[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-34":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":581},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,34,50,2321,[13,35,47,58,71,84,92,105,118,130,142,154,166,175,187,199,212,221,229,241,253,261,273,285,293,306,314,322,334,346,358,370,378,386,398,409,421,432,444,456,468,480,492,500,508,520,532,544,556,569],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1034668,2,"多选题","电缆夹层的净空高度不得小于（ ），但不宜大于（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1800mm；",false,{"key":24,"text":25,"correct":26},"B","2000mm；",true,{"key":28,"text":29,"correct":22},"C","2600mm；",{"key":31,"text":32,"correct":26},"D","3000mm,","BD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":33,"analysis":34},1034671,"3~llOkV屋外配电装置的安全净距中，A值的适用范围为（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":22},"不同相的带电部分之间；",{"key":24,"text":42,"correct":26},"带电部分至接地部分之间；",{"key":28,"text":44,"correct":22},"断路器和隔离开关的断口两侧引线带电部分之间；",{"key":31,"text":46,"correct":26},"网状遮栏向上延伸线距地2. 5m处与遮栏上方带电部分之间.",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":57,"analysis":34},1034673,"3~llOkV屋内配电装置的安全净距中，A2值的适用范围为（ ）.",[51,52,53,55],{"key":20,"text":42,"correct":22},{"key":24,"text":40,"correct":26},{"key":28,"text":54,"correct":26},"C断路器和隔离开关的断口两側带电部分之间",{"key":31,"text":56,"correct":22},"无遮拦棵导体至地面之间。","BC",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":70,"analysis":34},1034676,"污秽地区的3~llOkV配电装置的设计要考虑污闪问题，下列适宜的防污闪措施有 ( ).",[62,64,66,68],{"key":20,"text":63,"correct":26},"尽量远离污染",{"key":24,"text":65,"correct":26},"合理选择配电装置型式，如屋内式或全封闭组合电器（GIS);",{"key":28,"text":67,"correct":26},"增大电瓷外絶缘的有效泄漏距离或选用防污型产品；",{"key":31,"text":69,"correct":26},"加强运行维护，定期停电清扫；在重污染地区应考虑带电水冲洗。","ABCD",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":83,"analysis":34},1034678,"根据规范的规定，安装在室内的lOkV装配式高压电容器组，下层电容器的底部距 地面应不小于0.2m,上层电容器的底部距地面不宜大于2. 5m,电容器布置不宜超过三层。 其理由是（ )。",[75,77,79,81],{"key":20,"text":76,"correct":26},"下层电容器底部距地距离是考虑电容器的通风散热；",{"key":24,"text":78,"correct":26},"上层电容器底部距地距离是为了便于电容器的安装、巡视和搬运检修；",{"key":28,"text":80,"correct":26},"为便于接线，三层布置是目前单相电容器在室内的常用布置形式；",{"key":31,"text":82,"correct":22},"为了布置整齐、美观好看。","ABC",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":70,"analysis":34},1034681,"变电所屋外配电装置的位置，应尽量远离污染源，并且应使配电装置在潮湿季节处 于污染源的上风向。屋外配电装置与各类污染源之间的最小距离应满足要求：与制铝厂为 ( )；与化工厂和一般厂为（）；与水泥厂为（ ）；与化工厂和冶金厂为（ ）。 A. 0. 5km5 B. 2km； C 0. 8km; D. 1. 5km。",[88,89,90,91],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":104,"analysis":34},1034684,"下列（ ）通常称之为变电所。",[96,98,100,102],{"key":20,"text":97,"correct":26},"所有设有变压比为11、单台容量为63000kVA变压器的；",{"key":24,"text":99,"correct":26},"B所有设有变压比为25、单台容量为1250kVA2台变压器的；",{"key":28,"text":101,"correct":22},"C所内只有起开闭和分配电能作用的高压配电装置的；",{"key":31,"text":103,"correct":26},"所内3台变压器放置于露天的。","ABD",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":117,"analysis":34},1034687,"为了安全，并满足安装、检修的必要空间，设置于变电所内的非封闭式干式变压器 应采取相应措施。下列措施正确的是（ )。",[109,111,113,115],{"key":20,"text":110,"correct":26},"在变压器的周围应装设高度不低于1.7m的固定遮栏；",{"key":24,"text":112,"correct":22},"固定遮栏网孔的大小大于50mmX50mm;",{"key":28,"text":114,"correct":26},"两台变压器之间的净距应不小于1.0m;",{"key":31,"text":116,"correct":26},"变压器外廓与遮栏的净距不宜小于0.6m,","ACD",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":70,"analysis":34},1034689,"可燃油油浸电力变压器室的门在下列（）情况之一时，应为甲级防火门.",[122,124,126,128],{"key":20,"text":123,"correct":26},"变压器室位于车间内或建筑物内；",{"key":24,"text":125,"correct":26},"变压器室位于容易沉积可燃粉尘、可燃纤維的场所；",{"key":28,"text":127,"correct":26},"变压器室附近有粮、棉花及可燃物大量集中的露天堆场；",{"key":31,"text":129,"correct":26},"变压器室下面有地下室。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":33,"analysis":34},1034692,"在采暖地区（但该地区的配电室内温度不致影响电气设备元件和仪表的正常运行）， 有人值班的变电所的（）应设采暖装置。",[134,136,138,140],{"key":20,"text":135,"correct":22},"高压配电室；",{"key":24,"text":137,"correct":26},"值班室；",{"key":28,"text":139,"correct":22},"低压配电室；",{"key":31,"text":141,"correct":26},"控制室.",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":117,"analysis":34},1034695,"IOkV及以下变电所中，室内变电所是（ ）的总称。",[146,148,150,152],{"key":20,"text":147,"correct":26},"附设变电所；",{"key":24,"text":149,"correct":22},"配电所；",{"key":28,"text":151,"correct":26},"独立变电所；",{"key":31,"text":153,"correct":26},"车间内变电所。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":33,"analysis":34},1034697,"电缆隧道每隔不大于（ ）距离应设安全孔（人孔），安全孔距电缆隧道的首末 端不宜超过（ )。",[158,160,162,164],{"key":20,"text":159,"correct":22},"50m；",{"key":24,"text":161,"correct":26},"75m；",{"key":28,"text":163,"correct":22},"lOm",{"key":31,"text":165,"correct":26},"5m;",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":174,"analysis":34},1034700,"11OkV屋内外配电装置中，不同相的带电部分之间的安全净距与带电部分至接地部 分之间的安全净距( ),且不同相的带电部分之间的安全净距（ ）带电部分至接地 部分之间的安全净距。 A.不相等； B.相等； C大于； D.小于。",[170,171,172,173],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},"AC",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":70,"analysis":34},1034703,"1lOkV及以下屋内高压配电装置中，同一电压等级的A (A1、A2)值较屋外的A (A1、A2)小，间隙裕度少，这主要是考虑（ ）等因素。",[179,181,183,185],{"key":20,"text":180,"correct":26},"屋内导线不受风吹偏斜的影响；",{"key":24,"text":182,"correct":26},"B屋内环境和大气条件较屋外有利 .",{"key":28,"text":184,"correct":26},"屋内带电体位置固定；",{"key":31,"text":186,"correct":26},"屋内间隙裕度大影响造价.",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":174,"analysis":34},1034706,"63kV及以下的屋外高压配电装置中，同一电压等级的A1 ( ) A2值，且 ( )屋内配电装置的A,、A2值。",[191,193,195,197],{"key":20,"text":192,"correct":26},"等于；",{"key":24,"text":194,"correct":22},"不等于；",{"key":28,"text":196,"correct":26},"大于；",{"key":31,"text":198,"correct":22},"小于。",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":211,"analysis":34},1034709,"在3~1lOkV高压配电装置安全净距的规定中，当为网状遮栏时，B2=A1+30mm +70mm,其中30mm是考虑（ ），70mm是考虑（ ）。",[203,205,207,209],{"key":20,"text":204,"correct":26},"施工误差;",{"key":24,"text":206,"correct":22},"施工工具的长度；",{"key":28,"text":208,"correct":22},"維护工具的长度；",{"key":31,"text":210,"correct":26},"一般运行人员手指误入网状遮栏时手指长不大于该值。","AD",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":220,"analysis":34},1034712,"屋内配电装置的设计应考虑电气设备搬运的方便，当需在楼板上设撖运孔时，搬运孔的尺寸一般按设备外形加（ ）考虑，搬运设备通道的宽度一般按最大设备的宽度加 ()考虑，搬运电抗器的搬运孔一般按电抗器外形尺寸加（）考虑。 A. 0. lm； B0.3m; C.O. 4m; D. 0. 5m。",[216,217,218,219],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},"BCD",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":33,"analysis":34},1034714,"在非积雪严重地区，3~IlOkV屋外配电装置安全净距的规定中，C=A1+2300mm+ 200mm,其中2300mm是考虑（ ）不超过此值，200mm是考虑（ ）* A.人站在载重汽车车厢中举手高度； B. 一般运行人员举手后总髙度； C屋内配电装置施工误差； D.屋外配电装置施工误差。",[225,226,227,228],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":174,"analysis":34},1034717,"在3~IlOkV屋外配电装置安全净距的规定中，D =A1 +1800mm+200mm,其中 1800mm是考虑（ ),200mm是考虑（ ）。",[233,235,237,239],{"key":20,"text":234,"correct":26},"一般检修人员和工具的活动范围不超过此值；",{"key":24,"text":236,"correct":22},"B一般检修人员举手后总髙度不超过此值；",{"key":28,"text":238,"correct":26},"C屋外条件较差，宜増加裕度；",{"key":31,"text":240,"correct":22},"屋内条件虽好，也需增加裕度。",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":33,"analysis":34},1034720,"安装3~35kV成套配电装置的电气室净空髙度，一般按下列原则确定：①对于3~ IOkV电气室，其净空髙度为（ ）；②对于35kV电气室，其净空高度为（ ）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"配电装置高度+0. 1mm;",{"key":24,"text":248,"correct":26},"配电装置高度+0.5m;",{"key":28,"text":250,"correct":22},"配电装置高度+0. 7mm;",{"key":31,"text":252,"correct":26},"配电装置高度+0.9m。",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":211,"analysis":34},1034723,"干式空心串联电抗器组装的零部件，宜采用（）连接，当采用矩形母线与相邻 设备连接时，矩形母线应（ ）。 A.不诱钢螺栓； B铁质螺栓； C.平放； D.立放；",[257,258,259,260],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":57,"analysis":34},1034725,"干式空心串联电抗器的支承绝缘子接地，应采用放射形或（ ),并应与主接地 网至少有（ ）连接。",[265,267,269,271],{"key":20,"text":266,"correct":22},"闭口环形；",{"key":24,"text":268,"correct":26},"开口环形；",{"key":28,"text":270,"correct":26},"两点；",{"key":31,"text":272,"correct":22},"—点。",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":70,"analysis":34},1034728,"低压配电屏成排布置时，通常的布置形式有（ ）。",[277,279,281,283],{"key":20,"text":278,"correct":26},"单排布置；",{"key":24,"text":280,"correct":26},"双排面对面布置；",{"key":28,"text":282,"correct":26},"C双棑背对背布置；",{"key":31,"text":284,"correct":26},"多排同向布里.",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":220,"analysis":34},1034731,"在（ ）中，可燃油油量为1OOOkg及以上的变压器，应设置容量为100%油量的 挡油设施。 A.配电所； B附设变电所； C.露天变电所； D.半露天变电所",[289,290,291,292],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":305,"analysis":34},1034733,"在变电所的设计中，通常需根据不同的情况设置贮油池或挡油设施，下列关于贮油 池或挡油设施的叙述正确全面的有（ ）。",[297,299,301,303],{"key":20,"text":298,"correct":22},"贮存油的池子;",{"key":24,"text":300,"correct":22},"挡住油不致外流的设施；",{"key":28,"text":302,"correct":26},"C油流入后不致被外部已燃烧的物质延燃的设施；",{"key":31,"text":304,"correct":26},"D使燃烧的油不致外溢的设施。","CD",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":305,"analysis":34},1034736,"柴油发电机房应采用耐火极限时间不低于（ ）的隔墙和（ ）的楼板与其他 部位隔开。 A. l.Oh； B 1. 2h C. 1.5h； D. 2. Oh。",[310,311,312,313],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":33,"analysis":34},1034739,"柴油发电机房应有（）出口，门应采取防火、隔音措施，并应（ ）开启。 A. 一个; B两个； C.向左; D.向外.",[318,319,320,321],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":117,"analysis":34},1034742,"1OkV及以下变电所所址选择应经济技术比较确定。按下列（ ）要求选择其所 址是适宜的。",[326,328,330,332],{"key":20,"text":327,"correct":26},"接近负荷中心；",{"key":24,"text":329,"correct":22},"不宜设在多尘或有腐蚀性气体的场所，当无法远离时，可以设在污染源盛行风向的 下风侧；",{"key":28,"text":331,"correct":26},"不应设在地势低洼和可能积水的场所；",{"key":31,"text":333,"correct":26},"装有可燃性油浸变压器的车间变电所，不应设在三、四级耐火等级的建筑物内，当 设在二级耐火等级的建筑物内时，建筑物应采取局部措施。",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":70,"analysis":34},1034744,"35~IlOkV变电所所址选择，应根据下列（ ）要求，综合考虑确定。",[338,340,342,344],{"key":20,"text":339,"correct":26},"靠近负荷中心；",{"key":24,"text":341,"correct":26},"节约用地，不占或少占耕地及经济效益高的土地；",{"key":28,"text":343,"correct":26},"周围环境宜无明显污秽，如空气污秽时，宜设在受污源影响最小处；",{"key":31,"text":345,"correct":26},"与城乡或工矿企业规划相协调，便于架空和电缆线路的引入和引出。",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":70,"analysis":34},1034747,"1OkV及以下的露天或半露天变电所，不应设置在（ ）。",[350,352,354,356],{"key":20,"text":351,"correct":26},"有腐蚀性气体的场所；",{"key":24,"text":353,"correct":26},"挑檐为燃烧体或难燃体和耐火等级为四级的建筑物旁；",{"key":28,"text":355,"correct":26},"附近有棉、粮及其他易燃、易爆物品集中的露天堆场；",{"key":31,"text":357,"correct":26},"容易沉积可燃粉尘、可燃纤维、灰尘或导电尘埃且严重影响变压器安全运行的场所。",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":70,"analysis":34},1034749,"变电所的型式应根据用电负荷的状况和周围环境情况确定，下列型式变电所的设置 符合规定的有（ ）。 A.负荷小而分散的工业企业和大中城市的居民区宜设独立变电所，有条件时也可设附 设变电所或户外箱式变电站;",[362,364,366,368],{"key":20,"text":363,"correct":26},"B高层或大型民用建筑内，宜设室内变电所或组合式成套变电站;环境允许的中小城 镇居民区和工厂的生活区，当变压器容量在315kVA及以下时，宜设杆上式或高台式变",{"key":24,"text":365,"correct":26},"电所；",{"key":28,"text":367,"correct":26},"负荷较大的多跨厂房，负荷中心在厂房的中部且环境许可时，宜设车间内变电所或 组合式成套变电站；",{"key":31,"text":369,"correct":26},"负荷较大的车间和站房，宜设附设变电所或半露天变电所。",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":211,"analysis":34},1034752,"工业企业总变电所一般为（ ），高电压深人负荷中心的车间变电所一般 为（）* A.独立式布置；B本地下布置； C.地下布置； D.附设式布置.",[374,375,376,377],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":57,"analysis":34},1034755,"11OkV配电装置一般采用（ ），对位于污秽地区以及用地受到限制地区的配电 装置，应采用（ ）.1lOkVGIS装置可用屋内式布置。 A.高型布置； B屋外式; C屋内式； D.低型布置.",[382,383,384,385],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":211,"analysis":34},1034758,"一次电压为35~1lOkV的电力变压器一般布置在（ ），在空气恃别污秽地区, 变压器外绝缘应按污秽等级加强，也可布置在（ ）.",[390,392,394,396],{"key":20,"text":391,"correct":26},"屋外；",{"key":24,"text":393,"correct":22},"半地下；",{"key":28,"text":395,"correct":22},"地下；",{"key":31,"text":397,"correct":26},"屋内.",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":305,"analysis":34},1034761,"—个110\u002F10kV变电所，llOkV、IOkV配电装置及主变压器均布置在屋内，变电所 总体平面布置如图5-1所示，该布置一般适用于（ ）。",[402,403,405,407],{"key":20,"text":34,"correct":22},{"key":24,"text":404,"correct":22},"炎热地区； B严寒地区；",{"key":28,"text":406,"correct":26},"用地受限制；",{"key":31,"text":408,"correct":26},"环境污秽地区。",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":83,"analysis":34},1034763,"—个35\u002F10kV变电所，35kV、IOkV配电装置及主变压器均布置在屋内，配电装置 室为双层结构，35kV配电装置布置在二层，1OkV配电装置布置在一层。变电所总体平面 布置如图5-2所示。该布置一般适用于（ ）。",[413,415,417,419],{"key":20,"text":414,"correct":26},"两级电压的企业总变电所；",{"key":24,"text":416,"correct":26},"两级电压的车间变电所；",{"key":28,"text":418,"correct":26},"环境污秽地区；",{"key":31,"text":420,"correct":22},"高海拔地区。",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":83,"analysis":34},1034766,"—个llOkV、IOkV变电所，llOkV、IOkV配电装置及主变压器均为屋内式布置， 控制楼为三层结构，独立布置。变电所总体平面布置如图5-3所示。该布置一般适用 于（ ）。",[425,427,429,431],{"key":20,"text":426,"correct":26},"1lOkV配电装置采用SFs全封闭组合电器；",{"key":24,"text":428,"correct":26},"两种电压等级的企业总变电所；",{"key":28,"text":430,"correct":26},"处于2级及以上污秽地区；",{"key":31,"text":420,"correct":22},{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":70,"analysis":34},1034768,"—个110\u002F35\u002F10kV变电所，1lOkV配电装置及主变压器屋外布置，35kV、IOkV配 电装置均为屋内布置，35kV布置在上层、1OkV布置在下层。变电所总体平面布置如图5-4 所示。该布置一般适用于（）。",[436,438,440,442],{"key":20,"text":437,"correct":26},"三种电压等级的企业总变电所；",{"key":24,"text":439,"correct":26},"B用地不受限制；",{"key":28,"text":441,"correct":26},"环境无污秽地区；",{"key":31,"text":443,"correct":26},"三种电压等级的独立变电所。",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":104,"analysis":34},1034771,"高压网络短路电流近似计箅时的计箅条件，下列说法（ )是正确的。",[448,450,452,454],{"key":20,"text":449,"correct":26},"所有电源的电动势相位角相同;",{"key":24,"text":451,"correct":26},"各元件的感抗为一常数；",{"key":28,"text":453,"correct":22},"电路中总电阻小于总电抗Xs的1\u002F3时，应计入有效电阻；",{"key":31,"text":455,"correct":26},"电路电容和变压器励磁电流略去不计。",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":117,"analysis":34},1034774,"低压网络短路电流近似计箅时的计箅条件，下列说法（ ）是正确的.",[460,462,464,466],{"key":20,"text":461,"correct":26},"要计入短路电路各元件的有效电阻；",{"key":24,"text":463,"correct":22},"要计入导线连接点的接触电阻；",{"key":28,"text":465,"correct":26},"可忽略短路点的电弧电阻；",{"key":31,"text":467,"correct":26},"一般情况可按无限大电源容量的网络进行计算。",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":83,"analysis":34},1034777,"计算短路电流的目的是（ ）.",[472,474,476,478],{"key":20,"text":473,"correct":26},"正确选择和校验电气设备；",{"key":24,"text":475,"correct":26},"继电保护的选择和整定；",{"key":28,"text":477,"correct":26},"正确选择和校验载流导体；",{"key":31,"text":479,"correct":22},"校验电压互感器的热稳定性。",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":117,"analysis":34},1034780,"无限大容量系统的主要特点是（）。",[484,486,488,490],{"key":20,"text":485,"correct":26},"短路点远离发电机；",{"key":24,"text":487,"correct":22},"电源电抗随时间而变化；",{"key":28,"text":489,"correct":26},"短路电流周期分量在整个过程不衰减；",{"key":31,"text":491,"correct":26},"母线电压在过渡过程中维持恒定。",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":83,"analysis":34},1034782,"有限容量系统的主要特点是（）。 A.电源电抗随时间而变化； B电源电压在过渡过程中不能维持恒定； C.短路电流随电压而变化； D.电源内阻抗可忽略不计.",[496,497,498,499],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":174,"analysis":34},1034785,"三相短路电流当（ ）时I\"=I0.2 = IK。 A.短路点远离发电机； B短路点靠近发电机； C.无限大容量系统； D.有限容量系统。",[504,505,506,507],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":305,"analysis":34},1034787,"关于高压同步电动机对短路电流的影响，以下说法正确的是（ )。",[512,514,516,518],{"key":20,"text":513,"correct":22},"可不考虑；",{"key":24,"text":515,"correct":22},"可按无限大电源容量考虑；",{"key":28,"text":517,"correct":26},"可按有限电源容量考虑；",{"key":31,"text":519,"correct":26},"在过渡过程任一时刻，所给出的短路电流周期分量可利用运算曲线或运算曲线數字 表计算。",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":57,"analysis":34},1034790,"关于高压异步电动机对短路电流的影响，正确的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":22},"在任何接线情况下都要考虑；",{"key":24,"text":527,"correct":26},"在与短路点的连接已相隔一个变压器者可不考虑；",{"key":28,"text":529,"correct":26},"计算不对称短路时可不考虑；",{"key":31,"text":531,"correct":22},"计算对称或不对称短路时都要考虑。",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":104,"analysis":34},1034793,"在计算网络参数时，常需要进行网络简化，以下等值电源可以归并的有（）。",[536,538,540,542],{"key":20,"text":537,"correct":26},"同型式发电机且至短路点的电气距离大致相等；",{"key":24,"text":539,"correct":26},"B不同型式发电机但至短路点的电气距离较远（即X.>1);",{"key":28,"text":541,"correct":22},"同型式或不同型式发电机但至短路点的电气距离较近；",{"key":31,"text":543,"correct":26},"直接接于短路点上的同类型发电机.",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":174,"analysis":34},1034796,"在用标幺值计算短路电流的总阻抗时，下列要求正确的是（ ).",[548,550,552,554],{"key":20,"text":549,"correct":26},"所有阻抗必须换算到同一基准容量下的标幺值；",{"key":24,"text":551,"correct":22},"各电器元件直接用样本上的标幺值；",{"key":28,"text":553,"correct":26},"基准电压用各元件所在级的平均电压；",{"key":31,"text":555,"correct":22},"基准电压用各元件所在级的标称电压。",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":568,"analysis":34},1034798,"在用有名值计箅短路电流总阻抗时，下列要求正确的是（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":26},"把各电压级所在元件阻抗的有名值归算到短路点所在级平均电压下的有名值；",{"key":24,"text":563,"correct":26},"B把各电压级所在元件阻抗的标幺值归算到短路点所在级平均电压下的有名值；",{"key":28,"text":565,"correct":22},"把各电压级所在电器阻抗的标么值归算各自所在级平均电压下的有名值;",{"key":31,"text":567,"correct":22},"把各电压级所在线路阻抗，按线路每千米的阻抗有名值乘以线路的千米数。","AB",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":117,"analysis":34},1034801,"短路电流计箅采用标幺值法时，正确的是（）。",[573,575,577,579],{"key":20,"text":574,"correct":26},"标幺值电流可代替标幺值容量；",{"key":24,"text":576,"correct":22},"B位于不同电压等级的阻抗可用统一的基准电压来计算阻抗的标幺值；",{"key":28,"text":578,"correct":26},"C相电压和线电压的标幺值相同；",{"key":31,"text":580,"correct":26},"单相功率和三相功率的标幺值相同。",[582,586,589,592,595,598],{"id":583,"name":584,"category":7,"favorite":585},1,"领导干部任职前廉政法规知识测试题",92,{"id":587,"name":588,"category":7,"favorite":583},595,"建筑结构与设备",{"id":590,"name":591,"category":7,"favorite":583},715,"招标采购专业知识与法律法规",{"id":593,"name":594,"category":7,"favorite":583},848,"市政方向-通用基础",{"id":596,"name":597,"category":7,"favorite":8},534,"BIM工程师",{"id":599,"name":597,"category":7,"favorite":8},535]