[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-29":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":621},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,29,50,2321,[13,34,46,57,69,80,92,104,116,131,144,157,170,183,196,208,221,233,245,258,270,282,294,302,314,326,338,346,358,371,379,391,403,415,427,439,451,463,475,487,499,511,524,536,548,561,573,585,597,609],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1033994,1,"单选题","该鼠笼型电动机的额定起动容量为（ ）（选最接近的一个数据）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1353k VA；",true,{"key":24,"text":25,"correct":26},"B","1204k VA；",false,{"key":28,"text":29,"correct":26},"C","1120k VA ；",{"key":31,"text":32,"correct":26},"D","1042kV","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1033997,"该直流电动机的额定电流为（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"90A；",{"key":24,"text":41,"correct":22},"11OA",{"key":28,"text":43,"correct":26},"120A;",{"key":31,"text":45,"correct":26},"135",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":48,"answer":24,"analysis":33},1034000,[49,51,53,55],{"key":20,"text":50,"correct":26},"88.90A；",{"key":24,"text":52,"correct":22},"87.69A",{"key":28,"text":54,"correct":26},"80.11A；",{"key":31,"text":56,"correct":26},"77. 27",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":31,"analysis":33},1034003,"某车间欲选用一台整流变压器给主回路采用全控三相桥线路的变流装置供电。经计 箅整流变压器一次容量为3364kV A，二次容量为3474kV",[61,63,65,67],{"key":20,"text":62,"correct":26},"则该整流变压器的等值容量为( )。",{"key":24,"text":64,"correct":26},"6837kVA； 5128kVA；",{"key":28,"text":66,"correct":26},"4835kVA；",{"key":31,"text":68,"correct":22},"3419kV",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":71,"answer":28,"analysis":33},1034005,[72,74,76,78],{"key":20,"text":73,"correct":26},"22. 5A；",{"key":24,"text":75,"correct":26},"35.1A；",{"key":28,"text":77,"correct":22},"44. 7A；",{"key":31,"text":79,"correct":26},"58. 6",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":20,"analysis":33},1034008,"某低压交流异步电动机额定电压380V,额定功率90kW,额定电流169. 5A,全压 启动时启动电流为1186. 5A, Y 降压启动时，启动电流为（ ）。",[84,86,88,90],{"key":20,"text":85,"correct":22},"396A；",{"key":24,"text":87,"correct":26},"685A；",{"key":28,"text":89,"correct":26},"839A；",{"key":31,"text":91,"correct":26},"1186",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":28,"analysis":33},1034011,"某高压交流电动机额定电压6000V,额定功率1450kW,额定电流183 A，全压启动 时启动电流为1080",[96,98,100,102],{"key":20,"text":97,"correct":26},"采用自稱变压器降压启动，减压百分数为80%。则采用自耦变压器 降压启动后，启动电流为（ ）。",{"key":24,"text":99,"correct":26},"109. 2A; R 518. 9Af",{"key":28,"text":101,"correct":22},"691. 2A；",{"key":31,"text":103,"correct":26},"949. 2",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":20,"analysis":33},1034014,"某高压交流电动机额定电压6000V,额定功率1450kW,额定电流183A,全压启动 时启动电流为1080A,采用电抗器降压启动时，启动电压与额定电压之比为0.92,则采用 电抗器降压启动时，启动电流为（ ）。",[108,110,112,114],{"key":20,"text":109,"correct":22},"994A；",{"key":24,"text":111,"correct":26},"1189A;",{"key":28,"text":113,"correct":26},"1213A;",{"key":31,"text":115,"correct":26},"1290",{"id":117,"libraryId":5,"type":118,"typeLabel":119,"stem":120,"options":121,"answer":130,"analysis":33},1034017,2,"多选题","防空地下室内安装的变压器、断路器、电容器等高低压电气设备应釆用（ ） 设备。",[122,124,126,128],{"key":20,"text":123,"correct":22},"防潮；",{"key":24,"text":125,"correct":26},"防电磁干扰；",{"key":28,"text":127,"correct":22},"无油；",{"key":31,"text":129,"correct":26},"防爆.","AC",{"id":132,"libraryId":5,"type":118,"typeLabel":119,"stem":133,"options":134,"answer":143,"analysis":33},1034020,"下列（ ）情况之一时，可燃油油浸变压器室的门应为甲级防火门。",[135,137,139,141],{"key":20,"text":136,"correct":22},"变压器室位于车间内；",{"key":24,"text":138,"correct":22},"变压器室位于容易沉积可燃粉尘、可燃纤维的场所；",{"key":28,"text":140,"correct":26},"变压器室位于河流、湖泊附近；",{"key":31,"text":142,"correct":22},"附近有粮、棉及其他易燃物大量集中的露天堆场。","ABD",{"id":145,"libraryId":5,"type":118,"typeLabel":119,"stem":146,"options":147,"answer":156,"analysis":33},1034024,"根据有关规范中强制性条文的规定，以下建筑物消防用电设备供配电系统的设置 ( )是正确的。",[148,150,152,154],{"key":20,"text":149,"correct":22},"建筑高度为60m的丙类仓库的消防用电按一级负荷供电；",{"key":24,"text":151,"correct":22},"消防用电设备设专用供电回路；",{"key":28,"text":153,"correct":26},"C消防水泵房电源就近由空调机房配电室引来；",{"key":31,"text":155,"correct":26},"座位数为2000个的体育馆，消防用电按一级负荷供电。","AB",{"id":158,"libraryId":5,"type":118,"typeLabel":119,"stem":159,"options":160,"answer":169,"analysis":33},1034027,"以下公共建筑的灯光疏散指示标志的设置位置（）是正确的。",[161,163,165,167],{"key":20,"text":162,"correct":22},"沿疏散走道；",{"key":24,"text":164,"correct":26},"电梯间；",{"key":28,"text":166,"correct":22},"安全出口",{"key":31,"text":168,"correct":22},"人员密集场所的疏散门。","ACD",{"id":171,"libraryId":5,"type":118,"typeLabel":119,"stem":172,"options":173,"answer":182,"analysis":33},1034030,"以下对防空地下室内部电源的发动机组的选择原则（ ）是错误的。",[174,176,178,180],{"key":20,"text":175,"correct":26},"应采用柴油发电机组；",{"key":24,"text":177,"correct":22},"严禁采用柴油发电机组；",{"key":28,"text":179,"correct":26},"严禁采用汽油发电机组；",{"key":31,"text":181,"correct":22},"应采用汽油发电机组。","BD",{"id":184,"libraryId":5,"type":118,"typeLabel":119,"stem":185,"options":186,"answer":195,"analysis":33},1034033,"爆炸性气体环境的电力设计应符合下列（）规定.",[187,189,191,193],{"key":20,"text":188,"correct":22},"爆炸性气体环境的电力设计宜将正常运行时发生火花的电气设备，布置在爆炸危险 性较小或没有爆炸危险的环境内；",{"key":24,"text":190,"correct":22},"在满足工艺生产及安全的前提下，应减少防爆电器设备的数量；",{"key":28,"text":192,"correct":22},"C爆炸性气体环境内设置的防爆电气设备，必须是符合现行国家标准的产品；",{"key":31,"text":194,"correct":26},"严禁采用携带式电气设备.","ABC",{"id":197,"libraryId":5,"type":118,"typeLabel":119,"stem":198,"options":199,"answer":182,"analysis":33},1034036,"以下要求（）符合爆炸性气体环境电气线路的设计和安装要求.",[200,202,204,206],{"key":20,"text":201,"correct":26},"在1区内应用铜芯导线，在2区内严禁用铝芯导线；",{"key":24,"text":203,"correct":22},"在1区内单相网络中的相线及中性线均应装设短路保护，并使用双极开关同时切断 相线及中性线；",{"key":28,"text":205,"correct":26},"当易燃物质比空气重时，电气线路宜在较低处敷设或在电缆沟敷设；",{"key":31,"text":207,"correct":22},"在爆炸性气体环境内，工作中性线的绝缘额定电压应与相线电压相等，并应在同一 护套或管子内敷设。",{"id":209,"libraryId":5,"type":118,"typeLabel":119,"stem":210,"options":211,"answer":220,"analysis":33},1034038,"爆炸性气体环境中选用正压型电气设备及通风系统时，以下措施（ ）是正 确的。",[212,214,216,218],{"key":20,"text":213,"correct":26},"在电气设备及其通风系统运行中，其风压不应低于20Pa;",{"key":24,"text":215,"correct":26},"电气设备严禁与通风系统连锁；",{"key":28,"text":217,"correct":22},"运行前必须先通风，并应在通风量大于电气设备及其通风系统容积的5倍时才能接 通电气设备的主电源；",{"key":31,"text":219,"correct":22},"通风过程排出的气体不宜排入爆炸危险环境。","CD",{"id":222,"libraryId":5,"type":118,"typeLabel":119,"stem":223,"options":224,"answer":156,"analysis":33},1034041,"爆炸性气体环境内的车间采用下列（ ）措施后，车间可降为非爆炸危险环境。",[225,227,229,231],{"key":20,"text":226,"correct":22},"正压；",{"key":24,"text":228,"correct":22},"连续通风稀释；",{"key":28,"text":230,"correct":26},"机械排风；",{"key":31,"text":232,"correct":26},"负压。",{"id":234,"libraryId":5,"type":118,"typeLabel":119,"stem":235,"options":236,"answer":169,"analysis":33},1034044,"下列条件中（ ）符合爆炸性粉尘环境的电力设计规定。",[237,239,241,243],{"key":20,"text":238,"correct":22},"宜将电气设备和线路，特别是正常运行时能产生火花的电气设备布置在爆炸性粉尘 环境以外；",{"key":24,"text":240,"correct":26},"事故易发地点必须装设局部照明灯和插座；",{"key":28,"text":242,"correct":22},"爆炸性粉尘环境内，有可能过负荷的电气设备，应装设可靠的过负荷保护；",{"key":31,"text":244,"correct":22},"在爆炸性粉尘环境采用非防爆型电气设备进行隔墙机械传动时，安装电气设备的房 间应采用非燃烧体的实体墙与爆炸性粉尘环境隔开。",{"id":246,"libraryId":5,"type":118,"typeLabel":119,"stem":247,"options":248,"answer":257,"analysis":33},1034047,"以下要求（ ）不符合爆炸性粉尘环境接地设计的规定。",[249,251,253,255],{"key":20,"text":250,"correct":22},"为了提高接地的可靠性，接地干线必须在爆炸危险区域内仅一处与接地体连接；",{"key":24,"text":252,"correct":26},"电气设备的接地装置与防止直接雷击的独立避雷针的接地装置应分开设置；",{"key":28,"text":254,"correct":26},"爆炸性粉尘坏境内电气设备的金属外壳应可靠接地；",{"key":31,"text":256,"correct":22},"电气设备的接地装置与装设在建筑物上防止直接雷击的避雷针的接地装置可合并设 置，接地电阻值应取其中最高值。","AD",{"id":259,"libraryId":5,"type":118,"typeLabel":119,"stem":260,"options":261,"answer":257,"analysis":33},1034049,"火灾危险环境21区内，以下电气线路的敷设方式（ ）是错误的。",[262,264,266,268],{"key":20,"text":263,"correct":22},"电动起重机采用滑触线供电；",{"key":24,"text":265,"correct":26},"采用钢管配线明敷；",{"key":28,"text":267,"correct":26},"采用硬塑料管配线；",{"key":31,"text":269,"correct":22},"绝缘导线在针式絶缘子上明敷。",{"id":271,"libraryId":5,"type":118,"typeLabel":119,"stem":272,"options":273,"answer":182,"analysis":33},1034052,"根据工程建设标准强制性条文，油浸电力变压器、充有可燃油的高压电容器和多油 开关等用房受条件限制必须布置在民用建筑物内时，不应布置在（ ）.",[274,276,278,280],{"key":20,"text":275,"correct":26},"上部人员稀少的地下室一层靠外墙部位；",{"key":24,"text":277,"correct":22},"人员密集场所的上一层；",{"key":28,"text":279,"correct":26},"首层；",{"key":31,"text":281,"correct":22},"貼邻人员密集场所。",{"id":283,"libraryId":5,"type":118,"typeLabel":119,"stem":284,"options":285,"answer":130,"analysis":33},1034054,"消防用电设备的配电线路应满足火灾时连续供电的需要，下列配电线路的敷设要求 ( )是正确的。",[286,288,290,292],{"key":20,"text":287,"correct":22},"在保护层厚度为40mm的混凝土结构内穿钢管暗敷；",{"key":24,"text":289,"correct":26},"穿塑料管明敷；",{"key":28,"text":291,"correct":22},"采用有防火保护的封闭式金属线槽明敷；",{"key":31,"text":293,"correct":26},"穿无防火保护的金属管明敷。",{"id":295,"libraryId":5,"type":118,"typeLabel":119,"stem":296,"options":297,"answer":220,"analysis":33},1034057,"某高度为120m的高层建筑内采用蓄电池作应急照明和疏散指示标志的电源，以下 几种蓄电池的连续供电时间，（）符合规范要求。 A. 15min； B. 25min； C 35min； D. 40min.",[298,299,300,301],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":303,"libraryId":5,"type":118,"typeLabel":119,"stem":304,"options":305,"answer":169,"analysis":33},1034060,"高层民用建筑漏电火灾报警系统应具备（ ）功能。",[306,308,310,312],{"key":20,"text":307,"correct":22},"探测漏电电流、过电流等信号，发出声光信号报警，准确报出故障线路地址，监视 故陣点的变化；",{"key":24,"text":309,"correct":26},"存储各种故障和操作试验信号，信号存储时间不应少于24个月；",{"key":28,"text":311,"correct":22},"切断漏电线路上的电源并显示其状态；",{"key":31,"text":313,"correct":22},"显示系统电源状态。",{"id":315,"libraryId":5,"type":118,"typeLabel":119,"stem":316,"options":317,"answer":257,"analysis":33},1034063,"以下措施（ )是间接接触防护的正确措施。",[318,320,322,324],{"key":20,"text":319,"correct":22},"采用Ⅱ类设备或等效的绝缘用以防止电气设备的可触及部分因基本绝缘故障而出现 的危险电压；",{"key":24,"text":321,"correct":26},"采用剩余电流保护器",{"key":28,"text":323,"correct":26},"C-可同时接触的不同电位的部分不应在伸臂范围之内；",{"key":31,"text":325,"correct":22},"当回路设备中发生带电部分与外露可导电部分之间的故障时，应在5s内自动切断提 供该设备的电源。",{"id":327,"libraryId":5,"type":118,"typeLabel":119,"stem":328,"options":329,"answer":169,"analysis":33},1034066,"抗震烈度为7度及以上的变压器类设备安装设计应符合下列（）要求。",[330,332,334,336],{"key":20,"text":331,"correct":22},"基础台面宜适当加宽；",{"key":24,"text":333,"correct":26},"不得取消滚轮及其轨道，不得固定在基础上；",{"key":28,"text":335,"correct":22},"本体上的油枕、冷却器及其连接管道应符合抗震要求；",{"key":31,"text":337,"correct":22},"宜取消滚轮及其轨道，并固定在基础上。",{"id":339,"libraryId":5,"type":118,"typeLabel":119,"stem":340,"options":341,"answer":143,"analysis":33},1034068,"如电缆隧道装设机械通风，一旦发生火灾时，以下机械通风装置的处理措施（ ） 是错误的。 A.报警，延时3min自动关闭； B.报警，人工手动关闭； C可靠地自动关闭； D.报警，继续通风。",[342,343,344,345],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":347,"libraryId":5,"type":118,"typeLabel":119,"stem":348,"options":349,"answer":195,"analysis":33},1034071,"以下措施（ )为电缆实施阻火分隔的安全措施。",[350,352,354,356],{"key":20,"text":351,"correct":22},"实施阻燃防护或阻止延燃；",{"key":24,"text":353,"correct":22},"实施防火构造；",{"key":28,"text":355,"correct":22},"实施耐火防护或选用具有耐火性的电缆；",{"key":31,"text":357,"correct":26},"选用具有难燃性的电缆。",{"id":359,"libraryId":5,"type":118,"typeLabel":119,"stem":360,"options":361,"answer":370,"analysis":33},1034073,"以下漏电保护器的应用方式（）是正确的。 A.漏电保护器作为直接接触防护中基本保护措施的首选保护；",[362,364,366,368],{"key":20,"text":363,"correct":26},"在间接接触防护中，TT系统的电气线路或电气设备优先考虑装设漏电保护器作为 防电击的保护措施；",{"key":24,"text":365,"correct":22},"C在间接接触防护中，与电网的系统接地型式配合，采用自动切断电源的漏电保护器。",{"key":28,"text":367,"correct":22},"为了缩小发生人身电击及接地故障切断电源时引起的停电范围，漏电保护器一般分",{"key":31,"text":369,"correct":22},"两级保护。","BCD",{"id":372,"libraryId":5,"type":118,"typeLabel":119,"stem":373,"options":374,"answer":130,"analysis":33},1034076,"10kV及以下架空线路严禁跨越（ ）。 A.爆炸性气体环境； B.河流； C。火灾危险区城； D.金属屋面厂房。",[375,376,377,378],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":380,"libraryId":5,"type":118,"typeLabel":119,"stem":381,"options":382,"answer":130,"analysis":33},1034079,"以下安全电压的选择和使用方法（ ）是不正确的。",[383,385,387,389],{"key":20,"text":384,"correct":22},"在矿井使用行灯时，采用行灯电压为60V的交流电源；",{"key":24,"text":386,"correct":26},"供给安全电压的特定电源采用独立电源；",{"key":28,"text":388,"correct":22},"当电气设备采用12V安全电压时必须采取防止直接接触带电体的保护措施，但其电 路可不必与大地绝缘；",{"key":31,"text":390,"correct":26},"工作在安全电压下的电路必须与其他电'气系统实行电气上的隔离。",{"id":392,"libraryId":5,"type":118,"typeLabel":119,"stem":393,"options":394,"answer":169,"analysis":33},1034082,"以下措施（ ）属于电气设备防误操作的防误装置的功能。",[395,397,399,401],{"key":20,"text":396,"correct":22},"防止带负荷拉、合隔离开关；",{"key":24,"text":398,"correct":26},"防止带电粉尘进入电气设备中；",{"key":28,"text":400,"correct":22},"防止带接地线（开关）合断路器（隔离开关）；",{"key":31,"text":402,"correct":22},"防止误入带电间隔。",{"id":404,"libraryId":5,"type":118,"typeLabel":119,"stem":405,"options":406,"answer":143,"analysis":33},1034085,"以下条款（ ）符合设计、制造及选用防误装置的原则。",[407,409,411,413],{"key":20,"text":408,"correct":22},"成套的高压开关设备用防误装置，应优先选用机械连锁；",{"key":24,"text":410,"correct":22},"应选用符合产品标准、功能齐全的产品；",{"key":28,"text":412,"correct":26},"防误装置不应配有专用工具（钥匙）进行解锁；",{"key":31,"text":414,"correct":22},"防误装置应不影响开关设备的主要技术性能。",{"id":416,"libraryId":5,"type":118,"typeLabel":119,"stem":417,"options":418,"answer":169,"analysis":33},1034088,"游泳池装设水下照明灯时，下列规定( )是正确的。",[419,421,423,425],{"key":20,"text":420,"correct":22},"灯具的防护等级应为IPX8;",{"key":24,"text":422,"correct":26},"应采用标准电压不超过60V的低压供电；",{"key":28,"text":424,"correct":22},"水下照明灯的安装位置，应保证从灯具上边缘至正常水面不低于0.5m;",{"key":31,"text":426,"correct":22},"对于浸在水中才能安全工作的灯具，应采取低水位断电措施。",{"id":428,"libraryId":5,"type":118,"typeLabel":119,"stem":429,"options":430,"answer":156,"analysis":33},1034091,"狭窄的可导电场所，当采用安全特低电压时，应采用下列措施（ ）之一作为直 接接触保护措施。",[431,433,435,437],{"key":20,"text":432,"correct":22},"采用遮栏或外护物防护，其外壳防护等级不应低于IP2X;",{"key":24,"text":434,"correct":22},"加以绝缘，其耐受试验电压为500V，历时lmin;",{"key":28,"text":436,"correct":26},"采用阻挡物；",{"key":31,"text":438,"correct":26},"置于伸臂范围以外。",{"id":440,"libraryId":5,"type":118,"typeLabel":119,"stem":441,"options":442,"answer":169,"analysis":33},1034094,"数据处理设备正常泄漏电流超过10mA时应采取以下措施（ ）防止电击危险。",[443,445,447,449],{"key":20,"text":444,"correct":22},"提高PE线的强度，防止PE线中断；",{"key":24,"text":446,"correct":26},"装设PE线导电连续性的监測器，当PE线中断时报警；",{"key":28,"text":448,"correct":22},"利用双绕组变压器限制电容泄漏电流的流经范围和路径中断的几率；",{"key":31,"text":450,"correct":22},"当采用单独的PE线时，PE线用铜线的截面不应小于10mm2。",{"id":452,"libraryId":5,"type":118,"typeLabel":119,"stem":453,"options":454,"answer":169,"analysis":33},1034096,"在医院手术室内采取以下防电击措施（ ）是正确的。",[455,457,459,461],{"key":20,"text":456,"correct":22},"采用特低电压时，用电设备的标称电压不应大于AC25或无波纹DC60V;",{"key":24,"text":458,"correct":26},"采用自动切断故障电路保护措施时，在医疗场所内不允许采用TN-S系统；",{"key":28,"text":460,"correct":22},"至少在离患者手术台1.5tn范围内的医疗电气设备应由隔离变压器引出的IT系统供电；",{"key":31,"text":462,"correct":22},"当同一场所尚有来自TN-S或TT系统供电的插座时，医用IT系统的插座应使其他 系统的插座无法插入。",{"id":464,"libraryId":5,"type":118,"typeLabel":119,"stem":465,"options":466,"answer":257,"analysis":33},1034098,"移动式和手提式灯具应采用安全特低电压供电，以下电压值的要求（ ）是正 确的。",[467,469,471,473],{"key":20,"text":468,"correct":22},"在干燥场所不大于50V;",{"key":24,"text":470,"correct":26},"在潮湿场所不大于12V;",{"key":28,"text":472,"correct":26},"在干燥场所不大于36V;",{"key":31,"text":474,"correct":22},"在潮湿场所不大于25V。",{"id":476,"libraryId":5,"type":118,"typeLabel":119,"stem":477,"options":478,"answer":182,"analysis":33},1034101,"在TN-C系统中，以下要求（ ）是符合规范的。",[479,481,483,485],{"key":20,"text":480,"correct":26},"PEN线一般不接入开关设备；",{"key":24,"text":482,"correct":22},"不得装设断开PEN线的任何电器；",{"key":28,"text":484,"correct":26},"不宜断开PEN线；",{"key":31,"text":486,"correct":22},"当需要在PEN线装设电器时，只能相应断开相线回路。",{"id":488,"libraryId":5,"type":118,"typeLabel":119,"stem":489,"options":490,"answer":169,"analysis":33},1034104,"露天或半露天的变电所，不应设置在（ ）。",[491,493,495,497],{"key":20,"text":492,"correct":22},"有腐蚀性气体的场所；",{"key":24,"text":494,"correct":26},"易暴露在雨雪中的场所；",{"key":28,"text":496,"correct":22},"容易沉积可燃粉尘、可燃纤维、灰尘或导电尘埃且严重影响变压器安全运行的场所;",{"key":31,"text":498,"correct":22},"附近有棉、粮及其他易燃、易爆品集中的露天堆场。",{"id":500,"libraryId":5,"type":118,"typeLabel":119,"stem":501,"options":502,"answer":130,"analysis":33},1034107,"以下措施（ ）可作为减少接触电压与跨步电压的措施。",[503,505,507,509],{"key":20,"text":504,"correct":22},"接地网的布置应尽量使电位分布均匀；",{"key":24,"text":506,"correct":26},"设置临时遮拦",{"key":28,"text":508,"correct":22},"增设水平均压带；",{"key":31,"text":510,"correct":26},"带安全帽。",{"id":512,"libraryId":5,"type":118,"typeLabel":119,"stem":513,"options":514,"answer":523,"analysis":33},1034110,"相线对地标称电压为220V的TN系统配电线路的接地故障保护，其切断故障回路的 时间应符合下列（）规定。",[515,517,519,521],{"key":20,"text":516,"correct":26},"配电线路或仅供给固定式电气设备用电的末端线路不宜大于0.8s;",{"key":24,"text":518,"correct":22},"供电给手握式电气设备和移动式电气设备的末端线路或插座回路不应大于0.4s",{"key":28,"text":520,"correct":22},"配电线路或仅供给固定式电气设备用电的末端线路不宜大于5s;",{"key":31,"text":522,"correct":26},"供电给手握式电气设备和移动式电气设备的末端线路或插座回路不应大于5s.","BC",{"id":525,"libraryId":5,"type":118,"typeLabel":119,"stem":526,"options":527,"answer":143,"analysis":33},1034112,"当某6\u002F0.4kV变压器接地型式为TN系统，变压器二次中性点为低压系统接地点， 若配电盘某相与配电盘金属外壳发生短路，且该接地故障为故障点阻抗可忽略不计的金属性 短路时，接地故障回路阻抗包括（ ）。",[528,530,532,534],{"key":20,"text":529,"correct":22},"故障电流所流经的相线阻抗；",{"key":24,"text":531,"correct":22},"故障电流所流经的PE线的阻抗；",{"key":28,"text":533,"correct":26},"电源接地极的接地电阻；",{"key":31,"text":535,"correct":22},"变压器的阻抗。",{"id":537,"libraryId":5,"type":118,"typeLabel":119,"stem":538,"options":539,"answer":195,"analysis":33},1034115,"等电位连接干线的截面应符合下列( )要求。",[540,542,544,546],{"key":20,"text":541,"correct":22},"不应小于该电气装置内最大保护线截面的一半；",{"key":24,"text":543,"correct":22},"不得小于铜导线6mmz;",{"key":28,"text":545,"correct":22},"若使用铜导线其截面不需大于25mm2;",{"key":31,"text":547,"correct":26},"不得小于16mm2。",{"id":549,"libraryId":5,"type":118,"typeLabel":119,"stem":550,"options":551,"answer":560,"analysis":33},1034117,"采用接地故障保护时，在建筑物内应将下列（ ）导电体作总等电位连接。 采用接地故障保护时，在建筑物内应将下列（ ）导电体作总等电位连接。 A. P",[552,554,556,558],{"key":20,"text":553,"correct":22},"PEN 干线；",{"key":24,"text":555,"correct":22},"电气装置接地极的接地干线；",{"key":28,"text":557,"correct":22},"建筑物内的水管、煤气管、采暖和空调管道等金属管道；",{"key":31,"text":559,"correct":22},"条件许可的建筑物金属构件等导电体。","ABCD",{"id":562,"libraryId":5,"type":118,"typeLabel":119,"stem":563,"options":564,"answer":195,"analysis":33},1034120,"下列建筑物内应急照明的照度要求（ ）是正确的。",[565,567,569,571],{"key":20,"text":566,"correct":22},"疏散走道的地面最低氷平照度不应低于0. 5lx；",{"key":24,"text":568,"correct":22},"人员密集场所内的地面最低水平照度不应低于l_51x;",{"key":28,"text":570,"correct":22},"C楼梯间内的地面最低水平照度不应低于5. Olx；",{"key":31,"text":572,"correct":26},"消防控制室、消防水泵站的消防备用照明应保证正常照明照度的70%。",{"id":574,"libraryId":5,"type":118,"typeLabel":119,"stem":575,"options":576,"answer":370,"analysis":33},1034123,"当电压等级为63~llOkV时，下列设备（ ）应装设在有防爆间隔的间隔内。",[577,579,581,583],{"key":20,"text":578,"correct":26},"干式变压器",{"key":24,"text":580,"correct":22},"油浸电压互感器；",{"key":28,"text":582,"correct":22},"屋内断路器;",{"key":31,"text":584,"correct":22},"油浸电流互感",{"id":586,"libraryId":5,"type":118,"typeLabel":119,"stem":587,"options":588,"answer":156,"analysis":33},1034126,"以下措施（）是直接接触防护的正确措施。",[589,591,593,595],{"key":20,"text":590,"correct":22},"带电部分的绝缘，用以防止与带电部分的任何接触；",{"key":24,"text":592,"correct":22},"遮拦或外护物用以防止与带电部分的任何接触；",{"key":28,"text":594,"correct":26},"阻挡物用以防止无意地触及带电部分，并能防止故意绕过阻挡物有意识地触及带电 部分；",{"key":31,"text":596,"correct":26},"当回路设备中发生带电部分与外露可导电部分之间的故障时，应在k内自动切断提 供该设备的电源。",{"id":598,"libraryId":5,"type":118,"typeLabel":119,"stem":599,"options":600,"answer":370,"analysis":33},1034129,"配电网的负荷率是指平均负载功率与最大负载功率之比。以下关于调整负荷率实现 节电降损的描述（）是正确的。",[601,603,605,607],{"key":20,"text":602,"correct":26},"负荷率越低标志负荷曲线波动越小；",{"key":24,"text":604,"correct":22},"负荷率越高表明负荷波动越接近平均值",{"key":28,"text":606,"correct":22},"提高负荷率，可降低线损；",{"key":31,"text":608,"correct":22},"提高负荷率节电降损的实质是调整变压器的负荷曲线，使之接近平稳。",{"id":610,"libraryId":5,"type":118,"typeLabel":119,"stem":611,"options":612,"answer":169,"analysis":33},1034131,"以下措施（）为电气设备防电磁干扰所采取的正确措施.",[613,615,617,619],{"key":20,"text":614,"correct":22},"考虑敏感设备与潜在干扰源的相对位置；",{"key":24,"text":616,"correct":26},"在装有敏感设备的电气装置中必须采用TN-C系统；",{"key":28,"text":618,"correct":22},"适当安排布线，（电缓）的敷设路径以使由供电电缆和信号电缆的共同环路的范围减 至最低限度；",{"key":31,"text":620,"correct":22},"考虑金属外护物的等电位联结和屏蔽。",[622,625,628,631,634,637],{"id":15,"name":623,"category":7,"favorite":624},"领导干部任职前廉政法规知识测试题",92,{"id":626,"name":627,"category":7,"favorite":15},595,"建筑结构与设备",{"id":629,"name":630,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":632,"name":633,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":635,"name":636,"category":7,"favorite":8},534,"BIM工程师",{"id":638,"name":636,"category":7,"favorite":8},535]