[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-30":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":546},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,30,50,2321,[13,35,48,57,65,77,86,94,107,119,127,135,144,153,161,173,185,197,206,218,226,238,246,258,270,282,294,306,318,330,337,345,353,361,373,382,394,402,414,422,434,446,458,466,478,491,503,515,527,538],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1034133,2,"多选题","关于变压器的有功损耗，下列叙述（）是正确的。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","变压器的有功损耗包括铁损和铜损；",true,{"key":24,"text":25,"correct":26},"B","铁损的数值与变压器铁芯材质有关，且与变压器负荷电流成正比；",false,{"key":28,"text":29,"correct":22},"C","负载电流为額定值时的铜损又称短路损失；",{"key":31,"text":32,"correct":22},"D","铜损与负荷电流平方成正比。","ACD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1034136,"有关直流电动机和交流电动机的效率，下列说法（ ）是正确的。",[39,41,43,45],{"key":20,"text":40,"correct":22},"直流电动机的效率通常比交流电动机低；",{"key":24,"text":42,"correct":26},"与同一容量的交流电动机相比，直流电动机的效率要高2%~3%左右；",{"key":28,"text":44,"correct":22},"C直流电动机的励磁是连续使用的，其通风冷却的电耗是不可忽视的；",{"key":31,"text":46,"correct":26},"与交流电动机相比，直流电动机的励磁损耗和铜损比较小。","AC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":56,"analysis":34},1034139,"关于异步电动机的功率因数，下列说法（）是错误的。",[52,53,54,55],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},"AD",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":59,"answer":64,"analysis":34},1034142,[60,61,62,63],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},"BCD",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":64,"analysis":34},1034144,"以下电动机的（）与异步电动机的负载电流关系不密切。",[69,71,73,75],{"key":20,"text":70,"correct":26},"铜损；",{"key":24,"text":72,"correct":22},"铁损；",{"key":28,"text":74,"correct":22},"机械损耗；",{"key":31,"text":76,"correct":22},"杂散损耗。",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":79,"options":80,"answer":85,"analysis":34},1034146,"异步电动机端电压的波动将引起异步电动机特性变化。以下（ ）电机特性的变 化是由于电压下降引起的。 A.起动转矩减小； B.最大转矩减小； C.颏定负载时电机溫度下降； D額定负载时电流增大*",[81,82,83,84],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},"ABD",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":33,"analysis":34},1034149,"异步电动机端电压的波动将引起异步电动机特性变化。当异步电动机的端电压髙于 額定电压时，会引起（）。 A.额定负载时电流减小； B同步转速提高； C额定负载时功率因数降低 D.起动转矩增加。",[90,91,92,93],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":106,"analysis":34},1034152,"以下措施()可以实现节能效果。",[98,100,102,104],{"key":20,"text":99,"correct":22},"选用低损耗电力变压器替换高损耗电力变压器；",{"key":24,"text":101,"correct":22},"设计时选用高效电动机；",{"key":28,"text":103,"correct":22},"将交流接触器的电磁操作线圏的电流由原来的交流改为直流；",{"key":31,"text":105,"correct":22},"在水泵运行中采用变频调速控制流量替代用阀门开度调节流量","ABCD",{"id":108,"libraryId":5,"type":15,"typeLabel":16,"stem":109,"options":110,"answer":33,"analysis":34},1034155,"关于照明设备节电方法以下（ ）是正确的。",[111,113,115,117],{"key":20,"text":112,"correct":22},"增设照明灯开关，每个照明开关控制灯的数量不要过多；",{"key":24,"text":114,"correct":26},"尽量多采用36V以下照明灯具；",{"key":28,"text":116,"correct":22},"除特殊情况外，不应采用管型卤钨灯及大功率白炽灯；",{"key":31,"text":118,"correct":22},"不应采用效率低于75%的开敞式灯具。",{"id":120,"libraryId":5,"type":15,"typeLabel":16,"stem":121,"options":122,"answer":85,"analysis":34},1034158,"在供配电系统中避免重复降压，简化电压等级是有力的降损措施，以下（）降 压方式是适合的. A. 220\u002F110\u002F10\u002F0.38kV； B220\u002F66\u002F10\u002F0.38kV； c. 220\u002F110\u002F66\u002F35\u002F10\u002F0.38kV； D. 220\u002F35\u002F10\u002F0.38kV。",[123,124,125,126],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":64,"analysis":34},1034160,"合理选择线路导线截面是供配电系统节能措施之一。线路架设时，应按经济电流密 度来选择导线截面，经济电流密度是综合考虑（）因素后制定的 A.供电电压等级； B年运行费用； C.有色金属消耗； D.建设投资。",[131,132,133,134],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":143,"analysis":34},1034162,"根据经济电流密度曲线，年最大负荷利用小时数越（ )，经济电流值越（ ) A.大，大； B大，小； C.小，小；D.小，大",[139,140,141,142],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},"BD",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":152,"analysis":34},1034165,"在负载电流不变的条件下，配电线路换截面较大导线的节电和提高供电质量的效果 表现在（ ）方面。 A.换线前后线路单位电抗值变化不大，电阻值变化明显，节电效果主要是有功功率的 节约； B.减小了配电线路的阻抗； C减小电压偏差； D.节约线路投资。",[148,149,150,151],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},"ABC",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":56,"analysis":34},1034168,"以下四组35kV供电系统电压偏差值 ()超出了允许偏差。 A. +5%, -6%; B.+5%, -5%,C-10%, 一3%; D. +10%,-2%",[157,158,159,160],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":47,"analysis":34},1034171,"以下四组220V单相供电系统电压偏差值（ ）在允许偏差范围内.",[165,167,169,171],{"key":20,"text":166,"correct":22},"+5%, -8%",{"key":24,"text":168,"correct":26},"-10%, -7%；",{"key":28,"text":170,"correct":22},"+8%, -5%；",{"key":31,"text":172,"correct":26},"+10%，-6%.",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":47,"analysis":34},1034174,"有关接于公共连接点的每个用户引起该点正常电压不平衡度允许值的规定，以下叙 述（ ）是正确的。",[177,179,181,183],{"key":20,"text":178,"correct":22},"允许值一般为1.3%;",{"key":24,"text":180,"correct":26},"根据连接点的负荷状况可作适当变动，但允许值不超过1.5%;",{"key":28,"text":182,"correct":22},"C根据连接点的负荷状况可作适当变动，但必须满足允许值为2%，短时不得超过4% 的規定；",{"key":31,"text":184,"correct":26},"允许值不得超过1.3%.",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":33,"analysis":34},1034176,"对于标称频率为50Hz的电力系统用户冲击负荷引起的系统频率变动应符合下列 ( )规定。",[189,191,193,195],{"key":20,"text":190,"correct":22},"一般不得超过±0.2Hz;",{"key":24,"text":192,"correct":26},"B不得超过±0.1Hz；",{"key":28,"text":194,"correct":22},"C根据冲击负荷性质和大小以及系统的条件也可适当变动限值；",{"key":31,"text":196,"correct":22},"变动限制应保证近区电力网、发电机组和用户的安全稳定运行及安全供电",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":205,"analysis":34},1034178,"电力系统公共连接点，由波动负荷产生的电压变动限值与以下（）参数有关。 A.电网频率； B.变动頻率； C电压等级； D.系统短路容量。",[201,202,203,204],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},"BC",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":47,"analysis":34},1034181,"交流电力系统中的电气设备，在运行中除了作用有持续工频电压外，还受到过电压 的作用。按照作用过电压的幅值、波形及持续时间可分为暂时过电压和瞬时过电压。以下 ( )属于暂时过电压。",[210,212,214,216],{"key":20,"text":211,"correct":22},"工频过电压；",{"key":24,"text":213,"correct":26},"雷电过电压；",{"key":28,"text":215,"correct":22},"谐振过电压；",{"key":31,"text":217,"correct":26},"操作过电压。",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":64,"analysis":34},1034184,"工频过电压一般由（ ）引起。 A.线路重合闸；B线路空载； C.甩负荷； D.接地故障。",[222,223,224,225],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":106,"analysis":34},1034187,"操作过电压一般由（ )引起。",[230,232,234,236],{"key":20,"text":231,"correct":22},"线路切、合与重合闸；",{"key":24,"text":233,"correct":22},"故障与切除故障；",{"key":28,"text":235,"correct":22},"开断容性电流和开断较小或中等的感性电流；",{"key":31,"text":237,"correct":22},"负载突变。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":152,"analysis":34},1034190,"以下（ ）是减少电动机损耗的措施。 A.增加转子和定子铁芯长庋、减少磁通密度； B增加定子导线截面； c.采用高润滑轴承； D.电机定子外部保护漆的颜色不得为白色。",[242,243,244,245],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":56,"analysis":34},1034191,"以下措施（)可以作为风机、水泵类负载的节电措施。",[250,252,254,256],{"key":20,"text":251,"correct":22},"采用变頻调速控制电动机的转速，实现水泵流量的调节；",{"key":24,"text":253,"correct":26},"更换大电机，使风机、水泵电机负载率小于50%；",{"key":28,"text":255,"correct":26},"选择高精度的流量检测装置，准确测量风机、水泵流量；",{"key":31,"text":257,"correct":22},"采用液力耦合器控制成机、水泵电机的转速，实现风机风量、水泵流量的调节.",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":152,"analysis":34},1034194,"选择3kV以上高压电器时，其噪声水平应满足环保标准的要求。在距设备外沿垂 直面的水平距离为2m,离地高度为1. 5m处电器的噪声应满足下列（）要求。",[262,264,266,268],{"key":20,"text":263,"correct":22},"电器的连续噪声水平不应大于85dB;",{"key":24,"text":265,"correct":22},"B断路器的非连续噪声水平屋内不宜大于90dB;",{"key":28,"text":267,"correct":22},"C断路器的非连续噪声水平屋外不宜大于llOdB;",{"key":31,"text":269,"correct":26},"断路器的非连续噪声水平屋内不宜大于85dB。",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":106,"analysis":34},1034197,"在建筑中充分利用天然光，符合节能和环保的要求。以下（ ）是照明工程充分 利用天然光的有效措施。",[274,276,278,280],{"key":20,"text":275,"correct":22},"在经济条件允许时，采用各种导光装置，将光引入室内进行照明；",{"key":24,"text":277,"correct":22},"采用各种反光装置使光折向房间深处，提高照度；",{"key":28,"text":279,"correct":22},"利用太阳能作为照明能源；",{"key":31,"text":281,"correct":22},"随室外天然光的变化自动调节人工照度。",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":205,"analysis":34},1034200,"选择低耗能变压器，减少变压器的损耗是供配电系统节能的重要措施。对于S7、 Sll、S9、新S9、SJ、SH (非晶态合金变压器）等不同型号的变压器，在额定容量相同的条件下，比较其空载损耗的大小，下列（）排列是正确的。",[286,288,290,292],{"key":20,"text":287,"correct":26},"SJ",{"key":24,"text":289,"correct":22},"SJ>S9>S11>SH;",{"key":28,"text":291,"correct":22},"S7>S9>新 S9>SH;",{"key":31,"text":293,"correct":26},"S11",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":47,"analysis":34},1034203,"关于变压器效率，以下说法( )是正确的。",[298,300,302,304],{"key":20,"text":299,"correct":22},"变压器效率与变压器负荷和损耗有关；",{"key":24,"text":301,"correct":26},"变压器效率与负荷功率因数无关；",{"key":28,"text":303,"correct":22},"当变压器负载系数为有功经济负载系数时，变压器效率最高；",{"key":31,"text":305,"correct":26},"当变压器负载率大于85%时效率最高。",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":33,"analysis":34},1034205,"关于降低变压器的能耗以下观点和措施（ )是正确的。",[310,312,314,316],{"key":20,"text":311,"correct":22},"选择空载损耗较小的低耗能变压器s",{"key":24,"text":313,"correct":26},"尽可能使变压器运行在满载状况；",{"key":28,"text":315,"correct":22},"随着变压器空载损耗降低，变压器最大效率点的负栽系数降低；",{"key":31,"text":317,"correct":22},"当铜损等于铁损时，变压器的有功功率损失率最低。",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":106,"analysis":34},1034208,"以下措施（）对减小电网谐波有效。",[322,324,326,328],{"key":20,"text":323,"correct":22},"增加换流装置的脉动数，采用12相整流装置；",{"key":24,"text":325,"correct":22},"在谐波源附近安装高通滤波装置；",{"key":28,"text":327,"correct":22},"对冲击负荷加装动态无功补偿装置；",{"key":31,"text":329,"correct":22},"在用户进线处加串联电抗器。",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":332,"answer":28,"analysis":34},1034210,[333,334,335,336],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":33,"analysis":34},1034212,"负荷计箅的内容通常包括（）。 a.需要负荷或最大负荷； b.经济运行负荷； c.平均负荷； d.尖峰电流。",[341,342,343,344],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":85,"analysis":34},1034215,"负荷计箅的内容不包括(） a.高次谐波电流； b.起动冲击电流； c.尖峰电流； d.单相接地电流。",[349,350,351,352],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":64,"analysis":34},1034217,"计箅负荷的正确应用是（）。 a.最大平均负荷用于按发热条件选择导体； b需要负荷或最大负荷用于按发热条件选择导体； c.需要负荷或最大负荷用于计算电压偏差； d.尖峰电流用于计算电压波动。",[357,358,359,360],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":33,"analysis":34},1034220,"需要系数法适用于（ ）",[365,367,369,371],{"key":20,"text":366,"correct":22},"a.用电设备台数较多时；",{"key":24,"text":368,"correct":26},"b用电设备台数不多、功率悬殊时;",{"key":28,"text":370,"correct":22},"c.工业企业电力负荷计算；",{"key":31,"text":372,"correct":22},"d.工业企业照明负荷计算。",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":152,"analysis":34},1034223,"利用系数法适用于（ ）",[377,378,380,381],{"key":20,"text":366,"correct":22},{"key":24,"text":379,"correct":22},"b.用电设备台数不多、功率悬殊时;",{"key":28,"text":370,"correct":22},{"key":31,"text":372,"correct":26},{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":205,"analysis":34},1034225,"单位指标法适用于（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":26},"a.设备选定的工业厂房电力负荷计算;",{"key":24,"text":389,"correct":22},"b.设备未定的工业厂房电力负荷估算；",{"key":28,"text":391,"correct":22},"c.民用建筑照明负荷计算；",{"key":31,"text":393,"correct":26},"d.建筑设备机房电力负荷计算。",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":152,"analysis":34},1034227,"单位指标法适用于（ ） a.工业企业设计前期负荷估算； c.负荷计算结果的核定； b.民用建筑施工设计负荷计算; d.灯具选定的照明负荷计算。",[398,399,400,401],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":85,"analysis":34},1034229,"负荷计算时，应将设备功率换箅到负载持续率为100%下的有功功率的是（）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"a.电焊机，采用需要系数法计算时；",{"key":24,"text":409,"correct":22},"b.电焊机，采用利用系数法计算时；",{"key":28,"text":411,"correct":26},"c.短时或周期工作制的电动机，采用需要系数法计算时；",{"key":31,"text":413,"correct":22},"d.短时或周期工作制的电动机，采用利用系数法计算时。",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":85,"analysis":34},1034232,"负荷计箅时，不应将设备功率换算到负载持续率为25%下的有功功率的是（）",[418,419,420,421],{"key":20,"text":407,"correct":22},{"key":24,"text":409,"correct":22},{"key":28,"text":411,"correct":26},{"key":31,"text":413,"correct":22},{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":33,"analysis":34},1034235,"负荷计算中电动机的设备功率是（）。 A.连续工作制电动机的额定功率；",[426,428,430,432],{"key":20,"text":427,"correct":22},"短时或周期工作制电动机的額定功率；",{"key":24,"text":429,"correct":26},"短时或周期工作制电动机在负栽持续率为100%下的有功功率（用利用系数法计算时)",{"key":28,"text":431,"correct":22},"短时或周期工作制电动机在负栽持续率为25%下的有功功率（用需要系数法计算时)",{"key":31,"text":433,"correct":22},")",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":143,"analysis":34},1034252,"负荷计箅中变压器的设备功率是（ ）。",[438,440,442,444],{"key":20,"text":439,"correct":26},"电炉变压器在额定电流时的额定容量；",{"key":24,"text":441,"correct":22},"电炉变压器在額定功率因数时的有功功率；",{"key":28,"text":443,"correct":26},"整流变压器在额定功率因数时的有功功率；",{"key":31,"text":445,"correct":22},"整流变压器的额定直流功率。",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":33,"analysis":34},1034254,"负荷计箅中照明灯具的设备功率是（ ）。",[450,452,454,456],{"key":20,"text":451,"correct":22},"白炽灯的灯泡额定功率；",{"key":24,"text":453,"correct":26},"荧光灯的灯管额定功率；",{"key":28,"text":455,"correct":22},"金属卤化物灯的灯管额定功率加镇流器损耗；",{"key":31,"text":457,"correct":22},"卤钨灯的灯管额定功率。",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":205,"analysis":34},1034257,"可不计人变电所或建筑物的总设备功率是（ ）。 A.正常点燃的应急照明； B正常不点燃的应急照明； C消火栓泵和喷淋泵； D.兼作服务梯的消防电梯。",[462,463,464,465],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":85,"analysis":34},1034260,"采用需要系数法计箅负荷时，正确的做法是（ ）。",[470,472,474,476],{"key":20,"text":471,"correct":22},"先求用电设备组的计算负荷；",{"key":24,"text":473,"correct":22},"B若干用电设备组的计算负荷相加时，应乘以同时系数；",{"key":28,"text":475,"correct":26},"C若干变电所的计算负荷相加时，不再乘以同时系数；",{"key":31,"text":477,"correct":22},"多级电压配电的各级负荷相加时，均可乘以同时系数。",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":490,"analysis":34},1034262,"计箅变电所高压侧负荷时，正确的做法是（ ）。",[482,484,486,488],{"key":20,"text":483,"correct":26},"忽略变压器的損耗；",{"key":24,"text":485,"correct":26},"只计入变压器的有功功率损耗;",{"key":28,"text":487,"correct":22},"计入变压器的有功功率损耗；",{"key":31,"text":489,"correct":22},"计入变压器的无功功率损耗.","CD",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":143,"analysis":34},1034264,"电力负荷应根据（ ）进行分级。",[495,497,499,501],{"key":20,"text":496,"correct":26},"计算负荷的数量；",{"key":24,"text":498,"correct":22},"B对供电可靠性的要求；",{"key":28,"text":500,"correct":26},"地区电力系统的供电能力；",{"key":31,"text":502,"correct":22},"中断供电在政治上、经济上所造成的损失或影响的程度。",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":33,"analysis":34},1034266,"电力负荷应为一级负荷中特别重要负荷的是（ ）。",[507,509,511,513],{"key":20,"text":508,"correct":22},"中断供电将造成人身伤亡的负荷?，",{"key":24,"text":510,"correct":26},"中断供电将造成重大政治、经济损失的负荷；",{"key":28,"text":512,"correct":22},"中断供电将发生中毒、爆炸和火灾等情况的负荷；",{"key":31,"text":514,"correct":22},"特别重要场所的不允许中断供电的负荷，如国宾馆、国家级大会堂的接见厅、主会 场等的照明负荷。",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":526,"analysis":34},1034268,"电力负荷应为一级负荷的是（ ）。",[519,521,522,524],{"key":20,"text":520,"correct":22},"中断供电将造成人身伤亡的负荷；",{"key":24,"text":510,"correct":22},{"key":28,"text":523,"correct":26},"C中断供电将在政治、经济上造成较大损失的负荷；",{"key":31,"text":525,"correct":26},"中断供电将造成较多人员集中的重要公共场所秩序混乱者。","AB",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":205,"analysis":34},1034270,"电力负荷应为二级负荷的是（ 〉。",[531,532,534,536],{"key":20,"text":510,"correct":26},{"key":24,"text":533,"correct":22},"中断供电将在政治、经济上造成较大损失的负荷；",{"key":28,"text":535,"correct":22},"中断供电将造成较多人员集中的重要公共场所秩序混乱者；",{"key":31,"text":537,"correct":26},"经常用于国际活动的大量人员集中的公共场所。",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":490,"analysis":34},1034272,"电力负荷应为三级负荷的是（ )。 A.中断供电将在经济上造成较大损失的负荷； B中断供电影响重要用电单位正常工作的负荷； c一般货梯和自动扶梯； D.不属于一级和二级的电力负荷。",[542,543,544,545],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},[547,551,554,557,560,563],{"id":548,"name":549,"category":7,"favorite":550},1,"领导干部任职前廉政法规知识测试题",92,{"id":552,"name":553,"category":7,"favorite":548},595,"建筑结构与设备",{"id":555,"name":556,"category":7,"favorite":548},715,"招标采购专业知识与法律法规",{"id":558,"name":559,"category":7,"favorite":548},848,"市政方向-通用基础",{"id":561,"name":562,"category":7,"favorite":8},534,"BIM工程师",{"id":564,"name":562,"category":7,"favorite":8},535]