[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-16":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":579},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,16,50,2321,[13,30,42,54,65,77,89,101,112,124,133,145,157,169,180,192,204,216,226,238,250,262,270,278,290,302,314,323,335,347,359,367,379,391,403,411,423,431,443,455,467,479,491,503,511,523,535,547,559,567],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":29},1032472,1,"单选题","直流仪表配用外附分流器的精确度等级，不应低于（）级。 A. 0.5； B. 1.0； C 1.5; D. 2.0.",[19,22,25,27],{"key":20,"text":20,"correct":21},"A",true,{"key":23,"text":23,"correct":24},"B",false,{"key":26,"text":26,"correct":24},"C",{"key":28,"text":28,"correct":24},"D","",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":32,"options":33,"answer":23,"analysis":29},1032474,"在315kVA以下的变压器低压侧计费的电力用户能量计量点应采用（ 〉级的无功 电能表。",[34,36,38,40],{"key":20,"text":35,"correct":24},"1.5;",{"key":23,"text":37,"correct":21},"2.0;",{"key":26,"text":39,"correct":24},"2.5;",{"key":28,"text":41,"correct":24},"3.0.",{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":26,"analysis":29},1032476,"指示仪表和仪表，宜装在中心线距地面尺寸为（ ）的髙度。",[46,48,50,52],{"key":20,"text":47,"correct":24},"0.8~1.5m;",{"key":23,"text":49,"correct":24},"1.0~1.5m;",{"key":26,"text":51,"correct":21},"0. 8~2. 0m;",{"key":28,"text":53,"correct":24},"1. 0~1. 8m。",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":20,"analysis":29},1032479,"电能计量仪表和记录仪表，宜装在中心线距地面尺寸为（ ）的高度.",[58,60,62,63],{"key":20,"text":59,"correct":21},"0.6~1.8m;",{"key":23,"text":61,"correct":24},"0. 3~1. 5m;",{"key":26,"text":51,"correct":24},{"key":28,"text":64,"correct":24},"1.0~1.5m。",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":23,"analysis":29},1032481,"保护用电流互感器除应满足一次回路的额定电压、额定电流和短路时的动、热稳定 要求外，还应按照电流互感器的（ ）误差曲线进行校验，使在保护装置动作时，误差不超 过 10%.",[69,71,73,75],{"key":20,"text":70,"correct":24},"5%；",{"key":23,"text":72,"correct":21},"10%；",{"key":26,"text":74,"correct":24},"12%；",{"key":28,"text":76,"correct":24},"15%",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":79,"options":80,"answer":28,"analysis":29},1032483,"继电保护、自动装置、控制、信号的二次回路的工作电压不应超过（ ）。",[81,83,85,87],{"key":20,"text":82,"correct":24},"220V；",{"key":23,"text":84,"correct":24},"250V；",{"key":26,"text":86,"correct":24},"300V；",{"key":28,"text":88,"correct":21},"500V。",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":23,"analysis":29},1032485,"装有管型避雷器的线路，保护装置的动作时间不应大于0.08s(保护装置起动元件 的返回吋间不应小于（ ）。",[93,95,97,99],{"key":20,"text":94,"correct":24},"0.01s；",{"key":23,"text":96,"correct":21},"0.02s;",{"key":26,"text":98,"correct":24},"0.03s;",{"key":28,"text":100,"correct":24},"0.04s。",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":23,"analysis":29},1032487,"保护装置采用的电流互感器及中间电流互感器的稳态比误差，不应大于（ ）。",[105,106,108,110],{"key":20,"text":70,"correct":24},{"key":23,"text":107,"correct":21},"10%;",{"key":26,"text":109,"correct":24},"15%；",{"key":28,"text":111,"correct":24},"20%。",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":20,"analysis":29},1032489,"继电保护、自动装置、控制、信号的二次回路线路，按机械强度要求，铜芯控制电 缆或绝缘导线的芯线最小截面为：强电控制回路，不应小于1.5mm2;弱电回路，不应小 于（ ）.",[116,118,120,122],{"key":20,"text":117,"correct":21},"0.5mm2;",{"key":23,"text":119,"correct":24},"0.75mm2;",{"key":26,"text":121,"correct":24},"1.5mm2;",{"key":28,"text":123,"correct":24},"2. 5mm2 .",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":23,"analysis":29},1032491,"继电保护、自动装置、控制、信号的二次回路线路中的操作回路，在最大负荷下， 操作母线至设备的电压降，不应超过额定电压的（ )。",[128,129,130,132],{"key":20,"text":70,"correct":24},{"key":23,"text":107,"correct":21},{"key":26,"text":131,"correct":24},"15%,",{"key":28,"text":111,"correct":24},{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":28,"analysis":29},1032492,"下列电压互感器接线方式中错误的是（ ）。",[137,139,141,143],{"key":20,"text":138,"correct":24},"电压互感器二次回路中，除接成开口三角形的剩余二次绕组和另有规定者外，应在 其出口装设熔断器或自动开关;",{"key":23,"text":140,"correct":24},"0.5级电能表电压回路，宜由电压互感器出线端装设单独熔断器或自动开关；",{"key":26,"text":142,"correct":24},"电压互感器二次侧采用B相接地方式时，B相熔断器或自动开关应接在绕组出线端 与接地点之间；",{"key":28,"text":144,"correct":21},"电压互感器接成开口三角的剩余二次绕组的试验芯出线端，不应装设熔断器或自动 开关。",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":28,"analysis":29},1032494,"电测量指示性仪表用电压互感器二次回路电缆的电压降应不大于额定二次电压的 ( )才符合规定要求。",[149,151,153,155],{"key":20,"text":150,"correct":24},"0. 25%~0.5%；",{"key":23,"text":152,"correct":24},"0.5%~1%;",{"key":26,"text":154,"correct":24},"1%~2%",{"key":28,"text":156,"correct":21},"1% ~3%。",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":20,"analysis":29},1032495,"电能量计费用电压互感器二次回路电缆压降应不大于额定二次电压的（ ）。",[161,163,165,167],{"key":20,"text":162,"correct":21},"0.25%,",{"key":23,"text":164,"correct":24},"0.5%；",{"key":26,"text":166,"correct":24},"1%；;",{"key":28,"text":168,"correct":24},"3%。",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":23,"analysis":29},1032497,"电力系统内部的考核用0. 5级电能表的电压互感器二次回路电缆的电压降可适当放 宽，但应不大于额定二次电压的（ ).",[173,175,177,179],{"key":20,"text":174,"correct":24},"0.25%；",{"key":23,"text":176,"correct":21},"0.5%; .",{"key":26,"text":178,"correct":24},"1%;",{"key":28,"text":168,"correct":24},{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":28,"analysis":29},1032499,"控制电缆宜采用多芯电缆，应尽可能减少电缆根数，当芯线截面为1.5mm2时，电 缆芯数不宜超过（ ）。",[184,186,188,190],{"key":20,"text":185,"correct":24},"10；",{"key":23,"text":187,"correct":24},"19;",{"key":26,"text":189,"correct":24},"24；",{"key":28,"text":191,"correct":21},"37。",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":23,"analysis":29},1032500,"五防闭锁功能指（ ）",[196,198,200,202],{"key":20,"text":197,"correct":24},"防止带负荷拉（合）隔离开关，防止误拉（合）断路器，防止带电挂地线，防止带 地线合闸，防止带电调整变压器有载分接开关；",{"key":23,"text":199,"correct":21},"防止带负荷拉（合）隔离开关，防止误拉（合）断路器，防止带电挂地线，防止带 地线合闸，防止误入有电间隔；",{"key":26,"text":201,"correct":24},"防止带负荷拉（合）隔离开关，防止误入有电间隔，防止带电挂地线，防止带地线 合闸，防止带电调整变压器有载分接开关；",{"key":28,"text":203,"correct":24},"防止带负荷拉（合）隔离开关，防止误拉（合）断路器，防止带电挂地线，防止误 入有电间隔，防止带电调整变压器有载分接开关。",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":20,"analysis":29},1032502,"数字式仪表的准确度最低要求为（）级.",[208,210,212,214],{"key":20,"text":209,"correct":21},"0.5；",{"key":23,"text":211,"correct":24},"1.0；",{"key":26,"text":213,"correct":24},"1.5；",{"key":28,"text":215,"correct":24},"2.5。",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":20,"analysis":29},1032504,"当仪表准确度等级为0.5级时，相应的电流和电压互感器、变送器、分流器的最低 准确度为（ ）级。",[220,222,224,225],{"key":20,"text":221,"correct":21},"0.5;",{"key":23,"text":223,"correct":24},"1.0;",{"key":26,"text":35,"correct":24},{"key":28,"text":215,"correct":24},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":23,"analysis":29},1032506,"I、Ⅱ类电能计量装置准确度最低要求为有功电能表（ ），无功电能表（ ）， 电压互感器（ ），电流互感器（ ）.",[230,232,234,236],{"key":20,"text":231,"correct":24},"0. 2S 或 0. 2 级，2.0 级，0.2 级，0. 2S 或 0. 2 级；",{"key":23,"text":233,"correct":21},"0. 5S 或 0. 5 级，2.0 级，0.2 级，0. 2S 或 0. 2 级；",{"key":26,"text":235,"correct":24},"0. 5S 或 0.5 级，2.0 级，0.5 级，0. 5S 或 0. 5 级；",{"key":28,"text":237,"correct":24},"0. 5S 或 0. 5 级，1.0 级，0.2 级，0. 2S 或 0. 2 级。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":29},1032508,"控制屏上测量仪表的最低位置不宜小于（)。",[242,244,246,248],{"key":20,"text":243,"correct":21},"1500mm；",{"key":23,"text":245,"correct":24},"1600mm；",{"key":26,"text":247,"correct":24},"1700mm；",{"key":28,"text":249,"correct":24},"1800mm",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":23,"analysis":29},1032510,"对中性点非直接接地系统的电压互感器，需要检查和监视一次回路单相接地时，应 选用三相五柱或三个单相式电压互感器，其剩余绕组额定电压应为（ ）。",[254,256,258,260],{"key":20,"text":255,"correct":24},"100V；",{"key":23,"text":257,"correct":21},"100\u002F3V;",{"key":26,"text":259,"correct":24},"3X100V；",{"key":28,"text":261,"correct":24},"57.7V。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":20,"analysis":29},1032511,"断路器的跳、合闸回路中的电流启动、电压保持的防跳继电器，其电流自保持线圈 的额定电流宜不大于跳、合闸绕组额定电流的（ ）。 A. 50%； B. 60%, C 70%; D. 80%。",[266,267,268,269],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":26,"analysis":29},1032513,"直流系统绝缘监测装置的测量准确度不应低于（ ）级。",[274,275,276,277],{"key":20,"text":221,"correct":24},{"key":23,"text":211,"correct":24},{"key":26,"text":35,"correct":21},{"key":28,"text":215,"correct":24},{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":26,"analysis":29},1032515,"对（ ）及以上容量的低压电动机回路宜测量交流电流。",[282,284,286,288],{"key":20,"text":283,"correct":24},"30kW;",{"key":23,"text":285,"correct":24},"47kW；",{"key":26,"text":287,"correct":21},"55kW；",{"key":28,"text":289,"correct":24},"75kW。",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":20,"analysis":29},1032517,"下列应监测交流系统的绝缘的回路为（ )母线",[294,296,298,300],{"key":20,"text":295,"correct":21},"6kV不接地系统；",{"key":23,"text":297,"correct":24},"llOkV接地系统；",{"key":26,"text":299,"correct":24},"220kV接地系统；",{"key":28,"text":301,"correct":24},"500kV接地系统.",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":26,"analysis":29},1032519,"额定电压时信号继电器的电流灵敏系数宜不小于（ ）。",[306,308,310,312],{"key":20,"text":307,"correct":24},"1.2;",{"key":23,"text":309,"correct":24},"1.3;",{"key":26,"text":311,"correct":21},"1.4；",{"key":28,"text":313,"correct":24},"1.5。",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":28,"analysis":29},1032521,"电压互感器二次侧低压断路器瞬时脱扣器的动作电流，应按大于电压互感器二次回 路的最大负荷电流来整定，其可靠系数应取（ ）。",[318,319,320,322],{"key":20,"text":307,"correct":24},{"key":23,"text":309,"correct":24},{"key":26,"text":321,"correct":24},"1.4;",{"key":28,"text":313,"correct":21},{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":28,"analysis":29},1032523,"当采用单个屏时，控制屏和继电器屏宜采用（ ）尺寸。",[327,329,331,333],{"key":20,"text":328,"correct":24},"宽 1000mm,深 600mm,高 2300mm;",{"key":23,"text":330,"correct":24},"宽 600mm,深 550mm，高 2300mm;",{"key":26,"text":332,"correct":24},"宽 800mm,深 550mm,高 2300mm;",{"key":28,"text":334,"correct":21},"宽 800mm，深 600mm,高 2200mm。",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":20,"analysis":29},1032524,"户外隔离开关操作闭锁用电源，推荐采用（ ）电压。",[339,341,343,345],{"key":20,"text":340,"correct":21},"~220V;",{"key":23,"text":342,"correct":24},"~250V;",{"key":26,"text":344,"correct":24},"~380V;",{"key":28,"text":346,"correct":24},"~500V。",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":23,"analysis":29},1032526,"主控制室按规程规定应设置（ ）个出口。",[351,353,355,357],{"key":20,"text":352,"correct":24},"1,",{"key":23,"text":354,"correct":21},"2；",{"key":26,"text":356,"correct":24},"3;",{"key":28,"text":358,"correct":24},"4。",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":26,"analysis":29},1032528,"断路器的防跳回路，以下说法正确的是（ ）。 A.由断路器辅助触点及中间继电器组成防跳回路接线； B.由断路器辅助触点及串接电阻组成防跳回路接线； c.采用电流启动电压自保持的防跳回路接线； D.由断路器辅助触点和由电流启动并保持的防跳回路接线。",[363,364,365,366],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":23,"analysis":29},1032530,"继电保护设计时应满足的要求是（ ）。",[371,373,375,377],{"key":20,"text":372,"correct":24},"可靠性（信赖性和安全性）、选择性、灵敏性和经济性；",{"key":23,"text":374,"correct":21},"可靠性（信赖性和安全性）、选择性、灵敏性和速动性；",{"key":26,"text":376,"correct":24},"可靠性（信赖性和安全性）、选择性、合理性和经济性；",{"key":28,"text":378,"correct":24},"可靠性（信赖性和安全性）、合理性、选择性和快速性。",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":28,"analysis":29},1032532,"后备保护是指（ ）。",[383,385,387,389],{"key":20,"text":384,"correct":24},"高频保护；",{"key":23,"text":386,"correct":24},"b.母线保护；",{"key":26,"text":388,"correct":24},"c.电流速断保护;",{"key":28,"text":390,"correct":21},"d.当主保护或断路器拒动时，.用以切除故障的保护。",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":23,"analysis":29},1032534,"高压输电线路的电流保护工作原理是（ 〉。",[395,397,399,401],{"key":20,"text":396,"correct":24},"a.以测量保护安装处电压量为作用量的继电保护；",{"key":23,"text":398,"correct":21},"b.以通过保护安装处的电流为作用量的继电保护；",{"key":26,"text":400,"correct":24},"C以测量通过主变压器髙压侧的电流为作用量的继电保护；",{"key":28,"text":402,"correct":24},"d.以测量通过发电机电流为作用量的继电保护。",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":23,"analysis":29},1032536,"继电保护整定计箅时，短路电流计箅的以下假设条件，（ 〉是不正确的。",[407,408,409,410],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":26,"analysis":29},1032537,"继电保护整定计箅时，以下配合原则中（ 〉是不正确的。",[415,417,419,421],{"key":20,"text":416,"correct":24},"上下级保护之间，除有特殊规定外，必须遵循逐级配合原则，在灵敏度与动作时间 上均相互配合，以保证电网保护在电网发生故障时或出现异常运行情况下有选择地动作；",{"key":23,"text":418,"correct":24},"各种保护按阶段原则选择整定值和控制短路功率的方向（如果这是必要的话）来保 证动作的选择性，具有“绝对选择性\"的纵联或横联差动保护除外；",{"key":26,"text":420,"correct":21},"相邻保护之间，其主保护段应与相邻后备保护段配合；",{"key":28,"text":422,"correct":24},"两侧电源的保护，当无方向性时，则应按正反两个方向与相邻保护配合，当可选择 带方向性时，则整定方向按同方向配合。",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":26,"analysis":29},1032539,"A. 0. 3s； B . 0. 4s； C. 0. 5s； D. 0. 6s.。",[427,428,429,430],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":24},{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":28,"analysis":29},1032541,"110~220kV直接接地电力网的线路，下列配置原则中（ ）是正确的。",[435,437,439,441],{"key":20,"text":436,"correct":24},"只装设反应接地短路的保护；",{"key":23,"text":438,"correct":24},"只装设反应相间短路的保护；",{"key":26,"text":440,"correct":24},"只装设零序电流保护；",{"key":28,"text":442,"correct":21},"装设反应相间短路和接地短路的保护。",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":26,"analysis":29},1032543,"llOkV中性点直接接地电力网的线路保护中，相间保护电流回路的电流互感器采用 ( )方式。",[447,449,451,453],{"key":20,"text":448,"correct":24},"采用两相式电流互感器；",{"key":23,"text":450,"correct":24},"采用三相三角形接线；",{"key":26,"text":452,"correct":21},"采用三相星形接线；",{"key":28,"text":454,"correct":24},"采用三相三角形或三相星形接线。",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":28,"analysis":29},1032545,"llOkV中性点直接接地电力网，线路后备保护的配置原则是（).",[459,461,463,465],{"key":20,"text":460,"correct":24},"宜采用远、近結合的后备方式；",{"key":23,"text":462,"correct":24},"宜采用断路器失灵保护作后备的方式;",{"key":26,"text":464,"correct":24},"宜采用近后备方式；",{"key":28,"text":466,"correct":21},"宜采用远后备方式。",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":20,"analysis":29},1032547,"llOkV及以上中性点直接接地的电力网中，变压器中性点直接接地运行，对外部 发生单相接地故障，应装设（〉。",[471,473,475,477],{"key":20,"text":472,"correct":21},"零序电流保护；",{"key":23,"text":474,"correct":24},"零序电压保护；",{"key":26,"text":476,"correct":24},"C零序电流电压保护；",{"key":28,"text":478,"correct":24},"复合电压启动过电流保护。",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":28,"analysis":29},1032548,"对2MW以上的异步电动机的定子绕组及其引出线的相间短路故障，按规定装 设（ ）。",[483,485,487,489],{"key":20,"text":484,"correct":24},"过电流保护；",{"key":23,"text":486,"correct":24},"低电压闭锁过电流保护；",{"key":26,"text":488,"correct":24},"电流速断保护；",{"key":28,"text":490,"correct":21},"纵联差动保护。",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":26,"analysis":29},1032550,"应装失步保护的电动机为（ ）。",[495,497,499,501],{"key":20,"text":496,"correct":24},"1MW及以上异步电动机；",{"key":23,"text":498,"correct":24},"2MW及以上异步电动机；",{"key":26,"text":500,"correct":21},"同步电动机；",{"key":28,"text":502,"correct":24},"2MW及以上同步电动机",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":23,"analysis":29},1032552,"宜装设专用失磁保护的电动机为（ ）。 A. 2MW及以上异步电动机； B同步电动机； C. 2MW及以上同步电机； D. 1MW及以上同步电机。",[507,508,509,510],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":23,"analysis":29},1032554,"对单相接地故障，当接地电流大于（ ）吋，电动机应装设有选择性的单相接地 保护。",[515,517,519,521],{"key":20,"text":516,"correct":24},"3A;",{"key":23,"text":518,"correct":21},"5A；",{"key":26,"text":520,"correct":24},"7A",{"key":28,"text":522,"correct":24},"10",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":23,"analysis":29},1032556,"( )及以上的油浸式变压器和0.4MVA及以上的车间内油浸式变压器，均应装 设瓦斯保护。",[527,529,531,533],{"key":20,"text":528,"correct":24},"0. 4MVA；",{"key":23,"text":530,"correct":21},"0. 8MVA；",{"key":26,"text":532,"correct":24},"1.0MVA;",{"key":28,"text":534,"correct":24},"15MV",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":23,"analysis":29},1032558,"( )及以上单独运行的变压器和（ ）及以上并列运行的变压器，应装设纵联差 动保护。",[539,541,543,545],{"key":20,"text":540,"correct":24},"8MVA, 5MVA,",{"key":23,"text":542,"correct":21},"10MVA, 6. 3MVA;",{"key":26,"text":544,"correct":24},"12. 5MVA, 6.3MVA;",{"key":28,"text":546,"correct":24},"12. 5MVA, 8MV",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":26,"analysis":29},1032559,"对于弹簧储能操动机构的断路器的变配电所宜采用（ ）作为合、分闸操作电源。",[551,553,555,557],{"key":20,"text":552,"correct":24},"220V蓄电池组；",{"key":23,"text":554,"correct":24},"1lOV蓄电池组；",{"key":26,"text":556,"correct":21},"小容量镉镍电池；",{"key":28,"text":558,"correct":24},"硅整流和电容储能。",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":23,"analysis":29},1032561,"中型配电所当装有电磁操动机构时，合闸宜采用（ ）。 A. 1lOkV蓄电池组； B硅整流； C 220V蓄电池组； D.小容量镉镍电池装置。",[563,564,565,566],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":24},{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":26,"analysis":29},1032563,"蓄电池组在正常浮充电方式下，直流母线电压应为直流系统额定电压的（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":24},"95%；",{"key":23,"text":574,"correct":24},"100%；",{"key":26,"text":576,"correct":21},"105%；",{"key":28,"text":578,"correct":24},"110%。",[580,583,586,589,592,595],{"id":15,"name":581,"category":7,"favorite":582},"领导干部任职前廉政法规知识测试题",92,{"id":584,"name":585,"category":7,"favorite":15},595,"建筑结构与设备",{"id":587,"name":588,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":590,"name":591,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":593,"name":594,"category":7,"favorite":8},534,"BIM工程师",{"id":596,"name":594,"category":7,"favorite":8},535]