[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":504},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,3,50,2321,[13,34,42,54,66,78,90,102,114,126,138,150,162,170,182,194,202,214,222,234,246,258,270,278,286,294,302,314,322,331,339,347,355,363,371,379,387,399,407,416,424,432,440,448,456,464,472,480,488,496],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1030642,1,"单选题","某标称电压为10.5kV配电线路实际电压为9. 5kV,为了减少线路功率损耗，计划 将实际电压提高。在输送功率和负载功率因数不变的条件下，提高实际电压1%，功率损耗 降低（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1.97%；",true,{"key":24,"text":25,"correct":26},"B","2.0%i",false,{"key":28,"text":29,"correct":26},"C","2.11%；",{"key":31,"text":32,"correct":26},"D","2. 15%.","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1030646,"某标称电压为10.5kV配电线路实际电压为10kV，近日因周边用电负荷增加，该 配电线路的实际电压降低了1%。 在输送功率和负载功率因数不变的条件下，因配电线路电 压降低，线路功率损耗增加（ ）。 A. 1.06%, B 1.99%; C. 2.03%; D. 2.11%。",[38,39,40,41],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":31,"analysis":33},1030650,"电力系统公共连接点正常电压不平衡度允许值为（ ），短时不得超过（ ）。",[46,48,50,52],{"key":20,"text":47,"correct":26},"1%, 2%；",{"key":24,"text":49,"correct":26},"2%, 3%；",{"key":28,"text":51,"correct":26},"4%, 2%；",{"key":31,"text":53,"correct":22},"2%, 4%。",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":24,"analysis":33},1030654,"某能源中心建设面积为250m2主计算机房，问计算机房内磁场干扰环境场强不应大 于（ ）。",[58,60,62,64],{"key":20,"text":59,"correct":26},"700A\u002Fm；",{"key":24,"text":61,"correct":22},"800A\u002Fm；",{"key":28,"text":63,"correct":26},"900A\u002Fm,",{"key":31,"text":65,"correct":26},"950A\u002Fm。",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":20,"analysis":33},1030682,"交流接触器加装节电器后，将操作电磁系统（），可减少铁芯和短路环中功率损耗，取得较高的节电效果。",[70,72,74,76],{"key":20,"text":71,"correct":22},"由交流操作改为直流吸持;",{"key":24,"text":73,"correct":26},"由直流线圈改为交流线圈",{"key":28,"text":75,"correct":26},"由 220VAC 改为 380VAC;",{"key":31,"text":77,"correct":26},"由铝导线改为铜导线",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":24,"analysis":33},1030686,"某车间有一台额定容量为8000kVA电力变压器，其二次侧负载为4500kW, cosp2= 0.9时，该变压器的负载率为（ ）",[82,84,86,88],{"key":20,"text":83,"correct":26},"69.4%；",{"key":24,"text":85,"correct":22},"62.5%",{"key":28,"text":87,"correct":26},"56.2%；",{"key":31,"text":89,"correct":26},"41. 1%。",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":31,"analysis":33},1030689,".照明节能评价采用房间或场所一般照明的（）作为照明节能的评价指标，该指标 单位为（ ）。",[94,96,98,100],{"key":20,"text":95,"correct":26},"标称电压，V;",{"key":24,"text":97,"correct":26},"灯具效率，n;",{"key":28,"text":99,"correct":26},"照度，lx,",{"key":31,"text":101,"correct":22},"功率密度，W\u002Fm2。",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":28,"analysis":33},1030693,"某变电所设630kVA和1000kVA变压器各一台，有三种运行方式：①630kVA变 压器单台运行；②1OOOkVA变压器单台运行；③两台变压 器同时运行。图2-1曲线1、2、3分别为该变电所①、②、 ③三种运行方式变压器损耗与负荷关系的曲线。当运行负 荷为1200、800、400kVA时，采用（ )运行方式变压 器损耗最小。",[106,108,110,112],{"key":20,"text":107,"correct":26},"①、②、③",{"key":24,"text":109,"correct":26},"①、③、②；",{"key":28,"text":111,"correct":22},"③、②、①",{"key":31,"text":113,"correct":26},"②、③、①,",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":28,"analysis":33},1030697,"35kV及以上供电电压的允许偏差为：正、负偏差的绝对值之和不超过标称系统电 压的（ ）。",[118,120,122,124],{"key":20,"text":119,"correct":26},"15%；",{"key":24,"text":121,"correct":26},"12%;",{"key":28,"text":123,"correct":22},"10%;",{"key":31,"text":125,"correct":26},"7%。",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":28,"analysis":33},1030701,"由于化石燃料燃烧产生二氧化碳（CC2)等有害气体，造成地球的臭氧层破坏、地 球变暖、酸雨等问题。节约电能可减少大量大气污染物。使用燃煤、燃油、燃气三种方式发 电，每节约lkWh的电能，可减少二氧化碳（co2)的传播量为（ ）、（ ）和（ ）。",[130,132,134,136],{"key":20,"text":131,"correct":26},"200g、960g、840g,",{"key":24,"text":133,"correct":26},"640g、llOOg、860g；",{"key":28,"text":135,"correct":22},"llOOg、 860g、 640g;",{"key":31,"text":137,"correct":26},"840g、 1100g、 1500g。",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":28,"analysis":33},1030704,"下列关于负荷计箅的论述中，正确的是（ ）。",[142,144,146,148],{"key":20,"text":143,"correct":26},"计算负荷是一个确定的负荷，与用途无关；",{"key":24,"text":145,"correct":26},"计算负荷是一个假想的持续负荷，在电力系统中产生的各种效应与变动的实际负荷 相等；",{"key":28,"text":147,"correct":22},"计算负荷是一个假想的持续负荷，在一定的时间中产生的特定效应与变动的实际负 荷相等；",{"key":31,"text":149,"correct":26},"尖峰电流是一个持续时间很短电流，不属于负荷计算的内容。",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":24,"analysis":33},1030708,"下列关于负荷计箅中设备功率的论述中，正确的是（ ）。",[154,156,158,160],{"key":20,"text":155,"correct":26},"设备功率是用电设备在额定功率因数和额定负载持续率下的额定功率；",{"key":24,"text":157,"correct":22},"设备功率是用电设备的額定功率或容量换算为统一负载持续率下的有功功率；",{"key":28,"text":159,"correct":26},"设备功率的换算与所采用的负荷计算方法无关；",{"key":31,"text":161,"correct":26},"设备功率的计取与用电设备的工作方式无关。",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":31,"analysis":33},1030712,"如采用利用系数法，在换箅短时或周期工作制的电动机的设备功率时，统一负载持 续率应取（ ）。 A. 15%； B. 25%; C 40%； D. 100%。",[166,167,168,169],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":20,"analysis":33},1030716,"负荷计箅时，连续工作制电动机的设备功率应为（ ）。",[174,176,178,180],{"key":20,"text":175,"correct":22},"电动机的额定功率；",{"key":24,"text":177,"correct":26},"电动机的输入功率；",{"key":28,"text":179,"correct":26},"负载持续率为25％的有功功率；",{"key":31,"text":181,"correct":26},"负载持续率为40%的有功功率。",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":31,"analysis":33},1030720,"负荷计箅中电焊机的设备功率应为（）。",[186,188,190,192],{"key":20,"text":187,"correct":26},"额定负载持续率下的视在功率;",{"key":24,"text":189,"correct":26},"负载持续率为25%的有功功率;",{"key":28,"text":191,"correct":26},"额定功率因数下的有功功率；",{"key":31,"text":193,"correct":22},"负载持续率为100%的有功功率。",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":24,"analysis":33},1030723,"负荷计箅时，电炉变压器的设备功率应为（ ） A.电炉变压器的额定容量； B额定功率因数下的有功功率; C.电炉的額定功率； D.电炉功率加短网损耗。",[198,199,200,201],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":28,"analysis":33},1030727,"负荷计箅时，整流器的设备功率应为（）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"额定交流视在功率；",{"key":24,"text":209,"correct":26},"额定交流有功功率；",{"key":28,"text":211,"correct":22},"额定直流输出功率；",{"key":31,"text":213,"correct":26},"流用电设备的计算功率。",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":31,"analysis":33},1030730,"负荷计箅时，用电设备组的设备功率（） A.应包括备用设备； B宜包括备用设备； C.宜包括部分备用设备； D.包括备用设备不应",[218,219,220,221],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":28,"analysis":33},1030734,"负荷计算时，季节性负荷应取（）",[226,228,230,232],{"key":20,"text":227,"correct":26},"季节性负荷之和i",{"key":24,"text":229,"correct":26},"季节性负荷的平均值；",{"key":28,"text":231,"correct":22},"季节性负荷中计算负荷较大者；",{"key":31,"text":233,"correct":26},"季节性负荷中运行时间较长着",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":31,"analysis":33},1030738,"负荷计箅时，划分用电设备组的原则是（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":26},"设备功率相近；",{"key":24,"text":241,"correct":26},"功率因数相同；",{"key":28,"text":243,"correct":26},"需要系数或利用系数相同；",{"key":31,"text":245,"correct":22},"符合B+C。",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":28,"analysis":33},1030741,"在单、三相混合负荷计箅时，单相负荷应换算为等效三相负荷的条件是（）",[250,252,254,256],{"key":20,"text":251,"correct":26},"单相负荷的计算功率超过三相负荷的计算功率的15%;",{"key":24,"text":253,"correct":26},"单相负荷的计算功率超过全部负荷的计算功率的15%;",{"key":28,"text":255,"correct":22},"单相负荷的设备功率之和超过三相负荷的设备功率之和的15%;",{"key":31,"text":257,"correct":26},"单相负荷的设备功率之和超过全部负荷的设备功率之和的15%。",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":24,"analysis":33},1030745,"单相负荷应换箅为等效三相负荷时，正确的做法是（）。",[262,264,266,268],{"key":20,"text":263,"correct":26},"无论采用何种计算法，均取设备功率；",{"key":24,"text":265,"correct":22},"无论采用何种计算法，均取计算功率；",{"key":28,"text":267,"correct":26},"采用需要系数法时，取平均功率；",{"key":31,"text":269,"correct":26},"采用利用系数法时，取需要功率。",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":33},1030749,"单相负荷换箅为等效三相负荷时，如既有线间负荷又有相负荷，应先将线间负荷换 箅为相负荷，再将各相负荷分别相加，然后选取最大相负荷的（）倍作为等效三相负荷。",[274,275,276,277],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":31,"analysis":33},1030754,"单相负荷换箅为等效三相负荷时，如只有线间负荷，等效三相负荷应取最大线间负荷的 倍加次大线间负荷的（）倍。",[282,283,284,285],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":20,"analysis":33},1030758,"单相负荷换箅为等效三相负荷时，如只有一个线间负荷，等效三相负荷应取线间负荷的（）倍。",[290,291,292,293],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":24,"analysis":33},1030760,"单相负荷换箅为等效三相负荷时，如均为相负荷，等效三相负荷应取最大相负荷的 ()倍.",[298,299,300,301],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":31,"analysis":33},1030764,"中断供电将造成人身伤亡时，应为（）。",[306,308,310,312],{"key":20,"text":307,"correct":26},"一级负荷；",{"key":24,"text":309,"correct":26},"二级负荷；",{"key":28,"text":311,"correct":26},"C三级负荷；",{"key":31,"text":313,"correct":22},"—级负荷中特别重要负荷",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":31,"analysis":33},1030767,"中断供电将发生中毒、爆炸和火灾等情况时，应为（） A. 一级负荷； B 二级负荷； C三级负荷； D. —级负荷中特别重要负荷。",[318,319,320,321],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":20,"analysis":33},1030771,"中断供电将造成重大政治、经济损失时，应为（ ）。",[326,327,328,329],{"key":20,"text":307,"correct":22},{"key":24,"text":309,"correct":26},{"key":28,"text":311,"correct":26},{"key":31,"text":330,"correct":26},"—级负荷中特别重要负荷。",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":24,"analysis":33},1030775,"中断供电将造成较大政治、经济损失时，应为（）。 A. —级负荷； B. 二级负荷； c.三级负荷； D —级负荷中特別重要负荷。",[335,336,337,338],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":33},1030779,"中断供电将影响重要用电单位正常工作时，应为（）。 A. 一级负荷； B 二级负荷； C.三级负荷； D. —级负荷中特別重要负荷.",[343,344,345,346],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":20,"analysis":33},1030782,"中断供电将影响有重大政治、经济意义的用电单位正常工作时，应为（ ） A. —级负荷；B 二级负荷； C.三级负荷； D. —级负荷中特别重要负荷。",[351,352,353,354],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":20,"analysis":33},1030786,"中断供电将造成重大设备损坏、重大产品报废、国民经济中重点企业的连续生产过 程被打乱需要长时间才能恢复时，应为（）。 a. 一级负荷; b. 二级负荷；c.三级负荷; d. 一级负荷中特别重要负荷。",[359,360,361,362],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":24,"analysis":33},1030789,"中断供电将造成主要设备损坏、大量产品报废、连续生产过程被打乱需要较长时间 才能恢复时，应为（）。 a. 一级负荷； B 二级负荷； c.三级负荷； d. —级负荷中特别重要负荷。",[367,368,369,370],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":20,"analysis":33},1030793,"中断供电将造成大量人员集中的重要公共场所秩序严重混乱时，应为（）。 a. 一级负荷； B二级负荷； c.三级负荷； d. —级负荷中特別重要负荷",[375,376,377,378],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":24,"analysis":33},1030797,"中断供电将造成大型影剧院、大型商场等较多人员集中的重要公共场所秩序混乱 时，应为（）。 a. 一级负荷； b. 二级负荷； c.三级负荷； d. —级负荷中特别重要负荷。",[383,384,385,386],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":20,"analysis":33},1030800,"大型体育场馆中的重要电力、照明负荷，应为（ ）。",[391,393,395,397],{"key":20,"text":392,"correct":22},"a. 一级负荷；",{"key":24,"text":394,"correct":26},"b. 二级负荷；",{"key":28,"text":396,"correct":26},"c.三级负荷；",{"key":31,"text":398,"correct":26},"d. 一级负荷中特别重要负荷。",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":31,"analysis":33},1030805,"大型国际比赛场馆的计时记分系统，应为（） a. 一级负荷；b. 二级负荷； c.三级负荷； d. 一级负荷中特别重要负荷。",[403,404,405,406],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":20,"analysis":33},1030809,"甲级体育场的比赛场照明，应为（ ）",[411,412,413,414],{"key":20,"text":392,"correct":22},{"key":24,"text":394,"correct":26},{"key":28,"text":396,"correct":26},{"key":31,"text":415,"correct":26},"d.—级负荷中特别重要负荷",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":24,"analysis":33},1030812,"乙级体育馆的比赛厅照明，应为（ ） a. 一级负荷； b. 二级负荷；c.三级负荷； d. —级负荷中特别重要负荷,",[420,421,422,423],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":20,"analysis":33},1030815,"甲等剧场的舞台照明，应为（ ） a. —级负荷； b. 二级负荷c.三级负荷； d. 一级负荷中特别重要负荷",[428,429,430,431],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":24,"analysis":33},1030818,"甲等剧场的观众厅照明，应为（） a. 一级负荷；b. 二级负荷;c.三级负荷；d. 一级负荷中特别重要负荷。",[436,437,438,439],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":20,"analysis":33},1030821,"大型银行的营业厅照明，应为（ ） a. —级负荷；b. 二级负荷； c.三级负荷； d. 一级负荷中特别重要负荷。",[444,445,446,447],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":24,"analysis":33},1030824,"小型银行的营业厅照明，应为（）。 a. —级负荷；B 二级负荷； c.三级负荷； D. 一级负荷中特别重要负荷。",[452,453,454,455],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":31,"analysis":33},1030827,"银行、大型博物馆的防盗报警系统，应为（) a. 一级负荷；b. 二级负荷； c.三级负荷； d. 一级负荷中特别重要负荷.",[460,461,462,463],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":31,"analysis":33},1030829,"省级电视台、广播电台的电子计算机系统，应为（ ）。 a. 一级负荷； B 二级负荷； c.三级负荷； d. —级负荷中特别重要负荷。",[468,469,470,471],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":20,"analysis":33},1030832,"一、二级旅馆的餐厅和主要通道照明、主要客梯电力，应为（ ）。 a. 一级负荷； B二级负荷； c.三级负荷； d. —级负荷中特别重要负荷。",[476,477,478,479],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":24,"analysis":33},1030835,"三级旅馆的宴会厅和高级客房照明、主要客梯电力，应为（）。 a. —级负荷;b. 二级负荷； c.三级负荷; d. 一级负荷中特别重要负荷.",[484,485,486,487],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":20,"analysis":33},1030839,"县级以上医院的手术部电力和照明，应为（ ) a. 一级负荷；b. 二级负荷； c.三级负荷； d. 一级负荷中特别重要负荷",[492,493,494,495],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":24,"analysis":33},1030842,"县级以上医院的高级病房，应为（) a. 一级负荷；b. 二级负荷； c三级负荷； d. 一级负荷中特别重要负荷,",[500,501,502,503],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},[505,508,511,514,517,520],{"id":15,"name":506,"category":7,"favorite":507},"领导干部任职前廉政法规知识测试题",92,{"id":509,"name":510,"category":7,"favorite":15},595,"建筑结构与设备",{"id":512,"name":513,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":515,"name":516,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":518,"name":519,"category":7,"favorite":8},534,"BIM工程师",{"id":521,"name":519,"category":7,"favorite":8},535]