[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":603},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,7,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,177,189,197,205,217,229,241,253,265,277,289,298,309,321,333,345,357,369,381,393,405,417,428,440,449,461,473,485,497,508,520,532,544,556,568,580,592],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1022050,1,"单选题","交流系统中电缆的（）耐压水平，应满足系统绝缘配合要求。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1min工頻；",false,{"key":24,"text":25,"correct":26},"B","冲击；",true,{"key":28,"text":29,"correct":22},"C","线电压；",{"key":31,"text":32,"correct":22},"D","相电压。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1022051,"6~1OkV电缆采用黏性油浸纸绝缘电缆时，其电缆线路最高与最低点之闻的高差为()。",[38,40,42,44],{"key":20,"text":39,"correct":22},"25m;",{"key":24,"text":41,"correct":26},"15m；",{"key":28,"text":43,"correct":22},"20m；",{"key":31,"text":45,"correct":22},"30m.",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},1022052,"当自容式充油电缆与六氟化硫全封闭电器直接连接且封闭式终端不具备油与气的严密隔离时，电缆的最低工作油压应()六氟化硫全封闭电器的最高工作气压。",[50,52,54,56],{"key":20,"text":51,"correct":22},"小于；",{"key":24,"text":53,"correct":22},"等于；",{"key":28,"text":55,"correct":26},"大于；",{"key":31,"text":57,"correct":22},"小于等于。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},1022053,"60℃以上高温场所，不宜选用的电缆为（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"耐热聚氯乙烯绝缘电缆；",{"key":24,"text":65,"correct":22},"普通交联聚乙烯绝缘电缆；",{"key":28,"text":67,"correct":22},"乙两橡皮絶缘电缆；",{"key":31,"text":69,"correct":26},"聚氯乙烯绝缘电缆。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1022054,"用于中、髙压回路的交联聚乙烯电缆，应选用属于具备（）特性的绝缘构造型式。",[74,76,78,80],{"key":20,"text":75,"correct":22},"耐高温,",{"key":24,"text":77,"correct":26},"耐水树；",{"key":28,"text":79,"correct":22},"耐腐蚀；",{"key":31,"text":81,"correct":22},"耐潮。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},1022055,"移动式电气设备等需经常弯移或有较高柔软性要求回路的电缆，应选用的外护层为()。",[86,88,90,92],{"key":20,"text":87,"correct":22},"聚氯乙烯；",{"key":24,"text":89,"correct":22},"聚乙烯；",{"key":28,"text":91,"correct":26},"橡皮；",{"key":31,"text":93,"correct":22},"氯磺化聚乙烯。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1022056,"双重化保护的电流、电压以及直流电源和跳闸控制回路等增强可靠性的两套系统，应采用（）的控制电缆。",[98,100,102,104],{"key":20,"text":99,"correct":22},"合用；",{"key":24,"text":101,"correct":26},"各自独立；",{"key":28,"text":103,"correct":22},"同一；",{"key":31,"text":105,"correct":22},"统一。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1022057,"弱电回路的每一对往返导线，宜属于（）控制电缆。",[110,112,114,116],{"key":20,"text":111,"correct":22},"同一根；",{"key":24,"text":113,"correct":26},"不同的；",{"key":28,"text":115,"correct":22},"相同的；",{"key":31,"text":117,"correct":22},"合同，",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1022058,"需降低干扰的控制电缆，可在工作芯外增加（）接地的备用芯。",[122,124,126,128],{"key":20,"text":123,"correct":22},"多个；",{"key":24,"text":125,"correct":26},"—个；",{"key":28,"text":127,"correct":22},"二个；",{"key":31,"text":129,"correct":22},"三个。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},1022059,"1OkV及以下交联聚乙烯绝缘电缆，额定负荷时，缆芯最高允许工作温度为（)℃。",[134,136,138,140],{"key":20,"text":135,"correct":22},"1OO;",{"key":24,"text":137,"correct":22},"80；",{"key":28,"text":139,"correct":26},"90；",{"key":31,"text":141,"correct":22},"110。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1022060,"在户内电缆沟、隧道敷设并无机械通风的情况下，确定电缆持续允许载流量的环境温度为（）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"年平均最高温度;",{"key":24,"text":149,"correct":26},"最热月的日最髙温度平均值加5℃;",{"key":28,"text":151,"correct":22},"年平均最低溫度；",{"key":31,"text":153,"correct":22},"最热月的日最高温度平均值。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},1022061,"交流供电回路由多根电缆并联组成时，宜采用（）截面。",[158,160,162,164],{"key":20,"text":159,"correct":22},"不同；",{"key":24,"text":161,"correct":26},"相同；",{"key":28,"text":163,"correct":22},"已任意组合；",{"key":31,"text":165,"correct":22},"多种。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":20,"analysis":33},1022062,"用于保护接地中性线铜芯最小截面应()10mm2。",[170,172,174,175],{"key":20,"text":171,"correct":26},"不小于；",{"key":24,"text":173,"correct":22},"不大于；",{"key":28,"text":51,"correct":22},{"key":31,"text":176,"correct":22},"等于。",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":24,"analysis":33},1022063,"6kV多芯交联聚乙餘绝缘电缆的允许弯曲半径一般为（）倍电缆外径。",[181,183,185,187],{"key":20,"text":182,"correct":22},"10；",{"key":24,"text":184,"correct":26},"15;",{"key":28,"text":186,"correct":22},"8;",{"key":31,"text":188,"correct":22},"12。",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":28,"analysis":33},1022064,"自容式铅包充油电缆允许弯曲半径一般为（)倍电缆外径。 A.10； B15； C.20； D.14。",[193,194,195,196],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":20,"analysis":33},1022065,"1kV及以下电力电缆可与（）控制和信号电缆配置在同一层支架上。 A.强电； B弱电； C.强电和弱电；D.计算机。",[201,202,203,204],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":28,"analysis":33},1022066,"除交流系统用单芯电缆情况外，电力电缆相互间宜有( )mm空隙。",[209,211,213,215],{"key":20,"text":210,"correct":22},"25；",{"key":24,"text":212,"correct":22},"30；",{"key":28,"text":214,"correct":26},"35；",{"key":31,"text":216,"correct":22},"32。",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":24,"analysis":33},1022067,"某发电厂主变压器容量为750MV A，550-2X2.5\u002F22kV,Ud=14%,Yd0。主变压器高压侧经架空软导线和500kV相连，环境最髙温度为+40℃，海拔髙度为400m。 主变压器髙压侧持续工作电流为（）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"787A；",{"key":24,"text":224,"correct":26},"827A；",{"key":28,"text":226,"correct":22},"866A；",{"key":31,"text":228,"correct":22},"909A。",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":28,"analysis":33},1022068,"某发电厂主变压器容量为750MV A，550-2X2.5\u002F22kV,Ud=14%,Yd0。主变压器高压侧经架空软导线和500kV相连，环境最髙温度为+40℃，海拔髙度为400m。 软导线在该海拔髙度和环境温度下的综合校正系数为().",[233,235,237,239],{"key":20,"text":234,"correct":22},"1.0；",{"key":24,"text":236,"correct":22},"0.89;",{"key":28,"text":238,"correct":26},"0.83;",{"key":31,"text":240,"correct":22},"0.76.",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":28,"analysis":33},1022069,"某发电厂主变压器容量为750MV A，550-2X2.5\u002F22kV,Ud=14%,Yd0。主变压器高压侧经架空软导线和500kV相连，环境最髙温度为+40℃，海拔髙度为400m。 主变压器进线回路导线选择2 (LGKK-600),经校正后的载流量为（）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"2408A；",{"key":24,"text":248,"correct":22},"2143A；",{"key":28,"text":250,"correct":26},"2030A；",{"key":31,"text":252,"correct":22},"1830A。",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":20,"analysis":33},1022070,"某发电厂主变压器容量为 720MV A，500±2X2.5\u002F22kV，Ud=14%，Yd0。500kV母线穿越功率为2500MW，cosΨ=0.9,环境最高温度为+29.7℃，海拔髙度为400m，500kV母线选用2XLGJQT—1400。 500kV主母线持续工作电流为（）。",[257,259,261,263],{"key":20,"text":258,"correct":26},"3208A；",{"key":24,"text":260,"correct":22},"2886.8A；",{"key":28,"text":262,"correct":22},"5555.6A;",{"key":31,"text":264,"correct":22},"5000A。",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":24,"analysis":33},1022071,"某发电厂主变压器容量为 720MV A，500±2X2.5\u002F22kV，Ud=14%，Yd0。500kV母线穿越功率为2500MW，cosΨ=0.9,环境最高温度为+29.7℃，海拔髙度为400m，500kV母线选用2XLGJQT—1400。 按海拔高度和环境温度下的综合校正系数为（ ）（导体最高允许工作温度+80℃,基准环境温度+40℃；条件下）（对母线而言）。",[269,271,273,275],{"key":20,"text":270,"correct":22},"1.0;",{"key":24,"text":272,"correct":26},"0.94；",{"key":28,"text":274,"correct":22},"1.092;",{"key":31,"text":276,"correct":22},"0.89。",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":20,"analysis":33},1022072,"某工程，500kV母线穿越功率为2500MW, 500kV母线短路参数：I\"=27.19kA,I∞=24.22kA,71.24k A，短路热效应Q=95.6kA2s;计算时间：t=0.1\",环境最髙温度为+29.7℃,海拔髙度为400m,500kV母线选用2XLGJQT—1400。 500kV主母线短路热稳定截面为（）（导体最髙允许温度+80℃)。",[281,283,285,287],{"key":20,"text":282,"correct":26},"118mm2；",{"key":24,"text":284,"correct":22},"11Omm2；",{"key":28,"text":286,"correct":22},"1OOmm2；",{"key":31,"text":288,"correct":22},"150mm2。",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":24,"analysis":33},1022073,"某工程，500kV母线穿越功率为2500MW, 500kV母线短路参数：I\"=27.19kA,I∞=24.22kA,71.24k A，短路热效应Q=95.6kA2s;计算时间：t=0.1\",环境最髙温度为+29.7℃,海拔髙度为400m,500kV母线选用2XLGJQT—1400。 校验电晕电压值应（ ）550kV。",[293,294,295,296],{"key":20,"text":51,"correct":22},{"key":24,"text":55,"correct":26},{"key":28,"text":53,"correct":22},{"key":31,"text":297,"correct":22},"不大于。",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":24,"analysis":33},1022074,"如图7-1所标参数，1OkV配电装置室内最高环境温度为+30℃，三相母线水平布置，导体平放。 10.5kV主母线持续工作电流为（）。",[302,304,306,308],{"key":20,"text":303,"correct":22},"3299A；",{"key":24,"text":305,"correct":26},"3464A；",{"key":28,"text":307,"correct":22},"55714.3A；",{"key":31,"text":264,"correct":22},{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":24,"analysis":33},1022075,"选用导体的长期允许电流不得小于该回路的（）。",[313,315,317,319],{"key":20,"text":314,"correct":22},"短路电流有效值；",{"key":24,"text":316,"correct":26},"持续工作电流；",{"key":28,"text":318,"correct":22},"短路全电流；",{"key":31,"text":320,"correct":22},"接地电流。",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":31,"analysis":33},1022076,"导体的动、热稳定可按（）验算。",[325,327,329,331],{"key":20,"text":326,"correct":22},"三相短路电流；",{"key":24,"text":328,"correct":22},"两相短路电流；",{"key":28,"text":330,"correct":22},"单相短路电流；",{"key":31,"text":332,"correct":26},"按上述三项中最大者。",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":28,"analysis":33},1022077,"验算裸导体短路热效应的计算时间，采用（）",[337,339,341,343],{"key":20,"text":338,"correct":22},"主保护动作时间；",{"key":24,"text":340,"correct":22},"主保护动作时间加断路器全分闸时间；",{"key":28,"text":342,"correct":26},"后备保护动作时间加断路器全分闸时间；",{"key":31,"text":344,"correct":22},"后备保护动作时间。",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":28,"analysis":33},1022078,"选择导体时，应按（)条件校核。",[349,351,353,355],{"key":20,"text":350,"correct":22},"温度，湿度；",{"key":24,"text":352,"correct":22},"风速；",{"key":28,"text":354,"correct":26},"环境；",{"key":31,"text":356,"correct":22},"污秽，海拔高度",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":33},1022079,"选择屋外裸导体的环境温度为（）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"多年平均最高温度；",{"key":24,"text":364,"correct":26},"多年最热月平均最高溫度；",{"key":28,"text":366,"correct":22},"年最高溫度；",{"key":31,"text":368,"correct":22},"年最低温度。",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":20,"analysis":33},1022080,"选择屋内裸导体环境温度为（）。",[373,375,377,379],{"key":20,"text":374,"correct":26},"该处通风设计温度或多年最热月平均最高温度5℃",{"key":24,"text":376,"correct":22},"多年平均最髙温度；",{"key":28,"text":378,"correct":22},"多年最热月平均最高温度；",{"key":31,"text":380,"correct":22},"多年平均最低温度。",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":20,"analysis":33},1022081,"导体正常工作温度不应超过()，在计及日照影响时，钢芯铝线及管型导体可按不超过（）。当导体接触面处有镀（搪）锡的可靠覆盖层时，可提高到（）。",[385,387,389,391],{"key":20,"text":386,"correct":26},"+70℃，+80℃,+85℃；",{"key":24,"text":388,"correct":22},"+45℃,+70℃，+80℃；",{"key":28,"text":390,"correct":22},"+70℃，+85℃,+90℃；",{"key":31,"text":392,"correct":22},"+85℃,+90℃，+110℃。",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":20,"analysis":33},1022082,"按回路正常工作电流选择导体截面时，导体的长期允许载流量应按（ ）进行。",[397,399,401,403],{"key":20,"text":398,"correct":26},"所在地区海拔及环境温度；",{"key":24,"text":400,"correct":22},"所在地区海拔及环境湿度；",{"key":28,"text":402,"correct":22},"所在地区污秽及环境湿度；",{"key":31,"text":404,"correct":22},"所在地区污秽及环境淇度。",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":24,"analysis":33},1022083,"导体采用多导体结构时，尚应考虑()对载流量的影响。",[409,411,413,415],{"key":20,"text":410,"correct":22},"排列形式；",{"key":24,"text":412,"correct":26},"邻近效应和热屏蔽；",{"key":28,"text":414,"correct":22},"集肤效应；",{"key":31,"text":416,"correct":22},"热屏蔽。",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":24,"analysis":33},1022084,"在发电厂工程设计中，发电机一主变压器回路导体截面按（）选取。",[421,423,425,426],{"key":20,"text":422,"correct":22},"回路持续工作电流；",{"key":24,"text":424,"correct":26},"经济电流密度；",{"key":28,"text":314,"correct":22},{"key":31,"text":427,"correct":22},"短路全电流。",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":24,"analysis":33},1022085,"按经济电流密度选择导体截面时，如无合适规格导体时，导体面积可按经济电流密度计算截面的相邻（）选取.",[432,434,436,438],{"key":20,"text":433,"correct":22},"上一档；",{"key":24,"text":435,"correct":26},"下一档；",{"key":28,"text":437,"correct":22},"上二档；",{"key":31,"text":439,"correct":22},"下二档。",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":24,"analysis":33},1022086,"钜形导体的搭接长度不应（）导体的宽度。",[444,445,446,447],{"key":20,"text":55,"correct":22},{"key":24,"text":51,"correct":26},{"key":28,"text":53,"correct":22},{"key":31,"text":448,"correct":22},"大于等于。",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":24,"analysis":33},1022087,"在海拔高度不超过1000m的地区，在常用相间距离情况下，220kV导体可不进行电晕校验的最小导体型号及外径为（）mm。",[453,455,457,459],{"key":20,"text":454,"correct":22},"LGJ—70，Φ18;",{"key":24,"text":456,"correct":26},"LGJ-300,Φ30;",{"key":28,"text":458,"correct":22},"2XLGJQ-300,Φ40;",{"key":31,"text":460,"correct":22},"LGJ—185,Φ20",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":24,"analysis":33},1022088,"验算短路热稳定时，导体的最高允许温度，对硬铝或铝锰合金可取（ ）℃；对硬铜可取（）℃。",[465,467,469,471],{"key":20,"text":466,"correct":22},"100，200；",{"key":24,"text":468,"correct":26},"200，300；",{"key":28,"text":470,"correct":22},"300,400,",{"key":31,"text":472,"correct":22},"100,300。",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":24,"analysis":33},1022089,"500kV选用软导线宜选用（）。",[477,479,481,483],{"key":20,"text":478,"correct":22},"单根销芯铝绞线；",{"key":24,"text":480,"correct":26},"双分裂导线；",{"key":28,"text":482,"correct":22},"空心导线；",{"key":31,"text":484,"correct":22},"特轻型铝纹线。",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":28,"analysis":33},1022090,"220kV及以下复导线的间距可取（）mm。",[489,491,493,495],{"key":20,"text":490,"correct":22},"50~100;",{"key":24,"text":492,"correct":22},"200~300；",{"key":28,"text":494,"correct":26},"100~200；",{"key":31,"text":496,"correct":22},"300~400。",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":24,"analysis":33},1022091,"330kV及以上的双分裂导线的分裂间距可取（）mm.",[501,502,504,506],{"key":20,"text":494,"correct":22},{"key":24,"text":503,"correct":26},"200~400;",{"key":28,"text":505,"correct":22},"300~500;",{"key":31,"text":507,"correct":22},"200~300。",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":20,"analysis":33},1022092,"在确定复导线和分裂导线间隔棒的间距时应考虑（）对构架和电器接线埔子的影响，避开（）的临界点。",[512,514,516,518],{"key":20,"text":513,"correct":26},"动态拉力的大小和时间，动态拉力最大值；",{"key":24,"text":515,"correct":22},"静态拉力，静态拉力最大值；",{"key":28,"text":517,"correct":22},"动态拉力最大值，动态拉力最大值；",{"key":31,"text":519,"correct":22},"静态拉力最大值，静态拉力最大值。",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":28,"analysis":33},1022093,"对架空导线，间隔棒的间距可取（）的数值；对设备间的连接导线，间距可取()的数值。",[524,526,528,530],{"key":20,"text":525,"correct":22},"较小，较大；",{"key":24,"text":527,"correct":22},"较大，较大；",{"key":28,"text":529,"correct":26},"较大，较小；",{"key":31,"text":531,"correct":22},"较小，较小。",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},1022094,"220kV及以下回路正常工作电流在()A及以下时，宜选用（）导体。",[536,538,540,542],{"key":20,"text":537,"correct":26},"4000,矩形；",{"key":24,"text":539,"correct":22},"5000,槽形;",{"key":28,"text":541,"correct":22},"5000,矩形；",{"key":31,"text":543,"correct":22},"4000，槽型。",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":24,"analysis":33},1022095,"220kV及以下回路正常工作电淹在（）A时，宜选用（）导体。",[548,550,552,554],{"key":20,"text":549,"correct":22},"4000~8000,矩形；",{"key":24,"text":551,"correct":26},"4000~8000,槽形；",{"key":28,"text":553,"correct":22},"4000~8000,管形；",{"key":31,"text":555,"correct":22},"4000,槽形。",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":24,"analysis":33},1022096,"11OkV及以上高压配电装置，当采用硬导体时，宜选用（）导体。",[560,562,564,566],{"key":20,"text":561,"correct":22},"矩形；",{"key":24,"text":563,"correct":26},"铝合金管形；",{"key":28,"text":565,"correct":22},"槽形；",{"key":31,"text":567,"correct":22},"空气绝缘母线。",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":28,"analysis":33},1022097,"管形导体在无冰无风正常状态下的挠度，一般不大于（）D (D为导体直径)。",[572,574,576,578],{"key":20,"text":573,"correct":22},"0~0.5;",{"key":24,"text":575,"correct":22},"1~1.5;",{"key":28,"text":577,"correct":26},"0.5~1;",{"key":31,"text":579,"correct":22},"1.5~2.0",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":28,"analysis":33},1022098,"为消除220kV及以上电压管形导体的端部效应，可采取的搶施有()。",[584,586,588,590],{"key":20,"text":585,"correct":22},"延长导体端部；",{"key":24,"text":587,"correct":22},"延长导体端部或在端部加装屏蔽电极；",{"key":28,"text":589,"correct":26},"在端部加装屏蔽放电极,",{"key":31,"text":591,"correct":22},"延长导体端部2m左右。",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":28,"analysis":33},1022099,"为消除由于温度变化引起的危险应力，矩形硬铝导体的直线段一般每隔（）m左右安装一个伸缩接头。",[596,597,599,601],{"key":20,"text":184,"correct":22},{"key":24,"text":598,"correct":22},"30;",{"key":28,"text":600,"correct":26},"20；",{"key":31,"text":602,"correct":22},"25。",[604,607,610,613,616,619],{"id":15,"name":605,"category":7,"favorite":606},"领导干部任职前廉政法规知识测试题",92,{"id":608,"name":609,"category":7,"favorite":15},595,"建筑结构与设备",{"id":611,"name":612,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":614,"name":615,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":617,"name":618,"category":7,"favorite":8},534,"BIM工程师",{"id":620,"name":618,"category":7,"favorite":8},535]