[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-32":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":588},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,32,50,2321,[13,35,48,60,73,82,91,104,117,124,132,140,148,160,168,180,193,205,217,230,242,254,266,278,290,302,310,318,330,343,355,364,376,388,400,412,424,436,448,460,472,484,496,508,520,532,544,556,568,580],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1034401,2,"多选题","从概念上讲，电压变动和闪变的关系是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","闪变就是电压变动；",false,{"key":24,"text":25,"correct":26},"B","闪变是灯光照度不稳造成的视感；",true,{"key":28,"text":29,"correct":26},"C","闪变是电压变动引起的，可由电压变动的特性来定量地评定闪变；",{"key":31,"text":32,"correct":26},"D","闪变不但取决于电压变动幅度，而且与电压变动频度有密切关系。","BCD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1034404,"为从概念上区分电压偏移和电压损失，以下叙述中正确的是（ ）。",[39,41,43,45],{"key":20,"text":40,"correct":26},"电压偏移，是系统中某一点的电压与标称（或额定）电压之差，以标称（或颏定） 电压的百分数表示；",{"key":24,"text":42,"correct":26},"电压损失，是串联阻抗元件两端的电压的代数差，可以是有名值，也可用标称（或 颏定）电压的百分数表示；",{"key":28,"text":44,"correct":26},"改变变压器分接头时，可以显著地改变电压偏移，但对电压损失几乎没有影响；",{"key":31,"text":46,"correct":22},"改变变压器分接头时，可以显著地改变电压损失，而对电压偏移几乎没什么影响.","ABC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":47,"analysis":34},1034407,"按GB 12326—2000 ?电能质量电压波动和闪变》的规定，电压变动和电压波动 是两个不同的概念，以下叙述中正确的是（ ）。",[52,54,56,58],{"key":20,"text":53,"correct":26},"电压变动d,是电压变动特性d(t)上相邻两个极值之差，而所谓电压变动特性， 是电压均方根值变动的时间函数，以系统标称电压百分数表示；",{"key":24,"text":55,"correct":26},"B电压波动，是电压均方根一系列的变动或连续的改变；",{"key":28,"text":57,"correct":26},"用作衡量电能质量指标之一的是电压变动；",{"key":31,"text":59,"correct":22},"用作衡量电能质量指标之一的是电压波动。",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":34},1034409,"电力系统公共连接点，由波动负荷产生的电压变动限值与变动频度和电压等级有 关，以下叙述中正确的是（ ）。",[64,66,68,70],{"key":20,"text":65,"correct":26},"电压变动频度r越大，电压变动限值越小；",{"key":24,"text":67,"correct":22},"电压变动频度r越大，电压变动限值越",{"key":28,"text":69,"correct":22},"电压等级越高，电压变动限制越大；",{"key":31,"text":71,"correct":26},"电压等级越高，电压变动限制越小。","AD",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":81,"analysis":34},1034412,"从限制闪变出发，允许波动负荷接人电网的第一级规定是（ ）。",[77,78,79,80],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},"AB",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":90,"analysis":34},1034415,"由闪变指标限制，允许波动负荷接人电网的第二级规定，以下叙述中正确的 是（ ）。",[86,87,88,89],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},"ABCD",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":103,"analysis":34},1034418,"由闪变指标限制，允许波动负荷接入电网的第三级规定，以下叙述中正确的是（ ）。",[95,97,99,101],{"key":20,"text":96,"correct":26},"按一级和二级规定，用户被判超标时，启动第三级规定；",{"key":24,"text":98,"correct":26},"第三级规定重点调研的是：PCC上并不都是波动负荷、实际背景闪变水平及其降低 措施、超标的概率等；",{"key":28,"text":100,"correct":22},"按第三级規定，用户能否接入电网主要由用户自行决定；",{"key":31,"text":102,"correct":26},"按第三级规定，用户能否接入电网主要由电力企业决定。","ABD",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":116,"analysis":34},1034421,"考核电压变动值和闪变值时，选取的运行情况应是（ ）。",[108,110,112,114],{"key":20,"text":109,"correct":26},"电力系统正常运行的小方式；",{"key":24,"text":111,"correct":22},"电力系统最小运行方式；",{"key":28,"text":113,"correct":26},"波动负荷变化最大，波动最频繁的工况；",{"key":31,"text":115,"correct":22},"波动负荷变化最小的工况。","AC",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":119,"answer":47,"analysis":34},1034423,[120,121,122,123],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":81,"analysis":34},1034426,"公共连接点的全部用户向该点注入的谐波电流分量（方均根值）的限值取决 于（ ）。 A.公共连接点的标称电压； B公共连接点的最小短路容量； C.公共连接点的标称頻率偏差； D.公共连接点的标称电压变动。",[128,129,130,131],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":33,"analysis":34},1034429,"为了确定单个用户向公共连接点注人谐波电流的限值，需要知道的电网基础条件 是（ ）. A.该用户的自然功率因数；B公共连接点的最小短路容量； C.该用户的协议用电容量与公共连接点的供电设备容量之比； D.公共连接点的标称电压。",[136,137,138,139],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":103,"analysis":34},1034432,"公用电网电压总谐波畸变率（THD)限值，视电网标称电压不同而不同，具体规 定是( )。",[144,145,146,147],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":116,"analysis":34},1034434,"公用电网各次谐波电压含有率（HRU)限值视电网标称电压不同而不同，具体规 定是（ ）。",[152,154,156,158],{"key":20,"text":153,"correct":26},"0.38kV电网，奇次4%，偶次2.0%;",{"key":24,"text":155,"correct":22},"6~10kV电网，奇次3%，偶次1.5%,",{"key":28,"text":157,"correct":26},"6~10kV电网，奇次3. 2%,偶次1.60%;",{"key":31,"text":159,"correct":22},"6~10kV电网，奇次2. 偶次1.25%。",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":81,"analysis":34},1034437,"全部用户注入公共连接点的谐波电流分量（方均根值）允许值，随公共连接点处 的最小短路容量不同而不同。因此，国家标准给出了决定注入谐波电流分量限值的基准短路 容量，它们是（ ）。 A. 0. 38kV, 10MVA； B 6~10kV, 100MVA; C. 6~10kV, 150MVA; D. 35kV, 200MVA,",[164,165,166,167],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":72,"analysis":34},1034440,"一级负荷供电电源应符合的规定是（）。",[172,174,176,178],{"key":20,"text":173,"correct":26},"一级负荷应由两个电源供电；当一个电源发生故障时，另一个电源不应同时受到 损坏；",{"key":24,"text":175,"correct":22},"一级负荷应由两个电源供电；当一个电源发生故障时，允许另一个电源受到牵连而 同时损坏；",{"key":28,"text":177,"correct":22},"一级负荷中特别重要的负荷，在已有两个电源供电的条件下，不必另设应急电源；",{"key":31,"text":179,"correct":26},"一级负荷中特别重要的负荷，除两个电源供电外，尚应增设应急电源，并严禁将其 他负荷接入急级供电系。",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":192,"analysis":34},1034442,"可作为一级负荷中特别重要负荷的应急电源的应是（ ）。",[184,186,188,190],{"key":20,"text":185,"correct":26},"独立于正常电源的发电机组；",{"key":24,"text":187,"correct":22},"供电网络中与正常电源接于同一母线的第二回馈电线路；",{"key":28,"text":189,"correct":26},"供电网络中独立于正常电源的专用馈电线路；",{"key":31,"text":191,"correct":26},"蓄电池、干电池等不受正常电源故障影响的贮能设备。","ACD",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":90,"analysis":34},1034445,"用户设置自备电源的适合条件是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":26},"需要设置自备电源作为一级负荷中的特别重要负荷的应急电源时或第二电源不能满 足一级负荷对供电可靠性的要求时；",{"key":24,"text":200,"correct":26},"设置自备电源较从电力系统取得第二电源经济合理时；",{"key":28,"text":202,"correct":26},"有常年稳定余热、压差、废气可供发电，技术可靠、经济合理时；",{"key":31,"text":204,"correct":26},"所在地区偏僻，远离电力系统，设置自备电源经济合理时。",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":116,"analysis":34},1034448,"在考虑供电电源时，下列说法中符合设计规范规定的是（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":26},"对一级负荷的两个供电电源，应该是一个电源发生故障时，另一个电源不会同时受 到损坏；",{"key":24,"text":212,"correct":22},"对一级负荷中特别重要的负荷，当已有两个电源供电时，可不再增设应急电源；",{"key":28,"text":214,"correct":26},"受条件限制，二级负荷可由一个电源引一因路专用电缆供电，但该回路应由两根电 缆并联，且每根电缆能承受100%的二级负荷；",{"key":31,"text":216,"correct":22},"受条件限制，二级负荷可由一个电源引一回路专用架空线供电，但该回路应由两根 导线并联，且每根导线能承受100%的二极负荷。",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":229,"analysis":34},1034451,"需要两回路电源线路的用电单位，选择电源线路电压的原则是（ ）",[221,223,225,227],{"key":20,"text":222,"correct":22},"两回路必须为同级电压；",{"key":24,"text":224,"correct":26},"两回路宜为同级电压；",{"key":28,"text":226,"correct":26},"C按不同负荷的需要和电网条件，两回路可采用不同级电压；",{"key":31,"text":228,"correct":22},"禁止两回路采用不同级电压。","BC",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":103,"analysis":34},1034454,"当电网对用户的供电电源为35kV及以上时，确定用户内部配电电压的原则 是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":26},"用户内部一级配电电压一般采用10kV;",{"key":24,"text":237,"correct":26},"当中等容量电动机总容量较大，经比较计算经济合理时，宜采用6kV电压配电；",{"key":28,"text":239,"correct":22},"禁止采用35kV电压配电，禁止由35kV电压直降380\u002F220V配电；",{"key":31,"text":241,"correct":26},"低压配电电压应采用380\u002F220V。",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":90,"analysis":34},1034456,"用电单位的供电电的选择，粗略地讲，以下说法（）是对的。",[246,248,250,252],{"key":20,"text":247,"correct":26},"用电负荷很大的企业采用220kV或llOkV;",{"key":24,"text":249,"correct":26},"用电负荷较大的企业采用llOkV或35kV;",{"key":28,"text":251,"correct":26},"负荷不大的企业采用10kV;",{"key":31,"text":253,"correct":26},"负荷很小的企业可接入地区低压电网。",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":81,"analysis":34},1034459,"在选定企业内部配电电压等级时，由于绝缘材料新技术的发展，35kV塑料绝缘电 缆制造技术的进步，中等容量（200~2000kW) 10kV电动机造价的降低，目前（也只是目 前）的趋势是（）。",[258,260,262,264],{"key":20,"text":259,"correct":26},"采用10kV代替6kV, 6kV用得越来越少；",{"key":24,"text":261,"correct":26},"采用35kV代替10kV，35kV用得越来越多；",{"key":28,"text":263,"correct":22},"采用6kV代替10kV, 10kV用得越来越少；",{"key":31,"text":265,"correct":22},"采用10kV代替35kV，35kV用得越来越少。",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":90,"analysis":34},1034460,"低压配电系统带电导体的型式，我国常用的有（ ）。",[270,272,274,276],{"key":20,"text":271,"correct":26},"单相两线制；",{"key":24,"text":273,"correct":26},"两相三线制；",{"key":28,"text":275,"correct":26},"三相三线制；",{"key":31,"text":277,"correct":26},"三相四线制。",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":47,"analysis":34},1034462,"系统接地型式有TN、TT、IT三种，其正确含义是（ ）。",[282,284,286,288],{"key":20,"text":283,"correct":26},"TN：电源端有一点直接接地，电气装置的外露可导电部分通过保护中性导体或保 护导体连接到此接地点；",{"key":24,"text":285,"correct":26},"TT：电源端有一点直接接地，电气装置的外露可导电部直接接地，此接地点在电气 上独立于电源端的接地点；",{"key":28,"text":287,"correct":26},"IT：电源端的带电部分不接地或有一点通过阻抗接地，电气装置的外露可导电部分 直接接地；",{"key":31,"text":289,"correct":22},"IT：电源端有一点直接接地，电气装置的外露可导电部分通过保护中性导体或保护 导体接到此接地点，",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":33,"analysis":34},1034464,"中性导体（N)、保护导体（P E)、保护中性导体（PEN)的正确定义是（ ）。 A.中性导体（N):与系统中性点相连接，不能起传输电能作用的导体；",[294,296,298,300],{"key":20,"text":295,"correct":22},"中性导体（N):与系统中性点相连接，并能起传输电能作用的导体；",{"key":24,"text":297,"correct":26},"C保护导体（P",{"key":28,"text":299,"correct":26},"某些防电击措施要求的，用来与下列任一部分作电气连接的导体: ①外露可导电部分；②装置外的可导电部分；③总接地端子或主接地导体；④接地极；⑤电 源接地点或人工接地点。",{"key":31,"text":301,"correct":26},"保护中性导体（PEN):具有中性导体和保护导体两种功能的接地导体，",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":81,"analysis":34},1034466,"低压配电，宜采用树干式配电的条件是（ ）。 A.环境正常； b大部分用电设备为中、小容量； C.大部分用电设备为大容量； D.负荷性质很重要。",[306,307,308,309],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":103,"analysis":34},1034468,"低压配电宜采用放射式配电的条件是（ ）。 A.用电设备容量大； B负荷性质重要； C.用电设备大部分为中、小容量； D.有特殊要求的车间或建筑物内。",[314,315,316,317],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":229,"analysis":34},1034470,"髙层建筑物内，选择配电方式的正确原则是（ ）。",[322,324,326,328],{"key":20,"text":323,"correct":22},"向楼层各配电点供电时，宜采用放射式；",{"key":24,"text":325,"correct":26},"向楼层各配电点供电时，宜采用分区树干式；",{"key":28,"text":327,"correct":26},"对部分较大容量的集中负荷或重要负荷，应从低压配电室以放射式供电；",{"key":31,"text":329,"correct":22},"对部分放大容量的集中负荷或重要负荷，宜采用树干式供电。",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":342,"analysis":34},1034471,"低压配电系统设计的正确原则之一是（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":22},"互为备用的生产机组，宜由同一回路配电；",{"key":24,"text":337,"correct":26},"互为备用的生产机组，宜由不同的回路配电；",{"key":28,"text":339,"correct":22},"平行的生产流水线的生产机组，宜由不同的回路配电；",{"key":31,"text":341,"correct":26},"平行的生产流水线的生产机组，宜由同一回路配电。","BD",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":47,"analysis":34},1034473,"我国6~35kV电网，除个别特殊地区外，中性点接地方式有（ ).",[347,349,351,353],{"key":20,"text":348,"correct":26},"不接地；",{"key":24,"text":350,"correct":26},"经消弧线圈接地；",{"key":28,"text":352,"correct":26},"经低电阻接地；",{"key":31,"text":354,"correct":22},"直接接地",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":363,"analysis":34},1034475,"发生单相接故障时，能带故障继续运行1~2h的中性点接地方式是（ ）。 A.直接接地； B经低电阻接地； C.经消弧线围接地； D.不接地。",[359,360,361,362],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},"CD",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":192,"analysis":34},1034477,"下列对中性点不接地系统的特征的描述中正确的是（)*",[368,370,372,374],{"key":20,"text":369,"correct":26},"实际上是相线经电容接地系统。单相接地故障时，有容性电流流经故障点，可形成 狐光重燃过电压，其数值居各种中性点接地方式之首；",{"key":24,"text":371,"correct":22},"单相接地故障时，非故障相对地电压升髙，同时破坏了线电压的对称性，电网不能继续工作；",{"key":28,"text":373,"correct":26},"单相接地故障时，非故障相对地电压升高而线电压对称性并未受到破坏，故允许电 网带故障继续运行1~2h;",{"key":31,"text":375,"correct":26},"电网带单相接地故障运行，易发展为相间短路。",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":90,"analysis":34},1034480,"下列对中性点经消弧线圈接地电网的特征的描述中正确的是（ )。",[380,382,384,386],{"key":20,"text":381,"correct":26},"中性点与大地之间接入电感量可调的消弧线圈，向单相接地故障点提供大小可调的 感性电流，以抵消原来的容性电流，使流过故障点的残余电流很小，接地电弧不能维持而 熄灭；",{"key":24,"text":383,"correct":26},"B感性电流应调节到与容性电流恰好相等，即全补偿；",{"key":28,"text":385,"correct":26},"感姓电流应调节得小于容性电流，即欠补偿； ^ 4?",{"key":31,"text":387,"correct":26},"感性电流应调节到大于容性电流，即过补偿。",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":192,"analysis":34},1034483,"下列对中性点经低电阻接地电网的特征的描述中正确的是（ ）。",[392,394,396,398],{"key":20,"text":393,"correct":26},"能抑制单相接地时的异常过电压；",{"key":24,"text":395,"correct":22},"B单相接地故障时，电网仍能继续带故障工作；",{"key":28,"text":397,"correct":26},"单相接地故障时，必须切除故障，电网不能带故障继续工作；",{"key":31,"text":399,"correct":26},"电网参数变化，如某些线路和元件的投入和退出，不必调节接地电阻阻值，",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":103,"analysis":34},1034486,"下列对中性点直接接地电网的特征的描述中正确的是（ ）",[404,406,408,410],{"key":20,"text":405,"correct":26},"中性点不经任何人为设罝的阻抗，直接与大地连接；",{"key":24,"text":407,"correct":26},"限制操作过电压和弧光接地过电压的效果最好；",{"key":28,"text":409,"correct":22},"单相接地故障时，可以带故障继续工作1~2h;",{"key":31,"text":411,"correct":26},"对通信的感应危害最大。",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":90,"analysis":34},1034489,"供配电系统设计中，为减小电压偏差，通常采取的措施有（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":26},"正确选择变压器变压比和电压分接头；",{"key":24,"text":419,"correct":26},"降低系统阻抗；",{"key":28,"text":421,"correct":26},"采取无功补偿措施；",{"key":31,"text":423,"correct":26},"宜使三相负荷平衡。",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":33,"analysis":34},1034491,"计算电压偏差时，应计人采取（ ）措施的调压结果。",[428,430,432,434],{"key":20,"text":429,"correct":22},"限制用户用电量；",{"key":24,"text":431,"correct":26},"自动或手动调整同步电动机励磁电流；",{"key":28,"text":433,"correct":26},"C改变供配电系统运行方式；",{"key":31,"text":435,"correct":26},"自动或手动调整并联补偿电容器、并联电抗器的接入容量。",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":81,"analysis":34},1034494,"变电所中的变压器应采用有载调压的情况为（）。",[440,442,444,446],{"key":20,"text":441,"correct":26},"35kV以上电压的变电所中的降压变压器，直接向35kV、10 (6) kV电网供电时",{"key":24,"text":443,"correct":26},"35kV降压变电所的主变压器，在电压偏差不能满足要求时；",{"key":28,"text":445,"correct":22},"全部35kV主降压变压器；",{"key":31,"text":447,"correct":22},"全部10 (6) kV配电变压器。",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":229,"analysis":34},1034497,"10 (6) kV配电变压器采用有载调的合适条件是（）。",[452,454,456,458],{"key":20,"text":453,"correct":22},"变压器结构为干式时；",{"key":24,"text":455,"correct":26},"当地10(6) kV电源电压偏差不能满足要求时；",{"key":28,"text":457,"correct":26},"用电单位有对电压偏差要求严格的设备，且单独为这呰设备单独设置调压装置又不 经济或不合理时；",{"key":31,"text":459,"correct":22},"变压器放置在特殊场所。",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":81,"analysis":34},1034499,"电压偏差和电压损失的正确定义分别是（）。",[464,466,468,470],{"key":20,"text":465,"correct":26},"电压偏差，是供配电系统中某一个点的电压与该点的标称电压的代数差，用标称电 压的百分数表；",{"key":24,"text":467,"correct":26},"B电压损失，是供配电系统中某一或某些串联阻抗元件两端电压的代数差，用标称电 压的百分数表示；",{"key":28,"text":469,"correct":22},"电压偏差，是供配电系统中某一或某些串联阻抗元件两端电压的代数差，用标称电 压的百分数表示；",{"key":31,"text":471,"correct":22},"电压损失，是供配电系统中某一个点的电压与该点的标称电压的代数差，用标称电 压的百分数表示。",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":33,"analysis":34},1034502,"有关电压偏差和电压损失的概念，以下描述中正确的是（ ）",[476,478,480,482],{"key":20,"text":477,"correct":22},"电压偏差就是电压损失；",{"key":24,"text":479,"correct":26},"电压损失是产生电压偏差的原因之一；",{"key":28,"text":481,"correct":26},"电压偏差属于变化缓慢、稳定时间较长的量，不同于快速变化的电压波动；",{"key":31,"text":483,"correct":26},"电压偏差不同于电压损失。",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":116,"analysis":34},1034505,"即便合理选择无励磁调压（无载调压）变压器的电压分接头，也只能使电压偏差 达到（)。",[488,490,492,494],{"key":20,"text":489,"correct":26},"正偏差减小的同时，负偏差的绝对值加大；",{"key":24,"text":491,"correct":22},"正偏差减小的同时，负偏差的绝对值减少；",{"key":28,"text":493,"correct":26},"正、负偏差绝对值之和不能改变；",{"key":31,"text":495,"correct":22},"正、负偏差绝对值之和变小。",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":33,"analysis":34},1034508,"假如供配电系统中某节点电压偏差为负值且其绝对值过大，在该节点加装并联电 容器能取得显著改善效果的条件是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"该节点的负荷，功率因数很高，已达0.9~0.95;",{"key":24,"text":503,"correct":26},"该节点的负荷功率因数较低；",{"key":28,"text":505,"correct":26},"C该节点的电源侧元件以感性为主（如架空线〉；",{"key":31,"text":507,"correct":26},"该节点的电源侧元件以阻性为主（如小截面电缆）。",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":103,"analysis":34},1034511,"在供配电设计中，为满足电网对用户功率因数的要求，首先应采取措施提高用户 的自然功率因数，提高用户自然功率因数的正确措施为（）。",[512,514,516,518],{"key":20,"text":513,"correct":26},"正确选择电动机和变压器容量，避免\"大马拉小车”；",{"key":24,"text":515,"correct":26},"降低供配电线路的感抗",{"key":28,"text":517,"correct":22},"选用阻抗电压较大的变压器；",{"key":31,"text":519,"correct":26},"工艺条件适合时，用同步电动机取异步电动机.",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":47,"analysis":34},1034514,"采用并联电容器做无功功率补偿时，正确的配置原则是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":26},"宜就地平衡补偿。低压部分所缺无功功率，宜在低压补偿；高压部分所缺无功，宜 在高压补偿；",{"key":24,"text":527,"correct":26},"容量大、负荷平稳且经常使用的设备的无功功率补偿，宜单独就地补偿；补偿基本 无功功率的电容器组，宜在变配电所内集中补偿；",{"key":28,"text":529,"correct":26},"在环境正常的车间内，低压电容器宜分散补偿；",{"key":31,"text":531,"correct":22},"宜在总变配电所母线上集中全部无功补偿。",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":81,"analysis":34},1034516,"当接入电容器的电网谐波水平显著时，应在电容器回路采用的措施是（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":26},"串入电抗器；",{"key":24,"text":539,"correct":26},"视串入电抗器电抗值的大小，适当提高电容器的颏定电压；",{"key":28,"text":541,"correct":22},"串入电阻器；",{"key":31,"text":543,"correct":22},"串入压敏电阻。",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":229,"analysis":34},1034520,"在并联电容器回路中串入电抗器的作用是（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":22},"母线电压偏高时，降低电容器上的工频电压；",{"key":24,"text":551,"correct":26},"如电抗器电抗值选择适当，能减少流入电容器的谐波电流；",{"key":28,"text":553,"correct":26},"限制电容投入时的暂态涌流；",{"key":31,"text":555,"correct":22},"改善投切电容器的断路器的熄弧条件。",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":33,"analysis":34},1034523,"投切低压电容器组的接触器，应是（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"一般的，无特殊要求；",{"key":24,"text":563,"correct":26},"B专用的；",{"key":28,"text":565,"correct":26},"能投切规定的容性电流而不重燃；",{"key":31,"text":567,"correct":26},"能将投切暂态过电压限制在安全范围之内。",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":81,"analysis":34},1034526,"高压电容器组的接线方式（当每相中串联电容台数为1时），三角形与星形比较， 以下描述中正确的是（ ）。",[572,574,576,578],{"key":20,"text":573,"correct":26},"三角形接线，当电容器组发生电容器全击穿时，即相当于相间短路，易引起电容器 油箱爆炸；",{"key":24,"text":575,"correct":26},"星形接线，当电容器组发生电容器全击穿时，故障电流受到健全相电容器容抗的限 制而大大降低，减小了电容器油箱爆炸的危险；",{"key":28,"text":577,"correct":22},"三角形接线，当电容器组发生电容器全击穿时，不构成相间短路；",{"key":31,"text":579,"correct":22},"星形接线，当电容器组发生电容器全击穿时，即相当于相间短路。",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":81,"analysis":34},1034529,"低压电容器组可采用的接线方式是（ ）。 A.三角形； B中性点不接地星形； C.中性点直接接地的星形； D. B相接地的三角形。",[584,585,586,587],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},[589,593,596,599,602,605],{"id":590,"name":591,"category":7,"favorite":592},1,"领导干部任职前廉政法规知识测试题",92,{"id":594,"name":595,"category":7,"favorite":590},595,"建筑结构与设备",{"id":597,"name":598,"category":7,"favorite":590},715,"招标采购专业知识与法律法规",{"id":600,"name":601,"category":7,"favorite":590},848,"市政方向-通用基础",{"id":603,"name":604,"category":7,"favorite":8},534,"BIM工程师",{"id":606,"name":604,"category":7,"favorite":8},535]