[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":579},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,14,50,2321,[13,34,46,58,66,78,90,102,114,126,138,147,155,166,177,186,198,210,222,234,246,258,270,282,294,306,317,325,337,349,361,373,385,395,407,419,427,439,450,458,470,478,490,502,514,526,535,547,559,571],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1032225,1,"单选题","除交流系统用单芯电力电缆外，电力电缆在同一层支架上电缆排列配置时，相互间 宜有（ ）空隙。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","15mm；",false,{"key":24,"text":25,"correct":22},"B","25mm；",{"key":27,"text":28,"correct":22},"C","35mm；",{"key":30,"text":31,"correct":32},"D","不小于电缆外径。",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1032228,"热力管道与控制信号电缆交叉敷设时，其间距应为（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"150mm；",{"key":24,"text":41,"correct":32},"250mm；",{"key":27,"text":43,"correct":22},"350mm；",{"key":30,"text":45,"correct":22},"500mm.",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1032231,"在竖井中，宜每隔约（）设置阻火隔层。",[50,52,54,56],{"key":20,"text":51,"correct":22},"9m；",{"key":24,"text":53,"correct":32},"7m;",{"key":27,"text":55,"correct":22},"6m；",{"key":30,"text":57,"correct":22},"3m.",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},1032233,"室内裸导体布线距地高度不低于（ ）。 A. 2. 5m； B. 3. 0m； C 3. 5m; D. 4. 0m.",[62,63,64,65],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":22},{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":20,"analysis":33},1032235,"当室内棵导体采用防护等级不低于IP2X级的网状遮拦时，距地高度不低于（ ）。",[70,72,74,76],{"key":20,"text":71,"correct":32},"2. 5m；",{"key":24,"text":73,"correct":22},"3. Om；",{"key":27,"text":75,"correct":22},"3. 5m；",{"key":30,"text":77,"correct":22},"4. Om.",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":27,"analysis":33},1032238,"屋内直敷布线宜用护套绝缘导线，布线的固定点间距不应大于300mm,其截面不 宜大于（ ）。",[82,84,86,88],{"key":20,"text":83,"correct":22},"2. 5mm2 ；",{"key":24,"text":85,"correct":22},"4mm2 ；",{"key":27,"text":87,"correct":32},"6mm2 ；",{"key":30,"text":89,"correct":22},"10mm2。",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":30,"analysis":33},1032241,"3根以上绝缘导线穿同一根管时，导线的总截面不应大于管内净面积的40%,当管 子有3个弯（90°～105°)时，其长度不超过（ ）。",[94,96,98,100],{"key":20,"text":95,"correct":22},"30m;",{"key":24,"text":97,"correct":22},"20m；",{"key":27,"text":99,"correct":22},"15m；",{"key":30,"text":101,"correct":32},"8m。",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":20,"analysis":33},1032244,"控制线与动力线共管时，当线路较长或弯头较多时控制线截面不应小于动力线截 面的（ ）。",[106,108,110,112],{"key":20,"text":107,"correct":32},"10%；",{"key":24,"text":109,"correct":22},"15%;",{"key":27,"text":111,"correct":22},"30%;",{"key":30,"text":113,"correct":22},"40%.",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":24,"analysis":33},1032247,"母线槽距地面的距离不应小于（ ）。但安装在配电室、电气竖井等电气专用房间 时不受此限制。",[118,120,122,124],{"key":20,"text":119,"correct":22},"2m；",{"key":24,"text":121,"correct":32},"2. 2m;",{"key":27,"text":123,"correct":22},"2. 5m;",{"key":30,"text":125,"correct":22},"3. Om.",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},1032249,"3~lOkV高压架空线路铜绞线不应小于（ ）。",[130,132,134,136],{"key":20,"text":131,"correct":22},"10mm2 ；",{"key":24,"text":133,"correct":32},"16mm2 ；",{"key":27,"text":135,"correct":22},"25mm2 ；",{"key":30,"text":137,"correct":22},"35mm2 .",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":30,"analysis":33},1032252,"居民区内lOkV架空线路采用铝绞线及铝合金线时，最小截面积为（ ）。",[142,143,144,145],{"key":20,"text":131,"correct":22},{"key":24,"text":133,"correct":22},{"key":27,"text":135,"correct":22},{"key":30,"text":146,"correct":32},"35mm2。",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":30,"analysis":33},1032254,"35kV架空线路采用铝绞线及铝合金线时，最小截面积为（ ）。 A. 10mm2 ； B 16mm2 ； C. 25mm2 ； D. 35mm2",[151,152,153,154],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":32},{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":27,"analysis":33},1032257,"3~IOkV高压架空线距地面的距离不应小于（ ）。",[159,161,162,164],{"key":20,"text":160,"correct":22},"3. Om;",{"key":24,"text":75,"correct":22},{"key":27,"text":163,"correct":32},"4. 5m;",{"key":30,"text":165,"correct":22},"5. Om.",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":27,"analysis":33},1032260,"跨越道路、街道的低压接户线，在通车街道处至路面中心距离不应小于（ ）。",[170,171,173,175],{"key":20,"text":75,"correct":22},{"key":24,"text":172,"correct":22},"4. 5m；",{"key":27,"text":174,"correct":32},"6.0m;",{"key":30,"text":176,"correct":22},"8. Om.",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":20,"analysis":33},1032263,"1kV以下架空低压接户线距地面的距离不应小于（ ）。",[181,182,183,185],{"key":20,"text":71,"correct":32},{"key":24,"text":75,"correct":22},{"key":27,"text":184,"correct":22},"4.5m;",{"key":30,"text":165,"correct":22},{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":30,"analysis":33},1032265,"在离海岸（ ）以内的沿海地区或工业区，视腐蚀性气体和尘埃产生腐蚀作用的严 重程度，选用不同防腐性能的防腐型钢芯铝绞线。",[190,192,194,196],{"key":20,"text":191,"correct":22},"2km；",{"key":24,"text":193,"correct":22},"3km；",{"key":27,"text":195,"correct":22},"4km；",{"key":30,"text":197,"correct":32},"5km.",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":24,"analysis":33},1032268,"电缆隧道、工作井的净高，不宜小于（）。",[202,204,206,208],{"key":20,"text":203,"correct":22},"1800mm；",{"key":24,"text":205,"correct":32},"1900mm；",{"key":27,"text":207,"correct":22},"2000mm；",{"key":30,"text":209,"correct":22},"2500mm。",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":20,"analysis":33},1032271,"耐火电缆用于明敷有多根电缆配置中，或位于油罐区、熔化金属溅落等可能波及场 所时，其耐火性应符合GB\u002FT 12666—1990《电线电缆燃烧试验方法》的规定，并满足该标 准第6部分（）类的要求。",[214,216,218,220],{"key":20,"text":215,"correct":32},"A；",{"key":24,"text":217,"correct":22},"B；",{"key":27,"text":219,"correct":22},"C；",{"key":30,"text":221,"correct":22},"D。",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":24,"analysis":33},1032273,"用于耐火防护的材料产品，应按有效工程使用条件的燃烧试燃满足耐火极限不低于1h的要求，且耐火温度不宜低于（)。",[226,228,230,232],{"key":20,"text":227,"correct":22},"800℃;",{"key":24,"text":229,"correct":32},"1000℃;",{"key":27,"text":231,"correct":22},"1500℃；",{"key":30,"text":233,"correct":22},"2000℃。",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":27,"analysis":33},1032276,"电缆桥架水平敷设，宜按荷载曲线选取最佳跨距进行支撑，跨距一般为（ ）。 垂直敷设时，其固定点间距不宜大于2m。",[238,240,242,244],{"key":20,"text":239,"correct":22},"1.0~2. 0m;",{"key":24,"text":241,"correct":22},"1.5~2. 5m;",{"key":27,"text":243,"correct":32},"1. 5~3. 0m;",{"key":30,"text":245,"correct":22},"2. 0~3. 0m。",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":30,"analysis":33},1032279,"钢索上采用绝缘子吊装绝缘导线布线时，支持点间距不应大于1.5m。线间距离在 屋外不应小于（ )。",[250,252,254,256],{"key":20,"text":251,"correct":22},"30mm;",{"key":24,"text":253,"correct":22},"50mm;",{"key":27,"text":255,"correct":22},"80mm；",{"key":30,"text":257,"correct":32},"100mm。",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":24,"analysis":33},1032282,"旋转臂架式起重机的任何部位或被吊物边缘与1OkV以下的架空线路边线最小水平 距离不得小于（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"1m;",{"key":24,"text":265,"correct":32},"1.5m;",{"key":27,"text":267,"correct":22},"2m;",{"key":30,"text":269,"correct":22},"2.5m",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":27,"analysis":33},1032284,"施工现场开挖非热管道沟槽的边缘与埋地外电缆沟槽边缘之间的距离不得小 于（ ）",[274,276,278,280],{"key":20,"text":275,"correct":22},"0.1m;",{"key":24,"text":277,"correct":22},"0.3m;",{"key":27,"text":279,"correct":32},"0.5m;",{"key":30,"text":281,"correct":22},"1.0m。",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":30,"analysis":33},1032287,"橡皮电缆架空敷设时，应沿墙壁或电杆设置，并用绝缘子固定，严禁使用金属裸线 作绑线。固定点间距应保证橡皮电缆能承受自重所带来的荷重。橡皮电缆在最大弧垂时距地 不得小于（ ）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"1. Om;",{"key":24,"text":289,"correct":22},"1. 5m；",{"key":27,"text":291,"correct":22},"2. Om；",{"key":30,"text":293,"correct":32},"2. 5m。",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":24,"analysis":33},1032290,"沿不同冷却的路径敷设绝缘导线和电缆时，当冷却条件最坏段的长度超过（ ）， 应按该段条件选择绝缘导线和电缆的截面，或只对该段采用大截面的绝缘导线和电缆。",[298,300,302,304],{"key":20,"text":299,"correct":22},"3m;",{"key":24,"text":301,"correct":32},"5m；",{"key":27,"text":303,"correct":22},"10m；",{"key":30,"text":305,"correct":22},"15m。",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":27,"analysis":33},1032293,"35kV与1OkV同杆塔共架的线路，不同电压等级导线间的垂直距离不应小 于（ ）。",[310,312,313,315],{"key":20,"text":311,"correct":22},"lm；",{"key":24,"text":289,"correct":22},{"key":27,"text":314,"correct":32},"2. Om;",{"key":30,"text":316,"correct":22},"2. 5m。.",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":27,"analysis":33},1032296,"与防空 地下室无关的管道，不宜穿过人防围护结构。当因条件限制电缆管需要穿过其顶板时，凡进入防空地下室的管道及其穿过的人防围护结构，均应采取防护密闭措施，且 其公称直径不得大于（）。 A. 35mm； B. 50mm; C 75mm； D. 100mm。",[321,322,323,324],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":22},{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":27,"analysis":33},1032299,"选择导体时，应按（ ）条件校核。",[329,331,333,335],{"key":20,"text":330,"correct":22},"温度、湿度；",{"key":24,"text":332,"correct":22},"风速；",{"key":27,"text":334,"correct":32},"环境；",{"key":30,"text":336,"correct":22},"污秽、海拔。",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":20,"analysis":33},1032301,"导体正常工作温度不应超过（ ），在计及日照影响时，钢芯铝线及管型导体可按 不超过（ ）。当导体接触面处有镀（搪）锡的可靠覆盖层时，可提高到（ ）。",[341,343,345,347],{"key":20,"text":342,"correct":32},"+70℃, +80℃, +85℃；",{"key":24,"text":344,"correct":22},"+45℃, +70℃, +80℃；",{"key":27,"text":346,"correct":22},"+70℃, +85℃, +90℃;",{"key":30,"text":348,"correct":22},"+85℃, +90℃；, +110℃。",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":20,"analysis":33},1032304,"按回路正常工作电流选择导体截面时，导体的长期允许载流量应按（）进行 修正。",[353,355,357,359],{"key":20,"text":354,"correct":32},"所在地区海拔及环境温度；",{"key":24,"text":356,"correct":22},"所在地区海拔及环境湿度；",{"key":27,"text":358,"correct":22},"所在地区污秽及环境湿度；",{"key":30,"text":360,"correct":22},"所在地区污秽及环境温度。",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":24,"analysis":33},1032307,"按经济电流密度选择导体截面时，如无合适规格导体时，导体面积可按经济电流密 度计箅截面的相邻（ ）选取。",[365,367,369,371],{"key":20,"text":366,"correct":22},"上一档；",{"key":24,"text":368,"correct":32},"下一档；",{"key":27,"text":370,"correct":22},"上二档；",{"key":30,"text":372,"correct":22},"下二档。",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},1032309,"矩形导体的搭接长度不应（）导体的宽度。",[377,379,381,383],{"key":20,"text":378,"correct":22},"大于；",{"key":24,"text":380,"correct":32},"小于；",{"key":27,"text":382,"correct":22},"等于；",{"key":30,"text":384,"correct":22},"大于等于。",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":27,"analysis":33},1032312,"为消除由于温度变化引起的危险应力，矩形硬铝导体的直线段一般每隔（ ）左 右安装一个伸缩接头。",[389,390,392,393],{"key":20,"text":99,"correct":22},{"key":24,"text":391,"correct":22},"30m；",{"key":27,"text":97,"correct":32},{"key":30,"text":394,"correct":22},"25m。",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":20,"analysis":33},1032315,"封闭母线和电器的连接处，导体和外壳应设置（ ）的伸缩接头。",[399,401,403,405],{"key":20,"text":400,"correct":32},"可拆卸；",{"key":24,"text":402,"correct":22},"不可拆卸；",{"key":27,"text":404,"correct":22},"焊接；",{"key":30,"text":406,"correct":22},"铆接。",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":24,"analysis":33},1032318,"当封闭母线的直线段长度在（ ）左右及有可能发生不同沉陷的场所，导体和外 壳宜设置（）伸缩接头。",[411,413,415,417],{"key":20,"text":412,"correct":22},"30m,可拆卸的；",{"key":24,"text":414,"correct":32},"20m,不可拆卸的；",{"key":27,"text":416,"correct":22},"20m,可拆卸的；",{"key":30,"text":418,"correct":22},"30m,不可拆卸的。",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":24,"analysis":33},1032319,"控制电缆应采用（ ）。 A.铝芯； B.铜芯;C钢芯； D.光纤。",[423,424,425,426],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":32},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":20,"analysis":33},1032322,"交流系统中电力电缆缆芯的相间额定电压，不得低于使用回路的工作（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":32},"线电压；",{"key":24,"text":434,"correct":22},"相电压；",{"key":27,"text":436,"correct":22},"工频过电压；",{"key":30,"text":438,"correct":22},"冲击电压。",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":24,"analysis":33},1032325,"交流系统中电缆的（ ）耐压水平，应满足系统绝缘配合要求。",[443,445,447,448],{"key":20,"text":444,"correct":22},"Imin工频；",{"key":24,"text":446,"correct":32},"冲击；",{"key":27,"text":432,"correct":22},{"key":30,"text":449,"correct":22},"相电压。",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":24,"analysis":33},1032328,"用于中、高压回路的交联聚乙烯电缆，应选用属于具备（ ）特性的绝缘构造 型式。 A.耐高温； B.耐水树； C耐腐蚀； D.耐潮.",[454,455,456,457],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":32},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":27,"analysis":33},1032330,"移动式电气设备等需经常弯移或有较高柔软性要求回路的电缆，应选用的外护层 为（ ）。",[462,464,466,468],{"key":20,"text":463,"correct":22},"A聚氯乙烯；",{"key":24,"text":465,"correct":22},"聚乙烯；",{"key":27,"text":467,"correct":32},"橡皮；",{"key":30,"text":469,"correct":22},"氯磺化聚乙烯。",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":20,"analysis":33},1032333,"弱电回路的每一对往返导线，宜属于（ ）控制电缆。 A.同一根.； B.不同的； C.相同的。",[474,475,476,477],{"key":20,"text":20,"correct":32},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},1032335,"在户内电缆沟、隧道敷设并无机械通风的情况下，确定电缆持续允许载流量的环 境温度为（ ）。",[482,484,486,488],{"key":20,"text":483,"correct":22},"年平均最高温度；",{"key":24,"text":485,"correct":32},"最热月的日最高温度平均值加5℃;",{"key":27,"text":487,"correct":22},"年平均最低温度；",{"key":30,"text":489,"correct":22},"最热月的日最高温度平均值。",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":24,"analysis":33},1032338,"交流供电回路由多根电缆并联组成时，宜采用（ ）截面。",[494,496,498,500],{"key":20,"text":495,"correct":22},"不同；",{"key":24,"text":497,"correct":32},"相同;",{"key":27,"text":499,"correct":22},"任意组合；",{"key":30,"text":501,"correct":22},"多种。",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":24,"analysis":33},1032341,"6kV交联聚乙稀绝缘电缆的允许弯曲半径一般为（）倍电缆外径。",[506,508,510,512],{"key":20,"text":507,"correct":22},"10；",{"key":24,"text":509,"correct":32},"15,",{"key":27,"text":511,"correct":22},"8；",{"key":30,"text":513,"correct":22},"12,",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":24,"analysis":33},1032344,"绝缘铜芯导线穿管敷设时，最小芯线截面为（）。",[518,520,522,524],{"key":20,"text":519,"correct":22},"0. 75mm2 ；",{"key":24,"text":521,"correct":32},"1.0mm2;",{"key":27,"text":523,"correct":22},"1.5mm2;",{"key":30,"text":525,"correct":22},"2. 5mm2。",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":20,"analysis":33},1032346,"绝缘铜芯导线在线槽内敷设时，最小芯线截面为（）。",[530,531,532,533],{"key":20,"text":519,"correct":32},{"key":24,"text":521,"correct":22},{"key":27,"text":523,"correct":22},{"key":30,"text":534,"correct":22},"2.5mm2。",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":20,"analysis":33},1032349,"在单相二线制线路中，N线（中性线）截面为相线截面的（）。",[539,541,543,545],{"key":20,"text":540,"correct":32},"100%；",{"key":24,"text":542,"correct":22},"150%；",{"key":27,"text":544,"correct":22},"200%;",{"key":30,"text":546,"correct":22},"按谐波电流确定。",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":30,"analysis":33},1032351,"在三相四线制线路中，N线截面选择为（）。",[551,553,555,557],{"key":20,"text":552,"correct":22},"不小于相线截面的30%;",{"key":24,"text":554,"correct":22},"不小于相线截面；",{"key":27,"text":556,"correct":22},"不小于相线截面的200%;",{"key":30,"text":558,"correct":32},"N线的允许载流量不小于最大不平衡电流，并计入谐波的影响。",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":24,"analysis":33},1032354,"在三相四线制配电系统中，对N线电流影响最大的谐波是（ ）次谐波。",[563,565,567,569],{"key":20,"text":564,"correct":22},"2;",{"key":24,"text":566,"correct":32},"3;",{"key":27,"text":568,"correct":22},"5；",{"key":30,"text":570,"correct":22},"7。",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":24,"analysis":33},1032357,"在TN—C接地系统中，采用多芯铜电缆中的芯线作PEN线干线时，其截面不应 小于（ ）。 A. 2. 5mm2 ； B. 4mm2C 6mm2 ； D.1Omm2.",[575,576,577,578],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":32},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},[580,583,586,589,592,595],{"id":15,"name":581,"category":7,"favorite":582},"领导干部任职前廉政法规知识测试题",92,{"id":584,"name":585,"category":7,"favorite":15},595,"建筑结构与设备",{"id":587,"name":588,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":590,"name":591,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":593,"name":594,"category":7,"favorite":8},534,"BIM工程师",{"id":596,"name":594,"category":7,"favorite":8},535]