[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-755-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":580},{"id":5,"name":6,"category":7,"favorite":8},755,"电气工程师供配电专业","建筑工程",0,10,50,2321,[13,30,42,54,66,78,90,102,110,122,134,146,154,166,178,190,202,214,226,238,250,260,272,282,292,304,316,326,338,347,355,367,379,390,402,414,426,438,450,462,474,486,497,509,521,529,541,553,561,572],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":29},1031684,1,"单选题","选择悬式绝缘子时不需考虑（ )。 A.标称电压； B.机械荷载； C?动稳定； D.绝缘水平。",[19,22,24,27],{"key":20,"text":20,"correct":21},"A",false,{"key":23,"text":23,"correct":21},"B",{"key":25,"text":25,"correct":26},"C",true,{"key":28,"text":28,"correct":21},"D","",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":32,"options":33,"answer":20,"analysis":29},1031687,"旁路回路的持续工作电流为（ ）。",[34,36,38,40],{"key":20,"text":35,"correct":26},"需旁路的回路最大额定电流；",{"key":23,"text":37,"correct":21},"需旁路的主变压器回路额定电流；",{"key":25,"text":39,"correct":21},"需旁路的电源回路额定电流；",{"key":28,"text":41,"correct":21},"需旁路的出线回路最大负荷电流;",{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":23,"analysis":29},1031690,"—台断路器资料显示其端子允许荷载为1000N,安全系数为3. 5,那么这台断路器 端子所能承受的在正常运行和短路时的最大作用力为（ ）。",[46,48,50,52],{"key":20,"text":47,"correct":21},"3500N；",{"key":23,"text":49,"correct":26},"1000N；",{"key":25,"text":51,"correct":21},"285N；",{"key":28,"text":53,"correct":21},"1500N",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":23,"analysis":29},1031692,"校验电器短路热稳定所用的计箅时间为（）。",[58,60,62,64],{"key":20,"text":59,"correct":21},"继电保护装置主保护动作时间；",{"key":23,"text":61,"correct":26},"继电保护装置后备保护动作时间加断路器全分闸时间；",{"key":25,"text":63,"correct":21},"继电保护装置主保护动作时间加断路器全分闸时间；",{"key":28,"text":65,"correct":21},"断路器全分闸时间。",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":28,"analysis":29},1031695,"关于电器的绝缘水平，下列说法中错误的是（ ）。",[70,72,74,76],{"key":20,"text":71,"correct":21},"根据电网中出现的各种过电压水平确定；",{"key":23,"text":73,"correct":21},"根据电网中保护设备的保护水平来确定；",{"key":25,"text":75,"correct":21},"C通过绝缘配合计算选用适当的过电压保护设备；",{"key":28,"text":77,"correct":26},"不得低于国家规定的标准数值。",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":23,"analysis":29},1031697,"选择电器时所用的最大风速为（ ）。",[82,84,86,88],{"key":20,"text":83,"correct":21},"离地20m高，30年一遇的lOmin平均最大风速；",{"key":23,"text":85,"correct":26},"离地10m高，30年一遇的lOmin平均最大风速；",{"key":25,"text":87,"correct":21},"离地20m高，30年一遇的30min平均最大风速；",{"key":28,"text":89,"correct":21},"离地10m高，30年一遇的30min平均最大风速。",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":25,"analysis":29},1031700,"隔离开关的破冰厚度一般为（ ）。",[94,96,98,100],{"key":20,"text":95,"correct":21},"5mm；",{"key":23,"text":97,"correct":21},"8mm；",{"key":25,"text":99,"correct":26},"10mm;",{"key":28,"text":101,"correct":21},"15mm。",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":20,"analysis":29},1031703,"若Ⅲ级污秽区爬电比距为2.5cm\u002FkV，则变电设备爬电距离应不小于（ ）。",[106,107,108,109],{"key":20,"text":20,"correct":26},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":21},{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":25,"analysis":29},1031706,"根据有关规程规定，地震基本烈度为（）度及以下地区的电器可不采取防震措施。",[114,116,118,120],{"key":20,"text":115,"correct":21},"9;",{"key":23,"text":117,"correct":21},"8;",{"key":25,"text":119,"correct":26},"7；",{"key":28,"text":121,"correct":21},"6。",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":28,"analysis":29},1031709,"下列关于频率大于10Hz的无线电干扰主要来源的说法中不正确的是（ ）。",[126,128,130,132],{"key":20,"text":127,"correct":21},"电器的电流突变；",{"key":23,"text":129,"correct":21},"电器的电压突变；",{"key":25,"text":131,"correct":21},"C电晕放电；",{"key":28,"text":133,"correct":26},"电器内部绝缘的局部放电。",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":20,"analysis":29},1031712,"下列关于变压器选择的说法中不正确的是（ ）。",[138,140,142,144],{"key":20,"text":139,"correct":26},"装有两台及以上主变压器的变电所，当断开一台时，其余主变压器容量应能保证供 应全所负荷；",{"key":23,"text":141,"correct":21},"B多层或高层主体建筑内变电所，宜选用不燃或难燃型变压器；",{"key":25,"text":143,"correct":21},"单台单相负荷较大时，宜设单相变压器；",{"key":28,"text":145,"correct":21},"选择变压器中联结组标号时，配电側同級电压相位角要一致。",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":25,"analysis":29},1031715,"在llOkV及以下电压等级的中性点非直接接地系统中，选择断路器时应取首相开 断系数为（ ）倍额定开断电流。 A. 1.3; B 1.4； C. 1.5； D. 1.6.",[150,151,152,153],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":26},{"key":28,"text":28,"correct":21},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":23,"analysis":29},1031718,"单柱垂直开启式隔离开关在分闸状态下，动静触头间的最小电气距离不应小于配电 装置的最小安全净距（ ）值。",[158,160,162,164],{"key":20,"text":159,"correct":21},"A;",{"key":23,"text":161,"correct":26},"B；",{"key":25,"text":163,"correct":21},"C,",{"key":28,"text":165,"correct":21},"D。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":23,"analysis":29},1031720,"高压负荷开关不可以用于（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":21},"切断负荷电流；",{"key":23,"text":173,"correct":26},"切断短路电流；",{"key":25,"text":175,"correct":21},"关合负荷电流；",{"key":28,"text":177,"correct":21},"带有热脱扣器的负荷开关具有过载保护性能。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":29},1031723,"在llOkV系统中，为避免因铁磁谐振使电压互感器爆炸，应优先选用（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":21},"干式电压互感器；",{"key":23,"text":185,"correct":21},"SFs气体绝缘电压互感器；",{"key":25,"text":187,"correct":21},"油浸式电压互感器；",{"key":28,"text":189,"correct":26},"电容式电压互感器。",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":28,"analysis":29},1031726,"中压开关柜分类若按主设备与柜体配合方式可分为（）。",[194,196,198,200],{"key":20,"text":195,"correct":21},"间隔型，箱型；",{"key":23,"text":197,"correct":21},"单母线，双母线；",{"key":25,"text":199,"correct":21},"户内，户外；",{"key":28,"text":201,"correct":26},"固定式，移开式;",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":23,"analysis":29},1031728,"以下不是预装箱式变电所常见分类方法的是（）。",[206,208,210,212],{"key":20,"text":207,"correct":21},"安装方式；",{"key":23,"text":209,"correct":26},"绝缘介质；",{"key":25,"text":211,"correct":21},"C封闭程度；",{"key":28,"text":213,"correct":21},"高压主接线;",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":29},1031731,"成套设备不需考虑（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":21},"适当部位装伸缩接头；",{"key":23,"text":221,"correct":21},"断路器隔离开关、接地开关间设联锁装置；",{"key":25,"text":223,"correct":21},"C防止外壳破坏的保护措施；",{"key":28,"text":225,"correct":26},"设备增容互换。",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":29},1031734,"当电流互感器用于测量时，其一次额定电流应尽量选得比回路中正常工作电流大 ( )左右。",[230,232,234,236],{"key":20,"text":231,"correct":26},"1\u002F3;",{"key":23,"text":233,"correct":21},"1\u002F2；",{"key":25,"text":235,"correct":21},"1\u002F4;",{"key":28,"text":237,"correct":21},"1\u002F5。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":25,"analysis":29},1031737,"装在电网变压器中性点的消弧线圈应采用过补偿方式，防止运行方式改变时，电容 电流减少，使消弧线圈处于谐振点运行。在正常情况下，脱谐度一般不大于（）",[242,244,246,248],{"key":20,"text":243,"correct":21},"15%；",{"key":23,"text":245,"correct":21},"8%；",{"key":25,"text":247,"correct":26},"10%；",{"key":28,"text":249,"correct":21},"7%。",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":23,"analysis":29},1031739,"变压器中性点接氧化锌避雷器时，则变压器中性点绝缘的工频试验电压乘以冲击系 数后与氧化锌避雷器的操作冲击电流下的残压之间应有（）裕度。",[254,255,256,258],{"key":20,"text":247,"correct":21},{"key":23,"text":243,"correct":26},{"key":25,"text":257,"correct":21},"20%；",{"key":28,"text":259,"correct":21},"12.5%。",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":20,"analysis":29},1031742,"高压电压互感器校验的项目包括（ ）.",[264,266,268,270],{"key":20,"text":265,"correct":26},"颏定电压；",{"key":23,"text":267,"correct":21},"额定电流；",{"key":25,"text":269,"correct":21},"额定开断电流；",{"key":28,"text":271,"correct":21},"短路电流动稳定、热稳定。",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":28,"analysis":29},1031744,"高压熔断器不用校验的项目是（〕",[276,278,279,280],{"key":20,"text":277,"correct":21},"额定电压；",{"key":23,"text":267,"correct":21},{"key":25,"text":269,"correct":21},{"key":28,"text":281,"correct":26},"短路电流动稳定。",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":20,"analysis":29},1031747,"高压支持绝缘子校验的项目是（ ）。",[286,287,288,290],{"key":20,"text":277,"correct":26},{"key":23,"text":267,"correct":21},{"key":25,"text":289,"correct":21},"额定开断电流;",{"key":28,"text":291,"correct":21},"短路电流热稳定。",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":29},1031750,"当实际环境温度在髙于+40℃小于+60℃时，环境温度每增高l℃,普通高压电 器额定电流应减少（ ）。",[296,298,300,302],{"key":20,"text":297,"correct":21},"1.0%；",{"key":23,"text":299,"correct":21},"1.5%;",{"key":25,"text":301,"correct":26},"1.8%；",{"key":28,"text":303,"correct":21},"2.0%；",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":23,"analysis":29},1031753,"在海拔超过（ ）的地区，对35kV及以下的髙压电器可选用高原型产品或暂时采 用外绝缘提高一级的产品。",[308,310,312,314],{"key":20,"text":309,"correct":21},"1500m；",{"key":23,"text":311,"correct":26},"2000m；",{"key":25,"text":313,"correct":21},"3000m；",{"key":28,"text":315,"correct":21},"4000m。",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":20,"analysis":29},1031756,"架空高压线路，可不验箅（ ）。",[320,322,323,324],{"key":20,"text":321,"correct":26},"动、热稳定；",{"key":23,"text":277,"correct":21},{"key":25,"text":267,"correct":21},{"key":28,"text":325,"correct":21},"环境温度。",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":25,"analysis":29},1031758,"用熔断器保护的（ ），可不验箅动、热稳定。",[330,332,334,336],{"key":20,"text":331,"correct":21},"电缆；",{"key":23,"text":333,"correct":21},"限流电抗器；",{"key":25,"text":335,"correct":26},"电压互感器；",{"key":28,"text":337,"correct":21},"母线。",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":23,"analysis":29},1031761,"用熔断器保护的（ ）可不验箅热稳定，但动稳定仍应验箅。",[342,343,345,346],{"key":20,"text":335,"correct":21},{"key":23,"text":344,"correct":26},"高压电器；",{"key":25,"text":333,"correct":21},{"key":28,"text":337,"correct":21},{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":23,"analysis":29},1031764,"—般高压电流互感器可以使用在（ ）、相对湿度为85%环境中。 A.+10℃； B.+20℃； C+30℃; D. +40℃。",[351,352,353,354],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":26},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":21},{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":28,"analysis":29},1031767,"在长江以南和沿海地区，当相对湿度超过一般使用标准时，应选用髙压电器型号后 带（）字样的产品。",[359,361,363,365],{"key":20,"text":360,"correct":21},"\"TA\",",{"key":23,"text":362,"correct":21},"\"TC\",",{"key":25,"text":364,"correct":21},"\"TE\",",{"key":28,"text":366,"correct":26},"\"TH\".",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":28,"analysis":29},1031770,"一般高压电器（除电流互感器〕可以使用在+20℃相对湿度为（ ）环境中。",[371,373,375,377],{"key":20,"text":372,"correct":21},"70%,",{"key":23,"text":374,"correct":21},"80%；",{"key":25,"text":376,"correct":21},"85%;",{"key":28,"text":378,"correct":26},"90%。",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":20,"analysis":29},1031773,"当实际环境温度低于+40℃时，环境温度每降低1℃,普通高压电器额定电流应增 加（ ）。但总的增加不得超过额定电流的20%。",[383,385,387,388],{"key":20,"text":384,"correct":26},"0.5%;",{"key":23,"text":386,"correct":21},"1.5%；",{"key":25,"text":301,"correct":21},{"key":28,"text":389,"correct":21},"2.0%。",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":29},1031775,"高压电器在进行试验或计算时，日照强度取O.lW\u002Fcm2,风速取（ ）。",[394,396,398,400],{"key":20,"text":395,"correct":26},"0. 5m\u002Fs；",{"key":23,"text":397,"correct":21},"1. Om\u002Fs；",{"key":25,"text":399,"correct":21},"1. 5m\u002Fs;",{"key":28,"text":401,"correct":21},"2. Om\u002Fs。",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":25,"analysis":29},1031777,"为维护、测试和检修设备安全需断开电源时，应设置（ ）。",[406,408,410,412],{"key":20,"text":407,"correct":21},"空气断路器；",{"key":23,"text":409,"correct":21},"继电器；",{"key":25,"text":411,"correct":26},"隔离电器；",{"key":28,"text":413,"correct":21},"接触器.",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":28,"analysis":29},1031780,"普通髙压电器一般可在环境最低温度为（）时正常运行。",[418,420,422,424],{"key":20,"text":419,"correct":21},"-10℃；",{"key":23,"text":421,"correct":21},"-15℃；",{"key":25,"text":423,"correct":21},"-20℃;",{"key":28,"text":425,"correct":26},"—30℃,",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":23,"analysis":29},1031783,"普通高压电器型号后带\"TA”字样，代表高压电器可以应用在长期处于低湿度年 最髙温度超过（ ）的干热地区。",[430,432,434,436],{"key":20,"text":431,"correct":21},"35℃；",{"key":23,"text":433,"correct":26},"40℃；",{"key":25,"text":435,"correct":21},"45℃,",{"key":28,"text":437,"correct":21},"50℃",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":25,"analysis":29},1031786,"为了减少噪声对工作场所和附近居民的影响，在距髙压电器（ ）处连续性噪声水 平不应大于85dB。",[442,444,446,448],{"key":20,"text":443,"correct":21},"1.0m;",{"key":23,"text":445,"correct":21},"1. 5m；",{"key":25,"text":447,"correct":26},"2. Om；",{"key":28,"text":449,"correct":21},"2. 5m。",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":25,"analysis":29},1031789,"为了减少噪声对工作场所和附近居民的影响，在屋内距高压电器2m处非连续性噪 声水平不应大于（ ）。",[454,456,458,460],{"key":20,"text":455,"correct":21},"70dB；",{"key":23,"text":457,"correct":21},"80dB;",{"key":25,"text":459,"correct":26},"90dB；",{"key":28,"text":461,"correct":21},"lOOdB。",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":25,"analysis":29},1031792,"标称电压为35kV的系统中，电气设备最高工作电压为（ ）。",[466,468,470,472],{"key":20,"text":467,"correct":21},"35kV；",{"key":23,"text":469,"correct":21},"38. 5kV；",{"key":25,"text":471,"correct":26},"40. 5kV；",{"key":28,"text":473,"correct":21},"42kV。",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":28,"analysis":29},1031794,"标称电压为llOkV的系统中，电气设备最高工作电压为（ ）。",[478,480,482,484],{"key":20,"text":479,"correct":21},"llOkV；",{"key":23,"text":481,"correct":21},"115kV；",{"key":25,"text":483,"correct":21},"121kV；",{"key":28,"text":485,"correct":26},"126kV。",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":29,"options":488,"answer":20,"analysis":29},1031796,[489,491,493,495],{"key":20,"text":490,"correct":26},"电抗器额定电流；",{"key":23,"text":492,"correct":21},"1.05倍电抗器额定电流；",{"key":25,"text":494,"correct":21},"1.1倍电抗器额定电流；",{"key":28,"text":496,"correct":21},"1.2倍电抗器额定电流。",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":25,"analysis":29},1031799,"验箅电器动稳定、热稳定以及电器开断电流所用的短路电流，应按工程的规划容量计算，电力系统的远景发展规划容量宜按（）年考虑。",[501,503,505,507],{"key":20,"text":502,"correct":21},"3~5;",{"key":23,"text":504,"correct":21},"4~8;",{"key":25,"text":506,"correct":26},"5~10;",{"key":28,"text":508,"correct":21},"8~15；",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":25,"analysis":29},1031802,"对带电抗器的6~10kV出线回路，按电抗器前短路计算的设备为（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":21},"6~10kV电抗器前的断路器；",{"key":23,"text":516,"correct":21},"6~10kV电抗器前的母线隔离开关;",{"key":25,"text":518,"correct":26},"6~10kV母线隔离开关前的穿墙套管；",{"key":28,"text":520,"correct":21},"6~10kV电抗器前的支柱绝缘子。",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":23,"analysis":29},1031805,"电压为llOkV的电器和金具，在（ ）倍最高工作相电压下，晴天夜晚不应 出现 可见电晕。 A. 1.05； B. 1.1, C 1.2； D. 1,3。",[525,526,527,528],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":26},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":21},{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":25,"analysis":29},1031808,"69.下面所列绝缘子的安全系数有误的是（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":21},"套管、支持绝缘子：荷载长期作用时为2.5,荷载短期作用时为1.67;",{"key":23,"text":536,"correct":21},"悬式绝缘子：荷载长期作用时为4，荷载短期作用时为2.5;",{"key":25,"text":538,"correct":26},"套管、支持绝缘子的金具：荷载长期作用时为2.5,荷载短期作用时为1.67;",{"key":28,"text":540,"correct":21},"悬式绝缘子的金具：荷载长期作用时为4,荷载短期作用时为2.5。",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":28,"analysis":29},1031811,"—般高压电器可在风速不大于（）的环境下使用。",[545,547,549,551],{"key":20,"text":546,"correct":21},"20m\u002Fs；",{"key":23,"text":548,"correct":21},"25m\u002Fs;",{"key":25,"text":550,"correct":21},"30m\u002Fs；",{"key":28,"text":552,"correct":26},"35m\u002Fs。",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":25,"analysis":29},1031812,"在轻盐碱和炉烟污秽地区，离海岸盐场3~10km地区，则该地区污秽等级为（）级。 A. 0； B. I ； CⅡ； D. Ⅲ",[557,558,559,560],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":25,"text":25,"correct":26},{"key":28,"text":28,"correct":21},{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":20,"analysis":29},1031815,"海拔超过（ ）的地区称为高原地区。",[565,567,569,570],{"key":20,"text":566,"correct":26},"1000m；",{"key":23,"text":568,"correct":21},"1200m；",{"key":25,"text":309,"correct":21},{"key":28,"text":571,"correct":21},"2000m。",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":23,"analysis":29},1031818,"无励磁调压变压器，调整范围通常在（ ）以内。 A. ±2.5%; B. ±5%; C ±7%; D. ±10%",[576,577,578,579],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":26},{"key":25,"text":25,"correct":21},{"key":28,"text":28,"correct":21},[581,584,587,590,593,596],{"id":15,"name":582,"category":7,"favorite":583},"领导干部任职前廉政法规知识测试题",92,{"id":585,"name":586,"category":7,"favorite":15},595,"建筑结构与设备",{"id":588,"name":589,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":591,"name":592,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":594,"name":595,"category":7,"favorite":8},534,"BIM工程师",{"id":597,"name":595,"category":7,"favorite":8},535]