[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":611},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,21,50,2321,[13,34,46,58,70,82,94,106,118,126,138,150,162,174,186,198,210,222,234,246,258,270,282,294,303,314,326,338,350,362,374,386,398,410,422,432,444,455,467,479,491,503,515,527,539,551,563,575,587,599],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1032951,1,"单选题","探测区域应按（ ）划分，一个探测区域的面积不宜超过（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","楼层，500m2；",false,{"key":24,"text":25,"correct":26},"B","独立房（套）间，500m2；",true,{"key":28,"text":29,"correct":22},"C","独立房（套）间，400m2；",{"key":31,"text":32,"correct":22},"D","楼层，400m2。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},1032953,"某建筑各层应急广播扬声器设置如下：地下一层25X3W，一层45X3W，二层30X3W，三~九层均为25X3W，求应设置火灾应急广播备用扩音机容量为（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"380W；",{"key":24,"text":41,"correct":22},"560W；",{"key":28,"text":43,"correct":26},"450W；",{"key":31,"text":45,"correct":22},"3OOW。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1032956,"高层建筑中的避难层应设消防专用电话分机或电话插孔，其间距不应大于（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"15m；",{"key":24,"text":53,"correct":26},"20m；",{"key":28,"text":55,"correct":22},"25m；",{"key":31,"text":57,"correct":22},"30m。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1032959,"红外光束线型感烟探测器的发射器与接收器之间的距离不宜超过（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"60m；",{"key":24,"text":65,"correct":22},"8Om；",{"key":28,"text":67,"correct":26},"1OOm；",{"key":31,"text":69,"correct":22},"150m。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},1032960,"相邻两组红外光束感烟探测器的水平距离不应大于（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"1Om；",{"key":24,"text":77,"correct":22},"12m；",{"key":28,"text":79,"correct":26},"14m，",{"key":31,"text":81,"correct":22},"16m.",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1032962,"根据规范，二类高层建筑中应设置火灾自动报警系统的部位是（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"面积大于2OOm2的营业厅；",{"key":24,"text":89,"correct":22},"面积大于3OO0m2的营业厅；",{"key":28,"text":91,"correct":22},"面积大于400m2的营业厅；",{"key":31,"text":93,"correct":26},"面积大于5OOm2的营业厅。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},1032965,"对火灾形成特征不可预料的场所，可（）.",[98,100,102,104],{"key":20,"text":99,"correct":22},"采用感烟和感温探測器组合；",{"key":24,"text":101,"correct":22},"采用感烟探测器；",{"key":28,"text":103,"correct":26},"根据模拟实验的结果选择探测器；",{"key":31,"text":105,"correct":22},"采用感溫探測器。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1032967,"可能产生阴燃火或发生火灾不及时报警将造成重大损失的场所，不宜选择（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"离子感烟探測器；",{"key":24,"text":113,"correct":26},"感温探测器；",{"key":28,"text":115,"correct":22},"光电感烟探测器；",{"key":31,"text":117,"correct":22},"点型感烟探测器。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},1032969,"每个防火分区应至少设置一个手动火灾报警按钮，从一个防火分区的任何位置到最邻近的一个手动火灾报警按钮的距离不应大于（）。手动火灾报警按钮宜设置在公共活动场所的出入口处。",[122,123,124,125],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":22},{"key":28,"text":55,"correct":22},{"key":31,"text":57,"correct":26},{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":31,"analysis":33},1032972,"一个点型感烟或感温探测器保护的梁间区域的个数，最多不应大于（）个。",[130,132,134,136],{"key":20,"text":131,"correct":22},"2；",{"key":24,"text":133,"correct":22},"3；",{"key":28,"text":135,"correct":22},"4：",{"key":31,"text":137,"correct":26},"5。",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":28,"analysis":33},1032974,"消防控制室的设计符合规范要求的是（ ）。",[142,144,146,148],{"key":20,"text":143,"correct":22},"消防控制室的门应向内开启，且入口处应设置明显的标志；",{"key":24,"text":145,"correct":22},"消防控制室的送、回风管在其穿墙处应刷防火涂料；",{"key":28,"text":147,"correct":26},"消防控制室内严禁与其无关的电气线路及管路穿过；",{"key":31,"text":149,"correct":22},"消防控制室周围不宜布置电磁场干扰较强及其他影响消防控制设备的设备用房。",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":24,"analysis":33},1032976,"消防控制、消防通信和警报线路采用暗敷设时，宜采用金属管或经阻燃处理的硬质塑料管保护，并应敷设在不燃烧体的结构层内，且保护层厚度不宜小于（）。",[154,156,158,160],{"key":20,"text":155,"correct":22},"200mm；",{"key":24,"text":157,"correct":26},"3Omm；",{"key":28,"text":159,"correct":22},"40mm；",{"key":31,"text":161,"correct":22},"5Omm。",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":28,"analysis":33},1032979,"火灾自动报警系统专用接地干线应采用铜芯绝缘导线，其芯线截面不应小于（）mm2.专用接地干线宜穿（）埋设至接地体。",[166,168,170,172],{"key":20,"text":167,"correct":22},"16，硬质塑料管；",{"key":24,"text":169,"correct":22},"25，镀锌钢管；",{"key":28,"text":171,"correct":26},"25，硬质塑料管；",{"key":31,"text":173,"correct":22},"16，镀锌钢管。",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":24,"analysis":33},1032981,"由消防控制室接地板引至各消防电子设备的专用接地线应选用铜芯绝缘导线，其线芯线截面面积不应小于（）。",[178,180,182,184],{"key":20,"text":179,"correct":22},"2.5mm2；",{"key":24,"text":181,"correct":26},"4mm2；",{"key":28,"text":183,"correct":22},"6mm2；",{"key":31,"text":185,"correct":22},"1Omm2。",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":31,"analysis":33},1032984,"火灾自动报警系统的传输线路的芯线截面选择，除应满足自动报警装置技术条件的要求外，还应满足（）的要求。",[190,192,194,196],{"key":20,"text":191,"correct":22},"导线载流量；",{"key":24,"text":193,"correct":22},"导线热稳定；",{"key":28,"text":195,"correct":22},"自动报警装置技术条件；",{"key":31,"text":197,"correct":26},"机械强度。",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":24,"analysis":33},1032986,"在宽度小于3m的内走道顶棚上设置探测器时，宜居中布置。感温探测器的安装间距不应超过（）；感烟探测器的安装间距不应超过（）；探测器至端墙的距离，不应大于探测器安装间距的一半。",[202,204,206,208],{"key":20,"text":203,"correct":22},"1Om，20m；",{"key":24,"text":205,"correct":26},"1Om，15m；",{"key":28,"text":207,"correct":22},"12m，18m；",{"key":31,"text":209,"correct":22},"15m，2Om。",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":31,"analysis":33},1032988,"消防控制室在确认火灾后，对电梯、消防电梯的控制要求是（ ）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"立即断开电梯的动力电源，只保留消防电梯的动力电源；",{"key":24,"text":217,"correct":22},"将消防电梯落于首层，以便消防人员随时在首层启动消防电梯，实施灭火作业；",{"key":28,"text":219,"correct":22},"除消防电梯外，将其他电梯全部停于首层；",{"key":31,"text":221,"correct":26},"所有电梯（包括消防电梯）全部停于首层。",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":28,"analysis":33},1032990,"厨房、锅炉房宜选用的火灾探测器是（）。",[226,228,230,232],{"key":20,"text":227,"correct":22},"离子感烟火灾探测器；",{"key":24,"text":229,"correct":22},"光电感烟火灾探测器；",{"key":28,"text":231,"correct":26},"感温火灾探测器；",{"key":31,"text":233,"correct":22},"火焰火灾探测器。",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":24,"analysis":33},1032993,"对厅堂、办公室、卧室、教室、客房宜选用的火灾探测器是（）。",[238,240,242,244],{"key":20,"text":239,"correct":22},"定温火灾探测器；",{"key":24,"text":241,"correct":26},"感烟火灾探测器；",{"key":28,"text":243,"correct":22},"火焰火灾探测器；",{"key":31,"text":245,"correct":22},"差温火灾探测器。",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":31,"analysis":33},1032996,"火灾探测区域内所需设置的点式火灾探测器数量应按下列（）原则选择。",[250,252,254,256],{"key":20,"text":251,"correct":22},"一个火灾探测区域内，需设置一个火灾探测器；",{"key":24,"text":253,"correct":22},"火灾探測区域内设置的火灾探测器数量应按其保护半径选取；",{"key":28,"text":255,"correct":22},"火灾探测区域内设置的火灾探测器数量应按其保护面积选取；",{"key":31,"text":257,"correct":26},"火灾探测区域内火灾探测器的安装数量应同时满足保护面积和保护半径的要求。",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":28,"analysis":33},1032998,"火灾自动报瞀系统的供电，应采用的方式为（）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"采用交220V供电，但需单独的供电回路；",{"key":24,"text":265,"correct":22},"采用交流220V消防电源供电；",{"key":28,"text":267,"correct":26},"采用主电源（即消防电源）和直流备用电源供电；",{"key":31,"text":269,"correct":22},"用UPS装置供电。",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":28,"analysis":33},1033000,"火灾自动报警系统应有接地装置，接地装置的接地电阻值应符合的要求是（）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"无论采用何种接地装里，接地电阻值不应大于4Ω；",{"key":24,"text":277,"correct":22},"无论采用何种接地装置，接地电阻值不应大于1Ω",{"key":28,"text":279,"correct":26},"采用专用接地装置时的接地电阻值不应大于4Ω，采用共用接地装置时的接地电阻值不应大于1Ω；",{"key":31,"text":281,"correct":22},"采用专用接地装置时的接地电阻值不应大于1Ω，采用共用接地装置时的接地电阻值不应大于4Ω。",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":20,"analysis":33},1033003,"建筑高度为11Om的住宅属于（ ）保护对象。",[286,288,290,292],{"key":20,"text":287,"correct":26},"特级；",{"key":24,"text":289,"correct":22},"—级；",{"key":28,"text":291,"correct":22},"二级；",{"key":31,"text":293,"correct":22},"不确定。",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":28,"analysis":33},1033005,"总建筑面积为900m2的丙类物质库房属于（）保护对象。",[298,299,301,302],{"key":20,"text":287,"correct":22},{"key":24,"text":300,"correct":22},"一级；",{"key":28,"text":291,"correct":26},{"key":31,"text":293,"correct":22},{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":24,"analysis":33},1033008,"建筑高度为23m、设有中央空调系统的办公楼，可将相邻的（）个小房间划为一个探测区，但这些房间的总面积不得超过400m2，并在门口设有灯光显示装置。",[307,308,310,312],{"key":20,"text":133,"correct":22},{"key":24,"text":309,"correct":26},"5；",{"key":28,"text":311,"correct":22},"8；",{"key":31,"text":313,"correct":22},"10。",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":31,"analysis":33},1033010,"用作防火分隔的防火卷帘，当两侧任何一个火灾探测器动作后，卷帘应（）。",[318,320,322,324],{"key":20,"text":319,"correct":22},"下降至距地（楼）面1.8m；",{"key":24,"text":321,"correct":22},"下降至距地（楼）面1.2m",{"key":28,"text":323,"correct":22},"感烟探测器动作后，下降至距地（楼）面1.8m，感温探测器动作后，再降到底；",{"key":31,"text":325,"correct":26},"下降到底。",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":31,"analysis":33},1033012,"下列场所中，（）处不宜选择感温探测器。",[330,332,334,336],{"key":20,"text":331,"correct":22},"可能发生无烟火灾；",{"key":24,"text":333,"correct":22},"有大量粉尘；",{"key":28,"text":335,"correct":22},"吸烟室；",{"key":31,"text":337,"correct":26},"生产或聚集可燃气体的场所。",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":24,"analysis":33},1033015,"对于一级保护对象，在计算探测器数量时，修正系数K宜取（ ）。",[342,344,346,348],{"key":20,"text":343,"correct":22},"0.7~0.8；",{"key":24,"text":345,"correct":26},"0.8~0.9；",{"key":28,"text":347,"correct":22},"0.9~1.0；",{"key":31,"text":349,"correct":22},"1.0~1.1。",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":28,"analysis":33},1033018,"当梁间净距小于（）时，可不计梁对探测器保护面积的影响。",[354,356,358,360],{"key":20,"text":355,"correct":22},"0.5m；",{"key":24,"text":357,"correct":22},"0.8m；",{"key":28,"text":359,"correct":26},"1.Om；",{"key":31,"text":361,"correct":22},"1.2m。",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":28,"analysis":33},1033020,"针对电梯井、升降机井的火灾探测器宜设在（）。",[366,368,370,372],{"key":20,"text":367,"correct":22},"电梯井、升降机井的顶板上；",{"key":24,"text":369,"correct":22},"电梯井、升降机井的侧墙上；",{"key":28,"text":371,"correct":26},"电梯井、升降机井的上方的机房顶棚上；",{"key":31,"text":373,"correct":22},"电梯、升降机轿厢下方。",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":24,"analysis":33},1033022,"下列火灾探测器的选择，符合要求的是（ ）。",[378,380,382,384],{"key":20,"text":379,"correct":22},"对火灾形成特征不可预料的场所，可选择智能型火灾探测器；",{"key":24,"text":381,"correct":26},"对使用、生产或聚集可燃气体或可燃液体蒸汽的场所，应选择可燃气体探测器；",{"key":28,"text":383,"correct":22},"对火灾发展迅速，可产生大量热、烟和火焰辐射的场所，应选择火焰探测器；",{"key":31,"text":385,"correct":22},"房间高度为12.5m的展厅可采用点型感烟探测器。",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":20,"analysis":33},1033024,"下列宜选择感温探测器的场所是（ ）。",[390,392,394,396],{"key":20,"text":391,"correct":26},"锅炉房、发电机房；",{"key":24,"text":393,"correct":22},"电梯机房；",{"key":28,"text":395,"correct":22},"通信机房；",{"key":31,"text":397,"correct":22},"客房。",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":24,"analysis":33},1033027,"下列探测器的设置，符合要求的是（ ）。",[402,404,406,408],{"key":20,"text":403,"correct":22},"2.6m宽的内走道顶棚设置感烟探测器，安装间距为16m；",{"key":24,"text":405,"correct":26},"探测器至墙壁、梁边的水平距离不小于O.5m；",{"key":28,"text":407,"correct":22},"探测器倾斜安装时，倾斜角不大于50°；",{"key":31,"text":409,"correct":22},"探测器至空调送风口边的水平距离不小于1.4m，",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":20,"analysis":33},1033029,"在梁突出顶棚的高度小于（ ）的顶捆上设置感烟、感温探测器时，可不考虑梁对探测器保护面积的影响。",[414,416,418,420],{"key":20,"text":415,"correct":26},"2OOmm；",{"key":24,"text":417,"correct":22},"2500mm；",{"key":28,"text":419,"correct":22},"3OOmm；",{"key":31,"text":421,"correct":22},"35Omm",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":24,"analysis":33},1033032,"某设备机房，面积6Om2，室内有井字梁，梁突出顶棚3OOmm，该室内安装点型感烟探测器，应设（）个。",[426,428,429,430],{"key":20,"text":427,"correct":22},"1；",{"key":24,"text":131,"correct":26},{"key":28,"text":133,"correct":22},{"key":31,"text":431,"correct":22},"9。",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":24,"analysis":33},1033034,"当采用线槽内敷设的铜芯绝缘导线作为火灾报警系统的传输线路时，导线的截面积不应小于（）。",[436,438,440,442],{"key":20,"text":437,"correct":22},"0.5mm2；",{"key":24,"text":439,"correct":26},"0.75mm2；",{"key":28,"text":441,"correct":22},"1.OOmm2；",{"key":31,"text":443,"correct":22},"1.5mm2。",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":24,"analysis":33},1033037,"某高层酒店内有1宽2叫长50m的走廊，采用感烟探测器，至少应设（）个探测器。",[448,450,452,453],{"key":20,"text":449,"correct":22},"3;",{"key":24,"text":451,"correct":26},"4；",{"key":28,"text":309,"correct":22},{"key":31,"text":454,"correct":22},"6。",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":31,"analysis":33},1033040,"感烟探测器安装时的倾斜角不应大于（ ）。",[459,461,463,465],{"key":20,"text":460,"correct":22},"15°；",{"key":24,"text":462,"correct":22},"25°；",{"key":28,"text":464,"correct":22},"35°；",{"key":31,"text":466,"correct":26},"45°。",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":20,"analysis":33},1033042,"红外光束感烟探测器的光束轴线至顶棚的垂直距离宜为（ ）。",[471,473,475,477],{"key":20,"text":472,"correct":26},"0.3~1.Om；",{"key":24,"text":474,"correct":22},"0.1~O.2m；",{"key":28,"text":476,"correct":22},"0.2~0.3m；",{"key":31,"text":478,"correct":22},"1.0~1.5m。",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":28,"analysis":33},1033045,"智能建筑设计中，对BAS而言，控制对象不包括（ ）。",[483,485,487,489],{"key":20,"text":484,"correct":22},"空调系统；",{"key":24,"text":486,"correct":22},"照明系统；",{"key":28,"text":488,"correct":26},"消防排烟系统；",{"key":31,"text":490,"correct":22},"给排水系统.",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":24,"analysis":33},1033047,"图15-1所示控制系统示意图中，（ ）更像现场总线控制系统。",[495,497,499,501],{"key":20,"text":496,"correct":22},"图15-1（a）；",{"key":24,"text":498,"correct":26},"图15-1（b）；",{"key":28,"text":500,"correct":22},"图15-1（c）；",{"key":31,"text":502,"correct":22},"图15-1（d）。",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":24,"analysis":33},1033051,"按照GB\u002FT 50314—2006《智能建筑设计标准》，BAS不应对变配电设备进行（）。",[507,509,511,513],{"key":20,"text":508,"correct":22},"监视；",{"key":24,"text":510,"correct":26},"控制；",{"key":28,"text":512,"correct":22},"测量；",{"key":31,"text":514,"correct":22},"记录。",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":28,"analysis":33},1033054,"对BAS而言，属于模拟量输入（AI）信号的有（）。",[519,521,523,525],{"key":20,"text":520,"correct":22},"液位开关输出信号；",{"key":24,"text":522,"correct":22},"电动调节阀开度控制信号；",{"key":28,"text":524,"correct":26},"压力传感器输出信号；",{"key":31,"text":526,"correct":22},"电机开\u002F关状态信号。",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":28,"analysis":33},1033056,"对BAS而言，用于热工检测控制的常用开关量仪表不包括（）。",[531,533,535,537],{"key":20,"text":532,"correct":22},"温度开关；",{"key":24,"text":534,"correct":22},"流量开关；",{"key":28,"text":536,"correct":26},"照度开关；",{"key":31,"text":538,"correct":22},"压差开关。",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":28,"analysis":33},1033059,"变风量空调机组与定风量空调机组的基本区别在于（ ）。",[543,545,547,549],{"key":20,"text":544,"correct":22},"变风量空调机组的送风温庋是可现场设定的；",{"key":24,"text":546,"correct":22},"变风量空调机组的冷\u002F热水三通阀是可调的；",{"key":28,"text":548,"correct":26},"变风量空调机组的送风风机的转速是可调的；",{"key":31,"text":550,"correct":22},"变风量空调机组的新风量是可调的。",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":31,"analysis":33},1033061,"在BAS中，依据（ ）与其设定值的比较，对冷却塔风机进行控制。",[555,557,559,561],{"key":20,"text":556,"correct":22},"冷却塔进水压力；",{"key":24,"text":558,"correct":22},"冷却塔出水压力；",{"key":28,"text":560,"correct":22},"冷却塔进水温度；",{"key":31,"text":562,"correct":26},"冷却塔出水澧度，",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":31,"analysis":33},1033065,"对变风量空调机组而言，调整风机转速的目的是保持（ ）的恒定。",[567,569,571,573],{"key":20,"text":568,"correct":22},"新风风量；",{"key":24,"text":570,"correct":22},"总风量；",{"key":28,"text":572,"correct":22},"送风温度；",{"key":31,"text":574,"correct":26},"送风压力。",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":20,"analysis":33},1033067,"空调系统热量计算需测量的参数不包括（ ）。",[579,581,583,585],{"key":20,"text":580,"correct":26},"管道压力；",{"key":24,"text":582,"correct":22},"送风（水）温度；",{"key":28,"text":584,"correct":22},"回风（水）溫度；",{"key":31,"text":586,"correct":22},"风量（水量）。",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":31,"analysis":33},1033070,"在BAS中，（ ）通常采用通信接口方式与控制系统主机进行连网。",[591,593,595,597],{"key":20,"text":592,"correct":22},"定风量空气处理机；",{"key":24,"text":594,"correct":22},"风机盘管；",{"key":28,"text":596,"correct":22},"冷却塔；",{"key":31,"text":598,"correct":26},"冷冻机组。",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":28,"analysis":33},1033072,"建筑设备管理系统通常为（ ）。",[603,605,607,609],{"key":20,"text":604,"correct":22},"分散型控制系统；",{"key":24,"text":606,"correct":22},"集中型控制系统；",{"key":28,"text":608,"correct":26},"集散贺控制系统；",{"key":31,"text":610,"correct":22},"离散型控制系统.",[612,615,618,621,624,627],{"id":15,"name":613,"category":7,"favorite":614},"领导干部任职前廉政法规知识测试题",92,{"id":616,"name":617,"category":7,"favorite":15},595,"建筑结构与设备",{"id":619,"name":620,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":622,"name":623,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":625,"name":626,"category":7,"favorite":8},534,"BIM工程师",{"id":628,"name":626,"category":7,"favorite":8},535]