[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-37":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":615},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,37,50,2321,[13,35,47,60,73,86,99,111,123,135,147,159,171,179,189,197,205,218,230,243,255,266,277,290,302,314,327,340,352,365,376,388,399,411,423,435,447,459,471,483,495,507,519,531,543,555,567,579,591,603],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1035072,2,"多选题","低压配电线路应装设的保护有（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","短路保护；",true,{"key":24,"text":25,"correct":22},"B","过负载保护；",{"key":27,"text":28,"correct":22},"C","接地故障保护；",{"key":30,"text":31,"correct":32},"D","低电压保护。",false,"ABC","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":33,"analysis":34},1035075,"低压保护电器应能满足（ ）要求。",[39,41,43,45],{"key":20,"text":40,"correct":22},"发生故障时，作用于切断电源或发出报警信号;",{"key":24,"text":42,"correct":22},"在正常运行或设备正常起动时不应动作；",{"key":27,"text":44,"correct":22},"上下级保护电器动作应有选择性；",{"key":30,"text":46,"correct":32},"有自动重合闸功能。",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":59,"analysis":34},1035078,"用作低压保护电器的有（）。 A.熔断器；",[51,53,55,57],{"key":20,"text":52,"correct":22},"断路器；",{"key":24,"text":54,"correct":22},"接触器；",{"key":27,"text":56,"correct":32},"电涌保护器（SP",{"key":30,"text":58,"correct":32},"。","AB",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":34},1035080,"低压配电线路的短路保护与（ ）因素有关。",[64,66,68,70],{"key":20,"text":65,"correct":32},"配电系统的接地型式；",{"key":24,"text":67,"correct":22},"保护电器的特性和参数",{"key":27,"text":69,"correct":22},"导体材料和绝缘种类；",{"key":30,"text":71,"correct":22},"导线截面。","BCD",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":85,"analysis":34},1035083,"短路保护的保护电器应装设在（ ）。",[77,79,81,83],{"key":20,"text":78,"correct":22},"配电线路的首端；",{"key":24,"text":80,"correct":32},"较长配电线路的中间位置；",{"key":27,"text":82,"correct":32},"配电线路的末端；",{"key":30,"text":84,"correct":22},"配电线路线芯我面减小处或分支处。","AD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":98,"analysis":34},1035086,"保护电器装设位置要求（ ）。",[90,92,94,96],{"key":20,"text":91,"correct":22},"在操作维护方便处；",{"key":24,"text":93,"correct":22},"不靠近可燃物；",{"key":27,"text":95,"correct":32},"在人的伸臂范围外；",{"key":30,"text":97,"correct":22},"不易受机械损伤处。","ABD",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":59,"analysis":34},1035089,"从高处的配电干线向下引接的分支线路的保护电器，装设在距连接点的线路长度大 于3m的地方时，应满足的条件有（ ）。",[103,105,107,109],{"key":20,"text":104,"correct":22},"在装保护电器前那一段分支线路发生短路或接地故障时，上一级保护电器应能按规 定要求动作；",{"key":24,"text":106,"correct":22},"该段分支线应敷设于不燃或难燃的管、槽内；",{"key":27,"text":108,"correct":32},"C该段分支线应选用耐火电缆；",{"key":30,"text":110,"correct":32},"该分支线的保护电器的防护等级不应低于IP44。",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":72,"analysis":34},1035092,"低压配电线路接地故障保护应具有如下（）功能.",[115,117,119,121],{"key":20,"text":116,"correct":32},"人身直接电击；",{"key":24,"text":118,"correct":22},"人身间接电击；",{"key":27,"text":120,"correct":22},"电气火灾；",{"key":30,"text":122,"correct":22},"线路对地绝缘损坏。",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":98,"analysis":34},1035094,"接地故障保护电器应根据（ ）等因素选择。",[127,129,131,133],{"key":20,"text":128,"correct":22},"配电系统接地型式；",{"key":24,"text":130,"correct":22},"导体截面；",{"key":27,"text":132,"correct":32},"导线敷设方式；",{"key":30,"text":134,"correct":22},"电气设备是固定式，还是手握式、移动式。",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":98,"analysis":34},1035097,"防人身间接电击保护采用以下措施之一者，可不设接地故障保护，这些措施 是（ ）。",[139,141,143,145],{"key":20,"text":140,"correct":22},"采用防触电分类为Ⅱ类的电气设备；",{"key":24,"text":142,"correct":22},"采用安全超低电压;",{"key":27,"text":144,"correct":32},"已装设了完善的短路保护者;",{"key":30,"text":146,"correct":22},"采取电气隔离措施.",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":33,"analysis":34},1035100,"采用接地故障保护时，建筑物内应作等电位连接的导电体有（）。 A. P",[151,153,155,157],{"key":20,"text":152,"correct":22},"PEN干线，接地干线；",{"key":24,"text":154,"correct":22},"各种金属管道；",{"key":27,"text":156,"correct":22},"建筑物的金属构件；",{"key":30,"text":158,"correct":32},"隔离变压器二次侧回路。",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":33,"analysis":34},1035103,"电气装置或其一部分的接地故障保护不能满足切断故障回路时间要求，采取的措施 有（ ）。",[163,165,167,169],{"key":20,"text":164,"correct":22},"调整保护电器参数；",{"key":24,"text":166,"correct":22},"在局部范围内作辅助等电位联结；",{"key":27,"text":168,"correct":22},"采用防触电类别为II类设备；",{"key":30,"text":170,"correct":32},"采用防护等级不低于IP5X的电气设备。",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":72,"analysis":34},1035105,"TN系统作接地故障保护，配电箱引出线中既有供固定设备的线路，又有供手握式 或移动式设备的线路时，应采用下列措施（ ）之一。 A.引出的所有线路，切断故障回路的时间均不大于0.25s;",[175,176,177,178],{"key":20,"text":20,"correct":32},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":59,"analysis":34},1035108,"用作配电线路短路保护的电器有（ ）。",[183,184,186,187],{"key":20,"text":52,"correct":22},{"key":24,"text":185,"correct":22},"熔断器；",{"key":27,"text":54,"correct":32},{"key":30,"text":188,"correct":32},"漏电电流保护器。",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":59,"analysis":34},1035111,"用作配电线路过负荷保护的电器有（ ）。",[193,194,195,196],{"key":20,"text":52,"correct":22},{"key":24,"text":185,"correct":22},{"key":27,"text":54,"correct":32},{"key":30,"text":188,"correct":32},{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":98,"analysis":34},1035114,"TN系统的配电线路，作接地故障保护的电器有（ ）。",[201,202,203,204],{"key":20,"text":52,"correct":22},{"key":24,"text":185,"correct":22},{"key":27,"text":54,"correct":32},{"key":30,"text":188,"correct":22},{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":217,"analysis":34},1035117,"TN系统采用熔断器或断路器作接地故障保护，不能满足规定时间内动作的要求时, 可采取的措施有（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"加大相导体截面；.",{"key":24,"text":212,"correct":32},"加大中性线截面；",{"key":27,"text":214,"correct":22},"C加大PE线截面；",{"key":30,"text":216,"correct":22},"采用漏电电流保护器。","ACD",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":217,"analysis":34},1035120,"TT系统采用熔断器或断路器作接地故障保护不能满足规定时间内动作的要求时， 可采取的措施有（）。",[222,224,226,228],{"key":20,"text":223,"correct":22},"采用漏电电流保护器；",{"key":24,"text":225,"correct":32},"加大相导体截面；",{"key":27,"text":227,"correct":22},"降低变压器中性点接地电阻；",{"key":30,"text":229,"correct":22},"降低外露可导电部分的接地电阻。",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":242,"analysis":34},1035123,"TN—C系统末端线路用漏电电流保护器作接地故障保护时，其外露可导电部分的 接地可采用（ ）方式。",[234,236,238,240],{"key":20,"text":235,"correct":32},"TN—C；",{"key":24,"text":237,"correct":22},"局部 TN—S;",{"key":27,"text":239,"correct":22},"局部 TT;",{"key":30,"text":241,"correct":32},"局部 IT。","BC",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":59,"analysis":34},1035125,"用作配电线路过负荷保护的电器元件有（ ）。",[247,249,251,253],{"key":20,"text":248,"correct":22},"熔断器的熔断体；",{"key":24,"text":250,"correct":22},"断路器的长延时过电流脱扣器；",{"key":27,"text":252,"correct":32},"断路器的短延时过电流脱扣器；",{"key":30,"text":254,"correct":32},"断路器的瞬时过电流脱扣器。",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":72,"analysis":34},1035127,"不能用作配电线路过负荷保护的电器元件有（）。",[259,260,262,264],{"key":20,"text":248,"correct":32},{"key":24,"text":261,"correct":22},"断路器的短延时过电流脱扣器;",{"key":27,"text":263,"correct":22},"断路器的瞬时过电流脱扣器；",{"key":30,"text":265,"correct":22},"接触器.",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":33,"analysis":34},1035130,"系统短路容量为200MVA, 10\u002F0. 4kV、500kVA变压器低压屏引出线之保护电器 可以选用的类型有（ ）。",[270,271,273,275],{"key":20,"text":185,"correct":22},{"key":24,"text":272,"correct":22},"开启式（万能式）断路器；",{"key":27,"text":274,"correct":22},"塑壳断路器；",{"key":30,"text":276,"correct":32},"微型断路器。",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":289,"analysis":34},1035133,"系统短路容量为300MV A，10\u002F0. 4kV、1600kVA变压器低压屏引出线之保护电器 可以选用的类型有（ ）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"NT型熔断器；",{"key":24,"text":284,"correct":32},"分断能力为30kA的塑壳断路器；",{"key":27,"text":286,"correct":22},"分断能力为50kA的塑壳断路器；",{"key":30,"text":288,"correct":32},"高分断的微型断路器。","AC",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":85,"analysis":34},1035136,"为保证有选择性动作，变压器低压屏引出线的保护电器宜采用（ ）。",[294,296,298,300],{"key":20,"text":295,"correct":22},"gG型熔断器；",{"key":24,"text":297,"correct":32},"aM型熔断器；",{"key":27,"text":299,"correct":32},"带长延时及瞬时过电流脱扣器的断路器；",{"key":30,"text":301,"correct":22},"带长延时、短延时及瞬时过电流脱扣器的断路器。",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":85,"analysis":34},1035139,"TN—C系统的PEN线装设电器，下面说法正确的是（ ）。",[306,308,310,312],{"key":20,"text":307,"correct":22},"不应装设开关电器；",{"key":24,"text":309,"correct":32},"可以装设开关电器，不应装设保护电器；",{"key":27,"text":311,"correct":32},"应同时断开各相相线和PEN线时，可装设开关电器；",{"key":30,"text":313,"correct":22},"装设保护电器时，只能断开相应的相线回路。",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":326,"analysis":34},1035142,"下列场所和条件不应采用TN—C系统的是（ )。",[318,320,322,324],{"key":20,"text":319,"correct":22},"火灾和爆炸危险场所；",{"key":24,"text":321,"correct":22},"特别潮湿场所；",{"key":27,"text":323,"correct":22},"无专人维护的民用场所；",{"key":30,"text":325,"correct":22},"3次谐波含量很大的配电线路。","ABCD",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":339,"analysis":34},1035145,"IT系统适宜于（ ）场所应用。",[331,333,335,337],{"key":20,"text":332,"correct":32},"防电击要求很高的场所；",{"key":24,"text":334,"correct":32},"居住建筑；",{"key":27,"text":336,"correct":22},"供电不间断要求很高的场所；",{"key":30,"text":338,"correct":22},"应急系统。","CD",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":326,"analysis":34},1035148,"TN_S系统，配电线路的N线和相线同截面，N线上装设电器的要求为（ ）。",[344,346,348,350],{"key":20,"text":345,"correct":22},"N线可不装保护电器；",{"key":24,"text":347,"correct":22},"N线不宜装开关电器；",{"key":27,"text":349,"correct":22},"需装保护电器时，应切断相应相线，不必断开N线；",{"key":30,"text":351,"correct":22},"需要断开N线时，应装设同时切断相应相线和N线的保护电器。",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":364,"analysis":34},1035149,"TN—C系统，配电变压器低压配电屏引出线宜选择的保护电器类型有（）。",[356,358,360,362],{"key":20,"text":357,"correct":32},"带瞬时和长延时过电流脱扣器的断路器；",{"key":24,"text":359,"correct":22},"有填料封闭型熔断器；",{"key":27,"text":361,"correct":32},"带漏电保护的断路器；",{"key":30,"text":363,"correct":22},"带长延时和短延时、瞬时过电流脱扣器的断路器.","BD",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":98,"analysis":34},1035152,"IT系统的低压配电线路，当外露可导电部分为共同接地，发生第二次接地故障时， 应选择的保护电器有（）。",[369,370,372,374],{"key":20,"text":185,"correct":22},{"key":24,"text":371,"correct":22},"断路器;",{"key":27,"text":373,"correct":32},"絶缘监视器；",{"key":30,"text":375,"correct":22},"漏电电流保护器.",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":33,"analysis":34},1035155,"低压隔离开关具有（ ）功能。",[380,382,384,386],{"key":20,"text":381,"correct":22},"隔离功能；",{"key":24,"text":383,"correct":22},"接通正常电流；",{"key":27,"text":385,"correct":22},"C必要时，可接通一定值的短路电流；",{"key":30,"text":387,"correct":32},"必要时，可分断一定倍数的短路电流。",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":59,"analysis":34},1035158,"630kVA配电.变压器，从其低压配电屏引出供本变电所的照明线路，计箅电流为 10A,其保护电器可选用（ ）。",[392,393,395,397],{"key":20,"text":185,"correct":22},{"key":24,"text":394,"correct":22},"塑壳式断路器；",{"key":27,"text":396,"correct":32},"普通微型断路器;",{"key":30,"text":398,"correct":32},"带短延时过电流脱扣器的断路器.",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":98,"analysis":34},1035161,"3~35kV配电装置导体设计一般要求有（ ）。",[403,405,407,409],{"key":20,"text":404,"correct":22},"导体允许电流不小于该回路的最大持续工作电流；",{"key":24,"text":406,"correct":22},"动热稳定电流应按设计规划容量计算并应考虑电力系统远景规划发展计算数值；",{"key":27,"text":408,"correct":32},"C采用高压限流熔断器保护的导体可不根据限流熔断器的特性校验热稳定；",{"key":30,"text":410,"correct":22},"检验动热稳定短路电流计算值应取三相、两相、单相接地中的最大者。",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":326,"analysis":34},1035164,"选择低压配电系统导体截面时应满足的要求有（）。",[415,417,419,421],{"key":20,"text":416,"correct":22},"a.线路电压损失应满足用电设备正常工作及起动时端电压的要求；",{"key":24,"text":418,"correct":22},"b.按敷设方式及环境条件确定的导体载流量，不应小于计算电流；",{"key":27,"text":420,"correct":22},"c.导体应满足动稳定与热稳定的要求；",{"key":30,"text":422,"correct":22},"d.导体最小截面应满足机械强度的要求。",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":217,"analysis":34},1035166,"关于导体和导体、导体和电器的连接，下列描述正确的有（ )。",[427,429,431,433],{"key":20,"text":428,"correct":22},"a.硬导体间的连接宜采用焊接；",{"key":24,"text":430,"correct":32},"b.硬导体间的连接宜采用螺栓连接；",{"key":27,"text":432,"correct":22},"c.铝导体和铜导体间的连接根据环境条件须装设过渡接头；",{"key":30,"text":434,"correct":22},"d.导体和电器端子的连接处，应采用螺栓连接。",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":242,"analysis":34},1035168,"在三相四线制配电系统中，中性线的允许载流量应（ ）。",[439,441,443,445],{"key":20,"text":440,"correct":32},"不小于最大相线电流；",{"key":24,"text":442,"correct":22},"不小于线路中最大不平衡负荷电流.",{"key":27,"text":444,"correct":22},"应计入谐波电流影响；",{"key":30,"text":446,"correct":32},"不大于最大相线电流。",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":98,"analysis":34},1035171,"导线敷设处的环境温度，应采用下列温度值（ ）。",[451,453,455,457],{"key":20,"text":452,"correct":22},"a.直埋电缆，采用敷设处历年最热月的月平均温度；",{"key":24,"text":454,"correct":22},"b.敷设在空气中的裸导体，屋外采用该地区最热月的平均最高温度；",{"key":27,"text":456,"correct":32},"c.敷设在空气中的裸导体，屋内采用该地点最热月的平均最高温度；",{"key":30,"text":458,"correct":22},"d.敷设在空气中的裸导体，屋内采用该地点设计通风溫度。",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":33,"analysis":34},1035174,"电缆外护层类型选择应符合（）。",[463,465,467,469],{"key":20,"text":464,"correct":22},"a.单芯电力电缆用经非磁性处理的钢带；",{"key":24,"text":466,"correct":22},"b.受压较大或有机械损伤危险时用钢带铠装；",{"key":27,"text":468,"correct":22},"c.受高落差拉力时用钢丝铠装；",{"key":30,"text":470,"correct":32},"d.移动式电气设备用电缆采用聚乙烯外护层。",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":72,"analysis":34},1035177,"下列关于电缆绝缘水平说法正确的有（ ）。",[475,477,479,481],{"key":20,"text":476,"correct":32},"a.中性点直接接地系统中，电力电缆芯与绝缘屏蔽层间额定电压应不低于使用回路 133%工作相电压；",{"key":24,"text":478,"correct":22},"b.交流系统中电力电缆缆芯间额定电压不应低于使用回路的工作线电压；",{"key":27,"text":480,"correct":22},"c.交流系统中电缆的沖击耐压水平应满足系统绝缘配合要求；",{"key":30,"text":482,"correct":22},"d.控制电缆额定电压应不低于该回路工作电压。",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":59,"analysis":34},1035180,"改善大电流母线附近钢构发热的措施有（ ）。",[487,489,491,493],{"key":20,"text":488,"correct":22},"在钢构附近适当部位加装屏蔽环；",{"key":24,"text":490,"correct":22},"断开钢构闭合回路，钢构回路宜用绝缘板或绝缘垫断开；",{"key":27,"text":492,"correct":32},"采用三相分筒母线；",{"key":30,"text":494,"correct":32},"放置在母线与钢构间的屏蔽板应一端短接。",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":72,"analysis":34},1035183,"校验硬导体截面应（）。",[499,501,503,505],{"key":20,"text":500,"correct":32},"对35kV及以上电压的母线按电晕电压校验;",{"key":24,"text":502,"correct":22},"按短路热稳定校验；",{"key":27,"text":504,"correct":22},"按短路动稳定校验；",{"key":30,"text":506,"correct":22},"按机械共振条件校验。",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":326,"analysis":34},1035185,"配电装置软导线选择一般要考虑（ ）。",[511,513,515,517],{"key":20,"text":512,"correct":22},"无线电干扰；",{"key":24,"text":514,"correct":22},"回路负荷电流；",{"key":27,"text":516,"correct":22},"高压导线电晕问题；",{"key":30,"text":518,"correct":22},"沿海及污秽地区腐蚀.",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":98,"analysis":34},1035187,"软导线的截面选择和校验按（ ）进行.",[523,525,527,529],{"key":20,"text":524,"correct":22},"回路持续工作电流；",{"key":24,"text":526,"correct":22},"经济电流密度；",{"key":27,"text":528,"correct":32},"短路动稳定校验；",{"key":30,"text":530,"correct":22},"短路热稳定校验。",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":98,"analysis":34},1035190,"电缆路径选择要求有（ ）。",[535,537,539,541],{"key":20,"text":536,"correct":22},"尽量缩短电缆长庋；",{"key":24,"text":538,"correct":22},"方便敷设、维护；",{"key":27,"text":540,"correct":32},"避开绿地；",{"key":30,"text":542,"correct":22},"避开将挖掘施工地段。",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":33,"analysis":34},1035193,"在公路、铁道桥上敷设电缆要采取的措施有（ ）。",[547,549,551,553],{"key":20,"text":548,"correct":22},"不得敷设在通行的路面上",{"key":24,"text":550,"correct":22},"防火及抗震；",{"key":27,"text":552,"correct":22},"35kV及以上大截面电缆宜以蛇形敷设；",{"key":30,"text":554,"correct":32},"穿绝缘管。",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":98,"analysis":34},1035196,"电力电缆不宜直埋敷设的情况有（ ）。",[559,561,563,565],{"key":20,"text":560,"correct":22},"腐蚀性土壌；",{"key":24,"text":562,"correct":22},"待开发将有较频繁开挖的地段；",{"key":27,"text":564,"correct":32},"绿化地带；",{"key":30,"text":566,"correct":22},"厂区管道密集地带。",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":217,"analysis":34},1035198,"电力电缆宜采用隧道敷设的条件是（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":22},"电缆数量多（18根以上）、电缆沟不足以容纳时；",{"key":24,"text":574,"correct":32},"防火要求高的地区；",{"key":27,"text":576,"correct":22},"电缆数量较多穿越公路、狭路地段；",{"key":30,"text":578,"correct":22},"电缆数量较多、经常有地面水溢流的地区。",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":217,"analysis":34},1035201,"直埋敷设电缆相互之间最小距离应为（ ）。",[583,585,587,589],{"key":20,"text":584,"correct":22},"1OkV及以下电力电缆之间平行为0. 1m;",{"key":24,"text":586,"correct":32},"1OkV及以下电力电缆之间平行为0.25m;",{"key":27,"text":588,"correct":22},"1OkV以上电力电缆之间平行为0. 25m；",{"key":30,"text":590,"correct":22},"1OkV以上电力电缆之间交叉为0. 5m。.",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":326,"analysis":34},1035203,"电缆阻火分隔方式的选择应符合的规定有（）。",[595,597,599,601],{"key":20,"text":596,"correct":22},"电缆贯穿隔墙、楼板的孔洞处应实施阻火封堵；",{"key":24,"text":598,"correct":22},"在竖井中宜每隔约7m设置阻火隔层；",{"key":27,"text":600,"correct":22},"在竖井贯穿楼板处应实施阻火封堵；",{"key":30,"text":602,"correct":22},"至控制室的沟道入口处宜设置阻火墙。",{"id":604,"libraryId":5,"type":15,"typeLabel":16,"stem":605,"options":606,"answer":85,"analysis":34},1035206,"实施阻火分隔的技术特性应符合的规定有（）。",[607,609,611,613],{"key":20,"text":608,"correct":22},"在楼板竖井孔处的阻火隔层应能承受巡视人员的荷载；",{"key":24,"text":610,"correct":32},"阻火墙可全部用无机堵料构成；",{"key":27,"text":612,"correct":32},"在长距离隧道中有防止窜燃措施时可不设防火门；",{"key":30,"text":614,"correct":22},"防窜燃方式，可在阻火墙紧靠两侧不少于1m区段所有电缆上施加防火涂料等。",[616,620,623,626,629,632],{"id":617,"name":618,"category":7,"favorite":619},1,"领导干部任职前廉政法规知识测试题",92,{"id":621,"name":622,"category":7,"favorite":617},595,"建筑结构与设备",{"id":624,"name":625,"category":7,"favorite":617},715,"招标采购专业知识与法律法规",{"id":627,"name":628,"category":7,"favorite":617},848,"市政方向-通用基础",{"id":630,"name":631,"category":7,"favorite":8},534,"BIM工程师",{"id":633,"name":631,"category":7,"favorite":8},535]