[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":597},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,15,50,2321,[13,34,45,57,68,80,92,104,114,126,138,149,160,172,184,196,204,215,227,239,251,263,275,287,299,311,323,331,343,355,367,379,391,403,415,427,439,451,459,471,483,495,507,519,531,541,553,564,574,585],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1032360,1,"单选题","在TN—C接地系统中，采用多芯铝电缆中的芯线作PEN线干线时，其截面不应",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","小于（ ）。",false,{"key":24,"text":25,"correct":26},"B","2. 5mm2 ；",true,{"key":28,"text":29,"correct":22},"C","4mm2 ；",{"key":31,"text":32,"correct":22},"D","6mm2 ； D1Omm2.","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1032363,"在TN—C接地系统中，采用单芯铜导线作PEN线干线时，其截面不应小 于（ ）.",[38,40,41,43],{"key":20,"text":39,"correct":22},"2. 5mm2；",{"key":24,"text":29,"correct":22},{"key":28,"text":42,"correct":22},"6mm2 ；",{"key":31,"text":44,"correct":26},"1Omm2 .",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":24,"analysis":33},1032364,"相线截面为16mm2及以下时，相同材质的PE线截面不应小于相线的（ ）。",[49,51,53,55],{"key":20,"text":50,"correct":22},"50%;",{"key":24,"text":52,"correct":26},"100%;",{"key":28,"text":54,"correct":22},"按谐波电流确定；",{"key":31,"text":56,"correct":22},"按接地故障电流确定.",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":20,"analysis":33},1032367,"相线截面大于35mm2时，相同材质的PE线截面不应小于相线的（ ）。",[61,63,65,66],{"key":20,"text":62,"correct":26},"50%；",{"key":24,"text":64,"correct":22},"100%；",{"key":28,"text":54,"correct":22},{"key":31,"text":67,"correct":22},"按接地故障电流确定。",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":24,"analysis":33},1032370,"有谐波电流的低压配电线路，采用N线和相线等截面的4芯电缆（另加PE线 芯），当3次谐波电流超过（ ）时，应按N线电流选择电缆截面。",[72,74,76,78],{"key":20,"text":73,"correct":22},"15%;",{"key":24,"text":75,"correct":26},"33%;",{"key":28,"text":77,"correct":22},"45%；",{"key":31,"text":79,"correct":22},"50%。",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":20,"analysis":33},1032373,"电缆支架除支持单相工作电流大于（）的交流系统电缆情况外，宜用钢制。",[84,86,88,90],{"key":20,"text":85,"correct":26},"1500A；",{"key":24,"text":87,"correct":22},"500A ；",{"key":28,"text":89,"correct":22},"300A ；",{"key":31,"text":91,"correct":22},"100",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":24,"analysis":33},1032375,"变配电所的控制回路宜采用（）。",[96,98,100,102],{"key":20,"text":97,"correct":22},"控制开关自动复位的接线;",{"key":24,"text":99,"correct":26},"控制开关具有固定位置的接线；",{"key":28,"text":101,"correct":22},"分合按钮的接线；",{"key":31,"text":103,"correct":22},"带有灯光的分合按钮的接线。",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":20,"analysis":33},1032378,"对遥控及无人值班变配电所的控制回路宜采用（ ）。",[108,110,111,113],{"key":20,"text":109,"correct":26},"控制开关自动复位的接线；",{"key":24,"text":99,"correct":22},{"key":28,"text":112,"correct":22},"分合按钮的接线;",{"key":31,"text":103,"correct":22},{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":31,"analysis":33},1032381,"除谐波测量仪表以外，交流回路仪表的精确度等级，不应低于（ )级。",[118,120,122,124],{"key":20,"text":119,"correct":22},"0.5;",{"key":24,"text":121,"correct":22},"1.0；",{"key":28,"text":123,"correct":22},"1.5;",{"key":31,"text":125,"correct":26},"2.5",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},1032384,"仪表的测量范围和电流互感器变比的选择，宜满足当电力装置回路以额定值的条件 运行时，仪表的指示在标度尺的（ ）处。",[130,132,134,136],{"key":20,"text":131,"correct":22},"60%~100%;",{"key":24,"text":133,"correct":26},"70%~100%",{"key":28,"text":135,"correct":22},"80%~100%;",{"key":31,"text":137,"correct":22},"85%~100%。",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":33},1032386,"电量变送器应配用不低于（ ）级的电流互感器.",[142,144,146,147],{"key":20,"text":143,"correct":22},"0.2;",{"key":24,"text":145,"correct":26},"0.5；",{"key":28,"text":121,"correct":22},{"key":31,"text":148,"correct":22},"3.0。",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":24,"analysis":33},1032389,"2. 5级的常用测量仪表应配用不低于（ ）级的互感器。",[153,155,156,158],{"key":20,"text":154,"correct":22},"0. 5；",{"key":24,"text":121,"correct":26},{"key":28,"text":157,"correct":22},"1. 5；",{"key":31,"text":159,"correct":22},"2. 5。",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":28,"analysis":33},1032392,"某变电所的1OkV为经消弧线圈接地系统，对于其IOkV母线应安装（ ）电压表。",[164,166,168,170],{"key":20,"text":165,"correct":22},"只測母线线电压1只；",{"key":24,"text":167,"correct":22},"只测母线线电压3只；",{"key":28,"text":169,"correct":26},"測母线线电压1只和测相电压3只或经切换开关测相电压1只；",{"key":31,"text":171,"correct":22},"只测母线相电压3只.",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":28,"analysis":33},1032394,"高压侧为35kV及以上，低压侧为1200V及以上的主变压器测量有功功率应按安装 于（ ）的原则进行。",[176,178,180,182],{"key":20,"text":177,"correct":22},"A-双绕组主变压器的两側;",{"key":24,"text":179,"correct":22},"双绕组主变压器的低压侧；",{"key":28,"text":181,"correct":26},"三绕组主变压器的三侧；",{"key":31,"text":183,"correct":22},"三绕组联络变压器的中压和低压侧.",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":31,"analysis":33},1032397,"下列电力装置中，无需装设有功电能表的回路是（）。",[188,190,192,194],{"key":20,"text":189,"correct":22},"电力用户处的有功电量计量点；",{"key":24,"text":191,"correct":22},"电力系统中，1200V~1lOkV的线路；",{"key":28,"text":193,"correct":22},"专用旁路和兼用旁路的断路器回路；",{"key":31,"text":195,"correct":26},"并联电容器组。",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":31,"analysis":33},1032399,"下列电力装置中，无需装设无功电能表的是（ )。 A.电力用户处的无功电量计量点； B.电力系统中，3~1lOkV的线路； C专用旁路和兼用旁路的断路器回路；D.电力系统中，3~63kV的消弧线圈。",[200,201,202,203],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":28,"analysis":33},1032401,"电能计量用电流互感器的二次侧电流，当电力装置回路以额定值的条件运行吋时，宜 为电能表标定电流的（ ）。",[208,210,211,213],{"key":20,"text":209,"correct":22},"85%~100%;",{"key":24,"text":135,"correct":22},{"key":28,"text":212,"correct":26},"70%~100%;",{"key":31,"text":214,"correct":22},"60%~100%.",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":28,"analysis":33},1032403,"电力用户处电能计费点的计费电能表，应设置专用互感器的电压等级有（ ）。",[219,221,223,225],{"key":20,"text":220,"correct":22},"3~1OkV及以下；",{"key":24,"text":222,"correct":22},"35kV及以下；",{"key":28,"text":224,"correct":26},"63kV及以下；",{"key":31,"text":226,"correct":22},"1lOkV及以下.",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":24,"analysis":33},1032404,"月平均电量（ ）及以上的电力用户电能计量应采用0.5级的有功电能表.",[231,233,235,237],{"key":20,"text":232,"correct":22},"0.5XlO6kWh;",{"key":24,"text":234,"correct":26},"lX106kWh；",{"key":28,"text":236,"correct":22},"2X106kWh；",{"key":31,"text":238,"correct":22},"5X106kWh.",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":24,"analysis":33},1032414,"1.0级及2. 0级的电能表处电压降不得大于电压互感器额定二次电压的（ ）。",[243,245,247,249],{"key":20,"text":244,"correct":22},"0.25%；",{"key":24,"text":246,"correct":26},"0.5%;",{"key":28,"text":248,"correct":22},"1.0%,",{"key":31,"text":250,"correct":22},"1.5%。",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":24,"analysis":33},1032416,"测量仪表回路用的电流互感器选择应考虑使在正常负荷下指示在标尺的2\u002F3以上， 并应考虑过负荷运行时有适当的指示，因此，电流互感器的一次电流不小于（ ）倍变压器 的额定电流或线路的最大负荷电流。",[255,257,259,261],{"key":20,"text":256,"correct":22},"1.20;",{"key":24,"text":258,"correct":26},"1.25;",{"key":28,"text":260,"correct":22},"1.30;",{"key":31,"text":262,"correct":22},"1.35。",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":28,"analysis":33},1032418,"干式变压器800kVA, 10\u002F0. 4kV,下列保护可以不装的是（ ）。",[267,269,271,273],{"key":20,"text":268,"correct":22},"过电流保护；",{"key":24,"text":270,"correct":22},"电流速断保护；",{"key":28,"text":272,"correct":26},"瓦斯保护；",{"key":31,"text":274,"correct":22},"温度保护。",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":20,"analysis":33},1032420,"变压器400V侧中性线上装设电流互感器作为单相接地保护，需装设的情况 为（ ）。",[279,281,283,285],{"key":20,"text":280,"correct":26},"Yyn接线变压器；",{"key":24,"text":282,"correct":22},"Dyn接线变压器；",{"key":28,"text":284,"correct":22},"Zyn接线变压器；",{"key":31,"text":286,"correct":22},"Yyn接线变压器，高压侧过电流保护对低压侧单相接地灵敏度满足要求。",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":28,"analysis":33},1032422,"主变压器的接线为Ydll,当装设纵差保护时，电流互感器的接线应为（ ）。",[291,293,295,297],{"key":20,"text":292,"correct":22},"Yy;",{"key":24,"text":294,"correct":22},"Dd；",{"key":28,"text":296,"correct":26},"Dy;",{"key":31,"text":298,"correct":22},"Yd。",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":31,"analysis":33},1032424,"为节约投资，不接地系统，0.4MVA及以上,一次电压为1OkV及以下，绕组为三 角星形连接变压器，可采用（ ）式的过流保护。",[303,305,307,309],{"key":20,"text":304,"correct":22},"三相电流互感器三继电器；",{"key":24,"text":306,"correct":22},"三相电流互感器二继电器；",{"key":28,"text":308,"correct":22},"两相电流互感器二继电器；",{"key":31,"text":310,"correct":26},"两相电流互感器三继电器。",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":24,"analysis":33},1032425,"当电容器组中故障电容器切除到一定数量，引起电容器端电压超过（ ）额定电压 时，保护应将整组电容器断开。",[315,317,319,321],{"key":20,"text":316,"correct":22},"105%;",{"key":24,"text":318,"correct":26},"110%；",{"key":28,"text":320,"correct":22},"115%；",{"key":31,"text":322,"correct":22},"120%。",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":28,"analysis":33},1032427,"电容器内部故障及其引出线的短路，宜对每台电容器分别设专用熔断器，熔丝的额 定电流可为电容器额定电流的（ ）倍。 A. 1.3~1.5; B. 1.3~1.8; C 1.43~1.55; D. 17~2. O。",[327,328,329,330],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":20,"analysis":33},1032429,"根据需要，异步电动机应装低电压保护时，其电压定值一般为电动机额定电压 的（ ）。",[335,337,339,341],{"key":20,"text":336,"correct":26},"60%~70%;",{"key":24,"text":338,"correct":22},"60%~75%;",{"key":28,"text":340,"correct":22},"65%~75%;",{"key":31,"text":342,"correct":22},"70%~80%。",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":31,"analysis":33},1032431,"在电动机的接地保护中，如果单相接地电流为（ ）及以上时，保护装置动作于 跳闸。",[347,349,351,353],{"key":20,"text":348,"correct":22},"5A；",{"key":24,"text":350,"correct":22},"7A；",{"key":28,"text":352,"correct":22},"8A；",{"key":31,"text":354,"correct":26},"10A,",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":24,"analysis":33},1032433,"自动重合闸装置，下列要求错误的是（ ）。",[359,361,363,365],{"key":20,"text":360,"correct":22},"手动断开断路器时不应动作;",{"key":24,"text":362,"correct":26},"手动合闸于故障线路时允许重合一次；",{"key":28,"text":364,"correct":22},"断路器故障不应多次重合；",{"key":31,"text":366,"correct":22},"在断路器不允许实现自动重合闸时，应将自动重合闸闭锁。",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":20,"analysis":33},1032435,"对自动投入装置，要求错误的是（）。",[371,373,375,377],{"key":20,"text":372,"correct":26},"保证备用电源投入后工作回路才断开；",{"key":24,"text":374,"correct":22},"手动断开工作回路，不起动自动投入装里；",{"key":28,"text":376,"correct":22},"只动作一次；",{"key":31,"text":378,"correct":22},"备用电源投于故障上必要时应使保护加速动作。",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":20,"analysis":33},1032437,"Yyn变压器400V侧中性线上流过的最大不平衡电流，其值按国际标准规定，不超 过额定电流的（ ）。",[383,385,387,389],{"key":20,"text":384,"correct":26},"25%；",{"key":24,"text":386,"correct":22},"30%;",{"key":28,"text":388,"correct":22},"20%；",{"key":31,"text":390,"correct":22},"15%。",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":31,"analysis":33},1032438,"变配电所计箅机监控系统宜由站控层和（ ）两部分组成。",[395,397,399,401],{"key":20,"text":396,"correct":22},"设备层；",{"key":24,"text":398,"correct":22},"楼层；",{"key":28,"text":400,"correct":22},"房间层；",{"key":31,"text":402,"correct":26},"间隔层。",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":28,"analysis":33},1032440,"变配电所监控系统在站控层及网络层失效的情况下仍能独立完成设备间隔的（ ） 功能。",[407,409,411,413],{"key":20,"text":408,"correct":22},"远方遥控；",{"key":24,"text":410,"correct":22},"主控室集控；",{"key":28,"text":412,"correct":26},"就地监控；",{"key":31,"text":414,"correct":22},"易地控制。",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":31,"analysis":33},1032442,"1lOkV及以下变配电所监控系统可以采用（ ）。",[419,421,423,425],{"key":20,"text":420,"correct":22},"双环网；",{"key":24,"text":422,"correct":22},"单环网；",{"key":28,"text":424,"correct":22},"双网；",{"key":31,"text":426,"correct":26},"单网。",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":20,"analysis":33},1032444,"电力变压器电流速断保护的灵敏系数是根据（ ）的短路电流来校验。",[431,433,435,437],{"key":20,"text":432,"correct":26},"最小运行方式高压侧发生两相短路；",{"key":24,"text":434,"correct":22},"最大运行方式低压侧发生三相短路流经高压侧；",{"key":28,"text":436,"correct":22},"最小运行方式低压侧发生两相短路流经高压侧；",{"key":31,"text":438,"correct":22},"最大运行方式高压侧发生三相短路。",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":20,"analysis":33},1032446,"复合电压起动的过电流保护或低电压闭锁的过电流保护不宜用于（ 〉。",[443,445,447,449],{"key":20,"text":444,"correct":26},"单独的降压变压器；",{"key":24,"text":446,"correct":22},"升压变压器；",{"key":28,"text":448,"correct":22},"系统联络变压器；",{"key":31,"text":450,"correct":22},"过电流不符合灵敏性要求的降压变压器。",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":24,"analysis":33},1032448,"变压器过电流保护的灵敏系数最小应该等于（ ）。 A. 1.25; B. 1.5; C 1.75; D. 2,0。",[455,456,457,458],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":24,"analysis":33},1032449,"电力系统中因事故发生功率缺额时，应由（ ）断开一部分次要负荷。",[463,465,467,469],{"key":20,"text":464,"correct":22},"值班人员手动；",{"key":24,"text":466,"correct":26},"自动低频减载装置；",{"key":28,"text":468,"correct":22},"自动低电压减载装置；",{"key":31,"text":470,"correct":22},"调度员命令。",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":24,"analysis":33},1032451,"继电器屏的屏面布置不应出现的情况是（ ）。",[475,477,479,481],{"key":20,"text":476,"correct":22},"屏面布置适当紧凑；",{"key":24,"text":478,"correct":26},"不同安装单位的继电器装在一块屏上，宜按照横向划分；",{"key":28,"text":480,"correct":22},"设备或元件装设两套主保护装置时，宜分别布置在不同屏上；",{"key":31,"text":482,"correct":22},"单个继电器调整工作量较少的布置在屏的上部。",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":31,"analysis":33},1032453,"控制屏上采用灯光监视时，红、绿灯代表断路器的合闸与分闸状态，它们分别布置 在控制开关的（ ）。",[487,489,491,493],{"key":20,"text":488,"correct":22},"右下侧和左下侧；",{"key":24,"text":490,"correct":22},"左下倒和右下侧；",{"key":28,"text":492,"correct":22},"C左上侧和右上侧；",{"key":31,"text":494,"correct":26},"右上侧和左上侧。",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":28,"analysis":33},1032455,"屏上信号继电器宜集中布置，安装水平高度应一致，其安装中心线离地面不宜低 于（ ）。",[499,501,503,505],{"key":20,"text":500,"correct":22},"800mm；",{"key":24,"text":502,"correct":22},"700mm；",{"key":28,"text":504,"correct":26},"600mm ;",{"key":31,"text":506,"correct":22},"500mm。",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":24,"analysis":33},1032457,"变电所操作电源中弱电控制的电压一般为（ ）。",[511,513,515,517],{"key":20,"text":512,"correct":22},"72V及以下；",{"key":24,"text":514,"correct":26},"48V及以下；",{"key":28,"text":516,"correct":22},"24V及以下；",{"key":31,"text":518,"correct":22},"12V及以下.",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":20,"analysis":33},1032459,"突然断电比过负荷造成的损失更大的线路，其过负荷保护应（ ）。",[523,525,527,529],{"key":20,"text":524,"correct":26},"作用于信号而不应作用于切断电路；",{"key":24,"text":526,"correct":22},"作用于切断电路而不作用于信号；",{"key":28,"text":528,"correct":22},"同时作用于信号和切断电路；",{"key":31,"text":530,"correct":22},"延时0.5s切断短路。",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":24,"analysis":33},1032460,"变电所的直流回路仪表，其精确度等级不应低于（ ）级。",[535,536,537,539],{"key":20,"text":121,"correct":22},{"key":24,"text":123,"correct":26},{"key":28,"text":538,"correct":22},"2. O;",{"key":31,"text":540,"correct":22},"2.5。",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":31,"analysis":33},1032462,"变配电所的功率测量中，对同步电动机，应装设（ ）。",[545,547,549,551],{"key":20,"text":546,"correct":22},"有功电能表；",{"key":24,"text":548,"correct":22},"视在电能表；",{"key":28,"text":550,"correct":22},"无功电能表；",{"key":31,"text":552,"correct":26},"功率因数表。",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":20,"analysis":33},1032464,"需要进行技术经济考核的75kW及以上的电动机，其电能测量的有功电能表应为 ( )级.",[557,559,560,562],{"key":20,"text":558,"correct":26},"2.0;",{"key":24,"text":123,"correct":22},{"key":28,"text":561,"correct":22},"1.0,",{"key":31,"text":563,"correct":22},"0.5。",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":20,"analysis":33},1032466,"电能计量用互感器的精度等级，当有功电能表为0.5级时，配用的互感器等级应为 ( )级。",[568,569,571,572],{"key":20,"text":143,"correct":26},{"key":24,"text":570,"correct":22},"0.5,",{"key":28,"text":121,"correct":22},{"key":31,"text":573,"correct":22},"1.5。",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":24,"analysis":33},1032468,"仅作为企业内部技术经济考核而不是作计费用的2. 0级有功电能表及3.0级无功电 能表，宜配用的互感器等级为不低于（ ）级。",[578,580,581,583],{"key":20,"text":579,"correct":22},"0. 5;",{"key":24,"text":121,"correct":26},{"key":28,"text":582,"correct":22},"4.5;",{"key":31,"text":584,"correct":22},"2.0",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":20,"analysis":33},1032470,"电流互感器的二次回路一般不进行切换，但确实需要切换时，应采取防止（ ）的措施。",[589,591,593,595],{"key":20,"text":590,"correct":26},"开路； .",{"key":24,"text":592,"correct":22},"短路；",{"key":28,"text":594,"correct":22},"过负荷；",{"key":31,"text":596,"correct":22},"数据不准。",[598,601,604,607,610,613],{"id":15,"name":599,"category":7,"favorite":600},"领导干部任职前廉政法规知识测试题",92,{"id":602,"name":603,"category":7,"favorite":15},595,"建筑结构与设备",{"id":605,"name":606,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":608,"name":609,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":611,"name":612,"category":7,"favorite":8},534,"BIM工程师",{"id":614,"name":612,"category":7,"favorite":8},535]