[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-36":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":560},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,36,50,2321,[13,35,48,61,70,83,96,108,116,128,141,153,165,177,190,202,214,222,234,242,254,266,277,289,301,313,325,337,349,356,363,375,387,394,401,409,416,423,430,437,444,456,468,480,492,504,517,525,537,548],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1034936,2,"多选题","下面关于污秽等级的叙述正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","工业区和人口低密集区，在污闪季节中干燥少雾（含毛毛雨）或面量较多时，为O 级污秽等级；",false,{"key":24,"text":25,"correct":26},"B","轻盐碱和炉烟污秽地区，在污闪季节中潮湿多雾（含毛毛雨）但雨量较少时，为Ⅱ 级污秽等级；",true,{"key":28,"text":29,"correct":26},"C","重雾和重盐碱地区，工业人口密度较大地区，为Ⅲ级汚秽等级；",{"key":31,"text":32,"correct":26},"D","大气特别严重污染地区，离化学污源和炉烟污秽300m以内地区，为Ⅳ级污秽等级。","BCD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1034939,"对于高海拔地区电器的选用，下面各项说法中正确的是（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":26},"在高原地区，由于气温降低足够补偿海拔对温升的影响，因而在实际使用中其额定 电流值可与一般地区相同；",{"key":24,"text":42,"correct":26},"对安装在海拔高度超过2000m地区的电器外绝缘一般应予加强；",{"key":28,"text":44,"correct":26},"在海拔3000m以下地区，IlOkV及以下配电装置也可以选用性能优良的避雷器来保 护一般电器的外绝缘；",{"key":31,"text":46,"correct":26},"由于现有IlOkV及以下大多数电器的外绝缘有一定裕度，故可使用在海拔2000m以 下的地区。","ABCD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},1034941,"选择电器时关于防震要求的阐述正确的是（ ）。",[52,54,56,58],{"key":20,"text":53,"correct":26},"选择电器时，应根据当地的地震烈度选用能够满足地震要求的产品；",{"key":24,"text":55,"correct":26},"地震基本烈度为7度及以下地区的电器可不另采取防震措施；",{"key":28,"text":57,"correct":22},"在地震烈度为8度以上地区，电器应能承受相应地震烈度的地震力，在安装时，应 考虑支架对地震力的放大作用；",{"key":31,"text":59,"correct":26},"电器的辅助设备应具有与主设备相同的抗震能力。","ABD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":69,"analysis":34},1034944,"在技术选择时需要考虑关合性能的高压设备有（ ）。 A.高压断路器； B.高压负荷开关；C。高压隔离开关；D.高压熔断器。",[65,66,67,68],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},"AB",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":82,"analysis":34},1034947,"关于高压熔断器的使用条件，下列说法正确的有（）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"限流式高压熔断器保护电器可不校验动稳定和热稳定；",{"key":24,"text":77,"correct":22},"限流式高压熔断器可以使用在工作电压低于其额定电压的电网中；",{"key":28,"text":79,"correct":26},"高压熔断器熔管的颏定电流应大于或等于熔体的额定电流；",{"key":31,"text":81,"correct":22},"保护电压互感器的熔断器，需要按额定电压和断流容量选择，还应校验额定电流.","AC",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":95,"analysis":34},1034949,"对主设备选择的一般原则，正确的有（ ）。",[87,89,91,93],{"key":20,"text":88,"correct":26},"应力求技术先进，安全适用，经济合理；",{"key":24,"text":90,"correct":26},"应满足正常运行、检修、短路和过电压情况下的要求，并考虑远景发展；",{"key":28,"text":92,"correct":26},"应按当地坏境条件校核；",{"key":31,"text":94,"correct":22},"应选用新产品。","ABC",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":82,"analysis":34},1034952,"选择户内高压断路器时，必须校验的环境条件有（ ）。",[100,102,104,106],{"key":20,"text":101,"correct":26},"海拔高度；",{"key":24,"text":103,"correct":22},"日温差；",{"key":28,"text":105,"correct":26},"相对湿度；",{"key":31,"text":107,"correct":22},"污秽。",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":82,"analysis":34},1034955,"图7-1所示电压互感器的接线中，不能供电给绝缘检查电压表的是（ ）。",[112,113,114,115],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":33,"analysis":34},1034957,"在海拔高于IOOOm但低于3000m的地区，以下关于IlOkV及以下配电装置电器设 备选择的说法正确的是（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":22},"不能选用一般电器产品；",{"key":24,"text":123,"correct":26},"可以选用相同电压等级的高原型电器产品；",{"key":28,"text":125,"correct":26},"C-可以选用相同电压等级但外绝缘提高一级的电器产品；",{"key":31,"text":127,"correct":26},"可以选用一般电器产品，但应用性能优良的避雷器来保护。",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":140,"analysis":34},1034960,"用于6~IOkV回路的负荷开关与熔断器组合使用时，要求加装分励脱扣器的条件 是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":26},"用于800kVA及以上的油浸变压器回路时；",{"key":24,"text":135,"correct":22},"用于400kVA及以上的干式变压器回路时；",{"key":28,"text":137,"correct":26},"当干式变压器设置超溫跳闸保护时；",{"key":31,"text":139,"correct":26},"当带外壳干式变压器设置误带电开门跳闸保护时.","ACD",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":47,"analysis":34},1034962,"在技术经济合理时，全封闭组合电器宜用于110kV及以上电网的（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":26},"大城市中心变电所；",{"key":24,"text":148,"correct":26},"布置场所特别狭窄的水电厂；",{"key":28,"text":150,"correct":26},"地下变电所；",{"key":31,"text":152,"correct":26},"重污秽地区。",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":95,"analysis":34},1034965,"保护35kV及以下电力变压器的高压熔断器熔体，在（）情况下不应误熔断。",[157,159,161,163],{"key":20,"text":158,"correct":26},"当熔体内通过电力变压器回路最大工作电流时；",{"key":24,"text":160,"correct":26},"当熔体内通过电力变压器的励磁涌流时；",{"key":28,"text":162,"correct":26},"当熔体内通过保护范围以外的短路电流时；",{"key":31,"text":164,"correct":22},"当熔体内通过电力变压器低压側出口的单相接地短路电流时。",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":47,"analysis":34},1034968,"以下关于主变压器冷却方式的说法，正确的是（ ）.",[169,171,173,175],{"key":20,"text":170,"correct":26},"小容量变压器一般采用自然冷却；",{"key":24,"text":172,"correct":26},"强迫导向油循环风冷却方式与强迫油循环水冷却方式相比具有更高的冷却效率；",{"key":28,"text":174,"correct":26},"自然油循环风冷却方式的代号是ONAF;",{"key":31,"text":176,"correct":26},"强迫油循环风冷却系统应采用两路独立电源供电，并能实现自投。",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":189,"analysis":34},1034971,"以下关于断路器额定值的说法，正确的是（ ）。",[181,183,185,187],{"key":20,"text":182,"correct":22},"额定短路开断电流由交流分量有效值和直流分量绝对值两个值来表征；",{"key":24,"text":184,"correct":22},"用于500kV配电装置的高压断路器，其额定橾作顺序应选择O-0.3s~CO~ 180s—CO；",{"key":28,"text":186,"correct":26},"额定峰值耐受电流等于额定短路关合电流；",{"key":31,"text":188,"correct":26},"额定短时耐受电流等于额定短路开断电流。","CD",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":69,"analysis":34},1034973,"关于电流互感器的配置，以下说法正确的有（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":26},"对中性点非有效接地系统，电流互感器可按两相或三相配置；",{"key":24,"text":197,"correct":26},"一个厂站内的电流互感器额定二次电流允许同时采用IA和5A;",{"key":28,"text":199,"correct":22},"一组电流互感器一般具有多个二次绕组，各个二次绕组的变比应相同；",{"key":31,"text":201,"correct":22},"测量用电流互感器必须规定仪表保安系数（FS)，以避免故障时一次回路短时通过 大短路电流而损坏测量仪表。",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":20,"analysis":34},1034976,"已知某1OkV系统为非有效接地系统，系统中一变电站引出的1OkV电缆线路总长度 为30km。求系统有关参数。 长时间中性点位移电压不应超过系统相电压的（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"15%;",{"key":24,"text":209,"correct":22},"20%；",{"key":28,"text":211,"correct":22},"25%；",{"key":31,"text":213,"correct":22},"30%,",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":34},1034978,"已知某1OkV系统为非有效接地系统，系统中一变电站引出的1OkV电缆线路总长度 为30km。求系统有关参数。",[218,219,220,221],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":34},1034981,"中性点非直接接地系统中35\u002F10kV变电所，选择变压器中性点的阀型避雷器的 参数。 灭弧电压应大于（ ）。",[226,228,230,232],{"key":20,"text":227,"correct":26},"25kV；",{"key":24,"text":229,"correct":22},"30kV;",{"key":28,"text":231,"correct":22},"35kV；",{"key":31,"text":233,"correct":22},"37kV。",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":28,"analysis":34},1034984,"中性点非直接接地系统中35\u002F10kV变电所，选择变压器中性点的阀型避雷器的 参数。",[238,239,240,241],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":28,"analysis":34},1034987,"中性点非直接接地系统中35\u002F10kV变电所，选择变压器中性点的阀型避雷器的 参数。 工频放电电压上限（变压器内绝缘一分钟工频试验电压58kV)小于（ ）。",[246,248,250,252],{"key":20,"text":247,"correct":22},"60kV；",{"key":24,"text":249,"correct":22},"62kV,",{"key":28,"text":251,"correct":26},"67kV；",{"key":31,"text":253,"correct":22},"70kV。",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":24,"analysis":34},1034990,"中性点非直接接地系统中35\u002F10kV变电所，选择变压器中性点的阀型避雷器的 参数。 5kV时的残压（变压器内绝缘冲击试验电压91kV)小于（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":22},"79kV;",{"key":24,"text":261,"correct":26},"83kV；",{"key":28,"text":263,"correct":22},"85kV；",{"key":31,"text":265,"correct":22},"87kV。",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":20,"analysis":34},1034993,"110\u002F1OkV中性点直接接地系统中，选择变电所变压器中性点的阀型避雷器的参数。 灭弧电压大于（ ）。",[270,272,274,275],{"key":20,"text":271,"correct":26},"70. 5kV；",{"key":24,"text":273,"correct":22},"78kV;",{"key":28,"text":261,"correct":22},{"key":31,"text":276,"correct":22},"85kV。",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":24,"analysis":34},1034995,"110\u002F1OkV中性点直接接地系统中，选择变电所变压器中性点的阀型避雷器的参数。 工频放电电压下限大于（ ）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"100kV；",{"key":24,"text":284,"correct":26},"140kV；",{"key":28,"text":286,"correct":22},"160kV,",{"key":31,"text":288,"correct":22},"180kV,",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":24,"analysis":34},1034998,"110\u002F1OkV中性点直接接地系统中，选择变电所变压器中性点的阀型避雷器的参数。 工频放电电压上限（变压器内绝缘一分钟工频试验电压150kV)小于（ ）.",[293,295,297,299],{"key":20,"text":294,"correct":22},"162kV；",{"key":24,"text":296,"correct":26},"173kV；",{"key":28,"text":298,"correct":22},"178kV;",{"key":31,"text":300,"correct":22},"182kV。",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":31,"analysis":34},1035000,"110\u002F1OkV中性点直接接地系统中，选择变电所变压器中性点的阀型避雷器的参数。 5kA时的残压（变压器内绝缘冲击试验电压250kV)小于（ )。",[305,307,309,311],{"key":20,"text":306,"correct":22},"180kV;",{"key":24,"text":308,"correct":22},"195kV；",{"key":28,"text":310,"correct":22},"210kV;",{"key":31,"text":312,"correct":26},"227kV。",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":34},1035003,"电抗器电抗百分值为（）.",[317,319,321,323],{"key":20,"text":318,"correct":22},"2%；",{"key":24,"text":320,"correct":26},"3%；",{"key":28,"text":322,"correct":22},"4%；",{"key":31,"text":324,"correct":22},"5%。",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":28,"analysis":34},1035006,"电抗器电压损失为（ ）。",[329,331,333,335],{"key":20,"text":330,"correct":22},"1.35%；",{"key":24,"text":332,"correct":22},"1.40%,",{"key":28,"text":334,"correct":26},"1.44%",{"key":31,"text":336,"correct":22},"1.48%.",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":31,"analysis":34},1035009,"短路时母线剩余电压为（ ）。",[341,343,345,347],{"key":20,"text":342,"correct":22},"50%；",{"key":24,"text":344,"correct":22},"55%；",{"key":28,"text":346,"correct":22},"65%；",{"key":31,"text":348,"correct":26},"75%.",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":351,"answer":20,"analysis":34},1035012,[352,353,354,355],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":358,"answer":31,"analysis":34},1035014,[359,360,361,362],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":24,"analysis":34},1035017,"校验电流互感器动稳定倍数（电流互感器允许动稳定倍数150〉为（ ）.",[367,369,371,373],{"key":20,"text":368,"correct":22},"100；",{"key":24,"text":370,"correct":26},"120；",{"key":28,"text":372,"correct":22},"150；",{"key":31,"text":374,"correct":22},"180。",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":28,"analysis":34},1035020,"校验电流互感器（瓷绝缘）的外部受力（相向距离a为35cm,计箅长度L为 80cm)为（）。",[379,381,383,385],{"key":20,"text":380,"correct":22},"950N；",{"key":24,"text":382,"correct":22},"1000N;",{"key":28,"text":384,"correct":26},"1050N;",{"key":31,"text":386,"correct":22},"1100N。",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":389,"answer":24,"analysis":34},1035022,[390,391,392,393],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":396,"answer":28,"analysis":34},1035025,[397,398,399,400],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":28,"analysis":34},1035028,"请根据有关规程和设计手册对35kV配电装置悬式绝缘子和穿墙套管进行选择和 校验。",[405,406,407,408],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":411,"answer":28,"analysis":34},1035031,[412,413,414,415],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":418,"answer":31,"analysis":34},1035034,[419,420,421,422],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":425,"answer":24,"analysis":34},1035036,[426,427,428,429],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":432,"answer":28,"analysis":34},1035038,[433,434,435,436],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":439,"answer":20,"analysis":34},1035041,[440,441,442,443],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":31,"analysis":34},1035044,"已知某1OkV系统为非有效接地系统，系统中一变电站引出的1OkV电缆线路总长度 为30km。求系统有关参数。 电缆线路的电容电流为（）。",[448,450,452,454],{"key":20,"text":449,"correct":22},"10A;",{"key":24,"text":451,"correct":22},"15A；",{"key":28,"text":453,"correct":22},"20A；",{"key":31,"text":455,"correct":26},"30",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":28,"analysis":34},1035047,"电抗器额定电流为（ ）。",[460,462,464,466],{"key":20,"text":461,"correct":22},"800A；",{"key":24,"text":463,"correct":22},"900A;",{"key":28,"text":465,"correct":26},"1000A；",{"key":31,"text":467,"correct":22},"1500",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":28,"analysis":34},1035050,"已知某1OkV系统为非有效接地系统，系统中一变电站引出的1OkV电缆线路总长度 为30km。求系统有关参数。 消弧线圈补偿容量为（ ）。",[472,474,476,478],{"key":20,"text":473,"correct":22},"200kVA；",{"key":24,"text":475,"correct":22},"230kVA；",{"key":28,"text":477,"correct":26},"270kVA；",{"key":31,"text":479,"correct":22},"300kV",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":24,"analysis":34},1035053,"已知某1OkV系统为非有效接地系统，系统中一变电站引出的1OkV电缆线路总长度 为30km。求系统有关参数。 变电所1OkV配电装置所增加的电容电流为（ ）.",[484,486,488,490],{"key":20,"text":485,"correct":22},"3. 2A；",{"key":24,"text":487,"correct":26},"4. 8A；",{"key":28,"text":489,"correct":22},"6. 4A；",{"key":31,"text":491,"correct":22},"8",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":95,"analysis":34},1035056,"低压电器的选择应符合（）要求。",[496,498,500,502],{"key":20,"text":497,"correct":26},"电器的額定电压不应小于回路的标称电压；",{"key":24,"text":499,"correct":26},"电器的额定电流不应小于所在回路的计算电流；",{"key":28,"text":501,"correct":26},"电器均应适应所在场所的环境条件；",{"key":31,"text":503,"correct":22},"电器均应满足短路条件下的通断能力。",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":516,"analysis":34},1035059,"低压短路保护电器的选择应满足（ ）要求。",[508,510,512,514],{"key":20,"text":509,"correct":26},"保护电器的额定电流不应小于回路的计算电流；",{"key":24,"text":511,"correct":22},"保护电器的额定电流不应小于回路计算电流的1.1倍；",{"key":28,"text":513,"correct":22},"保护电器的额定电流不应小于因路预期短路电流；",{"key":31,"text":515,"correct":26},"保护电器的额定短路合断电流不应小于回路预期短路电流。","AD",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":47,"analysis":34},1035061,"应装设隔离电器的低压回路有（）。 A.维修、测试需要断开电源者； B.配电变压器低压侧； C.建筑物低压线路进线； D配电箱进线。",[521,522,523,524],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":95,"analysis":34},1035063,"隔离电器可采用（ ）。",[529,531,533,535],{"key":20,"text":530,"correct":26},"隔离开关；",{"key":24,"text":532,"correct":26},"插头与插座；",{"key":28,"text":534,"correct":26},"熔断器；",{"key":31,"text":536,"correct":22},"所有断路器。",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":60,"analysis":34},1035066,"通断电流的功能电器（操作电器〉可采用（ ）。",[541,543,545,546],{"key":20,"text":542,"correct":26},"开关；",{"key":24,"text":544,"correct":26},"断路器；",{"key":28,"text":534,"correct":22},{"key":31,"text":547,"correct":26},"接触器，",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":516,"analysis":34},1035069,"宜采用四极开关电器的是（ ）。",[552,554,556,558],{"key":20,"text":553,"correct":26},"TT系统电源进线处；",{"key":24,"text":555,"correct":22},"TN—S、TN~C — S系统变压器低压总开关；",{"key":28,"text":557,"correct":22},"TN—S、TN—C—S系统变电所内低压母联开关;",{"key":31,"text":559,"correct":26},"TN、TT系统与IT系统之间的电源转换开关。",[561,565,568,571,574,577],{"id":562,"name":563,"category":7,"favorite":564},1,"领导干部任职前廉政法规知识测试题",92,{"id":566,"name":567,"category":7,"favorite":562},595,"建筑结构与设备",{"id":569,"name":570,"category":7,"favorite":562},715,"招标采购专业知识与法律法规",{"id":572,"name":573,"category":7,"favorite":562},848,"市政方向-通用基础",{"id":575,"name":576,"category":7,"favorite":8},534,"BIM工程师",{"id":578,"name":576,"category":7,"favorite":8},535]