[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":602},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,27,50,2321,[13,34,46,58,70,82,93,105,117,129,137,146,158,170,181,193,205,217,229,241,253,265,277,289,299,311,323,334,346,358,365,377,389,401,413,425,437,449,460,472,483,495,507,519,531,543,555,567,578,590],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1033728,1,"单选题","某工程选用一套设备，根据工艺要求其驱动拟采用一台交流电动机，工作方式为恒 定负荷连续运行。机械工艺参数为：负载转矩为1447N * m，启动过程中的最大静阻转矩为 562N * m,要求电动机的转速为2900~3000r\u002Fmin，传动机械折算到电动机轴上的总飞轮矩 GD2为1962N * m2。现初选一台交流鼠笼型电动机，其最小启动转矩为1171N * m,平均启 动转矩为2337N*m，电动机转子飞轮矩为441N * m2，包括电动机在内的整个传动系统所 允许的最大飞轮转矩为3826N* m2 (折算到电动机轴），电动机拟采用全压启动。请进行电 动机的有关参数及效验计算。 . 工作方式为恒定负荷连续运行的电动机，属于（ ）工作制。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","S9；",false,{"key":24,"text":25,"correct":22},"B","S7；",{"key":27,"text":28,"correct":22},"C","S2；",{"key":30,"text":31,"correct":32},"D","S1。",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1033730,"某工程选用一套设备，根据工艺要求其驱动拟采用一台交流电动机，工作方式为恒 定负荷连续运行。机械工艺参数为：负载转矩为1447N * m，启动过程中的最大静阻转矩为 562N * m,要求电动机的转速为2900~3000r\u002Fmin，传动机械折算到电动机轴上的总飞轮矩 GD2为1962N * m2。现初选一台交流鼠笼型电动机，其最小启动转矩为1171N * m,平均启 动转矩为2337N*m，电动机转子飞轮矩为441N * m2，包括电动机在内的整个传动系统所 允许的最大飞轮转矩为3826N* m2 (折算到电动机轴），电动机拟采用全压启动。请进行电 动机的有关参数及效验计算。 . —般情况下对于工作方式为恒定负荷连续运行的笼型电动机或同步电动机的容量校 验，以下（ ）项目是不需要做的。",[38,40,42,44],{"key":20,"text":39,"correct":22},"按启动时最小转矩校验电动机的额定功率；",{"key":24,"text":41,"correct":32},"电动机过载能力校验；",{"key":27,"text":43,"correct":22},"按允许的最大飞轮矩校验电动机的额定功率；",{"key":30,"text":45,"correct":22},"计算所需的负载功率，校验所选择电动机的额定功率。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1033733,"某工程选用一套设备，根据工艺要求其驱动拟采用一台交流电动机，工作方式为恒 定负荷连续运行。机械工艺参数为：负载转矩为1447N * m，启动过程中的最大静阻转矩为 562N * m,要求电动机的转速为2900~3000r\u002Fmin，传动机械折算到电动机轴上的总飞轮矩 GD2为1962N * m2。现初选一台交流鼠笼型电动机，其最小启动转矩为1171N * m,平均启 动转矩为2337N*m，电动机转子飞轮矩为441N * m2，包括电动机在内的整个传动系统所 允许的最大飞轮转矩为3826N* m2 (折算到电动机轴），电动机拟采用全压启动。请进行电 动机的有关参数及效验计算。 .",[50,52,54,56],{"key":20,"text":51,"correct":22},"该电动机按轴功率确定额定功率应最接近（）。",{"key":24,"text":53,"correct":32},"750kW；",{"key":27,"text":55,"correct":22},"460kW; C 320kW；",{"key":30,"text":57,"correct":22},"180kW",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},1033736,"某工程选用一套设备，根据工艺要求其驱动拟采用一台交流电动机，工作方式为恒 定负荷连续运行。机械工艺参数为：负载转矩为1447N * m，启动过程中的最大静阻转矩为 562N * m,要求电动机的转速为2900~3000r\u002Fmin，传动机械折算到电动机轴上的总飞轮矩 GD2为1962N * m2。现初选一台交流鼠笼型电动机，其最小启动转矩为1171N * m,平均启 动转矩为2337N*m，电动机转子飞轮矩为441N * m2，包括电动机在内的整个传动系统所 允许的最大飞轮转矩为3826N* m2 (折算到电动机轴），电动机拟采用全压启动。请进行电 动机的有关参数及效验计算。 . 为保证启动时有足够加速转矩的系数取1.25,全压启动时电压波动系数取0.85， 试计算初选电动机在全压启动时最小转矩应最接近（ ）N *m。电动机（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"828,能通过最小启动转矩效验；",{"key":24,"text":65,"correct":22},"702,能通过最小启动转矩效验；",{"key":27,"text":67,"correct":32},"972.3,能通过最小启动转矩效验；",{"key":30,"text":69,"correct":22},"450，不能通过最小启动转矩效验。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},1033739,"某工程选用一套设备，根据工艺要求其驱动拟采用一台交流电动机，工作方式为恒 定负荷连续运行。机械工艺参数为：负载转矩为1447N * m，启动过程中的最大静阻转矩为 562N * m,要求电动机的转速为2900~3000r\u002Fmin，传动机械折算到电动机轴上的总飞轮矩 GD2为1962N * m2。现初选一台交流鼠笼型电动机，其最小启动转矩为1171N * m,平均启 动转矩为2337N*m，电动机转子飞轮矩为441N * m2，包括电动机在内的整个传动系统所 允许的最大飞轮转矩为3826N* m2 (折算到电动机轴），电动机拟采用全压启动。请进行电 动机的有关参数及效验计算。 . 初选的电动机允许的最大飞轮矩为（ > N *m2，所选用电动机（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":32},"2112,可通过最大飞轮转矩校验；",{"key":24,"text":77,"correct":22},"2553，不可通过最大飞轮转矩校验",{"key":27,"text":79,"correct":22},"2464,可通过最大飞轮转矩校验；",{"key":30,"text":81,"correct":22},"833，不可通过最大飞轮转矩校验。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},1033740,"某车间有一台设备每次运行时间为15min,机械最大阻力矩为44.1N * m,欲选用 一台短时工作制的异步电动机电动机与之配套。现有一台电动机负荷暂载率为25%时额 定转矩为23.8N.m，最大转矩为额定转矩的2. 6倍。试计算该电动机的过载能力是否能 通过有关校验。 该设备电动机属于下列（ ）工作制。",[86,88,90,91],{"key":20,"text":87,"correct":22},"Sl；",{"key":24,"text":89,"correct":22},"S4；",{"key":27,"text":28,"correct":32},{"key":30,"text":92,"correct":22},"S6。",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":24,"analysis":33},1033743,"某车间有一台设备每次运行时间为15min,机械最大阻力矩为44.1N * m,欲选用 一台短时工作制的异步电动机电动机与之配套。现有一台电动机负荷暂载率为25%时额 定转矩为23.8N.m，最大转矩为额定转矩的2. 6倍。试计算该电动机的过载能力是否能 通过有关校验。",[97,99,101,103],{"key":20,"text":98,"correct":22},"待选的电动机最大允许转矩最接近（ ）。",{"key":24,"text":100,"correct":32},"61. 88N *m；",{"key":27,"text":102,"correct":22},"46. 41N * m； C 32. 82N * m；",{"key":30,"text":104,"correct":22},"30. 94N * m。",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":24,"analysis":33},1033746,"某车间有一台设备每次运行时间为15min,机械最大阻力矩为44.1N * m,欲选用 一台短时工作制的异步电动机电动机与之配套。现有一台电动机负荷暂载率为25%时额 定转矩为23.8N.m，最大转矩为额定转矩的2. 6倍。试计算该电动机的过载能力是否能 通过有关校验。 下列判断待选用的电动机是否能通过过载能力校验的结论正确的是（ ）。",[109,111,113,115],{"key":20,"text":110,"correct":22},"电动机最大允许转矩>0.5倍机械最大阻力矩，过载能力校验通过；",{"key":24,"text":112,"correct":32},"电动机最大允许转矩>机械最大阻力矩，过载能力校验通过；",{"key":27,"text":114,"correct":22},"C电动机最大允许转矩",{"key":30,"text":116,"correct":22},"电动机最大允许转矩",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":20,"analysis":33},1033749,"在工程设计中通常根据生产机械的负荷类型及工作制选用不同的电动机与之配套。 生产机械的负载转矩T随转矩n而变化的特性T = f(n)称为负载特性，图14-14中四组曲 线为不同生产机械的负载曲线。 有一种机械负载，在任何转速下转矩T总保持恒定或大致恒定，转矩T的极性随转速方向的改变而改变，总是起反阻转矩的作用。图14-14中（ ）为表示这种负荷的负 载曲线。",[121,123,125,127],{"key":20,"text":122,"correct":32},"(a)；",{"key":24,"text":124,"correct":22},"(b);",{"key":27,"text":126,"correct":22},"(c);",{"key":30,"text":128,"correct":22},"(d)。",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":30,"analysis":33},1033752,"在工程设计中通常根据生产机械的负荷类型及工作制选用不同的电动机与之配套。 生产机械的负载转矩T随转矩n而变化的特性T = f(n)称为负载特性，图14-14中四组曲 线为不同生产机械的负载曲线。 有一种机械负载，负载转矩T与转速n成反比，阻转矩大，转速低；阻转矩小， 转速高。图14-14中（ 〉为表示这种负荷的负载曲线。",[133,134,135,136],{"key":20,"text":122,"correct":22},{"key":24,"text":124,"correct":22},{"key":27,"text":126,"correct":22},{"key":30,"text":128,"correct":32},{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":27,"analysis":33},1033755,"在工程设计中通常根据生产机械的负荷类型及工作制选用不同的电动机与之配套。 生产机械的负载转矩T随转矩n而变化的特性T = f(n)称为负载特性，图14-14中四组曲 线为不同生产机械的负载曲线。 风机、水泵负载，随叶轮的转动，介质对叶片的阻力在一定转速范围内大致与转速 n的平方成正比。图14-14中（ ）为表示风机、水泵负荷的负载曲线。",[141,143,144,145],{"key":20,"text":142,"correct":22},"(a);",{"key":24,"text":124,"correct":22},{"key":27,"text":126,"correct":32},{"key":30,"text":128,"correct":22},{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":30,"analysis":33},1033758,"该鼠笼型电动机的额定容量为（ ）（选最接近的一个数据)。",[150,152,154,156],{"key":20,"text":151,"correct":22},"148. 8kVA；",{"key":24,"text":153,"correct":22},"172. 5kVA;",{"key":27,"text":155,"correct":22},"179.8kVA；",{"key":30,"text":157,"correct":32},"193. 3kVA,",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":20,"analysis":33},1033759,"电动机全压启动时母线电压相对值为（ ），电动机（ ）。",[162,164,166,168],{"key":20,"text":163,"correct":32},"0. 873,满足母线压降允许值的要求；",{"key":24,"text":165,"correct":22},"0.873,不满足母线压降允许值的要求；",{"key":27,"text":167,"correct":22},"0.979,满足母线压降允许伹的要求；",{"key":30,"text":169,"correct":22},"0.754，不满足母线压降允许值的要求。",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":172,"answer":20,"analysis":33},1033762,[173,175,177,179],{"key":20,"text":174,"correct":32},"电动机全压启动时电动机端子电压相对值为（ ）。",{"key":24,"text":176,"correct":22},"0.798; E 0.795",{"key":27,"text":178,"correct":22},"0.826;",{"key":30,"text":180,"correct":22},"0.850。",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":27,"analysis":33},1033765,"预接负荷的无功功率为（）（选最接近的一个数据)。",[185,187,189,191],{"key":20,"text":186,"correct":22},"144kvar；",{"key":24,"text":188,"correct":22},"179kvar;",{"key":27,"text":190,"correct":32},"240kvar；",{"key":30,"text":192,"correct":22},"320kvar。",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":27,"analysis":33},1033768,"电动机全压启动时母线电压相对值为（ ）（选最接近的一个数据)。",[197,199,201,203],{"key":20,"text":198,"correct":22},"0.756;",{"key":24,"text":200,"correct":22},"0.843;",{"key":27,"text":202,"correct":32},"0.908;",{"key":30,"text":204,"correct":22},"0.927。",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":20,"analysis":33},1033771,"该交流电动机全压起动时电动机端子电压相对值为（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":32},"0. 822；",{"key":24,"text":212,"correct":22},"0.803;",{"key":27,"text":214,"correct":22},"0.775;",{"key":30,"text":216,"correct":22},"0.756。",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":30,"analysis":33},1033774,"某工厂有一台同步电动机，电气参数为：额定功率1250kW,额定电压交流三相 6kV,额定电流0.144kA,额定启动电流倍数6倍，电动机启动转矩与额定转矩之比为 1.1, 6kV母线短路容量为40MVA,母线上预接负荷的无功功率为1Mvar,要求启动时母 线电压不低于额定电压的85%。选择启动方式和计算启动的有关参数。 验算全压启动时6kV母线电压相对值为（ ），判断（ ）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"0.87，可以采用全压启动；",{"key":24,"text":224,"correct":22},"0.87，不能采用全压启动；",{"key":27,"text":226,"correct":22},"0. 82,可以采用全压启动；",{"key":30,"text":228,"correct":32},"0.82,不能采用全压启动。",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":30,"analysis":33},1033777,"某工厂有一台同步电动机，电气参数为：额定功率1250kW,额定电压交流三相 6kV,额定电流0.144kA,额定启动电流倍数6倍，电动机启动转矩与额定转矩之比为 1.1, 6kV母线短路容量为40MVA,母线上预接负荷的无功功率为1Mvar,要求启动时母 线电压不低于额定电压的85%。选择启动方式和计算启动的有关参数。 电缆或导线的线路电抗忽略不计，试计算采用启动电抗器并满足启动要求时每相电 抗器额定电抗值最小为（ ）（选最接近的一个数据)。",[233,235,237,239],{"key":20,"text":234,"correct":22},"1. 6Ω；",{"key":24,"text":236,"correct":22},"0.16Ω;",{"key":27,"text":238,"correct":22},"9. 7 Ω；",{"key":30,"text":240,"correct":32},"0. 97 Ω",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":24,"analysis":33},1033780,"某工厂有一台同步电动机，电气参数为：额定功率1250kW,额定电压交流三相 6kV,额定电流0.144kA,额定启动电流倍数6倍，电动机启动转矩与额定转矩之比为 1.1, 6kV母线短路容量为40MVA,母线上预接负荷的无功功率为1Mvar,要求启动时母 线电压不低于额定电压的85%。选择启动方式和计算启动的有关参数。 现有待选启动电抗器设备若干种，其每相额定电抗值的参数有10.7、5.7、3.3、 1.8、1.05、0.6、0.35Ω七种，最适合本题中要选的启动电抗器每相额定电抗值为（ ）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"10. 7Ω;",{"key":24,"text":248,"correct":32},"1. 05Ω;",{"key":27,"text":250,"correct":22},"1. 8Ω；",{"key":30,"text":252,"correct":22},"0. 35Ω。",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":20,"analysis":33},1033781,"某工厂有一台同步电动机，电气参数为：额定功率1250kW，额定电压交流三相 6kV,额定启动容量为9MV A，电动机启动转矩与额定转矩之比为1.1，生产机械的静阻转 矩为0.3，采用电抗器降压启动，启动电抗器每相额定电抗值为1.05Ω。6kV母线短路容量 为40MV A，母线上预接负荷的无功功率为lMvar，要求启动时母线电压不低于额定电压的 85％。电缆或导线的线路电抗忽略不计。请选择启动电抗器参数。 电动机采用电抗器降压启动时母线电压相对值为（ ），判断（ ）。",[257,259,261,263],{"key":20,"text":258,"correct":32},"0.852、满足母线压降允许值的要求；",{"key":24,"text":260,"correct":22},"0.95、满足母线压降允许值的要求；",{"key":27,"text":262,"correct":22},"0.742、不满足母线压降允许值的要求；",{"key":30,"text":264,"correct":22},"0.806、不满足母线压降允许值的要求。",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":27,"analysis":33},1033784,"某工厂有一台同步电动机，电气参数为：额定功率1250kW，额定电压交流三相 6kV,额定启动容量为9MV A，电动机启动转矩与额定转矩之比为1.1，生产机械的静阻转 矩为0.3，采用电抗器降压启动，启动电抗器每相额定电抗值为1.05Ω。6kV母线短路容量 为40MV A，母线上预接负荷的无功功率为lMvar，要求启动时母线电压不低于额定电压的 85％。电缆或导线的线路电抗忽略不计。请选择启动电抗器参数。",[269,271,273,275],{"key":20,"text":270,"correct":22},"采用电抗器降压启动时，同步电动机端子电压相对值为（ ）。",{"key":24,"text":272,"correct":22},"0. 589；",{"key":27,"text":274,"correct":32},"0. 639, C 0.675;",{"key":30,"text":276,"correct":22},"0. 754.",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":20,"analysis":33},1033787,"某工厂有一台同步电动机，电气参数为：额定功率1250kW，额定电压交流三相 6kV,额定启动容量为9MV A，电动机启动转矩与额定转矩之比为1.1，生产机械的静阻转 矩为0.3，采用电抗器降压启动，启动电抗器每相额定电抗值为1.05Ω。6kV母线短路容量 为40MV A，母线上预接负荷的无功功率为lMvar，要求启动时母线电压不低于额定电压的 85％。电缆或导线的线路电抗忽略不计。请选择启动电抗器参数。 经电抗器降压后，同步电动机能提供传动机械的启动转矩为（ ）。判断采用电 抗器降压启动后，机组（ ）。",[281,283,285,287],{"key":20,"text":282,"correct":32},"0.456，能保证机组启动；",{"key":24,"text":284,"correct":22},"0.398，能保证机组启动；",{"key":27,"text":286,"correct":22},"0.369，不能保证机组启动；",{"key":30,"text":288,"correct":22},"0.256,不能保证机组启动。",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":27,"analysis":33},1033789,"某工厂有一台同步电动机，电气参数为：额定功率1250kW，额定电压交流三相 6kV,额定启动容量为9MV A，电动机启动转矩与额定转矩之比为1.1，生产机械的静阻转 矩为0.3，采用电抗器降压启动，启动电抗器每相额定电抗值为1.05Ω。6kV母线短路容量 为40MV",[293,295,297,298],{"key":20,"text":294,"correct":22},"母线上预接负荷的无功功率为lMvar，要求启动时母线电压不低于额定电压的 85％。电缆或导线的线路电抗忽略不计。请选择启动电抗器参数。",{"key":24,"text":296,"correct":22},"由设备手册上查得以下设备参数见表14-5,请选择最适合本题条件启动电流 ( )、电抗器每相额定电抗（ ）的启动电抗器。",{"key":27,"text":33,"correct":32},{"key":30,"text":33,"correct":22},{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":24,"analysis":33},1033791,"某工厂有一台同步电动机，电气参数为：额定功率1250kW,额定电压交流三相 6KV，额定转速375r\u002Fmin,该同步电动机的启动平均转矩与额定转矩之比为1.1,同步机机组的总飞轮转矩GD2为8Mg * m2，同步电动机阻尼笼中阻尼条的铜质量36. 4kg,启动过程 中生产机械的平均阻转矩为0.3，采用电抗器降压启动，启动电抗器每相额定电抗值为 1.05Ω，电抗器允许启动电流为750A。电抗器降压启动时：同步电动机端子电压相对值为 0.67,母线电压相对值为0.852,启动回路输入容量为7. 13MVA。试计算该同步电动机采 用电抗器降压启动时的有关参数。采用电抗器降压启动时，该同步机的启动时间为（ ）(选最接近的一个数据）。",[303,305,307,309],{"key":20,"text":304,"correct":22},"16. 5s",{"key":24,"text":306,"correct":32},"12. 7s",{"key":27,"text":308,"correct":22},"10. 36s；",{"key":30,"text":310,"correct":22},"8. Ols",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":30,"analysis":33},1033793,"某工厂有一台同步电动机，电气参数为：额定功率1250kW,额定电压交流三相 6KV，额定转速375r\u002Fmin,该同步电动机的启动平均转矩与额定转矩之比为1.1,同步机机组的总飞轮转矩GD2为8Mg * m2，同步电动机阻尼笼中阻尼条的铜质量36. 4kg,启动过程 中生产机械的平均阻转矩为0.3，采用电抗器降压启动，启动电抗器每相额定电抗值为 1.05Ω，电抗器允许启动电流为750A。电抗器降压启动时：同步电动机端子电压相对值为 0.67,母线电压相对值为0.852,启动回路输入容量为7. 13MVA。试计算该同步电动机采 用电抗器降压启动时的有关参数。为了保证同步电动机在冷却状态下连续启动2次时，铜制阻尼笼温度不超300。C, 该同步电动机允许的最长启动时间为（）（选最接近的一个数据）。",[315,317,319,321],{"key":20,"text":316,"correct":22},"10.3s;",{"key":24,"text":318,"correct":22},"11.9s；",{"key":27,"text":320,"correct":22},"12.8s;",{"key":30,"text":322,"correct":32},"13. 9s.",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":20,"analysis":33},1033794,"某工厂有一台同步电动机，电气参数为：额定功率1250kW,额定电压交流三相 6KV，额定转速375r\u002Fmin,该同步电动机的启动平均转矩与额定转矩之比为1.1,同步机机组的总飞轮转矩GD2为8Mg * m2，同步电动机阻尼笼中阻尼条的铜质量36. 4kg,启动过程 中生产机械的平均阻转矩为0.3，采用电抗器降压启动，启动电抗器每相额定电抗值为 1.05Ω，电抗器允许启动电流为750A。电抗器降压启动时：同步电动机端子电压相对值为 0.67,母线电压相对值为0.852,启动回路输入容量为7. 13MVA。试计算该同步电动机采 用电抗器降压启动时的有关参数。按在冷却状态下同步电动机连续启动2次，验算启动电抗器的过负荷能力是否符合 要求，下列结论正确的是（ ）。",[327,329,331,332],{"key":20,"text":328,"correct":32},"0.124kA",{"key":24,"text":330,"correct":22},"0. 585kA",{"key":27,"text":328,"correct":22},{"key":30,"text":333,"correct":22},"1.168kA>0.750kA,启动器过负荷能力不符合要求.",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":24,"analysis":33},1033796,"为平稳启动过跨运输车电动机允许的最低启动电压为（ ）（选最接近的一个数 据)。",[338,340,342,344],{"key":20,"text":339,"correct":22},"245V；",{"key":24,"text":341,"correct":32},"309V；",{"key":27,"text":343,"correct":22},"323V；",{"key":30,"text":345,"correct":22},"361V。",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":30,"analysis":33},1033798,"平稳启动过跨运输车时电动机的启动阻抗为（ ）（选最接近的一个数据)。",[350,352,354,356],{"key":20,"text":351,"correct":22},"0. 468Ω；",{"key":24,"text":353,"correct":22},"0. 414Ω；",{"key":27,"text":355,"correct":22},"3. 38Ω；",{"key":30,"text":357,"correct":32},"2.39Ω。",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":360,"answer":27,"analysis":33},1033800,[361,362,363,364],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":22},{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":27,"analysis":33},1033804,"由供电母线到过跨运输车电动机的线路电阻为a oin,按符合平稳启动要求的最低 电压启动过跨运输车时外加降压电阻为（ ）（选最接近的一个数据）。",[369,371,373,375],{"key":20,"text":370,"correct":22},"0. 08Ω；",{"key":24,"text":372,"correct":22},"0. 62Ω；",{"key":27,"text":374,"correct":32},"1. 2lΩ；",{"key":30,"text":376,"correct":22},"1. 23Ω。",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":27,"analysis":33},1033807,"某轧钢车间有一台额定功率1450kW,额定转速500r\u002Fmin的轧钢同步电动机，电动 机的额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启 动转矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46MVA。启动前母线电压 为額定电压6kV，母线上的无功负载为2. 95Mvar。启动时母线允许电压标幺值为0.85。机 组的静阻转矩标幺值为0. 16。试判断电抗器降压启动方案的可行性及计算有关参数。 根据等效电路，按母线电压水平核算此电动机采用电抗器启动时，与母线允许电压 标幺值有关的计算系数为（）。",[381,383,385,387],{"key":20,"text":382,"correct":22},"1.24；",{"key":24,"text":384,"correct":22},"5.25;",{"key":27,"text":386,"correct":32},"7.00;",{"key":30,"text":388,"correct":22},"10.0。",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":30,"analysis":33},1033810,"某轧钢车间有一台额定功率1450kW,额定转速500r\u002Fmin的轧钢同步电动机，电动 机的额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启 动转矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46MVA。启动前母线电压 为額定电压6kV，母线上的无功负载为2. 95Mvar。启动时母线允许电压标幺值为0.85。机 组的静阻转矩标幺值为0. 16。试判断电抗器降压启动方案的可行性及计算有关参数。 采用电抗器启动时，为保证启动时母线电压降不大于15%，启动时电机机端电压 标幺值不能小于（ ）（选最接近的一个数据)。",[393,395,397,399],{"key":20,"text":394,"correct":22},"1.12;",{"key":24,"text":396,"correct":22},"0.85;",{"key":27,"text":398,"correct":22},"0. 50；",{"key":30,"text":400,"correct":32},"0.42。",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":24,"analysis":33},1033812,"某轧钢车间有一台额定功率1450kW,额定转速500r\u002Fmin的轧钢同步电动机，电动 机的额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启 动转矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46MVA。启动前母线电压 为額定电压6kV，母线上的无功负载为2. 95Mvar。启动时母线允许电压标幺值为0.85。机 组的静阻转矩标幺值为0. 16。试判断电抗器降压启动方案的可行性及计算有关参数。 根据同步电动机启动时的等效电路，用电抗器降压启动条件的不等式，验算本台电 机（ ）（选最接近的一个数据)。",[405,407,409,411],{"key":20,"text":406,"correct":22},"4.37〉2. 8，不可以采用电抗器降压启动；",{"key":24,"text":408,"correct":32},"4. 37〉2. 8，可以采用电抗器降压启动；",{"key":27,"text":410,"correct":22},"17.5>3. 48，不可以采用电抗器降压启动；",{"key":30,"text":412,"correct":22},"17. 5>3. 48,可以采用电抗器降压启动。",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":27,"analysis":33},1033815,"某轧钢车间有一台额定功率1450kW,额定转速500r\u002Fmin的轧钢同步电动机，电动 机的额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启 动转矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46MVA。启动前母线电压 为額定电压6kV，母线上的无功负载为2. 95Mvar。启动时母线允许电压标幺值为0.85。机 组的静阻转矩标幺值为0. 16。试判断电抗器降压启动方案的可行性及计算有关参数。 计算降压启动电抗器的电抗值时计算系数γ 为（ ）（选最接近的一个数据)。",[417,419,421,423],{"key":20,"text":418,"correct":22},"6.67;",{"key":24,"text":420,"correct":22},"4. 21",{"key":27,"text":422,"correct":32},"5.67;",{"key":30,"text":424,"correct":22},"0.85。",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":24,"analysis":33},1033817,"某轧钢车间有一台额定功率1450kW,额定转速500r\u002Fmin的轧钢同步电动机，电动 机的额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启 动转矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46MVA。启动前母线电压 为額定电压6kV，母线上的无功负载为2. 95Mvar。启动时母线允许电压标幺值为0.85。机 组的静阻转矩标幺值为0. 16。试判断电抗器降压启动方案的可行性及计算有关参数。 降压启动电抗器的电抗值为（）。",[429,431,433,435],{"key":20,"text":430,"correct":22},"0.169Ω;",{"key":24,"text":432,"correct":32},"0. 96Ω;",{"key":27,"text":434,"correct":22},"1. 69Ω;",{"key":30,"text":436,"correct":22},"9. 6Ω。",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":24,"analysis":33},1033819,"某轧钢车间有一台额定功率l450kW，额定转速500r\u002Fmin的轧钢电动机，电动机的 额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启动转 矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46 MVA。启动前母线电压为 额定电压6kV，母线上的无功负载为2. 95Mvar,启动时母线允许电压标幺值为0. 85。机组 的静阻转矩标么值为0.16。试选择启动方式，计算有关参数。 按母线电压水平核算此电动机是否允许直接启动时，与母线允许电压标幺值有关的计算系数α为（），该电动机（）。",[441,443,445,447],{"key":20,"text":442,"correct":22},"0.11，不允许全压直接启动；",{"key":24,"text":444,"correct":32},"0.176，不允许全压直接启动；",{"key":27,"text":446,"correct":22},"0.25,允许全压直接启动；",{"key":30,"text":448,"correct":22},"0.85，允许全压直接启动。",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":24,"analysis":33},1033822,"某轧钢车间有一台额定功率l450kW，额定转速500r\u002Fmin的轧钢电动机，电动机的 额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启动转 矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46 MVA。启动前母线电压为 额定电压6kV，母线上的无功负载为2. 95Mvar,启动时母线允许电压标幺值为0. 85。机组 的静阻转矩标么值为0.16。试选择启动方式，计算有关参数。 按母线电压水平核算此电动机采用自耦变压器启动时，与母线允许电压标幺值有关 的计算系数δ为（）（选最接近的一个数据)。",[453,455,457,459],{"key":20,"text":454,"correct":22},"0.09;",{"key":24,"text":456,"correct":32},"0.128;",{"key":27,"text":458,"correct":22},"0.16;",{"key":30,"text":424,"correct":22},{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":27,"analysis":33},1033824,"某轧钢车间有一台额定功率l450kW，额定转速500r\u002Fmin的轧钢电动机，电动机的 额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启动转 矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46 MVA。启动前母线电压为 额定电压6kV，母线上的无功负载为2. 95Mvar,启动时母线允许电压标幺值为0. 85。机组 的静阻转矩标么值为0.16。试选择启动方式，计算有关参数。 根据同步电动机启动时的等效电路，用自耦变压器降压启动条件的不等式，验算本 台电机（ ）（选最接近的一个数据).",[464,466,468,470],{"key":20,"text":465,"correct":22},"0. 559>0.176，不可以采用自耦变压器降压启动；",{"key":24,"text":467,"correct":22},"0. 935>0. 392,不可以采用自耦变压器降压启动；",{"key":27,"text":469,"correct":32},"0. 559>0.176,可以采用自耦变压器降压启动；",{"key":30,"text":471,"correct":22},"0. 935>0. 392,可以采用自耦变压器降压启动。",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":24,"analysis":33},1033827,"某轧钢车间有一台额定功率l450kW，额定转速500r\u002Fmin的轧钢电动机，电动机的 额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启动转 矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46 MVA。启动前母线电压为 额定电压6kV，母线上的无功负载为2. 95Mvar,启动时母线允许电压标幺值为0. 85。机组 的静阻转矩标么值为0.16。试选择启动方式，计算有关参数。 采用自耦变压器启动时，为保证启动时母线电压降不大于15%，自耦变压器的变 比应大于（ )(选最接近的一个数据）。",[476,477,479,481],{"key":20,"text":396,"correct":22},{"key":24,"text":478,"correct":32},"0.49;",{"key":27,"text":480,"correct":22},"0.32;",{"key":30,"text":482,"correct":22},"0.15。",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":30,"analysis":33},1033830,"某轧钢车间有一台额定功率l450kW，额定转速500r\u002Fmin的轧钢电动机，电动机的 额定电压为6kV,额定容量为1.9MVA,额定启动电流倍数为5. 9倍，额定电压下启动转 矩标幺值为1。变电所6kV、50Hz母线上的最小短路容量为46 MVA。启动前母线电压为 额定电压6kV，母线上的无功负载为2. 95Mvar,启动时母线允许电压标幺值为0. 85。机组 的静阻转矩标么值为0.16。试选择启动方式，计算有关参数。 计算该电动机降压启动的自耦变压器变比（ ）（选最接近的一个数据）。",[487,489,491,493],{"key":20,"text":488,"correct":22},"0.745;",{"key":24,"text":490,"correct":22},"1.05;",{"key":27,"text":492,"correct":22},"0.693;",{"key":30,"text":494,"correct":32},"0.877。",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":24,"analysis":33},1033833,"某机械设备配用一台绕线型异步电动机，其额定功率60kW，额定转速590r\u002Fmin， 转子额定电压330V,转子额定电流112 A，试计算该电动机有关参数。 该电动机转子额定电阻为（ ）（选最接近的一个数据）。",[499,501,503,505],{"key":20,"text":500,"correct":22},"0. 98Ω；",{"key":24,"text":502,"correct":32},"1. 70Ω；",{"key":27,"text":504,"correct":22},"2. 95Ω;",{"key":30,"text":506,"correct":22},"5.13Ω。",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":20,"analysis":33},1033835,"某机械设备配用一台绕线型异步电动机，其额定功率60kW，额定转速590r\u002Fmin， 转子额定电压330V,转子额定电流112 A，试计算该电动机有关参数。 该绕线型异步电动机的额定转差率为（ ）（选最接近的一个数据）。",[511,513,515,517],{"key":20,"text":512,"correct":32},"0.0167；",{"key":24,"text":514,"correct":22},"0.0333；",{"key":27,"text":516,"correct":22},"0.0500;",{"key":30,"text":518,"correct":22},"0.0667。",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":24,"analysis":33},1033838,"某机械设备配用一台绕线型异步电动机，其额定功率60kW，额定转速590r\u002Fmin， 转子额定电压330V,转子额定电流112 A，试计算该电动机有关参数。 若转子导线长30m,转子导线电阻为0.0102Ω,求转子导线电阻标幺值为（ ） (选最接近的一个数据)。",[523,525,527,529],{"key":20,"text":524,"correct":22},"0.002；",{"key":24,"text":526,"correct":32},"0. 006;",{"key":27,"text":528,"correct":22},"0.02;",{"key":30,"text":530,"correct":22},"0. 06。",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":20,"analysis":33},1033839,"某机械设备配用一台绕线型异步电动机，其额定功率60kW，额定转速590r\u002Fmin， 转子额定电压330V,转子额定电流112 A，试计算该电动机有关参数。 转子导线电阻计算在内，该绕线型异步电动机的等效转差率为（ ）（选最接近 的一个数据)。",[535,537,539,541],{"key":20,"text":536,"correct":32},"0. 0227,",{"key":24,"text":538,"correct":22},"0.0187;",{"key":27,"text":540,"correct":22},"0.0177；",{"key":30,"text":542,"correct":22},"0.0173。",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":27,"analysis":33},1033842,"某机械设备配用一台绕线型异步电动机，其额定功率90kW，额定转速589r\u002Fmin， 转子额定电压330V,转子额定电流166. 6A。电动机的最大转矩标幺值为3.1，计算最大启 , 动转矩的系数取0.8。现决定采用对称切除三级电阻启动。试用分析法求各级启动电阻值。 (转子导线电阻忽略不计。） 该绕线型异步电动机的同步速为（ ）。",[547,549,551,553],{"key":20,"text":548,"correct":22},"3000r\u002Fmin；",{"key":24,"text":550,"correct":22},"1500r\u002Fmin；",{"key":27,"text":552,"correct":32},"600r\u002Fmin；",{"key":30,"text":554,"correct":22},"500r\u002Fmin",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":20,"analysis":33},1033845,"某机械设备配用一台绕线型异步电动机，其额定功率90kW，额定转速589r\u002Fmin， 转子额定电压330V,转子额定电流166. 6A。电动机的最大转矩标幺值为3.1，计算最大启 , 动转矩的系数取0.8。现决定采用对称切除三级电阻启动。试用分析法求各级启动电阻值。 (转子导线电阻忽略不计。） 该绕线型异步电动机的额定转差率为（ ）。",[559,561,563,565],{"key":20,"text":560,"correct":32},"0. 0183；",{"key":24,"text":562,"correct":22},"0.0221；",{"key":27,"text":564,"correct":22},"0. 0316；",{"key":30,"text":566,"correct":22},"0.0366。",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":27,"analysis":33},1033847,"某机械设备配用一台绕线型异步电动机，其额定功率90kW，额定转速589r\u002Fmin， 转子额定电压330V,转子额定电流166. 6A。电动机的最大转矩标幺值为3.1，计算最大启 , 动转矩的系数取0.8。现决定采用对称切除三级电阻启动。试用分析法求各级启动电阻值。 (转子导线电阻忽略不计。）",[571,573,574,576],{"key":20,"text":572,"correct":22},"该绕线型异步电动机转子串电阻启动时，最大启动转矩与切换转矩之比为（）。",{"key":24,"text":490,"correct":22},{"key":27,"text":575,"correct":32},"1.92; C 2. 80；",{"key":30,"text":577,"correct":22},"4.69。",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":24,"analysis":33},1033850,"某机械设备配用一台绕线型异步电动机，其额定功率90kW，额定转速589r\u002Fmin， 转子额定电压330V,转子额定电流166. 6A。电动机的最大转矩标幺值为3.1，计算最大启 , 动转矩的系数取0.8。现决定采用对称切除三级电阻启动。试用分析法求各级启动电阻值。 (转子导线电阻忽略不计。） 该电动机转子额定电阻为（）Ω，转子内电阻标幺值为（)。",[582,584,586,588],{"key":20,"text":583,"correct":22},"转子額定电阻0.66，转子内电阻标幺值0.0183;",{"key":24,"text":585,"correct":32},"转子額定电阻1.14，转子内电阻标幺值0.0183;",{"key":27,"text":587,"correct":22},"转子额定电阻1.98,转子内电阻标幺值0.05;",{"key":30,"text":589,"correct":22},"转子额定电阻3.42,转子内电阻标幺值0.011。",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":27,"analysis":33},1033853,"计算整流变压器二次相电压为（ ）（选最接近的一个数据)。",[594,596,598,600],{"key":20,"text":595,"correct":22},"750V;",{"key":24,"text":597,"correct":22},"670V；",{"key":27,"text":599,"correct":32},"439V;",{"key":30,"text":601,"correct":22},"230V。",[603,606,609,612,615,618],{"id":15,"name":604,"category":7,"favorite":605},"领导干部任职前廉政法规知识测试题",92,{"id":607,"name":608,"category":7,"favorite":15},595,"建筑结构与设备",{"id":610,"name":611,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":613,"name":614,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":616,"name":617,"category":7,"favorite":8},534,"BIM工程师",{"id":619,"name":617,"category":7,"favorite":8},535]