[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-33":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":577},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,33,50,2321,[13,31,44,57,66,78,90,103,116,128,141,149,161,169,181,193,205,217,230,242,254,265,272,284,292,300,313,325,334,346,358,366,378,391,401,413,421,429,441,453,465,477,489,501,511,521,533,545,557,569],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":29,"analysis":30},1034532,2,"多选题","为减小谐波影响而串人电容器组的电抗器的接线位置，以下描述中正确的 是（）。 A.宜接于电容器组的中性点侧； B.可以接于电容器组的电源侧，但应校验短路动热稳定； C不准接于电容器组的电源侧； D.必须接于电容器的中性点侧。",[19,22,24,27],{"key":20,"text":20,"correct":21},"A",true,{"key":23,"text":23,"correct":21},"B",{"key":25,"text":25,"correct":26},"C",false,{"key":28,"text":28,"correct":26},"D","AB","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":43,"analysis":30},1034534,"对电容器组的放电器放电性能的要求，即将电容器放电至剩余电压为50V的时间， GB 5053—1994 第 5.1. 3 条规定为 5min; GB 50227—1995 第 5. 6. 3 条规定为 5sec。合适的 引用态度是（ ）。",[35,37,39,41],{"key":20,"text":36,"correct":21},"手动投切时间取长一些；",{"key":23,"text":38,"correct":21},"频繁投切时间取短一些；",{"key":25,"text":40,"correct":21},"自动投切应与再投入的延时配合；",{"key":28,"text":42,"correct":26},"不加考虑，随意选取。","ABC",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":56,"analysis":30},1034536,"当电容器内带有放电阻时，可否取消外放电器，以下描述中正确的是（ ）。",[48,50,52,54],{"key":20,"text":49,"correct":21},"通常电容器内放电电阻放电速度慢，只能满足手动投切电容器的要求；",{"key":23,"text":51,"correct":26},"B只要电容器带有内放电电阻，无论放电速度能否满足投切要求，都可以取消外放 电器；",{"key":25,"text":53,"correct":21},"C只在确信电容器内放电电阻的放电速度已能满足投切要的条件下，才能不装设外放 电器；",{"key":28,"text":55,"correct":26},"无论有无内放电电阻，也无论投切频繁程度，都要加上外放电器。","AC",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":65,"analysis":30},1034539,"低压电容器组的放电器的正确接线方式是（ ）。 A.中性点接地的星形； B中性点不接的星形； C.三角形，不接地； D. B相接地的三角形。",[61,62,63,64],{"key":20,"text":20,"correct":26},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":26},"BC",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":56,"analysis":30},1034542,"高压电容器组的检修接地开关的设置原则是（ ）",[70,72,74,76],{"key":20,"text":71,"correct":21},"中性点倒宜设置检修接地开关；",{"key":23,"text":73,"correct":26},"中性点侧禁止设置检修接地开关;",{"key":25,"text":75,"correct":21},"电源侧宜设置检修接地开关；",{"key":28,"text":77,"correct":26},"电源侧禁止设置检修接地开关。",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":65,"analysis":30},1034545,"并联电容器装置中，电容器型式选择的原则是（）。",[82,84,86,88],{"key":20,"text":83,"correct":26},"不应选用单台容量在500kvar及以上的电容器；",{"key":23,"text":85,"correct":21},"可选用单台容量在500kvar及以上的电容器；",{"key":25,"text":87,"correct":21},"低压电容器宜采用自愈式电容器；",{"key":28,"text":89,"correct":26},"低压电容器不宜采用自愈式电容器。",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":102,"analysis":30},1034548,"并联电容器装置，如电容器的电容值（微法拉）一定，串人电抗器与不串入电抗 器比较，以下描述中正确的是（ ）。",[94,96,98,100],{"key":20,"text":95,"correct":26},"电容器端子上的工频电压会降低；",{"key":23,"text":97,"correct":21},"电容器端子上的工频电压会升高；",{"key":25,"text":99,"correct":21},"C流入电容器的工頻电流会增加；",{"key":28,"text":101,"correct":21},"流入电容器的谐波电流是增加抑或减小，需视串入电抗器的电抗率的大小、谐波源 所含谐波的次数(频率）以及系统阻抗（含其他补偿装置）的“阻抗一频率”特性而定。","BCD",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":115,"analysis":30},1034551,"高压并联电容器装置断路的选择，除应符合断路器有关标准外，尚应符 合（ ）。",[107,109,111,113],{"key":20,"text":108,"correct":21},"关合时，触头弹跳时间不应大于2ms,且不应有过长的预击穿；10kV少油断路器的 关合预击穿时间不能超过3. 5ms ；",{"key":23,"text":110,"correct":21},"B开断时不应重燃；",{"key":25,"text":112,"correct":21},"应能承受关合涌流，以及工频短路电流和电容器涌流的联合作用；",{"key":28,"text":114,"correct":21},"每天段切超过三次的断路器，应具备频繁操作性。","ABCD",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":56,"analysis":30},1034554,"高压并联电容器装置，采用总回路下带若干分组回路接线，断路器的选型和操作 过电保护的设置原则是（）。",[120,122,124,126],{"key":20,"text":121,"correct":21},"当总回路断路已具备切除短路电流的能力，分组回路断路器可采用不承担开断短路 电流能力的开关设备；",{"key":23,"text":123,"correct":26},"B尽管总回路断路器已具备切除短短电流的能力，分组回路断路器也必须具备切除短 路电流的能力；",{"key":25,"text":125,"correct":21},"分组因路宜设置操作过电压保护；",{"key":28,"text":127,"correct":26},"分组回路不宜设置操作过电压保护。",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":140,"analysis":30},1034556,"保护电容器用熔断器的选择原则，下列叙述中正确的是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":21},"宜采用喷逐式熔断器；",{"key":23,"text":135,"correct":26},"宜采用限流式熔断器；",{"key":25,"text":137,"correct":21},"熔断器的熔丝额定电流不应小于电容器額定电流的1.43倍，并不宜大于电容器額定 电流的1.55倍；",{"key":28,"text":139,"correct":21},"熔断器的电流一时间曲线，应选在被保护电容器外壳的10%爆裂概率曲线的左侧 (安全侧）。","ACD",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":43,"analysis":30},1034558,"10kV及以下配电所进线开关选型的正确原则是（）。 A.非专用电源线（树干式，T接线）进线处应设带保护的断路器； B专用电源线进线处宜设断路器或带熔断器的负荷开关，当无继电保护和自动装置 (如备用自投），且出线回路少又无需带负荷操作时，可采用隔离开关或隔离触头； C.当总配电所与分配电所由同一单位管理、维护，总配电所又以放射式专线对分配电 所供电，该分配电所电源进线处宜采用隔离开关或隔离触头，但如果分配电所需要带负荷操 作或继电保护、自动装置有要求时，应采用断路器； D.不分情况，一律采用隔离开关。",[145,146,147,148],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":26},{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":102,"analysis":30},1034561,"10kV及以下变电所装设两台和两台以上配电变压器的正确条件是（ ）。",[153,155,157,159],{"key":20,"text":154,"correct":26},"全部为三级负荷、容量不大且季节性变化不大",{"key":23,"text":156,"correct":21},"有大量一级或二级负荷；",{"key":25,"text":158,"correct":21},"季节性负荷变化大；",{"key":28,"text":160,"correct":21},"集中负荷较大。",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":29,"analysis":30},1034564,"10kV、6kV固定式配电装置出线断路器线路侧，应该装设隔离开关的条件 是（） A.出线为架空线路； B出线为电缆线路且有反馈可能时； C.出线为电缆线路且无反馈可能时； D.无条件地都应装设。",[165,166,167,168],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":26},{"key":28,"text":28,"correct":26},{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":102,"analysis":30},1034567,"选择35~llOkV变电所主变压器台数的原则，以下叙述中正确的是（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":26},"应不小于两台；",{"key":23,"text":176,"correct":21},"有一、二级负荷时，宜装设两台；",{"key":25,"text":178,"correct":21},"有一、二级负荷，但变电所可由中、低压侧电力网取得足够容量的备用电源时可装 设一台主变压器；",{"key":28,"text":180,"correct":21},"应根据地区供电条件、负荷性质、用电容量和运行方式等条件综合考虑确定。",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":102,"analysis":30},1034570,"确定35~llOkV变电所主接线的正确原则是（ ）",[185,187,189,191],{"key":20,"text":186,"correct":26},"35~llOkV线路为两回及以下时宜采用双母线；",{"key":23,"text":188,"correct":21},"35~llOkV线路为两回及以下时宜采用桥形、线路变压器组或线路分支（即T接） 接线；",{"key":25,"text":190,"correct":21},"35~llOkV线路超过两回时宜采用扩大桥形、单母线或分段单母线的接线",{"key":28,"text":192,"correct":21},"llOkV线路为6回及以上时宜采用双母线，35~63kV线路为8回及以上时亦可采用 双母线.",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":29,"analysis":30},1034573,"35~llOkV变电所主接线中，可增设旁路设施的正确原则是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":21},"单母线、分段单母线或双母线接线，当不允许停电检修断路器时；",{"key":23,"text":200,"correct":21},"当llOkV线路为6回以上，35~63kV线路为8回及以上时，可装设专用旁路断 路器；",{"key":25,"text":202,"correct":26},"采用SF6断路器的主接线时;",{"key":28,"text":204,"correct":26},"采用手车式高压开关拒时。",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":140,"analysis":30},1034574,"35~llOkV变电所的10 (6) kV母接线方式宜采用（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":21},"当有两台主变压器时宜采用分段单母线；",{"key":23,"text":212,"correct":26},"B当有两台主变压器时宜采用不分段的单母线；",{"key":25,"text":214,"correct":21},"线路为12回以上时可采用双母线；",{"key":28,"text":216,"correct":21},"当不允许停电检修断路器时可设置旁路设施，但如10(6) kV配电装置采用手车式 高压开关拒时，不宜设置旁路设施。",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":229,"analysis":30},1034577,"35~llOkV变电所，为检修电压互感器和避雷器而设置隔离开关的正确原则是 ( ).",[221,223,225,227],{"key":20,"text":222,"correct":26},"接在母线上的电压互感器和避雷器，不可合用一组隔离开关；",{"key":23,"text":224,"correct":21},"接在母线上的电压互感器和避雷器，可合一组隔离开关；",{"key":25,"text":226,"correct":26},"接在主变压器引出线上的避雷器，必须设置隔离开关；",{"key":28,"text":228,"correct":21},"接在主变压器⑴出线上的避雷器，不宜设置隔离开关。","BD",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":115,"analysis":30},1034580,"关于桥形（外桥和内桥）接线，以具有两回路电源进线和两台主变压器的变电所 为例，下列说法中正确的是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":21},"以分段单母线为基准，为减少断路器数量和节约建设投资，分别用隔离开关取代进 线断路器或主变压器回路断路器，即构成桥形接钱。原母线分段因路，称为“桥”，桥上仍 设置断路器的，称“断路器桥”，桥上仅设置隔离开关的，称“隔离开关桥”；",{"key":23,"text":237,"correct":21},"用隔离开关取代主变压器回路断路器、进线回路仍保留断路器的，叫内桥。因为当 呈述人站在主变压器处且面对进线，桥位于断路器的内侧（距呈述人较近）；",{"key":25,"text":239,"correct":21},"用隔离开关取代进线断路器、主变压器回路仍保留断路器的，叫外桥。因为当呈述 人站在主变压器处且面对进线，桥位于断路器的外侧（距呈述人较远）；",{"key":28,"text":241,"correct":21},"就供电可靠性和操作方便而言，桥形接线逊色于分断单母线，但能节约投资和减少 断路器数量。",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":56,"analysis":30},1034583,"外桥和内桥相比较，适宜采用内桥接线的条件是()。",[246,248,250,252],{"key":20,"text":247,"correct":21},"电源线路较长，线路故障机会较多；",{"key":23,"text":249,"correct":26},"电源线路较短，线路故障机会较少；",{"key":25,"text":251,"correct":21},"主变压器不需要经常投切；",{"key":28,"text":253,"correct":26},"主变压器需要经常投切，如应对I夜负荷大的变化。",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":229,"analysis":30},1034586,"外桥和内桥相比较，适宜采用外桥接线的条件是（）。",[258,259,261,263],{"key":20,"text":247,"correct":26},{"key":23,"text":260,"correct":21},"电源线路较短，线路故障机会较少",{"key":25,"text":262,"correct":26},"主变压器不需经常投切；",{"key":28,"text":264,"correct":21},"主变压器需要经常投切，如应对昼夜负荷大的变化。",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":267,"answer":102,"analysis":30},1034589,[268,269,270,271],{"key":20,"text":20,"correct":26},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":21},{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":29,"analysis":30},1034591,"GB\u002FT 14549—1993《电能质量公用电网谐波》中，在规定全部用户注入公共连 接点的谐波电流的允许值的同时，还规定了相应的基准短路容量。基准短路容量的作用是 ( )。",[276,278,280,282],{"key":20,"text":277,"correct":21},"当公共连接点处的实际最小短路容量小于基准短路容量时，谐波电流允许值应按比 例降低；",{"key":23,"text":279,"correct":21},"当公共连接点处的实际最小短路容量大于基准短路容量时，谐波电流允许值应按比 例増大；",{"key":25,"text":281,"correct":26},"当公共连接点处的实际最小短路容量小于基准短路容量时，谐波电流允许值应按比 例降低，但当公共连接.点处实际最小短路容量大于基准短路容量时，谐波电流允许值不应再 增加；",{"key":28,"text":283,"correct":26},"谐波电流允许值与实际最小短路容量无关。",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":56,"analysis":30},1034593,"供配电系统设计应根据工程特点、规模和发展规划，做到（）。 A.远近期结合； B以远期为主；C.以近期为主； D.近期服从远期。",[288,289,290,291],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":26},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":26},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":140,"analysis":30},1034596,"供配电系统设计中，采用的电气产品应是（ ）。 A.符合国家现行标准的产品； B优先釆用本省、市、自治区产品； C.效率高、能耗低的产品； D.性能先进的产品.",[296,297,298,299],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":26},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":21},{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":312,"analysis":30},1034599,"为降低波动负荷引起的电网电压变动和闪变，宜采取的措施是（ ）。 A.釆用专用线路供电，将波动负荷接入更高电压等级因而短路容量更大的公共连",[304,306,308,310],{"key":20,"text":305,"correct":21},"接点；",{"key":23,"text":307,"correct":21},"装设静止型动态无功功率补偿，即补偿量的调节速度能跟上负荷波动速度；",{"key":25,"text":309,"correct":26},"装设固定容量的并联电容器，进行容量固定的无功功率补尝；",{"key":28,"text":311,"correct":21},"较大功率的冲击负荷或冲击性负荷群与对电压变动、闪变敏感的负荷分別由不同的 变压器供电。","ABD",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":115,"analysis":30},1034602,"低压配电屏成排布置时，下列（ ）的布置形式通常在设计中采用。",[317,319,321,323],{"key":20,"text":318,"correct":21},"单排布置；",{"key":23,"text":320,"correct":21},"双排面对面布置；",{"key":25,"text":322,"correct":21},"双排背对背布置；",{"key":28,"text":324,"correct":21},"多排同向布置。",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":333,"analysis":30},1034605,"可燃油油浸变压器室下面有地下室，则该变压器室应设置容量为（ ）变压器油量 的挡油设施，或设置容量为（ ）变压器油量的挡油池并能将油排到安全处所的设施。 A. 100%； B80%； C. 50%； D. 20%。",[329,330,331,332],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":26},{"key":25,"text":25,"correct":26},{"key":28,"text":28,"correct":21},"AD",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":29,"analysis":30},1034608,"低压配电室内通道上方有裸带电体时，则该裸带电体距通道地面的高度：屏前通道 不小于（ )，屏后通道不小于（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":21},"2. 5m；",{"key":23,"text":341,"correct":21},"2. 3m;",{"key":25,"text":343,"correct":26},"2. 2m；",{"key":28,"text":345,"correct":26},"2. lm;",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":65,"analysis":30},1034611,"与热水管同侧敷设的电线管应敷设在热水管的下面，其相互间的净距不宜小于 ( );当有困难时，可敷设在上面，其相互间的净距不宜小于（ ）。",[350,352,354,356],{"key":20,"text":351,"correct":26},"0.1m;",{"key":23,"text":353,"correct":21},"0.2m;",{"key":25,"text":355,"correct":21},"0.3m;",{"key":28,"text":357,"correct":26},"0. 4m。",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":115,"analysis":30},1034612,"油量在2500kg以上的屋外相邻油浸变压器之间无防火墙时，其防火净距不得小 于（ ）。 A. 10kV 为 5m;B 35kV 为 5m; C. 63kV 为 6m; D. llOkV 为 8m。",[362,363,364,365],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":21},{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":43,"analysis":30},1034615,"屋内配电装置的硬母线，为消除因温度变化而可能产生的危险应力，应装设母线补 偿器。下列材质的母线，其长度在（）内装设一个母线补偿器。",[370,372,374,376],{"key":20,"text":371,"correct":21},"铜母线，30~50m;",{"key":23,"text":373,"correct":21},"铝母线，20~30m;",{"key":25,"text":375,"correct":21},"铝管母线，30~40m;",{"key":28,"text":377,"correct":26},"钢母线，可不装设。",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":390,"analysis":30},1034618,"选择屋外高压电器的最高环境温度是指（），最低环境温度是指（）。",[382,384,386,388],{"key":20,"text":383,"correct":26},"极端最高温度；",{"key":23,"text":385,"correct":26},"多年的最高温度；",{"key":25,"text":387,"correct":21},"一年中所測得的最低温庋的多年平均值；",{"key":28,"text":389,"correct":21},"—年中所测得的最高温度的多年平均值。","CD",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":390,"analysis":30},1034621,"在llOkV及以下的高压供电系统中，选择屋外裸导体的最髙环境温度是指（ )， 即（ ）。",[395,396,397,399],{"key":20,"text":383,"correct":26},{"key":23,"text":385,"correct":26},{"key":25,"text":398,"correct":21},"最热月平均最高溫度；",{"key":28,"text":400,"correct":21},"最热月每天最高溫度的月平均值的多年平均值。",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":312,"analysis":30},1034624,"3~llOkV屋外配电装置架构的荷载条件，应符合（ )。",[405,407,409,411],{"key":20,"text":406,"correct":21},"计算用气象条件应按当地的气象资料确定；",{"key":23,"text":408,"correct":21},"架构宜根据实际受力条件（包括远景可能发生的不利情况），分别按终端或中间架构 设计；",{"key":25,"text":410,"correct":26},"架构设计应考虑断线；",{"key":28,"text":412,"correct":21},"架构设计应考虑运行、安装、检修、地震情况时的四种荷载组合。",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":312,"analysis":30},1034627,"下列（ ）均称为35kV变电所。 A. 35\u002F10kV变电所； B35\u002F6kV变电所； C. 10\u002F0. 4kV 变电所； D. 35\u002F0.4kV 变电所。",[417,418,419,420],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":26},{"key":28,"text":28,"correct":21},{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":102,"analysis":30},1034630,"10kV变电所所址选择在下列场所时，其中（）是不符合规范要求的。 A.接近负荷中心； B设在厕所的正下方； C.设在浴室的正下方； D.设在地势低洼和可能积水的场所。",[425,426,427,428],{"key":20,"text":20,"correct":26},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":21},{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":229,"analysis":30},1034631,"电缆在室内敷设时，架空明敷的电缆与热力管道的净距不应小于（)；当其净距 小于或等于该值时应采取隔热措施。电缆与非热力管道的净距不应小于（ ），当其净距 小于或等于该值时应在与管道接近的电缆段上，以及由该段两端向外延伸不小于该值以内的 电缆上，采取防止电缆受机械损伤的措施.",[433,435,437,439],{"key":20,"text":434,"correct":26},"0. 8m；",{"key":23,"text":436,"correct":21},"1. 0m；",{"key":25,"text":438,"correct":26},"0. 4m；",{"key":28,"text":440,"correct":21},"0. 5m.",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":56,"analysis":30},1034634,"电缆敷设在两侧有支架的电缆隧道内时，电缆通道宽度的最小净距为（ ）；当电 缆隧道内只有一侧有支架时，则其通道的最小净距为（ ）。",[445,447,449,451],{"key":20,"text":446,"correct":21},"1.0m;",{"key":23,"text":448,"correct":26},"0.8m;",{"key":25,"text":450,"correct":21},"0.9m;",{"key":28,"text":452,"correct":26},"0.5m。",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":29,"analysis":30},1034637,"35~llOkV变电所中下列各建筑物的最低耐火等级符合规范要求的是（ ）。",[457,459,461,463],{"key":20,"text":458,"correct":21},"电缆沟、电缆隧道二级；",{"key":23,"text":460,"correct":21},"有可燃介质的电容器室二级；",{"key":25,"text":462,"correct":26},"主控制室一级；",{"key":28,"text":464,"correct":26},"配电装置室三级。",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":43,"analysis":30},1034640,"35~llOkV变电所内生活建筑与油浸变压器之间的最小防火净距，应根据最大单台 设备的油量及建筑物的耐火等级确定，下列情况下的最小防火净距要求正确的是（ ）。",[469,471,473,475],{"key":20,"text":470,"correct":21},"对一、二级建筑，当油量为5~10t时为15m;",{"key":23,"text":472,"correct":21},"B对三级.建筑，当油量为5~10t时为20m;",{"key":25,"text":474,"correct":21},"C对一、二级建筑，当油量大于10t时为20m;",{"key":28,"text":476,"correct":26},"对三级建筑，当油量大于10t时为15m.",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":43,"analysis":30},1034643,"35~llOkV变电所中下列各建筑物夏季室温，符合规范要求的是（ ）。",[481,483,485,487],{"key":20,"text":482,"correct":21},"电抗器室不宜超过55℃;",{"key":23,"text":484,"correct":21},"油浸变压器室不宜超过45℃",{"key":25,"text":486,"correct":21},"继电器室、电容器室、屋内配电装置室不宜超过40℃;",{"key":28,"text":488,"correct":26},"主控制室及通信室可超过35℃。",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":43,"analysis":30},1034646,"35~llOkV变电所的主控制室顶棚到楼板面的净高，下列符合规范的是（ ）。",[493,495,497,499],{"key":20,"text":494,"correct":21},"当控制室内仅安装控制屏时宜采用3. 4~4.0m;",{"key":23,"text":496,"correct":21},"当控制屏与继电器屏合在一起布置在控制室内时宜采用3.8~4. 4m;",{"key":25,"text":498,"correct":21},"当在控制室内装设空调时可适当降低净空高度；",{"key":28,"text":500,"correct":26},"当在控制室内装设空调时应适当增大净空高度。",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":229,"analysis":30},1034649,"35kV及以下的直埋电力电缆与地下压力水管、自流水管、压缩空气管之间的最小 水平净距为（）与地下热力管之间的最小水平净距为（）。",[505,506,507,509],{"key":20,"text":448,"correct":26},{"key":23,"text":446,"correct":21},{"key":25,"text":508,"correct":26},"1. 8m；",{"key":28,"text":510,"correct":21},"2.0m。",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":65,"analysis":30},1034651,"35kV及以下的直埋电缆与道路、明沟交叉时，则电缆与道路路面、明沟沟底最小 垂直净距分别为（ ）、（ ）。",[515,516,517,519],{"key":20,"text":448,"correct":26},{"key":23,"text":446,"correct":21},{"key":25,"text":518,"correct":21},"0. 5m；",{"key":28,"text":520,"correct":26},"0. 6m。",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":102,"analysis":30},1034653,"安装在地震设防烈度为7度及以上的电力设施，采用下列（ ）抗震措施是适 宜的。",[525,527,529,531],{"key":20,"text":526,"correct":26},"电气设备间连线应采用硬母线；",{"key":23,"text":528,"correct":21},"变压器宜取消滚轮及其轨道，并应固定在基础上。",{"key":25,"text":530,"correct":21},"变压器基础台面宜适当加宽；",{"key":28,"text":532,"correct":21},"开关柜应采用螺栓或焊接的固定方式，当为地震设防烈度为8度或9度时，可将几个柜在重心位置以上连成整体。",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":65,"analysis":30},1034656,"安装在地震设防烈度为8度或9度处的三相限流电抗器较为适宜的布置形式 是（ ）。",[537,539,541,543],{"key":20,"text":538,"correct":26},"髙式布置；",{"key":23,"text":540,"correct":21},"三相水平布置；",{"key":25,"text":542,"correct":21},"三相三角形布置；",{"key":28,"text":544,"correct":26},"三相垂直布置。",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":390,"analysis":30},1034659,"电缆沿输送易燃气体的管道敷设时，应配置在危险程度较低的管道一侧，当易燃气体比 空气重时，电缆宜配置在管道的（），当易燃气体比空气轻时，电缆宜配置在管道的（）。",[549,551,553,555],{"key":20,"text":550,"correct":26},"右侧；",{"key":23,"text":552,"correct":26},"左侧；",{"key":25,"text":554,"correct":21},"上方；",{"key":28,"text":556,"correct":21},"下方。",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":229,"analysis":30},1034662,"户外直埋电缆在非冻土层的埋设深度一般为（），但不得小于（）。",[561,563,565,567],{"key":20,"text":562,"correct":26},"500~600mm;",{"key":23,"text":564,"correct":21},"700~1000mm;",{"key":25,"text":566,"correct":26},"500mm；",{"key":28,"text":568,"correct":21},"700mm?",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":229,"analysis":30},1034665,"电缆隧道、电缆工作井的净空高度不宜小于（ ）；与其他沟道交叉的局部段净空 高度不得小于（ ）。 A. 1200mm； B. 1400mm C 1800mm； D. 1900mm。",[573,574,575,576],{"key":20,"text":20,"correct":26},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":26},{"key":28,"text":28,"correct":21},[578,582,585,588,591,594],{"id":579,"name":580,"category":7,"favorite":581},1,"领导干部任职前廉政法规知识测试题",92,{"id":583,"name":584,"category":7,"favorite":579},595,"建筑结构与设备",{"id":586,"name":587,"category":7,"favorite":579},715,"招标采购专业知识与法律法规",{"id":589,"name":590,"category":7,"favorite":579},848,"市政方向-通用基础",{"id":592,"name":593,"category":7,"favorite":8},534,"BIM工程师",{"id":595,"name":593,"category":7,"favorite":8},535]