,224],{"key":20,"text":219,"correct":22},"表面光滑无毛刺；",{"key":24,"text":221,"correct":22},"适应使用环境的耐久稳固；",{"key":28,"text":223,"correct":22},"C满足所需承载能力；",{"key":31,"text":225,"correct":22},"符合工程防火要求。",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":86,"analysis":34},1035255,"不同回路、不同电压、不同电流种类的导线，不得穿入同一根管内。伹下列（ ） 情况除外。",[230,232,234,236],{"key":20,"text":231,"correct":22},"标称电压为50V以下回路；",{"key":24,"text":233,"correct":22},"同一花灯的几个回路；",{"key":28,"text":235,"correct":22},"一台电机的所有回路（包括操作回路）；",{"key":31,"text":237,"correct":26},"工作照明与亊故照明线路。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":73,"analysis":34},1035258,"3根以上绝缘导线穿同一根管时，导线的总截面不应大于管内净面积的40%，并应 满足（）要求。",[242,244,246,248],{"key":20,"text":243,"correct":22},"管子没有弯（90°~105°)时的长度不超过30m;",{"key":24,"text":245,"correct":22},"管子有1个穹（90°~105°)时的长度不超过2Om;",{"key":28,"text":247,"correct":22},"管子有2个弯（90°~10.5°)时的长庋不超过15m;",{"key":31,"text":249,"correct":22},"管子有3个弯（90°~105°)时的长度不超过8m。",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":73,"analysis":34},1035260,"跨越道路街道的低压接户线，至路面中心垂直距离不应小于（）。",[254,256,258,260],{"key":20,"text":255,"correct":22},"通车街道处6m;",{"key":24,"text":257,"correct":22},"通车困难的街道3. 5m;",{"key":28,"text":259,"correct":22},"胡同3m;",{"key":31,"text":261,"correct":22},"人行道3. 5m。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":47,"analysis":34},1035262,"爆炸性气体危险场所敷设电缆在可能范围应使电缆距爆炸释放源较远，敷设在爆炸 危检较小的场所。并应符合（ ）规定。",[266,268,270,272],{"key":20,"text":267,"correct":22},"易燃气体比空气重时，电缆应在较高处架空敷设，且对非铠装电缆采取穿管或置于 8 托盘、槽盒中等机械性保护；",{"key":24,"text":269,"correct":26},"易燃气体比空气轻时，电缆应在较高处架空敷设，且对非铠装电缆采取穿管或置于 托盘、槽盒中等机械性保护；",{"key":28,"text":271,"correct":26},"易燃气体比空气重时，电缆应敷设在较低处的管、沟内，沟内非铠装电缆应埋砂；",{"key":31,"text":273,"correct":22},"易燃气体比空气轻时，电缆应敷设在较低处的管、沟内，沟内非铠装电缆应埋砂。",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":99,"analysis":34},1035265,"电缆沿输送易燃气体的管道敷设时，应配置在危险程度较低的一侧，且应符合 ( )规定。",[278,280,282,284],{"key":20,"text":279,"correct":26},"易燃气体比空气轻时，电缆宜在管道上方；",{"key":24,"text":281,"correct":22},"易燃气体比空气重时，电缆宜在管道上方；",{"key":28,"text":283,"correct":22},"易燃气体比空气轻时，电缆宜在管道下方；",{"key":31,"text":285,"correct":26},"易燃气体比空气重时，电缆宜在管道下方。",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":298,"analysis":34},1035268,"非铠装电缆用于（ ）时，应采用具有机械强度的管或罩加以保护。",[290,292,294,296],{"key":20,"text":291,"correct":26},"非电气人员经常活动场所的地坪以上1m范围，地中引出的地坪下0.3m深电缆 区段；",{"key":24,"text":293,"correct":26},"非电气人员经常活动场所的地坪以上2m范围，地中引出的地坪下0.5m深电缆 区段；",{"key":28,"text":295,"correct":22},"非电气人员经常活动场所的地坪以上2m范围，地中引出的地坪下0.3m深电缆 区段；",{"key":31,"text":297,"correct":22},"可能有载重设备移经电缆的区段。","CD",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":73,"analysis":34},1035271,"电缆直埋敷设方式的选择，应符合（）规定。",[303,305,307,309],{"key":20,"text":304,"correct":22},"同一通路少于6根的35kV及以下电力电缆，在厂区通往远距辅助设施或城郊等不 易有经常性开挖的地段，宜用直埋；",{"key":24,"text":306,"correct":22},"b.厂区内地下管网较多的地段，可能有熔化金属、高温液体溢出的场所，待开发将有 较頻繁开挖的地方，不宜用直埋；",{"key":28,"text":308,"correct":22},"在化学腐蚀或杂散电流腐蚀的土壤范围，不得采用直埋；",{"key":31,"text":310,"correct":22},"在城镇人行道下较易翻修情况或道路边缘，也可用直埋。",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":86,"analysis":34},1035274,"电缆穿管敷设方式的选择，应符合（）规定。",[315,317,319,321],{"key":20,"text":316,"correct":22},"在有爆炸危险场所明敷的电缆，露出地坪上需加以保护的电缆，与公路、铁道交叉 时的地下电缆，应采用穿管；",{"key":24,"text":318,"correct":22},"地下电现通过房屋、广场的区段，电缆敷设在规划将作为道路的地段，宜用穿管；",{"key":28,"text":320,"correct":22},"c.在地下管网较密的工厂区，城市道路狭窄且交通繁忙或道路挖掘困难的通道等电缆 较多的情况下，可用穿管敷设；",{"key":31,"text":322,"correct":26},"在城镇人行道下或道路边缘宜用穿管敷设。",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":73,"analysis":34},1035276,"电缆沟敷设方式的选择，应符合（）规定。",[327,329,331,333],{"key":20,"text":328,"correct":22},"有化学腐蚀液体或高温熔化金属溢流的场所，或在载重车頻繁经过的地段，不得用 电缆沟；",{"key":24,"text":330,"correct":22},"经常有工业水溢流，可燃粉尘弥漫的厂房内，不宜用电缆沟；",{"key":28,"text":332,"correct":22},"城镇人行道开挖不便且电缆需分期敷设时，宜采用电缆沟；",{"key":31,"text":334,"correct":22},"有防爆、防火要求的明敷电缆，应采用埋砂敷设的电缆沟。",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":73,"analysis":34},1035278,"电缆隧道方式的选择，应符合（ ）规定。",[339,341,343,345],{"key":20,"text":340,"correct":22},"同一通道的地下电缆根数多，电缆沟不足以容纳时；",{"key":24,"text":342,"correct":22},"同一通道的地下电缆较多且位于有腐蚀性液体或经常有地面水流溢的场所；",{"key":28,"text":344,"correct":22},"含有35kV以上高压电缆，或穿越公路、铁道等地段；",{"key":31,"text":346,"correct":22},"受城镇地下通道限制或交通流量较大的道路下，与较多电缆沿同一路径有非髙溫的 水、气和通信电缆管线共同配置时。",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":73,"analysis":34},1035281,"直埋敷设电缆方式，应满足（）要求。",[351,353,355,357],{"key":20,"text":352,"correct":22},"电缆应敷设在壕沟里，沿电缆全长的上、下紧邻侧铺以厚度不少于1OOmm的软土 或砂层；",{"key":24,"text":354,"correct":22},"沿电缆全长应覆盖宽庋不小于电缆两侧各50mm的保护板，保护板宜用混凝土制作；",{"key":28,"text":356,"correct":22},"c.位于城镇道路等开挖较频繁的地方，宜在保护板上层铺以醒目的标志带；",{"key":31,"text":358,"correct":22},"位于城郊或空旷地帶，沿电缆路径的直线间隔约100m、转弯处或接头部位，应竖立 明显的方位标志或标桩。",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":60,"analysis":34},1035284,"直埋敷设于非冻土地区时，电缆埋置深度应符合（ ）规定。",[363,365,367,369],{"key":20,"text":364,"correct":26},"电缆外皮至地下构筑物基础，不得小于0.5m;",{"key":24,"text":366,"correct":22},"电缆外皮至地下构筑物基础’不得小于0.3m;",{"key":28,"text":368,"correct":22},"C电缆外皮至地面深度，不得小于0.7m;",{"key":31,"text":370,"correct":22},"当位于车行道或耕地下时，应适当加深，且不宜小于lm。",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":73,"analysis":34},1035287,"对电缆可能着火蔓延导致严重事故的回路，易受外部影响波及火灾的电缆密集场 所，应有适当的阻火分隔，并按工程重要性、火灾几率及其特点和经济合理等因素，确定采 取（）安全措施.",[375,377,379,381],{"key":20,"text":376,"correct":22},"实施阻燃防护或阻止延燃；",{"key":24,"text":378,"correct":22},"选用具有阻燃性的电缆；",{"key":28,"text":380,"correct":22},"实施耐火防护或选用具有耐火性的电缆",{"key":31,"text":382,"correct":22},"实施防火构造。",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":86,"analysis":34},1035290,"电缆支架的强度，应满足电缆及其附属件荷重和安装维护的受力要求，且应符合 ( )规定.",[387,389,391,393],{"key":20,"text":388,"correct":22},"有可能短暂上人时，计入900N的附加集中荷载；",{"key":24,"text":390,"correct":22},"机械化施工时，计算纵向拉力、横向推力和滑轮重量等影响；",{"key":28,"text":392,"correct":22},"在户外时，计入可能有覆冰、雪和大风的附加荷载；",{"key":31,"text":394,"correct":26},"上述附加荷载可不叠加。",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":73,"analysis":34},1035293,"电线管路与热水管、蒸汽管同侧敷设时，应敷设在热水管、蒸汽管的下面。有困难 时，可敷设在其上面，相互间的净距不宜小于（ ）数值。",[399,401,403,405],{"key":20,"text":400,"correct":22},"当管路敷设在热水管下面时为0.20m,上面时为0.30m;",{"key":24,"text":402,"correct":22},"当管路敷设在蒸汽管下面时为0. 50m,上面时为1m;",{"key":28,"text":404,"correct":22},"C当采取隔热措施时，对有保温措施的蒸汽管，上下净距均为0.20m;",{"key":31,"text":406,"correct":22},"电线管路与其他管道（不包括可燃气体及易燃、可燃液体管道）的平行净距不应小 于 0. 10m。",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":73,"analysis":34},1035295,"选择导体的一般原则是（ ）。",[411,413,415,417],{"key":20,"text":412,"correct":22},"应力求技术先进、安全实用，经济合理；",{"key":24,"text":414,"correct":22},"应满足正常运行、检修、短路情况下的要求，并考虑远景发展；",{"key":28,"text":416,"correct":22},"应按当地环境条件校核；",{"key":31,"text":418,"correct":22},"应与整个工程的建设标准协调一致。",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":431,"analysis":34},1035297,"验算导体的动、热稳定使用的短路电流应（ ）。",[423,425,427,429],{"key":20,"text":424,"correct":22},"按工程的设计规划容量计算；",{"key":24,"text":426,"correct":22},"考虑电力系统的远景发展规划；",{"key":28,"text":428,"correct":26},"按工程的本期建设容量；",{"key":31,"text":430,"correct":26},"按工程的近期建设容量。","AB",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":86,"analysis":34},1035300,"验箅导体的短路电流应按（）计算。",[436,438,440,442],{"key":20,"text":437,"correct":22},"可能发生最大短路电流的正常接线方式；",{"key":24,"text":439,"correct":22},"除计算短路电流的衰减时间常数和低压网络的短路电流外，元件的电阻都略去不计；",{"key":28,"text":441,"correct":22},"在电气连接的网络中，应考虑具有反馈作用的异步电动机的影响和电容补偿装置放 电电流的影响；",{"key":31,"text":443,"correct":26},"在电气连接的网络中，不考虑具有反馈作用的异步电动机的影响。",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":60,"analysis":34},1035303,"除环境温度外，室外裸导体还应按（）环境条件校验。",[448,450,452,454],{"key":20,"text":449,"correct":26},"环境湿度；",{"key":24,"text":451,"correct":22},"日照；",{"key":28,"text":453,"correct":22},"风速；",{"key":31,"text":455,"correct":22},"污秽。",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":468,"analysis":34},1035306,"直流供电回路电缆芯数选择为（）。",[460,462,464,466],{"key":20,"text":461,"correct":22},"宜采用两芯电缆；",{"key":24,"text":463,"correct":26},"采用三芯电缆；",{"key":28,"text":465,"correct":22},"当需要时可采用单芯电缆；",{"key":31,"text":467,"correct":26},"采用四芯电缆。","AC",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":431,"analysis":34},1035309,"交流系统中电力电缆缆芯与绝缘屏蔽或金属套之间额定电压的选择，应符合的规定 有（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":22},"中性点直接接地或经低阻抗接地的系统当接地保护动作不超过1min切除故障时， 应按100%的使用回路工作相电压；",{"key":24,"text":476,"correct":22},"对于A项外的供电系统，不宜低于133%的使用回路工作相电压；",{"key":28,"text":478,"correct":26},"在单项接地故障可能持续5h以上，或发电机回路等安全性要求较高的情况，宜采用 173%的使用回路工作相电压；",{"key":31,"text":480,"correct":26},"交流系统中电缆的冲击耐压水平，宜满足系统绝缘配合要求。",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":73,"analysis":34},1035310,"电缆的外护层，应符合的要求有（ ）。",[485,487,489,491],{"key":20,"text":486,"correct":22},"交流单芯电力电缆，不得有未经非磁性处理的金属带、钢丝铠装；",{"key":24,"text":488,"correct":22},"在潮湿、含化学腐蚀环境或易受水浸泡的电缆，其金属套、加强层、铠装上应有聚 乙烯外护层，水中电缆的粗钢丝铠装应有挤塑外护层；",{"key":28,"text":490,"correct":22},"除低温-15℃C以下环境或化学液体浸泡场所，以及有低毒难燃性防火要求的电缆挤 塑外护层宜用聚乙烯外，可采用聚氯乙烯外护层；",{"key":31,"text":492,"correct":22},"用在有水或化学液体浸泡场所的6~35kV重要回路或35kV以上交联聚乙烯电缆， 应具有符合使用要求的金属塑料复合阻水层、金属套等径向防水构造。",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":112,"analysis":34},1035313,"放射线作用场所的电缆，应选用具有适合耐受放射线辐照强度的外护层的类型 有（ ）。",[497,499,501,503],{"key":20,"text":498,"correct":22},"聚氯乙烯；",{"key":24,"text":500,"correct":22},"氯丁橡皮；",{"key":28,"text":502,"correct":26},"交联聚乙烯；",{"key":31,"text":504,"correct":22},"氯磺化聚乙烯。",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":73,"analysis":34},1035316,"电缆允许载流量校正系数计人了下列条件中的（ ）。",[509,511,513,515],{"key":20,"text":510,"correct":22},"环境温度差异；",{"key":24,"text":512,"correct":22},"直埋敷设时土壤热阻系数差异；",{"key":28,"text":514,"correct":22},"电缆多根并列的影响；",{"key":31,"text":516,"correct":22},"户外架空敷设无遮阳时的日照影响。",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":73,"analysis":34},1035319,"架空线路设计的一般要求为（）。",[521,523,525,527],{"key":20,"text":522,"correct":22},"架空线路应沿道路平行敷设，宜避免通过各种起重机频繁活动地区和各种露天堆场；",{"key":24,"text":524,"correct":22},"应尽量减少与其他设施的交叉和跨越建筑物；",{"key":28,"text":526,"correct":22},"接近有爆炸物、易燃物和可燃气（液）体的厂房、仓库等设施，应符合GB50058— 1992《爆炸和火灾危险环境电力设计规范》；",{"key":31,"text":528,"correct":22},"架空线路不应采用单股的铝线或铝合金线，髙压线路不应采用单股铜线.",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":33,"analysis":34},1035322,"架空线路导体截面不应小于（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":22},"35kV线路铝绞线及铝合金线：35mm2;",{"key":24,"text":536,"correct":26},"35kV线路钢芯铝绞线：25mm2;",{"key":28,"text":538,"correct":22},"居民区10kV线路铝绞线及铝合金线：35mm2;",{"key":31,"text":540,"correct":22},"居民区10kV线路钢芯铝绞线：25mm2,",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":468,"analysis":34},1035324,"架空线路的导线与地面的最小距离为（）。",[545,547,549,551],{"key":20,"text":546,"correct":22},"35kV线路居民区为7m;",{"key":24,"text":548,"correct":26},"10kV线路居民区为6m;",{"key":28,"text":550,"correct":22},"35kV线路非居民区为6m;",{"key":31,"text":552,"correct":26},"10kV线路非居民区为5m。",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":86,"analysis":34},1035327,"架空线路的导线与建筑物的最小距离为（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":22},"35kV线路导线跨越建筑物垂直距离（最大计算弧垂）为4m;",{"key":24,"text":560,"correct":22},"10kV线路导线跨越建筑物垂直距离（最大计算弧垂）为3m;",{"key":28,"text":562,"correct":22},"35kV线路边导线与建筑物水平距离（最大计算风偏）为3m;",{"key":31,"text":564,"correct":26},"10kV线路边导线与建筑物水平距离（最大计算风偏）为2m。",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":112,"analysis":34},1035329,"架空线接户线的截面不应小于（ ）。",[569,571,573,575],{"key":20,"text":570,"correct":22},"10kV高压接户线的铝绞线：25mm2;",{"key":24,"text":572,"correct":22},"10kV高压接户线的铜绞线：16mm2;",{"key":28,"text":574,"correct":26},"lkV以下低压接户线自电杆档距z;",{"key":31,"text":576,"correct":22},"lkV以下低压接户线自电杆引下档距为10~25m时绝缘铝线：6mm2",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":112,"analysis":34},1035332,"架空线接户线的对地距离不应小于（ ）。",[581,583,585,587],{"key":20,"text":582,"correct":22},"10kV高压接户线为4. 5m；",{"key":24,"text":584,"correct":22},"lkV以下低压接户线为2. 5m；",{"key":28,"text":586,"correct":26},"低压接户线至路面中心的垂直距离（通车道）5m;",{"key":31,"text":588,"correct":22},"低压接户线至路面中心的垂直距离（人行道）3.5m。",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":47,"analysis":34},1035335,"架空线路与下列设施的最小垂直距离为（ ）。",[593,595,597,599],{"key":20,"text":594,"correct":22},"35kV线路与铁路轨顶为7. 5m；",{"key":24,"text":596,"correct":26},"10kV线路与公路路面为6m;",{"key":28,"text":598,"correct":26},"10kV线路与电车道路面为8m;",{"key":31,"text":600,"correct":22},"1 OkV线路与铁路轨顶为7. 5m。",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":112,"analysis":34},1035337,"架空线路与架空线路跨越时最小垂直距离为（）。",[605,607,609,611],{"key":20,"text":606,"correct":22},"35kV线路跨越10kV线路时为3.0m;",{"key":24,"text":608,"correct":22},"10kV线路跨越10kV线路时为2. 0m；",{"key":28,"text":610,"correct":26},"10kV线路跨越lkV以下线路时为1. Om；",{"key":31,"text":612,"correct":22},"lkV以下线路跨越lkV以下线路为1. Om。",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":73,"analysis":34},1035340,"架空线路与架空线路、架空明线弱电线路敷设要求为（）。",[617,619,621,623],{"key":20,"text":618,"correct":22},"电压较高的线路一般架设在电压较低线路的上方；",{"key":24,"text":620,"correct":22},"电力接户线与相同电压或较低电压的专用线交叉，电力接户线宜设在上方；",{"key":28,"text":622,"correct":22},"电力线路应架设在明线弱电线路上方；",{"key":31,"text":624,"correct":22},"电力线路与明线弱电线路之间应按过电压保护要求确定。",[626,630,633,636,639,642],{"id":627,"name":628,"category":7,"favorite":629},1,"领导干部任职前廉政法规知识测试题",92,{"id":631,"name":632,"category":7,"favorite":627},595,"建筑结构与设备",{"id":634,"name":635,"category":7,"favorite":627},715,"招标采购专业知识与法律法规",{"id":637,"name":638,"category":7,"favorite":627},848,"市政方向-通用基础",{"id":640,"name":641,"category":7,"favorite":8},534,"BIM工程师",{"id":643,"name":641,"category":7,"favorite":8},535]