[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":542},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,11,50,2321,[13,30,42,54,66,78,90,102,114,126,134,146,158,170,178,186,194,206,214,222,230,242,250,262,274,286,298,310,321,333,345,357,365,377,389,401,409,421,433,445,455,465,473,480,492,500,508,516,524,532],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":29},1031821,1,"单选题","11 OkV有载调压变压器，调整范围通常为（）。 A. 15%； B. 20%； C 25%； D. 30%。",[19,22,24,26],{"key":20,"text":20,"correct":21},"A",false,{"key":23,"text":23,"correct":21},"B",{"key":25,"text":25,"correct":21},"C",{"key":27,"text":27,"correct":28},"D",true,"",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":32,"options":33,"answer":25,"analysis":29},1031824,"电容器组的接线方式，下面叙述欠妥的是（ ）。",[34,36,38,40],{"key":20,"text":35,"correct":21},"高压电容器组接线方式宜采用单星形接线直接接地或双星形接线通过电压互感器接地;",{"key":23,"text":37,"correct":21},"B在中性点非直接接地的电网中，星形接线电容器组的中性点不应接地；",{"key":25,"text":39,"correct":28},"高压电容器组的每相或每个桥臂，由多台电容器串并联组合时，有先并联后串联和 先串联后并联两种接线方式，目前多采用先串联后并联的接线方式；",{"key":27,"text":41,"correct":21},"低压电容器或电容器组，可采用三角形接线或中性点不接地的星形接线方式。",{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":23,"analysis":29},1031827,"在分析系统经常发生的各种短路形式时，在llOkV及以下的中性点直接接地系统 中，应取首相开断系数为（ ）倍的额定开断电流。",[46,48,50,52],{"key":20,"text":47,"correct":21},"1.2；",{"key":23,"text":49,"correct":28},"1.3;",{"key":25,"text":51,"correct":21},"1.4;",{"key":27,"text":53,"correct":21},"1.5。",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":25,"analysis":29},1031828,"在正常运行和短路时，llOkV断路器接线端子的水平机械荷载不应大于（ )。",[58,60,62,64],{"key":20,"text":59,"correct":21},"250N；",{"key":23,"text":61,"correct":21},"500N;",{"key":25,"text":63,"correct":28},"750N；",{"key":27,"text":65,"correct":21},"1000N。",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":27,"analysis":29},1031831,"下列高压设备中，一般只在屋外使用的是（ ）。",[70,72,74,76],{"key":20,"text":71,"correct":21},"高压断路器；",{"key":23,"text":73,"correct":21},"高压负荷开关；",{"key":25,"text":75,"correct":21},"高压隔离开关；",{"key":27,"text":77,"correct":28},"跌开式高压熔断器。",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":25,"analysis":29},1031834,"高压隔离开关选择技术条件，下列所列各项中可以不需要考虑的是（ ）。",[82,84,86,88],{"key":20,"text":83,"correct":21},"电流、电压；",{"key":23,"text":85,"correct":21},"动稳定电流、热稳定电流和持续时间；",{"key":25,"text":87,"correct":28},"开断电流、操作循环；",{"key":27,"text":89,"correct":21},"接线端子的机械荷载。",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":27,"analysis":29},1031837,"关于高压熔断器选择原则，叙述不确切的是（ ）。",[94,96,98,100],{"key":20,"text":95,"correct":21},"熔体的额定电流应按高压熔断器的保护特性选择，应满足保护的可靠性、选择性和 灵敏度的要求；",{"key":23,"text":97,"correct":21},"熔体的额定电流选择过大，将延长熔断时间，降低灵敏度和选择性；",{"key":25,"text":99,"correct":21},"熔体的额定电流选择过小，则不能保证保护的可靠性；",{"key":27,"text":101,"correct":28},"熔体的额定电流选择，应在最短的时间内切断故障，以防止熔断时间过长而加剧被 保护电器的损坏。",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":25,"analysis":29},1031840,"保护35kV及以下电力变压器的高压熔断器的熔体，下面选择原则有误的是（）。",[106,108,110,112],{"key":20,"text":107,"correct":21},"电力变压器回路最大工作电流通过熔体时，不应熔断；",{"key":23,"text":109,"correct":21},"电力变压器的励磁涌流通过熔体时，不应熔断；",{"key":25,"text":111,"correct":28},"熔断器熔体，通过任何地点短路时，应该熔断；",{"key":27,"text":113,"correct":21},"电动机自启动引起的冲去电流时不应熔断。",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":25,"analysis":29},1031842,"关于电流互感器的准确度，下列用法不合适的是（ ）。",[118,120,122,124],{"key":20,"text":119,"correct":21},"用于电度计量的电流互感器，准确度不应低于0.5级；",{"key":23,"text":121,"correct":21},"用于500kV电度计量的电流互感器，准确度宜为0.2级；",{"key":25,"text":123,"correct":28},"用于电流电压测量的准确度，不应低于3级；",{"key":27,"text":125,"correct":21},"TP级电流互感器用于继电保护。",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":25,"analysis":29},1031844,"关于电压互感器选择，下列选择有误的是（ ）。",[130,131,132,133],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":27,"analysis":29},1031847,"关于SF6封闭式组合电器的使用环境和条件，叙述有误的是（ ）。",[138,140,142,144],{"key":20,"text":139,"correct":21},"在大城市中心地区的变电所采用；",{"key":23,"text":141,"correct":21},"地下式配电装置；",{"key":25,"text":143,"correct":21},"布置场所特别狭窄的地区；",{"key":27,"text":145,"correct":28},"环境温度低于一40'C的地区，但应附加电热装置。",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":23,"analysis":29},1031850,"在海拔为1000m及以下的一级污秽地区，当采用X—4.5或XP—6型悬式绝缘子 时，35kV耐张绝缘子串片数不宜少于（ ）片。",[150,152,154,156],{"key":20,"text":151,"correct":21},"3;",{"key":23,"text":153,"correct":28},"4；",{"key":25,"text":155,"correct":21},"5；",{"key":27,"text":157,"correct":21},"6。",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":20,"analysis":29},1031853,"在海拔1000m及以下空气清洁无明显污秽的地区，110kV悬垂绝缘子串的片数为 不宜少于（ ）片。",[162,164,166,168],{"key":20,"text":163,"correct":28},"7；",{"key":23,"text":165,"correct":21},"8;",{"key":25,"text":167,"correct":21},"9;",{"key":27,"text":169,"correct":21},"10。",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":23,"analysis":29},1031855,".消弧线圈过补偿的补偿容量的计算公式为（）。",[174,175,176,177],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":27,"analysis":29},1031858,"中性点经消弧线圈接地的电网，在正常情况下，长时间中性点位移电压不应超过额 定相电压的（ ）。 A. 10%, B. 12% C 13%; D. 15%.",[182,183,184,185],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":28},{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":25,"analysis":29},1031860,"安装在YNd接线双绕组或YNynd接线三绕组变压器中性点上的消弧线圈的容量， 不应超过变压器总容量的（），并且不得大于三绕组的任一绕组的容量. A. 40%; B 45%； C 50%； D. 55%。",[190,191,192,193],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":20,"analysis":29},1031863,"对于选择安装于屋外的电器，环境温度宜采用（）。",[198,200,202,204],{"key":20,"text":199,"correct":28},"年最高温度（多年平均值)；",{"key":23,"text":201,"correct":21},"最高月平均温度（多年平均值）；",{"key":25,"text":203,"correct":21},"最热月平均最高溫度（多年平均值)；",{"key":27,"text":205,"correct":21},"多年极端最高溫度;",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":23,"analysis":29},1031866,"在荷载长期作用及短时作用情况下，选择支柱绝缘子的力学安全系数应分别取 ( ). A. 2.0, 1.67； B 2.5, 1.67; C. 4, 2.5; D. 5.3, 3.3。",[210,211,212,213],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":23,"analysis":29},1031869,"对高压断路器，进行电晕校验的电压等于（ ）。",[218,219,220,221],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":29},1031875,"以下高压设备需要校验短路热稳定的有（）。 A.负荷开关； B电压互感器； C熔断器； D.支柱绝缘子.",[226,227,228,229],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":23,"analysis":29},1031878,"对于电气设备动、热稳定的校验，以下说法不正确的是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":21},"开关类设备必须校猃热稳定和动稳定；",{"key":23,"text":237,"correct":28},"互感器类设备必须校验热稳定和动稳定；",{"key":25,"text":239,"correct":21},"绝缘子不需校验热稳定；",{"key":27,"text":241,"correct":21},"消弧线圈不需校验热稳定和动稳定。",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":27,"analysis":29},1031881,"A. 4s； B. 3s； C 2s； D. ls。",[246,247,248,249],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":28},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":25,"analysis":29},1031883,"装设在变压器中性点的消弧线圈，其补偿方式应为（）",[254,256,258,260],{"key":20,"text":255,"correct":21},"补偿容量应与系统中总的电容量相等；",{"key":23,"text":257,"correct":21},"欠补偿；",{"key":25,"text":259,"correct":28},"C过补偿；",{"key":27,"text":261,"correct":21},"只要补偿系数合适，欠补偿和过补偿都可以。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":25,"analysis":29},1031886,"选择户外高压断路器时必须校验的环境条件是（）。",[266,268,270,272],{"key":20,"text":267,"correct":21},"环境温度、相对湿度、污秽、地震烈度；",{"key":23,"text":269,"correct":21},"环境温度、相对湿度、日温差、地震烈度；",{"key":25,"text":271,"correct":28},"环境温度、最大风速、污秽、地震烈度；",{"key":27,"text":273,"correct":21},"日温差、相对湿度、最大风速、污秽。",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":29},1031889,"断路器的额定关合电流满足（）。",[278,280,282,284],{"key":20,"text":279,"correct":21},"不小于短路电流有效值即可；",{"key":23,"text":281,"correct":21},"不大于短路电流有效值即可；",{"key":25,"text":283,"correct":28},"不小于短路电流冲击值即可；",{"key":27,"text":285,"correct":21},"不大于短路电流冲击值即可。",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":25,"analysis":29},1031891,"llOkV的耐张绝缘子串应预留的零值绝缘子片数为（ ）片。",[290,292,294,296],{"key":20,"text":291,"correct":21},"0;",{"key":23,"text":293,"correct":21},"1；",{"key":25,"text":295,"correct":28},"2；",{"key":27,"text":297,"correct":21},"3",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":23,"analysis":29},1031893,"在校验35kV及以上水平安装的支柱绝缘子的机械强度时，不需计及的项目是 ( ).",[302,304,306,308],{"key":20,"text":303,"correct":21},"绝缘子自重；",{"key":23,"text":305,"correct":28},"风速；",{"key":25,"text":307,"correct":21},"母线重量；",{"key":27,"text":309,"correct":21},"短路电动力。",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":27,"analysis":29},1031896,"隔离开关采用软导线引下连接时，其接线端机械荷载不需计及（）。",[314,316,318,320],{"key":20,"text":315,"correct":21},"引下线的张力；",{"key":23,"text":317,"correct":21},"风力；",{"key":25,"text":319,"correct":21},"冰雪;",{"key":27,"text":309,"correct":28},{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":20,"analysis":29},1031898,"正常运行条件下，GIS外壳上的感应电压不应超过（ ）。",[325,327,329,331],{"key":20,"text":326,"correct":28},"24V；",{"key":23,"text":328,"correct":21},"36V；",{"key":25,"text":330,"correct":21},"60V；",{"key":27,"text":332,"correct":21},"100V。",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":20,"analysis":29},1031901,"SFs全封闭组合电器内，各元件应分成若干气隔。气隔中气体系统的压力，除 ()外，宜采用相同气压。",[337,339,341,343],{"key":20,"text":338,"correct":28},"断路器；",{"key":23,"text":340,"correct":21},"隔离开关；",{"key":25,"text":342,"correct":21},"电流互感器；",{"key":27,"text":344,"correct":21},"避雷器。",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":23,"analysis":29},1031904,"可以兼作并联电容器组的泄能设备的是（）。",[349,351,353,355],{"key":20,"text":350,"correct":21},"电容式电压互感器；",{"key":23,"text":352,"correct":28},"电磁式电压互感器；",{"key":25,"text":354,"correct":21},"瓷绝缘结构电流互感器；",{"key":27,"text":356,"correct":21},"树脂浇注绝缘结构电流互感器。",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":25,"analysis":29},1031907,"当串联电抗器的电抗率为5%时，10kV并联电容器组的额定相电压应选择 ( ).",[361,362,363,364],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":23,"analysis":29},1031910,"地震烈度为8度时，电器需承受的地震力地面水平加速度值和地面垂直加速度值 应分别为（ ）。",[369,371,373,375],{"key":20,"text":370,"correct":21},"0.15g, 0. lg；",{"key":23,"text":372,"correct":28},"0. 2g, O.lg;",{"key":25,"text":374,"correct":21},"0. 2g, 0.15g；",{"key":27,"text":376,"correct":21},"0. 4g, 0. 2g。",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":25,"analysis":29},1031912,"断路器的额定峰值耐受电流是说明断路器（）。",[381,383,385,387],{"key":20,"text":382,"correct":21},"开断短路电流的能力；",{"key":23,"text":384,"correct":21},"承受短路电流热效应的能力；",{"key":25,"text":386,"correct":28},"承受短路电流电动力作用的能力；",{"key":27,"text":388,"correct":21},"关合短路不至于发生触头熔焊的能力.",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":27,"analysis":29},1031914,"1台35kV、2000kV",[393,395,397,399],{"key":20,"text":394,"correct":21},"35士2X2.5%\u002F0.4kV的配电变压器，其低压侧中性点电流 互感器的一次额定电流一般取（ ).",{"key":23,"text":396,"correct":21},"4000A ； B 3000A ；",{"key":25,"text":398,"correct":21},"2000A ；",{"key":27,"text":400,"correct":28},"1000",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":25,"analysis":29},1031917,"隔离开关开、合小电流的额定值通常不大于（）。 A. 0.5A； B 1A; C. 2A； D. 4",[405,406,407,408],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":25,"analysis":29},1031919,"35kV及以下通用型负荷开关应能开断（ ）容量的配电变压器的空载电流。",[413,415,417,419],{"key":20,"text":414,"correct":21},"800kVA；",{"key":23,"text":416,"correct":21},"lOOOkVA；",{"key":25,"text":418,"correct":28},"1250kVA；",{"key":27,"text":420,"correct":21},"600kV",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":27,"analysis":29},1031921,"35kV及以下通用型负荷开关能开断（ ）的电缆电容电流。",[425,427,429,431],{"key":20,"text":426,"correct":21},"不小于5A;",{"key":23,"text":428,"correct":21},"小于8A;",{"key":25,"text":430,"correct":21},"等于9A;",{"key":27,"text":432,"correct":28},"不大于10",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":20,"analysis":29},1031924,"根据GB 1984-2000《交流高压断路器》规定，llOkV断路器应能切断架空线路的 空载电流为（ ）时，不会发生重击穿。",[437,439,441,443],{"key":20,"text":438,"correct":28},"31.5A；",{"key":23,"text":440,"correct":21},"32.5A；",{"key":25,"text":442,"correct":21},"33A；",{"key":27,"text":444,"correct":21},"35",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":25,"analysis":29},1031926,"居住小区变电站中单台变压器（低压为0.4kV)的容量不宜大于（ ）。",[449,451,452,453],{"key":20,"text":450,"correct":21},"2500kVA；",{"key":23,"text":414,"correct":21},{"key":25,"text":418,"correct":28},{"key":27,"text":454,"correct":21},"630kV",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":457,"answer":20,"analysis":29},1031929,[458,460,461,463],{"key":20,"text":459,"correct":28},"1.0；",{"key":23,"text":49,"correct":21},{"key":25,"text":462,"correct":21},"1.5;",{"key":27,"text":464,"correct":21},"2.0。",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":27,"analysis":29},1031931,"A. 100%; B. 80%; C 60%; D. 50%。",[469,470,471,472],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":28},{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":475,"answer":27,"analysis":29},1031934,[476,477,478,479],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":28},{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":25,"analysis":29},1031937,"采用IT系统的配电线路发生第一次接地故障时，应（ ）。",[484,486,488,490],{"key":20,"text":485,"correct":21},"尽快切断故障回路；",{"key":23,"text":487,"correct":21},"延时切断故障回路；",{"key":25,"text":489,"correct":28},"不切断故障回路，只发出报警；",{"key":27,"text":491,"correct":21},"切断故障回路，并发出报警。",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":20,"analysis":29},1031940,"IT系统的外露可导电部分为共同接地时，发生第二次接地故障时，切断故障回路 应符合（）系统的接地故障保护要求。 A. TN； B. TT； C. IT； D TN和TT。",[496,497,498,499],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":23,"analysis":29},1031943,"IT系统的外露可导电部分为单独（或成组）接地，发生第二次接地故障时，切断 故障回路应符合（）系统接地故障保护要求。 A. TN； B. TT； C IT； D.TN和TT。",[504,505,506,507],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":25,"analysis":29},1031945,"IT系统的配电线路不配出中性线，发生第二次接地故障时，切断故障回路应符合 ( )要求。",[512,513,514,515],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":28},{"key":27,"text":27,"correct":21},{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":23,"analysis":29},1031948,"IT系统的配电线路配出中性线，发生第二次接地故障时，切断故障回路应符合 ( )要求。",[520,521,522,523],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":28},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":20,"analysis":29},1031951,"供笼型电动机（直接起动）的末端回路，用aM型熔断器保护，其熔体额定电流不 应小于电动机额定电流的（ ）倍。 A. 1.05~1.10; B. 1.5~2.3; C 2.5~3.5; D. 3.5~4.5。",[528,529,530,531],{"key":20,"text":20,"correct":28},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":27,"text":27,"correct":21},{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":29},1031953,"供轻载直接起动的笼型电动机的末端回路，用断路器保护，其长延时过电流脱扣器 整定电流不应小于电动机额定电流的（ ）倍。",[536,537,539,540],{"key":20,"text":459,"correct":28},{"key":23,"text":538,"correct":21},"1.1;",{"key":25,"text":49,"correct":21},{"key":27,"text":541,"correct":21},"1.6。",[543,546,549,552,555,558],{"id":15,"name":544,"category":7,"favorite":545},"领导干部任职前廉政法规知识测试题",92,{"id":547,"name":548,"category":7,"favorite":15},595,"建筑结构与设备",{"id":550,"name":551,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":553,"name":554,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":556,"name":557,"category":7,"favorite":8},534,"BIM工程师",{"id":559,"name":557,"category":7,"favorite":8},535]