[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":605},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,8,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,198,206,218,230,242,254,266,278,290,302,314,326,338,350,361,373,385,397,409,421,433,445,457,469,479,491,501,510,522,533,545,557,569,581,593],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1022100,1,"单选题","为消除由于温度变化引起的危险应力，对滑动支持式铝管母线一般每隔（）m左右安装一个伸缩接头。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","30~40；",true,{"key":24,"text":25,"correct":26},"B","20~30;",false,{"key":28,"text":29,"correct":26},"C","40~50;",{"key":31,"text":32,"correct":26},"D","50~60。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1022101,"为消除由于温度变化引起的危险应力，对滚动支持式铝管母线一般每隔（）m左右安装一个伸缩接头。",[38,40,42,44],{"key":20,"text":39,"correct":26},"20;",{"key":24,"text":41,"correct":22},"根据计算确定；",{"key":28,"text":43,"correct":26},"30~40;",{"key":31,"text":45,"correct":26},"20~30,",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1022102,"对于功率为200MW及以上的发电机引出线、厂用电源和电压互感器分支线，为避免相间短路和减少导体对邻近钢构的感应发热，宜采用（）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"矩形母线；",{"key":24,"text":53,"correct":26},"槽形母线；",{"key":28,"text":55,"correct":26},"管形母线；",{"key":31,"text":57,"correct":22},"全连式离相封闭母线。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1022103,"对于与封闭母线配套的隔离开关和电流互感器的允许温升应（ ）封闭母线的允许温升。",[62,64,66,68],{"key":20,"text":63,"correct":22},"等于；",{"key":24,"text":65,"correct":26},"大于；",{"key":28,"text":67,"correct":26},"小于；",{"key":31,"text":69,"correct":26},"大于等于。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},1022104,"封闭母线的导体采用三个绝缘子支持时，可不进行的计算是（）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"母线应力计算；",{"key":24,"text":77,"correct":26},"固定结构应力计算；",{"key":28,"text":79,"correct":22},"绝缘子抗弯计算；",{"key":31,"text":81,"correct":26},"不确定。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1022105,"封闭母线和电器的连接处，导体和外壳应设置()的伸缩接头。",[86,88,90,92],{"key":20,"text":87,"correct":26},"可拆却；",{"key":24,"text":89,"correct":22},"不可拆卸；",{"key":28,"text":91,"correct":26},"焊接；",{"key":31,"text":93,"correct":26},"螺栓连接。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1022106,"当封闭母线的直线段长度在（）m左右及有可能发生不同沉陷的场所，导体和外壳宜设置()伸缩接头。",[98,100,102,104],{"key":20,"text":99,"correct":26},"30,可拆卸的；",{"key":24,"text":101,"correct":22},"20，不可拆卸的；",{"key":28,"text":103,"correct":26},"20,可拆却的；",{"key":31,"text":105,"correct":26},"30，不可拆却的。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1022107,"控制电缆应采用（）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"铝芯；",{"key":24,"text":113,"correct":22},"铜芯；",{"key":28,"text":115,"correct":26},"钢芯;",{"key":31,"text":117,"correct":26},"光纤。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},1022108,"如图7-1所标参数，1OkV配电装置室内最高环境温度为+30℃，三相母线水平布置，导体平放。 当周围环境温度为30℃时，矩形母线综合校正系数为（）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"1.0；",{"key":24,"text":125,"correct":26},"0.88;",{"key":28,"text":127,"correct":22},"O.94；",{"key":31,"text":129,"correct":26},"0.81。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},1022109,"如图7-1所标参数，1OkV配电装置室内最高环境温度为+30℃，三相母线水平布置，导体平放。 选用3 (125X1Omm)矩形母线，综合校正后载流量为（）.",[134,136,138,140],{"key":20,"text":135,"correct":26},"3725A；",{"key":24,"text":137,"correct":22},"3501.5A；",{"key":28,"text":139,"correct":26},"3278A;",{"key":31,"text":141,"correct":26},"3017.5A。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},1022110,"如图7-1所标参数，1OkV配电装置室内最高环境温度为+30℃，三相母线水平布置，导体平放。 机械共振允许的片间衬垫最大跨距为（）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"61cm;",{"key":24,"text":149,"correct":26},"54cm；",{"key":28,"text":151,"correct":26},"48cm；",{"key":31,"text":153,"correct":26},"65cm。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},1022111,"如图7-1所标参数，1OkV配电装置室内最高环境温度为+30℃，三相母线水平布置，导体平放。 母线自翻率为（）（绝缘子间跨距为180cm时)。",[158,160,162,164],{"key":20,"text":159,"correct":26},"150.5Hz；",{"key":24,"text":161,"correct":26},"100Hz;",{"key":28,"text":163,"correct":22},"193.6Hz；",{"key":31,"text":165,"correct":26},"205Hz。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":20,"analysis":33},1022112,"发电厂高压厂用变压器型号和参数如下：SFFPL:31500\u002F15、31500\u002F16000—16000kV A、15.75±2X2.5\u002F6.3~6.3kV,6kV母线安装为竖放，环境温度按40℃考虑。 6kV侧持续工作电流为（）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"1539.7A；",{"key":24,"text":173,"correct":26},"1541.6A；",{"key":28,"text":175,"correct":26},"1466.4A；",{"key":31,"text":177,"correct":26},"1616.7A。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},1022113,"发电厂高压厂用变压器型号和参数如下：SFFPL:31500\u002F15、31500\u002F16000—16000kV A、15.75±2X2.5\u002F6.3~6.3kV,6kV母线安装为竖放，环境温度按40℃考虑。 选用2 XLMY—100X10母线，在40℃环境温度及母线竖放条件下其综合校正后的载流量为（）。",[182,184,186,188],{"key":20,"text":183,"correct":26},"2460.48A；",{"key":24,"text":185,"correct":26},"2628.24A；",{"key":28,"text":187,"correct":22},"2264.76A；",{"key":31,"text":189,"correct":26},"2069.04A。",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":33},1022114,"某发电厂髙压厂用变压器型号和参数如下：SFFPL—31500\u002F15、31500\u002F16000-16000kVA、15.75±2X2.5\u002F6.3—6.3kV;短路时通过6.3kV侧母线的冲击电流为ich=55.8kA,6kV母线选用2XLMY—100X10母线，母线安装为竖放，环境温度按40℃考虑。 满足机械强度要求时母线最大跨距为（）。",[194,195,196,197],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":24,"analysis":33},1022115,"某发电厂髙压厂用变压器型号和参数如下：SFFPL—31500\u002F15、31500\u002F16000-16000kVA、15.75±2X2.5\u002F6.3—6.3kV;短路时通过6.3kV侧母线的冲击电流为ich=55.8kA,6kV母线选用2XLMY—100X10母线，母线安装为竖放，环境温度按40℃考虑。 满足机械强度要求时衬垫临界跨距为（）。",[202,203,204,205],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":26},{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":24,"analysis":33},1022116,"某发电厂髙压厂用变压器型号和参数如下：SFFPL—31500\u002F15、31500\u002F16000-16000kV A、15.75±2X2.5\u002F6.3—6.3kV;短路时通过6.3kV侧母线的冲击电流为ich=55.8kA,6kV母线选用2XLMY—100X10母线，母线安装为竖放，环境温度按40℃考虑。 选用2 XLMY — 100X10母线，在40℃环境温度及母线自振频率（ )(绝缘子间跨距为100cm).",[210,212,214,216],{"key":20,"text":211,"correct":26},"173.6Hz;",{"key":24,"text":213,"correct":22},"180.5Hz;",{"key":28,"text":215,"correct":26},"135.5Hz；",{"key":31,"text":217,"correct":26},"200Hz。",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":28,"analysis":33},1022117,"选择并校验1OOMW发电机一变压器组的连接母线.已知：发电机额定电压为10.5kV,额定电流为6468A,最大负荷利用小时数为5200h,发电机连接母线上短路电流为I\"=35.4kA,\u002F00=22.8KPa。地区最热月平均温度为+35℃,发电机连接母线三相水平布置。 宜选用的母线型式为（ ）.",[222,224,226,228],{"key":20,"text":223,"correct":26},"矩形；",{"key":24,"text":225,"correct":26},"管形；",{"key":28,"text":227,"correct":22},"槽形；",{"key":31,"text":229,"correct":26},"软导线。",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":20,"analysis":33},1022118,"选择并校验1OOMW发电机一变压器组的连接母线.已知：发电机额定电压为10.5kV,额定电流为6468A,最大负荷利用小时数为5200h,发电机连接母线上短路电流为I\"=35.4kA,\u002F00=22.8KPa。地区最热月平均温度为+35℃,发电机连接母线三相水平布置。 选用铝母线，其经济电流密度为（）.",[234,236,238,240],{"key":20,"text":235,"correct":22},"0.48A\u002Fmm2；",{"key":24,"text":237,"correct":26},"0.9A\u002Fmm2；",{"key":28,"text":239,"correct":26},"O.8A\u002Fmm2;",{"key":31,"text":241,"correct":26},"1.OA\u002Fmm2。",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":24,"analysis":33},1022119,"选择并校验1OOMW发电机一变压器组的连接母线.已知：发电机额定电压为10.5kV,额定电流为6468A,最大负荷利用小时数为5200h,发电机连接母线上短路电流为I\"=35.4kA,\u002F00=22.8KPa。地区最热月平均温度为+35℃,发电机连接母线三相水平布置。 满足经济电流密度要求母线截面为()。",[246,248,250,252],{"key":20,"text":247,"correct":26},"8510mm2；",{"key":24,"text":249,"correct":22},"8936mm2；",{"key":28,"text":251,"correct":26},"8489mm2;",{"key":31,"text":253,"correct":26},"7546mm2。",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":20,"analysis":33},1022120,"选择并校验1OOMW发电机一变压器组的连接母线.已知：发电机额定电压为10.5kV,额定电流为6468A,最大负荷利用小时数为5200h,发电机连接母线上短路电流为I\"=35.4kA,\u002F00=22.8KPa。地区最热月平均温度为+35℃,发电机连接母线三相水平布置。 应进行的校验不包括（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":22},"载流量的环境温度校验；",{"key":24,"text":261,"correct":26},"短路热稳定校验；",{"key":28,"text":263,"correct":26},"短路动稳定校验；",{"key":31,"text":265,"correct":26},"母线自振效率校检。",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":24,"analysis":33},1022121,"某发电厂机组容量为600MW，高压厂用变压器为低压分裂绕组变压器，高压厂用电压为6.6kV，6.6kV断路器采用真空断路器，6.6kV母线短路电流结果为I\"B=20.92k A，I\"D=16.78k A，计算时间为t=0.15s。6.6kV电缆采用交联聚乙烯绝缘电缆。 短路热效应为（）。",[270,272,274,276],{"key":20,"text":271,"correct":26},"2690.8cm;",{"key":24,"text":273,"correct":22},"2707. 5cm;",{"key":28,"text":275,"correct":26},"2660. 6cm;",{"key":31,"text":277,"correct":26},"2750.3cm。",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":20,"analysis":33},1022122,"某发电厂机组容量为600MW，高压厂用变压器为低压分裂绕组变压器，高压厂用电压为6.6kV，6.6kV断路器采用真空断路器，6.6kV母线短路电流结果为I\"B=20.92k A，I\"D=16.78k A，计算时间为t=0.15s。6.6kV电缆采用交联聚乙烯绝缘电缆。 满足短路热稳定要求的（铝芯电缆）最小截面为（）。",[282,284,286,288],{"key":20,"text":283,"correct":22},"171.6mm2;",{"key":24,"text":285,"correct":26},"167mm2；",{"key":28,"text":287,"correct":26},"176.6mm2;",{"key":31,"text":289,"correct":26},"182.3mm2。",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":28,"analysis":33},1022123,"某发电厂机组容量为600MW，高压厂用变压器为低压分裂绕组变压器，高压厂用电压为6.6kV，6.6kV断路器采用真空断路器，6.6kV母线短路电流结果为I\"B=20.92k A，I\"D=16.78k A，计算时间为t=0.15s。6.6kV电缆采用交联聚乙烯绝缘电缆。 选择交联聚乙炼绝缘电缆缆芯最小截面为（）。",[294,296,298,300],{"key":20,"text":295,"correct":26},"120mm2;",{"key":24,"text":297,"correct":26},"150mm2；",{"key":28,"text":299,"correct":22},"185mm2；",{"key":31,"text":301,"correct":26},"90mm2。",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":28,"analysis":33},1022124,"某工程低压厂用变压器为 SCB—1250\u002F10，1250kVA,6.3±2X2.5\u002F0.4kV，Ud=6%,Dynl.变压器和0.4kV低压成套开关柜通过硬母线直接相连.配电室内环境温度为+40℃,母线水平安装。 低压变压器回路持续工作电流为（），",[306,308,310,312],{"key":20,"text":307,"correct":26},"1804.3A；",{"key":24,"text":309,"correct":26},"3125A;",{"key":28,"text":311,"correct":22},"1894.4A；",{"key":31,"text":313,"correct":26},"721.7A。",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":24,"analysis":33},1022125,"某工程低压厂用变压器为 SCB—1250\u002F10，1250kVA,6.3±2X2.5\u002F0.4kV，Ud=6%,Dynl.变压器和0.4kV低压成套开关柜通过硬母线直接相连.配电室内环境温度为+40℃,母线水平安装。 选择矩形铝母线的规格为（）。",[318,320,322,324],{"key":20,"text":319,"correct":26},"LMY—100X10；",{"key":24,"text":321,"correct":22},"2(LMY—100X10)；",{"key":28,"text":323,"correct":26},"2(LMY—80X10)；",{"key":31,"text":325,"correct":26},"LMY-125X10.",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":20,"analysis":33},1022126,"某工程高压厂用变压器为低压分裂绕组变压器，高压厂用电压为6.3kV，6.3kV断路器采用真空断路器，6.3kV工作段短路电流计算结果为I\"B=27.8k A，I\"D=16.23kA,选铜芯交联电缆，在空气中敷设，电缆载流量综合修正系数为0.65。6.3kV工作段接有一台功率为500kW电动机， 该电动机回路持续工作电流为（）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"60.14A,",{"key":24,"text":333,"correct":26},"48.1A；",{"key":28,"text":335,"correct":26},"104.2A；",{"key":31,"text":337,"correct":26},"83.3A。",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":28,"analysis":33},1022127,"某工程高压厂用变压器为低压分裂绕组变压器，高压厂用电压为6.3kV，6.3kV断路器采用真空断路器，6.3kV工作段短路电流计算结果为I\"B=27.8k A，I\"D=16.23kA,选铜芯交联电缆，在空气中敷设，电缆载流量综合修正系数为0.65。6.3kV工作段接有一台功率为500kW电动机， 按该电动机回路持续工作电流选择电缆截面（铜芯）为（）。",[342,344,346,348],{"key":20,"text":343,"correct":26},"50mm2；",{"key":24,"text":345,"correct":26},"25mm2；",{"key":28,"text":347,"correct":22},"35mm2；",{"key":31,"text":349,"correct":26},"70mm2。",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":31,"analysis":33},1022128,"某工程高压厂用变压器为低压分裂绕组变压器，高压厂用电压为6.3kV，6.3kV断路器采用真空断路器，6.3kV工作段短路电流计算结果为I\"B=27.8k A，I\"D=16.23kA,选铜芯交联电缆，在空气中敷设，电缆载流量综合修正系数为0.65。6.3kV工作段接有一台功率为500kW电动机， 按满足6. 3kV系统短路热稳定要求选择电缆截面（铜芯）为（）。",[354,356,358,359],{"key":20,"text":355,"correct":26},"95mm2；",{"key":24,"text":357,"correct":26},"70mm2；",{"key":28,"text":343,"correct":26},{"key":31,"text":360,"correct":22},"120mm2。",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":20,"analysis":33},1022129,"某工程，髙压厂用电压为6.3kV，6.3kV电缆最小热稳定截面120mm2(铜芯），电缆沿电缆隧道、电缆沟和梯级桥架敷设且多根单层并列，环境温度为+35℃,缆芯最髙工作温度为+80℃,6.3kV工作段接有一台功率为2500kW电动机。 该电动机回路持续工作电流为（）。",[365,367,369,371],{"key":20,"text":366,"correct":22},"300.7A；",{"key":24,"text":368,"correct":26},"240.6A；",{"key":28,"text":370,"correct":26},"520.9A；",{"key":31,"text":372,"correct":26},"1804.2A。",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},1022130,"某工程，髙压厂用电压为6.3kV，6.3kV电缆最小热稳定截面120mm2(铜芯），电缆沿电缆隧道、电缆沟和梯级桥架敷设且多根单层并列，环境温度为+35℃,缆芯最髙工作温度为+80℃,6.3kV工作段接有一台功率为2500kW电动机。 电缆载流量的综合修正系数为（）。",[377,379,381,383],{"key":20,"text":378,"correct":26},"0.779；",{"key":24,"text":380,"correct":22},"0.8；",{"key":28,"text":382,"correct":26},"0.692,",{"key":31,"text":384,"correct":26},"0.815。",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":20,"analysis":33},1022131,"选择并校验1OOMW发电机一变压器组的连接母线.已知：发电机额定电压为10.5kV,额定电流为6468A,最大负荷利用小时数为5200h,发电机连接母线上短路电流为I\"=35.4kA,\u002F00=22.8KPa。地区最热月平均温度为+35℃,发电机连接母线三相水平布置。 应进行的校验不包括（ ）。 选用标准槽型铝母线200X90X12 (hXbXt), S=8080mm2,按环境温度+35℃ 的综合校正后的载流量为（）》",[389,391,393,395],{"key":20,"text":390,"correct":22},"7744A；",{"key":24,"text":392,"correct":26},"8272A；",{"key":28,"text":394,"correct":26},"7128A；",{"key":31,"text":396,"correct":26},"8800A。",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":28,"analysis":33},1022132,"在110kV及220kV系统中，开断空载架空线路的过电压不超过（），开断电缆线路可能超过（）。",[401,403,405,407],{"key":20,"text":402,"correct":26},"2.Op.u.、2.Op.u.；",{"key":24,"text":404,"correct":26},"2.5p.u.、2.5p.u.；",{"key":28,"text":406,"correct":22},"3.Op.u.、3.Op.u.；",{"key":31,"text":408,"correct":26},"3.5p.u.、3.5p.u.。",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":31,"analysis":33},1022133,"在66kV及以下系统中，系统发生单相接地故障时，开断空载线路的过电压可能超过（）。",[413,415,417,419],{"key":20,"text":414,"correct":26},"2.5p.u.；",{"key":24,"text":416,"correct":26},"3.Op.u.；",{"key":28,"text":418,"correct":26},"3.5p.u.；",{"key":31,"text":420,"correct":22},"4.Op.u.。",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":28,"analysis":33},1022134,"对范围II的线路，若系统送受端联系薄弱，将产生线路非对称故障分闸或振荡解列过电压。如预测该过电压趄过2.2p.u.（330kV）、2.Op.u.（500kV），宜采取的限制措施是（ ）。",[425,427,429,431],{"key":20,"text":426,"correct":26},"线路受端安装金属氧化物避雷器；",{"key":24,"text":428,"correct":26},"线路送端安装金属氧化物避雷器；",{"key":28,"text":430,"correct":22},"线路送、受端同时安装金属氣化物避雷器；",{"key":31,"text":432,"correct":26},"线路中间安装金属氧化物避雷器。",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":28,"analysis":33},1022135,"隔离开关操作空载母线时，由于重击穿将会产生幅值可能超过（）、频率为数百千赫至兆赫的高频振荡过电压。",[437,439,441,443],{"key":20,"text":438,"correct":26},"1.8p.u.；",{"key":24,"text":440,"correct":26},"1.9p.u.；",{"key":28,"text":442,"correct":22},"2.Op.u.；",{"key":31,"text":444,"correct":26},"2.1p.u.。",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":28,"analysis":33},1022136,"3~66kV系统开断并联电容补偿装置，如断路器发生单相重击穿时，电容器高压端对地过电压可能超过（），开断时如果发生两相重击穿，电容器极间过电压可能超过（）电容器额定电压。",[449,451,453,455],{"key":20,"text":450,"correct":26},"3.Op.u.、2.2√2;",{"key":24,"text":452,"correct":26},"3.5p.u.、2.4√2；",{"key":28,"text":454,"correct":22},"4.Op.u.,2.5√2；",{"key":31,"text":456,"correct":26},"4.5p.u.、2.8√2。",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":33},1022137,"开断具有冷轧硅钢片铁心的空载变压器，过电压一般不超过（）；开断具有热轧硅钢片铁心的11OkV和220kV空载变压器，过电压一般不超过（）。",[461,463,465,467],{"key":20,"text":462,"correct":26},"1.8p.u.、2.5p.u.；",{"key":24,"text":464,"correct":22},"2.Op.u.、3.Op.u.；",{"key":28,"text":466,"correct":26},"2.2p.u.、3.5p.u.；",{"key":31,"text":468,"correct":26},"2.5p..u.、4.Op.u.。",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":24,"analysis":33},1022138,"空载变压器和并联电抗补偿装置合闸过电压，一般不超过（）。",[473,474,475,477],{"key":20,"text":438,"correct":26},{"key":24,"text":442,"correct":22},{"key":28,"text":476,"correct":26},"2.2p.u.；",{"key":31,"text":478,"correct":26},"2p.u.。",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":28,"analysis":33},1022139,"采用真空断路器开断启动过程中的高压感应电动机时，截流过电压和三相同时开断过电压可能超过（）；高频重复重击穿过电压可能超过（）。",[483,485,487,489],{"key":20,"text":484,"correct":26},"3.Op.u.、4.Op.u.；",{"key":24,"text":486,"correct":26},"3.5p.u.、4.5p.u.；",{"key":28,"text":488,"correct":22},"4.Op.u.、5.Op.u.；",{"key":31,"text":490,"correct":26},"4.5p.u.、5.5p.u.。",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":20,"analysis":33},1022140,"髙压感应电动机合闸过电压，一般不超过（ ）。",[495,496,497,499],{"key":20,"text":442,"correct":22},{"key":24,"text":476,"correct":26},{"key":28,"text":498,"correct":26},"2.4p.u.；",{"key":31,"text":500,"correct":26},"2.5p.u.。",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":31,"analysis":33},1022141,"采用真空断路器开断空载高压感应电动机，过电压一般不超过（）。",[505,506,508,509],{"key":20,"text":476,"correct":26},{"key":24,"text":507,"correct":26},"2.3p.u.；",{"key":28,"text":498,"correct":26},{"key":31,"text":500,"correct":22},{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":31,"analysis":33},1022142,"66kV及以下系统发生单相间歇性电弧接地故障时，不接地方式下产生的过电压不超过（）；经消弧线圏接地方式过电压不超过（）；电阻接地方式过电压不超过（）。",[514,516,518,520],{"key":20,"text":515,"correct":26},"3.2p.u.、2.9p.u.、2.2p.u.；",{"key":24,"text":517,"correct":26},"3.3p.u.、3.Op.u.、2.3p.u.；",{"key":28,"text":519,"correct":26},"3.4p.u.、3.1p.u.、2.4p.u.；",{"key":31,"text":521,"correct":22},"3.5p.u.、3.2p.u.、2.5p.u.。",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":24,"analysis":33},1022143,"单支避雷针的高度为25m；在计算其保护范围时，其高度影响系数P为（）。",[526,528,529,531],{"key":20,"text":527,"correct":26},"O.9;",{"key":24,"text":123,"correct":22},{"key":28,"text":530,"correct":26},"1.1；",{"key":31,"text":532,"correct":26},"1.2。",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":24,"analysis":33},1022144,"单支避雷针的高度为25m;在地面上的保护半径为（）。",[537,539,541,543],{"key":20,"text":538,"correct":26},"35m；",{"key":24,"text":540,"correct":22},"37.5m；",{"key":28,"text":542,"correct":26},"40m；",{"key":31,"text":544,"correct":26},"42.5m。",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":28,"analysis":33},1022145,"单支避雷针的高度为25m，被保护物高度为15m，在被保护物高度水平面上的保护半径为（）。",[549,551,553,555],{"key":20,"text":550,"correct":26},"7.5m；",{"key":24,"text":552,"correct":26},"8.5m；",{"key":28,"text":554,"correct":22},"10m；",{"key":31,"text":556,"correct":26},"10.5m,",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":24,"analysis":33},1022146,"两支避雷针的髙度同为30m，两针间距离为84m，则两针间保护范围上部边缘最低点的高度为（）。",[561,563,565,567],{"key":20,"text":562,"correct":26},"15m；",{"key":24,"text":564,"correct":22},"18m；",{"key":28,"text":566,"correct":26},"21m,",{"key":31,"text":568,"correct":26},"24m。",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":20,"analysis":33},1022147,"两支等高避雷针的针间距离与针高之比不宜大于（）。",[573,575,577,579],{"key":20,"text":574,"correct":22},"5；",{"key":24,"text":576,"correct":26},"6；",{"key":28,"text":578,"correct":26},"7；",{"key":31,"text":580,"correct":26},"8。",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":28,"analysis":33},1022148,"单根避雷线的高度为15m,则避雷线在8m水平面上毎侧保护范围的宽度为（）。",[585,587,589,591],{"key":20,"text":586,"correct":26},"2.95m；",{"key":24,"text":588,"correct":26},"3.15m；",{"key":28,"text":590,"correct":22},"3.29m；",{"key":31,"text":592,"correct":26},"3.48m。",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":24,"analysis":33},1022149,"单根避雷线的高度为15m，则避雷线在7m水平面上每侧保护范围的宽度为（）。",[597,599,601,603],{"key":20,"text":598,"correct":26},"4.19m；",{"key":24,"text":600,"correct":22},"4.29m；",{"key":28,"text":602,"correct":26},"4.39m；",{"key":31,"text":604,"correct":26},"4.49m。",[606,609,612,615,618,621],{"id":15,"name":607,"category":7,"favorite":608},"领导干部任职前廉政法规知识测试题",92,{"id":610,"name":611,"category":7,"favorite":15},595,"建筑结构与设备",{"id":613,"name":614,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":616,"name":617,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":619,"name":620,"category":7,"favorite":8},534,"BIM工程师",{"id":622,"name":620,"category":7,"favorite":8},535]