[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":558},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,12,50,2321,[13,30,42,52,61,69,81,93,104,115,123,135,143,153,161,173,185,197,205,217,226,234,246,253,265,276,286,296,308,316,323,334,345,356,366,378,390,402,414,426,438,450,462,474,486,498,510,522,534,546],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":29},1031956,1,"单选题","直接起动的笼型电动机的末端回路，用断路器保护，其瞬时过电流脱扣器整定电流 不应小于电动机起动电流的（ ）倍。 A. 1.0； B. 1.1 C 1.3； D. 2.0~2. 5。",[19,22,24,26],{"key":20,"text":20,"correct":21},"A",false,{"key":23,"text":23,"correct":21},"B",{"key":25,"text":25,"correct":21},"C",{"key":27,"text":27,"correct":28},"D",true,"",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":32,"options":33,"answer":20,"analysis":29},1031959,"用NT (RT16)型熔断器保护供荧光灯的照明配电线路，其熔体额定电流不应小于 线路计箅电流的（）倍。",[34,36,38,40],{"key":20,"text":35,"correct":28},"1.0；",{"key":23,"text":37,"correct":21},"1.2;",{"key":25,"text":39,"correct":21},"1.3;",{"key":27,"text":41,"correct":21},"1.6。",{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":23,"analysis":29},1031961,"用NT型熔断器保护供高压钠灯的照明配电线路，其熔体额定电流不应小于线路计 箅电流的（）倍。",[46,48,50,51],{"key":20,"text":47,"correct":21},"1.0,",{"key":23,"text":49,"correct":28},"1.2",{"key":25,"text":39,"correct":21},{"key":27,"text":41,"correct":21},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":20,"analysis":29},1031964,"用断路器保护供荧光灯的照明配电线路，其长延时过电流脱扣器整定电流不应小于 线路计箅电流的（）倍。",[56,58,59,60],{"key":20,"text":57,"correct":28},"1.0;",{"key":23,"text":37,"correct":21},{"key":25,"text":39,"correct":21},{"key":27,"text":41,"correct":21},{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":23,"analysis":29},1031967,"用断路器保护供金卤灯的照明配电线路，其瞬时过电流脱扣器整定电流不应小于线 路计箅电流的（ ）倍. A. 2~3; B. 4~7; C 8~10; D. 10~12。",[65,66,67,68],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":25,"analysis":29},1031969,"低压电器是指工频交流额定电压为（ ）及以下的电器.",[73,75,77,79],{"key":20,"text":74,"correct":21},"400V；",{"key":23,"text":76,"correct":21},"750V；",{"key":25,"text":78,"correct":28},"1000V；",{"key":27,"text":80,"correct":21},"1200V.",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":23,"analysis":29},1031972,"不能作为隔离电器的是（ ）。",[85,87,89,91],{"key":20,"text":86,"correct":21},"连接片；",{"key":23,"text":88,"correct":28},"半导体电器；",{"key":25,"text":90,"correct":21},"不需要拆除导线的特殊端子；",{"key":27,"text":92,"correct":21},"熔断器。",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":23,"analysis":29},1031975,"不能用作通断电流的操作电器是（ ）。",[97,99,101,102],{"key":20,"text":98,"correct":21},"隔离开关；",{"key":23,"text":100,"correct":28},"熔断器",{"key":25,"text":88,"correct":21},{"key":27,"text":103,"correct":21},"10A及以下的插头与插座。",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":20,"analysis":29},1031978,"电力配电箱进线处宜装设（ ）。",[108,109,111,113],{"key":20,"text":98,"correct":28},{"key":23,"text":110,"correct":21},"带瞬时过电流脱扣器的断路器；",{"key":25,"text":112,"correct":21},"熔断器；",{"key":27,"text":114,"correct":21},"带短延时过电流脱扣器的断路器。",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":25,"analysis":29},1031980,"在非导电灰尘的一般多尘场所的低压电器的防护等级应为（）. A. IP44； B. IP4X； C IP5X； D. IP67。",[119,120,121,122],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":20,"analysis":29},1031983,"在浴室（非公共）内的2区（即浴盆外至0.6m范围内）的电器防护等级至少应为（ ）。",[127,129,131,133],{"key":20,"text":128,"correct":28},"IPX4；",{"key":23,"text":130,"correct":21},"IP55；",{"key":25,"text":132,"correct":21},"IP66；",{"key":27,"text":134,"correct":21},"IP67。",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":20,"analysis":29},1031986,"在游泳池的1区（即池边缘外至2m内和池上方2. 5m内空间）的电器防护等级至少应为（ ）。 A. IPX4; B. IP44； C IP55; D. IP67。",[139,140,141,142],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":25,"analysis":29},1031989,"安装在户外露天场所的起动器箱，其防护等级至少应为（）。",[147,149,151,152],{"key":20,"text":148,"correct":21},"IPX4;",{"key":23,"text":150,"correct":21},"IP54；",{"key":25,"text":130,"correct":28},{"key":27,"text":134,"correct":21},{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":25,"analysis":29},1031991,"安装在室内中等腐蚀场所的按钮的防腐类型应为（ ）。 A. IP5X； B. IP65； C. F1 级防腐型；D。 WF1 级防腐型。",[157,158,159,160],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":27,"analysis":29},1031994,"普通低压电器能适用的海拔为（）及以下.",[165,167,169,171],{"key":20,"text":166,"correct":21},"1000m；",{"key":23,"text":168,"correct":21},"1500m；",{"key":25,"text":170,"correct":21},"1800m;",{"key":27,"text":172,"correct":28},"2000m.",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":25,"analysis":29},1031997,"用断路器作短路保护时，短路电流不应小于该断路器瞬时或短延时过电流脱扣器整 定电流的（ ）倍。",[177,179,181,183],{"key":20,"text":178,"correct":21},"1.1,",{"key":23,"text":180,"correct":21},"1.2；",{"key":25,"text":182,"correct":28},"1.3,",{"key":27,"text":184,"correct":21},"1.5.",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":25,"analysis":29},1031999,"突然断电比过负荷造成的损失更大的线路，过负荷保护设置要求是（ ）。",[189,191,193,195],{"key":20,"text":190,"correct":21},"不应装设过负荷保护；",{"key":23,"text":192,"correct":21},"设置过负荷保护应有延时动作；",{"key":25,"text":194,"correct":28},"设置过负荷保护不切断电路，只作用于信号；",{"key":27,"text":196,"correct":21},"设置过负荷保护延时切断电路，同时发出信号。",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":23,"analysis":29},1032002,"TN系统配电线路的接地故障保护的动作特性应符合式（ ）要求。",[201,202,203,204],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":25,"analysis":29},1032004,"TN系统配电线路或仅供固定式电气设备的末端线路，接地故障保护切断故障回路 的时间不宜大于（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":21},"0.4s;",{"key":23,"text":212,"correct":21},"1.5s;",{"key":25,"text":214,"correct":28},"5s；",{"key":27,"text":216,"correct":21},"15s。",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":20,"analysis":29},1032007,"TN系统供给手握式或移动式电气设备的末端线路或插座回路，接地故障保护切断 故障回路的时间不应大于（ ）。",[221,222,223,225],{"key":20,"text":210,"correct":28},{"key":23,"text":212,"correct":21},{"key":25,"text":224,"correct":21},"5s;",{"key":27,"text":216,"correct":21},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":25,"analysis":29},1032010,"A. 4; B. 5； C 6； D. 7.",[230,231,232,233],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":27,"analysis":29},1032013,"TN系统的插座回路采用熔断器作接地故障保护，熔体额定电流（I?)为40~63A, 故障电流（Id)不应小于In的（ ）倍。",[238,240,242,244],{"key":20,"text":239,"correct":21},"7；",{"key":23,"text":241,"correct":21},"8;",{"key":25,"text":243,"correct":21},"9;",{"key":27,"text":245,"correct":28},"10。",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":248,"answer":25,"analysis":29},1032016,[249,250,251,252],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":20,"analysis":29},1032018,"低压配电线路保护用断路器的额定短路分断能力不应小于其安装处的（ ）。",[257,259,261,263],{"key":20,"text":258,"correct":28},"短路电流周期分量有效值；",{"key":23,"text":260,"correct":21},"短路电流峰值；",{"key":25,"text":262,"correct":21},"最大接地故障电流的1.3倍；",{"key":27,"text":264,"correct":21},"短路电流周期分量有效值的1.3倍。",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":20,"analysis":29},1032020,"保护配电线路的熔断器，其分析能力不应小于其安装处的（）.",[269,271,272,274],{"key":20,"text":270,"correct":28},"短路电流交流分量有效值；",{"key":23,"text":260,"correct":21},{"key":25,"text":273,"correct":21},"短路电流交流分量有效值的1. 3倍;",{"key":27,"text":275,"correct":21},"短路电流峰值的1. 3倍。",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":20,"analysis":29},1032023,"配电线路保护用熔断器，其熔体额定电流不应小于线路计算电流的（ ）倍。",[280,281,282,284],{"key":20,"text":35,"correct":28},{"key":23,"text":178,"correct":21},{"key":25,"text":283,"correct":21},"1. 2,",{"key":27,"text":285,"correct":21},"1. 3。",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":20,"analysis":29},1032026,"配电线路保护用断路器，其长延时过电流脱扣器整定电流不应小于线路计箅电流的 ()倍。",[290,291,293,294],{"key":20,"text":57,"correct":28},{"key":23,"text":292,"correct":21},"1.1;",{"key":25,"text":180,"correct":21},{"key":27,"text":295,"correct":21},"1.3。",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":25,"analysis":29},1032029,"用熔断器作配电线路过负荷保护时，熔体额定电流（≥16A者）不应大于线路导体 载流量的（）。",[300,302,304,306],{"key":20,"text":301,"correct":21},"80%；",{"key":23,"text":303,"correct":21},"90%；",{"key":25,"text":305,"correct":28},"100%；",{"key":27,"text":307,"correct":21},"110%。",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":25,"analysis":29},1032031,"用断路器作配电线路过负荷保护时，长延时过电流脱扣器额定电流不应大于线路导 体载流量的（ ）。",[312,313,314,315],{"key":20,"text":301,"correct":21},{"key":23,"text":303,"correct":21},{"key":25,"text":305,"correct":28},{"key":27,"text":307,"correct":21},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":318,"answer":27,"analysis":29},1032033,[319,320,321,322],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":28},{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":23,"analysis":29},1032036,"用熔断器作配电线路保护时，按选择性要求，上下级熔体额定电流之比不应小 于（ ）。",[327,328,330,332],{"key":20,"text":39,"correct":21},{"key":23,"text":329,"correct":28},"1.6;",{"key":25,"text":331,"correct":21},"2.0;",{"key":27,"text":333,"correct":21},"2.5。",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":25,"analysis":29},1032039,"低压配电干线采用选择型断路器作保护，其短延时过电流脱扣器整定电流至少应大 于下级断路器的瞬时过电流脱扣器整定电流的（ ）倍。",[338,340,341,343],{"key":20,"text":339,"correct":21},"0.8;",{"key":23,"text":57,"correct":21},{"key":25,"text":342,"correct":28},"1.2~1.3;",{"key":27,"text":344,"correct":21},"1.5~1.6。",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":347,"answer":27,"analysis":29},1032042,[348,350,352,354],{"key":20,"text":349,"correct":21},"5~6",{"key":23,"text":351,"correct":21},"7~8;",{"key":25,"text":353,"correct":21},"9~10;",{"key":27,"text":355,"correct":28},"12~15,",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":23,"analysis":29},1032045,"IT系统的低压配电线路，当发生第一次接地故障时，应采用的电器是（ ）。",[360,362,364,365],{"key":20,"text":361,"correct":21},"漏电电流保护器；",{"key":23,"text":363,"correct":28},"绝缘监视器；",{"key":25,"text":110,"correct":21},{"key":27,"text":92,"correct":21},{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":25,"analysis":29},1032048,"低压隔离开关在正常运行中，能够分断的线路电流不应大于其额定电流的（ ）。",[370,372,374,376],{"key":20,"text":371,"correct":21},"20%；",{"key":23,"text":373,"correct":21},"50%;",{"key":25,"text":375,"correct":28},"100%;",{"key":27,"text":377,"correct":21},"120%。",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":27,"analysis":29},1032050,"选择屋外裸导体使用的最高环境温度应符合（ ）.",[382,384,386,388],{"key":20,"text":383,"correct":21},"极端最高温度；",{"key":23,"text":385,"correct":21},"年最高温度平均值；",{"key":25,"text":387,"correct":21},"最热月平均温度；",{"key":27,"text":389,"correct":28},"最热月平均最高温度（最热月的日最高温度平均值）。",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":27,"analysis":29},1032053,"选择屋外配电装置导体时所用的最大风速应取（ ）。",[394,396,398,400],{"key":20,"text":395,"correct":21},"50年一遇离地高10m处最大风速；",{"key":23,"text":397,"correct":21},"30年一遇离地高10m处最大风速；",{"key":25,"text":399,"correct":21},"百年一遇离地高10m处lOmin的平均最大风速；",{"key":27,"text":401,"correct":28},"30年一遇离地高10m处lOmin的平均最大风速。",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":23,"analysis":29},1032055,"普通导体正常最髙工作温度不应大于（ )。",[406,408,410,412],{"key":20,"text":407,"correct":21},"60℃;",{"key":23,"text":409,"correct":28},"70℃;",{"key":25,"text":411,"correct":21},"75℃；",{"key":27,"text":413,"correct":21},"80℃。",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":23,"analysis":29},1032058,"验算导体短路热稳定时，裸导体最高允许温度，对硬铝可取（）。",[418,420,422,424],{"key":20,"text":419,"correct":21},"175℃；",{"key":23,"text":421,"correct":28},"200℃；",{"key":25,"text":423,"correct":21},"250℃；",{"key":27,"text":425,"correct":21},"300℃。",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":27,"analysis":29},1032061,"验算导体短路动稳定时，铜导体最大允许力应为（ ）。",[430,432,434,436],{"key":20,"text":431,"correct":21},"70MPa；",{"key":23,"text":433,"correct":21},"90MPa；",{"key":25,"text":435,"correct":21},"120MPa,",{"key":27,"text":437,"correct":28},"140MPa.",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":23,"analysis":29},1032064,"低压铝芯绝缘导线在室外固定敷设，当绝缘子跨度为2~6m时，其最小截面应 为（）。",[442,444,446,448],{"key":20,"text":443,"correct":21},"2. 5 mm2 ；",{"key":23,"text":445,"correct":28},"4 mm2 ；",{"key":25,"text":447,"correct":21},"6mm2 ；",{"key":27,"text":449,"correct":21},"10mm2",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":23,"analysis":29},1032066,"设计所选用的导体，其长期允许电流（）。",[454,456,458,460],{"key":20,"text":455,"correct":21},"应计及故障时转移过来的负荷",{"key":23,"text":457,"correct":28},"不得小于该回路的最大持续工作电流。",{"key":25,"text":459,"correct":21},"1.3倍于正常工作电流；",{"key":27,"text":461,"correct":21},"2倍于正常工作电流。",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":27,"analysis":29},1032069,"验箅导体动热稳定用的短路电流，应为（ ）。",[466,468,470,472],{"key":20,"text":467,"correct":21},"对称短路电流；",{"key":23,"text":469,"correct":21},"单相接地短路电流；",{"key":25,"text":471,"correct":21},"两相接地短路电流；",{"key":27,"text":473,"correct":28},"单相、两相接地短路及三相短路中最严重的短路电流。",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":20,"analysis":29},1032072,"验算导体短路热效应的计箅时间，一般宜采用（ ）。",[478,480,482,484],{"key":20,"text":479,"correct":28},"主保护动作时间加相应的断路器全分闸时间；",{"key":23,"text":481,"correct":21},"后备保护动作时间加相应的断路器全分闸时间；",{"key":25,"text":483,"correct":21},"主保护动作时间加相应的断路器固有分闸时间；",{"key":27,"text":485,"correct":21},"后备保护动作时间加相应的断路器固有分闸时间。",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":25,"analysis":29},1032075,"导体采用多导体结构时，其长期允许载流量为（ ）。",[490,492,494,496],{"key":20,"text":491,"correct":21},"各分导体载流量的代数和；",{"key":23,"text":493,"correct":21},"各分导体载流量的加权和；",{"key":25,"text":495,"correct":28},"应计及邻近效应和热屏蔽对载流量的影响；",{"key":27,"text":497,"correct":21},"应计及集肤效应和热屏蔽对载流量的影响。",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":27,"analysis":29},1032078,"低压配电系统导体截面选择，下列说法中不正确的是（ ）。",[502,504,506,508],{"key":20,"text":503,"correct":21},"线路电压损失应满足用电设备正常工作和启动时端电压的要求；",{"key":23,"text":505,"correct":21},"按敷设方式及环境条件确定的导体载流量不应小于计算电流；",{"key":25,"text":507,"correct":21},"导体最小截面应满足机械强度的要求；",{"key":27,"text":509,"correct":28},"软导线满足动稳定和热稳定的要求。",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":27,"analysis":29},1032081,"低压配电系统中绝缘导线和电缆沿不同冷却条件的路径敷设，应按（ ）选择其 截面。",[514,516,518,520],{"key":20,"text":515,"correct":21},"不重要回路按冷却条件最坏段条件选择绝缘导线和电缆的截面；",{"key":23,"text":517,"correct":21},"只对冷却条件最坏段采用大截面的绝缘导线和电缆；",{"key":25,"text":519,"correct":21},"当冷却条件最坏段的长度超过5m时，按该段条件选择绝缘导线和电缆的截面；",{"key":27,"text":521,"correct":28},"按B或C选择绝缘导线和电缆的截面。",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":20,"analysis":29},1032084,"在三相四线制配电系统中，中性线允许载流量不应小于（ ）。",[526,528,530,532],{"key":20,"text":527,"correct":28},"线路中最大不平衡负荷电流，且应计入谐波电流的影响；",{"key":23,"text":529,"correct":21},"最大相电流；",{"key":25,"text":531,"correct":21},"线路中最大不平衡负荷电流；",{"key":27,"text":533,"correct":21},"最大相电流，且应计入谐波电流的影响。",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":23,"analysis":29},1032086,"以气体放电灯为主要负荷的回路中，其中性线截面应（).",[538,540,542,544],{"key":20,"text":539,"correct":21},"按线路中最大不平衡负荷电流计算，且应计入谐波电流的影响；",{"key":23,"text":541,"correct":28},"不小于相线截面；",{"key":25,"text":543,"correct":21},"按最大相电流计算，且计入谐波电流的影响；",{"key":27,"text":545,"correct":21},"为相线截面的1\u002F2。",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":25,"analysis":29},1032089,"在TN—C系统中，下列关于保护（P E)线和中性(N)线说明正确的是（ ）。",[550,552,554,556],{"key":20,"text":551,"correct":21},"整个系统中PE线和N线是分开的；",{"key":23,"text":553,"correct":21},"整个系统中PE线和N线部分分开；",{"key":25,"text":555,"correct":28},"整个系统中PE线和N线是合一的；",{"key":27,"text":557,"correct":21},"PE线和N线中可接入开关设备。",[559,562,565,568,571,574],{"id":15,"name":560,"category":7,"favorite":561},"领导干部任职前廉政法规知识测试题",92,{"id":563,"name":564,"category":7,"favorite":15},595,"建筑结构与设备",{"id":566,"name":567,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":569,"name":570,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":572,"name":573,"category":7,"favorite":8},534,"BIM工程师",{"id":575,"name":573,"category":7,"favorite":8},535]