[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":605},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,13,50,2321,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,358,370,382,394,406,418,430,442,454,466,477,486,495,507,519,531,539,549,559,570,582,594],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1032091,1,"单选题","电缆型号由拼音及数字组成，铝芯交联聚乙烯绝缘聚氯乙烯护套阻燃钢带铠装的电 缆型号为（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","YJLV22；",false,{"key":24,"text":25,"correct":26},"B","ZR—YJLV22；",true,{"key":28,"text":29,"correct":22},"C","ZR—YJV;",{"key":31,"text":32,"correct":22},"D","ZR — YJLV32.","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1032094,"型号为KYJV代表（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"交联聚乙烯绝缘聚氯乙烯护套控制电缆；",{"key":24,"text":41,"correct":22},"铜芯交联聚乙烯绝缘聚乙烯护套控制电缆；",{"key":28,"text":43,"correct":22},"聚乙烯绝缘交联聚乙烯护套控制电缆；",{"key":31,"text":45,"correct":22},"聚氯乙烯绝缘交联聚乙烯护套控制电缆。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1032097,"一般不采用铜芯的电缆是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"水下敷设工作电流较大的电力电缆；",{"key":24,"text":53,"correct":26},"—般用途的电力电缆；",{"key":28,"text":55,"correct":22},"移动式电气设备用电缆；",{"key":31,"text":57,"correct":22},"控制电缆。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1032100,"用于中性点直接接地或经低电阻接地系统、保护动作切除故障在60s以内的电力电 缆，其缆芯与金属套间额定电压不应低于工作相电压的（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"100%；",{"key":24,"text":65,"correct":22},"133%；",{"key":28,"text":67,"correct":22},"173%;",{"key":31,"text":69,"correct":22},"200%。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},1032103,"低温环境下不宜用的电缆是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"油浸纸绝缘；",{"key":24,"text":77,"correct":22},"交联聚乙烯绝缘；",{"key":28,"text":79,"correct":22},"耐寒橡皮电缆；",{"key":31,"text":81,"correct":26},"聚氯乙烯绝缘。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1032106,"选择硬导体形状时不需考虑的因素是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"集肤效应；",{"key":24,"text":89,"correct":22},"热屏蔽效应；",{"key":28,"text":91,"correct":22},"电晕；",{"key":31,"text":93,"correct":26},"腐蚀性气体。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1032108,"在下列情形中导体可以不设伸缩接头的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"硬母线与主变压器端子连接处；",{"key":24,"text":101,"correct":26},"硬母线长度不超过30m时；",{"key":28,"text":103,"correct":22},"支持基础不均匀下沉；",{"key":31,"text":105,"correct":22},"在地震基本烈度超过7度的地区，屋外配电装置电气设备之间的连接。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1032110,"下列因索不是敞露式大电流母线附近钢构发热的主要原因的是（) .",[110,112,114,116],{"key":20,"text":111,"correct":26},"钢构的防腐涂层；",{"key":24,"text":113,"correct":22},"涡流；",{"key":28,"text":115,"correct":22},"磁滞损耗；",{"key":31,"text":117,"correct":22},"环流;",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1032113,"高压配电装置硬导体材料一般可用铝合金，使用铜材的情况是（ ).",[122,124,126,128],{"key":20,"text":123,"correct":22},"位于市区；",{"key":24,"text":125,"correct":26},"化工厂附近；",{"key":28,"text":127,"correct":22},"工作电流在3000A以下；",{"key":31,"text":129,"correct":22},"地震多发区。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},1032116,"高压配电装置硬导体型式有矩形、槽形、管形，恰当的是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"工作电流≤4000A选单片矩形；",{"key":24,"text":137,"correct":22},"工作电流≥4000A选多片矩形；",{"key":28,"text":139,"correct":22},"工作电流≥8000A选槽形；",{"key":31,"text":141,"correct":26},"35kV及以上户外配电装置采用管形。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1032119,"硬导体选择要按短路电流校验动稳定，与其无关的有（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"导体材料的最大允许应力；",{"key":24,"text":149,"correct":26},"导体材料的温度系数；",{"key":28,"text":151,"correct":22},"支持绝缘于间的跨距及相间距；",{"key":31,"text":153,"correct":22},"三相导体排列方式。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},1032122,"大电流三相母线不对称排列的条件下，对可不采用换位措施的描述，错误的 是（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"不平衡电压不超过2%。",{"key":24,"text":161,"correct":22},"单回距离不超过300~400m时；",{"key":28,"text":163,"correct":22},"夹固的封闭母线；",{"key":31,"text":165,"correct":26},"支持点适应加装伸缩接头。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":31,"analysis":33},1032123,"高压配电装置软导线截面选择的一般原则为（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"根据回路负荷电流选择；",{"key":24,"text":173,"correct":22},"根据电晕放电条件选择；",{"key":28,"text":175,"correct":22},"根据腐蚀气体影响选择；",{"key":31,"text":177,"correct":26},"A+B+C。’",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":31,"analysis":33},1032126,"有效防止电晕放电的措施为（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"使用钢芯铝绞线；",{"key":24,"text":185,"correct":22},"使用铝绞线；",{"key":28,"text":187,"correct":22},"C使用槽形导体；",{"key":31,"text":189,"correct":26},"使用分裂导线。",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":28,"analysis":33},1032129,"电缆直埋敷设时，不符合要求的做法是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"在电缆全线上方敷设混凝土保护板；",{"key":24,"text":197,"correct":22},"电缆转弯处在地面加标志处；",{"key":28,"text":199,"correct":26},"埋深不小于0.5m;",{"key":31,"text":201,"correct":22},"直埋的电缆上下左右回填不小于0. lm的软土或砂层。",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},1032132,"电缆与直流电气化铁路路轨最小平行距离是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"25m；",{"key":24,"text":209,"correct":26},"10m；",{"key":28,"text":211,"correct":22},"15m；",{"key":31,"text":213,"correct":22},"20m。",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":24,"analysis":33},1032135,"直埋电缆的接头与相邻电缆的净距不应小于（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"0.1m;",{"key":24,"text":221,"correct":26},"0.25m;",{"key":28,"text":223,"correct":22},"0. 5m；",{"key":31,"text":225,"correct":22},"1.0m。",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":31,"analysis":33},1032137,"直埋电缆遇到斜坡地形处的接头安置应（ ）.",[230,232,234,236],{"key":20,"text":231,"correct":22},"在斜坡以上平坦处；",{"key":24,"text":233,"correct":22},"在斜坡以下平坦处；",{"key":28,"text":235,"correct":22},"在斜坡段接头坡度一致；",{"key":31,"text":237,"correct":26},"在斜坡段接头要水平。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},1032139,"电缆敷设于保护管中时，正确的规定是（ ）.",[242,244,246,248],{"key":20,"text":243,"correct":26},"管内径不宜小于电缆外径的1.5倍；",{"key":24,"text":245,"correct":22},"管内径不小于电缆外径的2.0倍;",{"key":28,"text":247,"correct":22},"管顶距地面不小于0.8m;",{"key":31,"text":249,"correct":22},"并列管之间应保持0. 5m的间距。",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":20,"analysis":33},1032142,"电缆地下敷设时，在浅水区及深水航道区最小埋深分别为（ ）。",[254,256,258,260],{"key":20,"text":255,"correct":26},"0. 5m, 2.0m;",{"key":24,"text":257,"correct":22},"1.0m，2.0m;",{"key":28,"text":259,"correct":22},"0.5m，1.5m;",{"key":31,"text":261,"correct":22},"1.0m, 2. 5m.",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},1032145,"同一层支架上电缆排列配置方式不符合规定的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"控制和信号电缆可紧靠或多层迭置：",{"key":24,"text":269,"correct":26},"同一回路多根电力电缆可以迭置；",{"key":28,"text":271,"correct":22},"交流系统用单芯电力电缆的同一回路可采用品字形配置；",{"key":31,"text":273,"correct":22},"控制电缆与电力电缆尽可能不同层布置。",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":28,"analysis":33},1032148,"35kV以上高压电缆明敷时，普通支架、吊架水平跨距及垂直跨距分别为（ ).",[278,280,282,284],{"key":20,"text":279,"correct":22},"0.8m, 1.5m;",{"key":24,"text":281,"correct":22},"0.8m, 1.2m;",{"key":28,"text":283,"correct":26},"1. 5m, 3.0m;",{"key":31,"text":285,"correct":22},"1.0m, 3.0m.",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":28,"analysis":33},1032151,"电缆固定用部件的选择，不符合规定的是（ ）。",[290,292,294,296],{"key":20,"text":291,"correct":22},"三芯电力电缆可用扁钢制夹具；",{"key":24,"text":293,"correct":22},"不得用铁丝直接捆扎电缆；",{"key":28,"text":295,"correct":26},"交流单芯电力电缆的刚性固定可采用钢质夹具；",{"key":31,"text":297,"correct":22},"强腐蚀环境应采用尼龙扎帝或镀塑金属扎带.",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":20,"analysis":33},1032153,"下列关于电缆支架描述不正确的是（ ）。",[302,304,306,308],{"key":20,"text":303,"correct":26},"支持工作电流大于1500A的交流系统单芯电缆的支架宜用钢制;",{"key":24,"text":305,"correct":22},"金属制的电缆支架应有防腐蚀处理；",{"key":28,"text":307,"correct":22},"电缆支架应符合工程防火要求；",{"key":31,"text":309,"correct":22},"金属制桥架系统，应有可靠的电气连接并接地。",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":31,"analysis":33},1032155,"在隧道或电缆沟中不需设置防火墙的部位是（）。",[314,316,318,320],{"key":20,"text":315,"correct":22},"公用主沟道的分支处；",{"key":24,"text":317,"correct":22},"沟道中通风区段处；",{"key":28,"text":319,"correct":22},"至控制室的沟道入口处；",{"key":31,"text":321,"correct":26},"沟道中相隔约100m处.",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":20,"analysis":33},1032158,"阻火墙应满足按等效工程条件下标准试验的耐火极限不低于（).",[326,328,330,332],{"key":20,"text":327,"correct":26},"lh;",{"key":24,"text":329,"correct":22},"2h;",{"key":28,"text":331,"correct":22},"3h,",{"key":31,"text":333,"correct":22},"4h.",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":31,"analysis":33},1032161,"配电干线采用单芯电缆作保护中性线（简称PEN线）时，铜材截面不应小于 ( )mm2;为铝材时不应小于（ ）mm2;采用多芯电缆的干线其PEN线截面不应小于 ( )mm2.",[338,340,342,344],{"key":20,"text":339,"correct":22},"6，10, 2.5;",{"key":24,"text":341,"correct":22},"10，16, 2.5;",{"key":28,"text":343,"correct":22},"6，16, 4；",{"key":31,"text":345,"correct":26},"10，16，4。",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":33},1032164,"35kV及以下电缆允许载流量的基准温度，空气中为（ ），土壤中为（ ）.",[350,352,354,356],{"key":20,"text":351,"correct":22},"35℃, 20℃；",{"key":24,"text":353,"correct":26},"40℃, 25℃；",{"key":28,"text":355,"correct":22},"30℃ , 15℃；",{"key":31,"text":357,"correct":22},"40℃ , 20℃。",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},1032167,"自容式铝包充油电缆，允许弯曲半径可按电缆外径的（ ）倍计箅。",[362,364,366,368],{"key":20,"text":363,"correct":22},"6；",{"key":24,"text":365,"correct":26},"20;",{"key":28,"text":367,"correct":22},"12；",{"key":31,"text":369,"correct":22},"15。",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":20,"analysis":33},1032169,"电缆与热力管道之间无隔板防护，交叉敷设的，允许距离为（）。",[374,376,378,380],{"key":20,"text":375,"correct":26},"500mm；",{"key":24,"text":377,"correct":22},"1200mm；",{"key":28,"text":379,"correct":22},"800mm；",{"key":31,"text":381,"correct":22},"1000mm.",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":31,"analysis":33},1032171,"直埋敷设的电缆与公路交叉时，应穿保护管，且保护范围应超出路基（ ）以上。",[386,388,390,392],{"key":20,"text":387,"correct":22},"1.5m;",{"key":24,"text":389,"correct":22},"1.0m;",{"key":28,"text":391,"correct":22},"1. 2m；",{"key":31,"text":393,"correct":26},"0.5m。",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":20,"analysis":33},1032174,"单根电缆保护管使用时，每路不宜超过（ ）个弯头。",[398,400,402,404],{"key":20,"text":399,"correct":26},"3；",{"key":24,"text":401,"correct":22},"4；",{"key":28,"text":403,"correct":22},"5；",{"key":31,"text":405,"correct":22},"2。",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":24,"analysis":33},1032177,"控制电缆额定电压，使之不低于该回路的工作电压、满足可能经受的暂态和工频过 电压作用要求，一般宜选用（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"300\u002F500V;",{"key":24,"text":413,"correct":26},"450\u002F750V；",{"key":28,"text":415,"correct":22},"600\u002F1000V；",{"key":31,"text":417,"correct":22},"220\u002F380V。",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":24,"analysis":33},1032180,"( )以上高温场所，应按经受高温及其持续时间和绝缘类型要求，选用耐热聚氯 乙烯、普通交联聚乙烯、辐照式交联聚乙烯或乙丙橡皮绝缘等适合的耐热型电缆。",[422,424,426,428],{"key":20,"text":423,"correct":22},"50℃；",{"key":24,"text":425,"correct":26},"60℃；",{"key":28,"text":427,"correct":22},"70℃",{"key":31,"text":429,"correct":22},"90℃。",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":31,"analysis":33},1032183,"( )以上高温环境，宜选用矿物绝缘电缆。",[434,436,438,440],{"key":20,"text":435,"correct":22},"60℃：",{"key":24,"text":437,"correct":22},"70℃：",{"key":28,"text":439,"correct":22},"90℃；",{"key":31,"text":441,"correct":26},"100℃,",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":24,"analysis":33},1032186,"低温（）以下环境，应按低温条件和绝缘类型要求，选用油浸纸绝缘类或交联聚乙烯、聚乙烯绝缘、耐寒橡皮绝缘电缆。",[446,448,450,452],{"key":20,"text":447,"correct":22},"-10℃；",{"key":24,"text":449,"correct":26},"-20℃；",{"key":28,"text":451,"correct":22},"-25℃ ；",{"key":31,"text":453,"correct":22},"— 30℃。",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":28,"analysis":33},1032187,"髙温场所不宜用（ ）。",[458,460,462,464],{"key":20,"text":459,"correct":22},"耐热聚氯乙烯电缆；",{"key":24,"text":461,"correct":22},"普通交联聚乙烯电缆；",{"key":28,"text":463,"correct":26},"聚氯乙烯绝缘电缆；",{"key":31,"text":465,"correct":22},"乙丙橡皮绝缘电缆。",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":20,"analysis":33},1032190,"橡皮绝缘电线（500V)线芯允许长期工作温度为（ ）。",[470,472,474,475],{"key":20,"text":471,"correct":26},"65℃；",{"key":24,"text":473,"correct":22},"70℃；",{"key":28,"text":439,"correct":22},{"key":31,"text":476,"correct":22},"105℃。",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":28,"analysis":33},1032193,"交联聚乙烯绝缘电力电缆（1~10kV)线芯允许长期工作温度为（ )。",[481,482,483,485],{"key":20,"text":471,"correct":22},{"key":24,"text":473,"correct":22},{"key":28,"text":484,"correct":26},"90℃;",{"key":31,"text":476,"correct":22},{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":24,"analysis":33},1032196,"塑料绝缘电线（500V)线芯允许长期工作温度为（ ）。",[490,491,492,493],{"key":20,"text":471,"correct":22},{"key":24,"text":473,"correct":26},{"key":28,"text":439,"correct":22},{"key":31,"text":494,"correct":22},"105℃",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":24,"analysis":33},1032199,"电线穿钢管在空气中2根并列靠墙敷设时载流量的校正系数为（ ）。",[499,501,503,505],{"key":20,"text":500,"correct":22},"0.7;",{"key":24,"text":502,"correct":26},"0.8；",{"key":28,"text":504,"correct":22},"0.9;",{"key":31,"text":506,"correct":22},"0.95。",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":31,"analysis":33},1032202,"直埋敷设土壤热阻系数为0. 8K * m\u002FW时，电缆截面为120mm2,其载流量的校正 系数为（ ）。",[511,513,515,517],{"key":20,"text":512,"correct":22},"0.75;",{"key":24,"text":514,"correct":22},"0.87;",{"key":28,"text":516,"correct":22},"0.93;",{"key":31,"text":518,"correct":26},"1.05。",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":20,"analysis":33},1032203,"当额定电流630A以上时，推荐采用（ ）。",[523,525,527,529],{"key":20,"text":524,"correct":26},"密集絶缘型母线槽；",{"key":24,"text":526,"correct":22},"空气绝缘型母线槽；",{"key":28,"text":528,"correct":22},"插接式母线槽；",{"key":31,"text":530,"correct":22},"滑接式母线槽。",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":24,"analysis":33},1032206,"聚氯乙烯绝缘电力电缆（1~6kV)线芯允许长期工作温度为（ ）。",[535,536,537,538],{"key":20,"text":471,"correct":22},{"key":24,"text":473,"correct":26},{"key":28,"text":439,"correct":22},{"key":31,"text":476,"correct":22},{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":24,"analysis":33},1032209,"不带分接装置的，将电能直接从电源处送到配电中心的母线槽是（ ）。",[543,545,547,548],{"key":20,"text":544,"correct":22},"密集式母线槽；",{"key":24,"text":546,"correct":26},"馈电式母线槽；",{"key":28,"text":528,"correct":22},{"key":31,"text":530,"correct":22},{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":28,"analysis":33},1032212,"在空气中，电线穿钢管4根并列单层敷设在无孔托盘上时载流量的校正系数 为（ ）。",[553,555,557,558],{"key":20,"text":554,"correct":22},"0.7；",{"key":24,"text":556,"correct":22},"0.8;",{"key":28,"text":512,"correct":26},{"key":31,"text":506,"correct":22},{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":31,"analysis":33},1032215,"直埋敷设土壤热阻系数为1. 5K · m\u002FW时，电缆截面为120mm2,其载流量的校正系数为（）。",[563,564,566,568],{"key":20,"text":512,"correct":22},{"key":24,"text":565,"correct":22},"0. 86；",{"key":28,"text":567,"correct":22},"0. 92；",{"key":31,"text":569,"correct":26},"0.93。",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":28,"analysis":33},1032218,"除交流系统用单芯电力电缆的同一回路可采取品字形（三叶形）配置外，对重要的 同一回路多根电力电缆在同一层支架上电缆排列配置时，（）迭置。",[574,576,578,580],{"key":20,"text":575,"correct":22},"不得；",{"key":24,"text":577,"correct":22},"可以；",{"key":28,"text":579,"correct":26},"不宜；",{"key":31,"text":581,"correct":22},"不应.",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":31,"analysis":33},1032219,"明敷的电缆不宜平行敷设于热力管道上部。当必须平行热力管道敷设，且电缆与热 力管道之间无隔板防护时，其间距应为（）。",[586,588,590,592],{"key":20,"text":587,"correct":22},"100mm；",{"key":24,"text":589,"correct":22},"250mm；",{"key":28,"text":591,"correct":22},"500mm;",{"key":31,"text":593,"correct":26},"1000mm。",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":28,"analysis":33},1032222,"当电缆平行其他管道敷设，且电缆与管道之间无隔板防护时，其间距应为（ ）。",[598,600,601,603],{"key":20,"text":599,"correct":22},"50mm;",{"key":24,"text":587,"correct":22},{"key":28,"text":602,"correct":26},"150mm;",{"key":31,"text":604,"correct":22},"200mm。",[606,609,612,615,618,621],{"id":15,"name":607,"category":7,"favorite":608},"领导干部任职前廉政法规知识测试题",92,{"id":610,"name":611,"category":7,"favorite":15},595,"建筑结构与设备",{"id":613,"name":614,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":616,"name":617,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":619,"name":620,"category":7,"favorite":8},534,"BIM工程师",{"id":622,"name":620,"category":7,"favorite":8},535]