[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":559},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,2,50,2321,[13,34,42,54,66,78,86,98,110,122,134,146,158,169,181,193,205,217,229,241,253,261,273,285,292,299,306,318,325,337,345,357,365,377,389,401,413,425,433,441,449,461,473,485,497,509,517,529,536,548],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1030454,1,"单选题","在爆炸性粉尘环境内，引燃温度组别为Tll的无过负荷电气设备最髙允许表面温度 为（)，有过负荷电气设备最高允许表面温度为（）。 A. 160'C, 145\"C； B. 120'C, 110'C；",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","215'",false,{"key":24,"text":25,"correct":22},"B","195'C ；",{"key":27,"text":28,"correct":29},"C","150'",true,{"key":31,"text":32,"correct":22},"D","170'C","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1030458,"爆炸危险区域内的通风，其空气流量能使易燃物质很快稀释到爆炸下限值（）以 下时，可定为通风良好。 A.10%B 15%; C. 20%； D. 25%。",[38,39,40,41],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":24,"analysis":33},1030461,"对于易燃物质比空气重的爆炸性气体环境，位于1区、2区附近的变电所、配电所 和控制室地面，应髙出室外地面（ 〉。",[46,48,50,52],{"key":20,"text":47,"correct":22},"0.9m;",{"key":24,"text":49,"correct":29},"0.6m；",{"key":27,"text":51,"correct":22},"0. 45m；",{"key":31,"text":53,"correct":22},"0. 3m.",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":20,"analysis":33},1030464,"在爆炸性粉尘环境内，( )采用绝缘导线或塑料管明设。",[58,60,62,64],{"key":20,"text":59,"correct":29},"严禁,",{"key":24,"text":61,"correct":22},"必须；",{"key":27,"text":63,"correct":22},"宜",{"key":31,"text":65,"correct":22},"不得。",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":27,"analysis":33},1030467,"在爆炸性粉尘环境10区和11区内，电缆线路（ ）有中间接头。",[70,72,74,76],{"key":20,"text":71,"correct":22},"一般可以；",{"key":24,"text":73,"correct":22},"严禁；",{"key":27,"text":75,"correct":29},"不应；",{"key":31,"text":77,"correct":22},"可以。",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":24,"analysis":33},1030471,"在爆炸性粉尘环境电气线路的设计中，敷设电气线路沟道、电缆、钢管，所穿过不 同区域之间墙或楼板的孔洞应采用（ ）严密堵塞。 A.难燃性材料； B非燃性材枓； C.绝缘材料； D.柔性材料。",[82,83,84,85],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":24,"analysis":33},1030475,"可燃油油浸电力变压器室的耐火等级应为（）级。高压配电室、高压电容器室和非燃（或难燃）介质的电力变压器室的耐火等级不应低于（）级。低压配电室、低压电容器室的耐火等级不应低于（）级。",[90,92,94,96],{"key":20,"text":91,"correct":22},"三、二、二；",{"key":24,"text":93,"correct":29},"一、二、三；",{"key":27,"text":95,"correct":22},"二、二、一；",{"key":31,"text":97,"correct":22},"—、二、二；",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":27,"analysis":33},1030480,"数据处理设备为了抑制电源线路导入的干扰常配置有大容量的滤波器，因此正常工 作时就存在较大的对地泄漏电流。当正常泄漏电流超过（ ）时应釆取防止pe线中断导致 电击危险的措施。",[102,104,106,108],{"key":20,"text":103,"correct":22},"10A；",{"key":24,"text":105,"correct":22},"1A；",{"key":27,"text":107,"correct":29},"10mA；",{"key":31,"text":109,"correct":22},"2m",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":31,"analysis":33},1030484,"电流对人体的效应由生理参数和电气参数决定。15~100Hz正弦交流电流摆脱阈的 平均值为（ ）。",[114,116,118,120],{"key":20,"text":115,"correct":22},"1.5mA;",{"key":24,"text":117,"correct":22},"2mA(",{"key":27,"text":119,"correct":22},"0. 1mA；",{"key":31,"text":121,"correct":29},"10m",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":24,"analysis":33},1030487,"直流电流对人体的效应与交流电流对人体的效应有所不同，直流电流的反应阈值约为（ ）。",[126,128,130,132],{"key":20,"text":127,"correct":22},"1.5mA；",{"key":24,"text":129,"correct":29},"2mA；",{"key":27,"text":131,"correct":22},"0.1mA;",{"key":31,"text":133,"correct":22},"0.5m",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":20,"analysis":33},1030491,"油浸式电力变压器必须布置在民用建筑物中时，其总容量不应大于（ ），单台容 量不应大于（ ）。 A. 1260kVA, 630kVA；",[138,140,142,144],{"key":20,"text":139,"correct":29},"1600kVA, 800kVA；",{"key":24,"text":141,"correct":22},"2000kVA, lOOOkVA；",{"key":27,"text":143,"correct":22},"2500kV",{"key":31,"text":145,"correct":22},"1250kV",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":31,"analysis":33},1030495,"接地短路（故障）电流流过接地装置时，地面上水平距离为（）的两点间的电位差称为跨步电位差。",[150,152,154,156],{"key":20,"text":151,"correct":22},"0.6m",{"key":24,"text":153,"correct":22},"0.7m",{"key":27,"text":155,"correct":22},"0.75m",{"key":31,"text":157,"correct":29},"0.8m",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":27,"analysis":33},1030498,"接地短路故障电流流过接地装置时，大地表面形成分布电位，在地面上离设备水平距离为0.8m处与设备外壳、架构或墙壁离地面（）处两点的电位差称为接触电位差。",[162,163,165,167],{"key":20,"text":157,"correct":22},{"key":24,"text":164,"correct":22},"1.5m",{"key":27,"text":166,"correct":29},"1.8m",{"key":31,"text":168,"correct":22},"2.0m",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":31,"analysis":33},1030502,"有关规程对企业合理用电降低线损率提出要求，企业由受电端至用电端分别为三级 变压、二级变压和一级变压，其总线损率应分别不超过（ ）、（ ）和（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":22},"6.5%, 5.5%，3.5%,",{"key":24,"text":176,"correct":22},"10%，7.0%，5. 5%,",{"key":27,"text":178,"correct":22},"7.0%, 5.0%, 2.0%,",{"key":31,"text":180,"correct":29},"7.0%, 5.5%, 3.5%。",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":24,"analysis":33},1030506,"正常运行下标称频率为50HZ的电力系统正常频率偏差允许值为（ ），系统容量 较小时偏差可以放宽到（）。",[185,187,189,191],{"key":20,"text":186,"correct":22},"士0. 1Hz, 士0. ZHz；",{"key":24,"text":188,"correct":29},"士0. 2Hz, ±0. 5Hz;",{"key":27,"text":190,"correct":22},"土0. 25Hz, 土0. 3Hz;",{"key":31,"text":192,"correct":22},"±0. 4Hz, ±0. 5Hz。",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":27,"analysis":33},1030510,"某变电所有一台额定容量为8000kVA的电力变压器，其空载损耗为10. 9kW，短路 损耗为52.8kW,变压器负载系数为0.457,当变压器二次侧负载功率因数cosp2=0.9时, 该变压器的效率为（ )。",[197,199,201,203],{"key":20,"text":198,"correct":22},"90.5%,",{"key":24,"text":200,"correct":22},"97.2%,",{"key":27,"text":202,"correct":29},"99.3%",{"key":31,"text":204,"correct":22},"99.9%。",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":31,"analysis":33},1030513,"三相异步电动机在额定电压下运行，关于电动机的效率，以下说法（ ）是正 确的。",[209,211,213,215],{"key":20,"text":210,"correct":22},"三相异步电动机空载运行时的效率约为50%；",{"key":24,"text":212,"correct":22},"三相异步电动机的效率随负荷减少而升高；",{"key":27,"text":214,"correct":22},"C三相异步电动机空载运行时的效率为最高；",{"key":31,"text":216,"correct":29},"三相异步电动机空载运行时的效率为零。",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":20,"analysis":33},1030517,"—台水泵用交流异步电动机安装在距供电点300m的泵房内。电机额定容量为 10kW,额定电压380V，额定电流21. 4A,空载电流为额定电流的35%。为了减少线路损 失，拟在该电机附近安装一组补偿电容，为了防止电动机产生自励磁过电压，最合适的无功 功率补偿量为（ ）。",[221,223,225,227],{"key":20,"text":222,"correct":29},"4. 4kvar；",{"key":24,"text":224,"correct":22},"5. 5kvar；",{"key":27,"text":226,"correct":22},"5. 8kvar；",{"key":31,"text":228,"correct":22},"6. 0kvar",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":24,"analysis":33},1030521,"某钢铁厂由发电厂用架空线供一路llOkV电源，输电线路长9.71km，导线电阻为 0. 103n\u002Fkm,该线路输送的有功功率为50836kW,电力线路输送负荷的平均功率因数为 0.87，该线路功率损耗为（ ）.",[233,235,237,239],{"key":20,"text":234,"correct":22},"0.282kW",{"key":24,"text":236,"correct":29},"282kW；",{"key":27,"text":238,"correct":22},"345kW；",{"key":31,"text":240,"correct":22},"370kW。",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":24,"analysis":33},1030524,"调整用电设备的工作状态，合理分配与平衡负荷，使企业用电均衡化，提高企业负 荷率，是配电网节电降损的有效措施。根据有关规定，连续性生产企业日负荷率应不低 于（）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"98%,",{"key":24,"text":248,"correct":29},"95%;",{"key":27,"text":250,"correct":22},"85%;",{"key":31,"text":252,"correct":22},"60%。",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":24,"analysis":33},1030528,"变压器的铜损Pou与变压器负载电流I的关系符合（ ）关系式。",[257,258,259,260],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":24,"analysis":33},1030532,"三相异步电动机的效率随电动机负荷的减少而（ ）。",[265,267,269,271],{"key":20,"text":266,"correct":22},"升高；",{"key":24,"text":268,"correct":29},"降低；",{"key":27,"text":270,"correct":22},"不变；",{"key":31,"text":272,"correct":22},"关系不定",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":24,"analysis":33},1030536,"异步电动机端电压下降为额定电压90%时，电动机起动转矩为额定转矩的（ ）。",[277,279,281,283],{"key":20,"text":278,"correct":22},"90%；",{"key":24,"text":280,"correct":29},"81%;",{"key":27,"text":282,"correct":22},"19%;",{"key":31,"text":284,"correct":22},"10%。",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":287,"answer":24,"analysis":33},1030541,[288,289,290,291],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":294,"answer":27,"analysis":33},1030544,[295,296,297,298],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":301,"answer":31,"analysis":33},1030548,[302,303,304,305],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":20,"analysis":33},1030551,"异步电动机空载时，功率因数很低。负载逐渐增加时，功率因数上升。当异步电动机（）额定负载时，功率因数达到最大值。",[310,312,314,316],{"key":20,"text":311,"correct":29},"接近；",{"key":24,"text":313,"correct":22},"达到；",{"key":27,"text":315,"correct":22},"超过5%;",{"key":31,"text":317,"correct":22},"超过7%。",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":320,"answer":31,"analysis":33},1030555,[321,322,323,324],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":24,"analysis":33},1030559,"企业在提高自然功率因数的基础上，应在负荷侧合理装置集中与就地无功补偿设 备，在企业最大负荷时的功率因数应不低于（ ）。",[329,331,333,335],{"key":20,"text":330,"correct":22},"0.88;",{"key":24,"text":332,"correct":29},"0.90;",{"key":27,"text":334,"correct":22},"0.92；",{"key":31,"text":336,"correct":22},"0.95。",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":31,"analysis":33},1030563,"有一个40W的荧光灯，电源电压为220V,频率为50HZ.未并联电容器前功率因 数为0.5,要求并联电容器后功率因数为0.95。计箅并联电容器的电容值为（ ）。",[341,342,343,344],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":33},1030567,"某35kV电网最小短路容量为350MVA,实測电网中11次谐波电流为7.2A,问该 电网11次谐波电流的允许值为（ ）。电网的实际11次谐波电流（ )允许值（35kV 电网基准短路容量注入公共连接点的11次谐波电流允许值为5. 6 A).",[349,351,353,355],{"key":20,"text":350,"correct":22},"5. 6A,超出；",{"key":24,"text":352,"correct":29},"7. 84A,不超出；",{"key":27,"text":354,"correct":22},"4. OA,超出；",{"key":31,"text":356,"correct":22},"10.19A,不超出。",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":33},1030571,"某三相桥式整流装置输出电压脉波数m= 6,假设网侧电压、供电变压器参数、电 抗器参数和触发延迟角等均各相对称，整流电流波形近似方波考虑，该装置网侧谐波电流的 次数应为（)组数据。 A. 3、 5、 7、 9、 11、 13、 15、 17,; B. 5、7、11、13、17、19、23、25； C 2、3、4、5、6、7、8、9、10; D. 4、6、8、10、12、14、16、18…。",[361,362,363,364],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":27,"analysis":33},1030574,"面积为150m2主计算机房内的噪声，在计箅机系统停机的条件下，在主操作员位置 测量应小于（ 〉。 A. 90dB (A); B. 85dB (A)；",[369,371,373,375],{"key":20,"text":370,"correct":22},"68dB",{"key":24,"text":372,"correct":22},";",{"key":27,"text":374,"correct":29},"55dB",{"key":31,"text":376,"correct":22},"。",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":20,"analysis":33},1030578,"某面积为200m2主计箅机房内无线电干扰场强，在频率为0.15~1000MHz时不应 大于（ ）。",[381,383,385,387],{"key":20,"text":382,"correct":29},"126dB；",{"key":24,"text":384,"correct":22},"105dB；",{"key":27,"text":386,"correct":22},"85dB；",{"key":31,"text":388,"correct":22},"68dB?",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":27,"analysis":33},1030581,"对于随机性不规则的电压波动，其电压变动限值为：35kV以下为（ ），llOkV 为（ ）。",[393,395,397,399],{"key":20,"text":394,"correct":22},"4%, 3%；",{"key":24,"text":396,"correct":22},"2%, 3%；",{"key":27,"text":398,"correct":29},"2%, 1.5%；",{"key":31,"text":400,"correct":22},"1%, 1.2%",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":20,"analysis":33},1030585,"电力系统公共连接点由波动负荷产生电压变动，当变动频率在1~10次\u002Fh范围内， 380V系统电压变动限值为（），llOkV系统电压变动限值为（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":29},"3%, 2.5%;",{"key":24,"text":408,"correct":22},"2.5%, 3%；",{"key":27,"text":410,"correct":22},"l.25%,1.5%",{"key":31,"text":412,"correct":22},"4%，3%。",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":33},1030589,"380V电力系统公共连接点短时间闪变限值为（），长时间闪变限值为（）。",[417,419,421,423],{"key":20,"text":418,"correct":22},"0.8，1；",{"key":24,"text":420,"correct":29},"1.0, 0.8；",{"key":27,"text":422,"correct":22},"0.9，0.7；",{"key":31,"text":424,"correct":22},"0.8, 0.6,",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":20,"analysis":33},1030593,"工频过电压的标幺值和操作过电压的标幺值表达式及Um的含义为（）。",[429,430,431,432],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":20,"analysis":33},1030597,"110, 35.lOkV供电系统的工频过电压限值分别为（ 〉。",[437,438,439,440],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":27,"analysis":33},1030601,"高压感应电动机合闸过电压一般不超过（ ），空载分闸过电压不超过（ 〉。",[445,446,447,448],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":27,"analysis":33},1030603,"lOkV电网奇次谐波电压含有率限值为（ 〉，电压总谐波畸变率限值为（ ）",[453,455,457,459],{"key":20,"text":454,"correct":22},"4.0%, 5.0%;",{"key":24,"text":456,"correct":22},"1.2%, 3.0%5",{"key":27,"text":458,"correct":29},"3.2%，4.0%;",{"key":31,"text":460,"correct":22},"2.4%, 3.0%。",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":31,"analysis":33},1030607,"非晶态合金变压器是我国“九五”重点推广的新型节能产品。这种变压器是利用铁、硼、硅、碳四种元素 合成的非晶合金作变压器的（）材料，特点是（）极小。",[465,467,469,471],{"key":20,"text":466,"correct":22},"绝缘，泄漏电流损失；",{"key":24,"text":468,"correct":22},"导体，电阻率；",{"key":27,"text":470,"correct":22},"C外壳保护，漏磁损失；",{"key":31,"text":472,"correct":29},"铁芯，铁磁损失。",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":31,"analysis":33},1030611,"三相异步电动机空载运行的效率为（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":22},"70%~80%;",{"key":24,"text":480,"correct":22},"15%~20%;",{"key":27,"text":482,"correct":22},"50%;",{"key":31,"text":484,"correct":29},"0%。",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":20,"analysis":33},1030616,"在同步电动机运行中，调整励磁电流可以调整功率因数。在任何负载下，当功率因 数调整为（ ）时，定子电流最小。",[489,491,493,495],{"key":20,"text":490,"correct":29},"1；",{"key":24,"text":492,"correct":22},"0；",{"key":27,"text":494,"correct":22},"超前；",{"key":31,"text":496,"correct":22},"滞后。",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":27,"analysis":33},1030620,"某鼓风机站有一台风机每年工作时间为7000h,机械轴功率为68.2kW机械传动 装置的效率为75%。该风机现配套电机的效率为91. 5%,欲更换为效率为95.4% 的髙效电 机。鼓风机站所在地区电价为0.55元\u002FkWh。更换高效电机后每年可节约电费（ ）元。",[501,503,505,507],{"key":20,"text":502,"correct":22},"10512;",{"key":24,"text":504,"correct":22},"14016;",{"key":27,"text":506,"correct":29},"15641；",{"key":31,"text":508,"correct":22},"17600。",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":20,"analysis":33},1030623,"某工厂有一台功率为2500kW的直流电动机，原为电动机一发电机组供电，机组效 率为79%;现采用晶闸管变流装置供电，效率提高为89%。该电动机每年运行的有效时间 为5600h。请计箅采用晶闸管变流装置后每年可节省电能（ ）。",[513,514,515,516],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":27,"analysis":33},1030627,"某车间有一台异步电动机，额定输出功率190kW,额定电压3000V,额定电流 45.5A,空载电流16A,额定效率为91. 05%.计算这台异步电动机额定负载时总损耗为（）",[521,523,525,527],{"key":20,"text":522,"correct":22},"6.23kW；",{"key":24,"text":524,"correct":22},"10.78kW；",{"key":27,"text":526,"correct":29},"18.68kW；",{"key":31,"text":528,"correct":22},"19.71kW。",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":531,"answer":31,"analysis":33},1030630,[532,533,534,535],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":20,"analysis":33},1030634,"某工厂进行升压改造后电压等级由10kV升为35kV，当输送负荷不变的条件下， 升压后功率损耗降低（ 〉。",[540,542,544,546],{"key":20,"text":541,"correct":29},"91.8%；",{"key":24,"text":543,"correct":22},"87.5%；",{"key":27,"text":545,"correct":22},"60.5%；",{"key":31,"text":547,"correct":22},"55.6%。",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":550,"answer":31,"analysis":33},1030638,[551,553,555,557],{"key":20,"text":552,"correct":22},"60.8%；",{"key":24,"text":554,"correct":22},"50.6%",{"key":27,"text":556,"correct":22},"45.3%；",{"key":31,"text":558,"correct":29},"38. 4%。",[560,563,566,569,572,575],{"id":15,"name":561,"category":7,"favorite":562},"领导干部任职前廉政法规知识测试题",92,{"id":564,"name":565,"category":7,"favorite":15},595,"建筑结构与设备",{"id":567,"name":568,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":570,"name":571,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":573,"name":574,"category":7,"favorite":8},534,"BIM工程师",{"id":576,"name":574,"category":7,"favorite":8},535]