[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,6,50,2670,[13,34,46,54,66,78,90,102,114,126,138,150,162,174,186,198,210,222,234,246,258,270,282,294,306,318,330,342,354,365,377,389,401,413,425,437,449,457,469,481,493,505,517,529,541,553,565,577,589,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1022000,1,"单选题","除500kV外，选择屋外配电装置电器时，所用的最大风速，可取离地面高度1Om,且（）年一遇的1Omin平均最大风速。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","10；",false,{"key":24,"text":25,"correct":22},"B","15；",{"key":27,"text":28,"correct":22},"C","20；",{"key":30,"text":31,"correct":32},"D","30,",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":30,"analysis":33},1022001,"—般高压电器可在风速不大于（）的环境下使用。",[38,40,42,44],{"key":20,"text":39,"correct":22},"20m\u002Fs；",{"key":24,"text":41,"correct":22},"25m\u002Fs；",{"key":27,"text":43,"correct":22},"30m\u002Fs；",{"key":30,"text":45,"correct":32},"35m\u002Fs。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},1022002,"一般高压电器可在+20℃、相对湿度为（）的环境中使用。 A.80%； B.85%； C90%； D.95%。",[50,51,52,53],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":22},{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":27,"analysis":33},1022003,"在轻盐碱和炉烟污秽地区，离海岸盐场3~1Okm地区，则该地区污秽等级为（）。",[58,60,62,64],{"key":20,"text":59,"correct":22},"O级；",{"key":24,"text":61,"correct":22},"I级；",{"key":27,"text":63,"correct":32},"II级，",{"key":30,"text":65,"correct":22},"III级。",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":20,"analysis":33},1022004,"海拔超过（）的地区称为髙原地区。",[70,72,74,76],{"key":20,"text":71,"correct":32},"1OOOm；",{"key":24,"text":73,"correct":22},"1200m；",{"key":27,"text":75,"correct":22},"1500m；",{"key":30,"text":77,"correct":22},"2000m,",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":20,"analysis":33},1022005,"关于空冷发电机机端额定电压，下面正确的是（）。",[82,84,86,88],{"key":20,"text":83,"correct":32},"50MW或60MW,6.3kV或10.5kV；",{"key":24,"text":85,"correct":22},"100MW,18.20kV；",{"key":27,"text":87,"correct":22},"125MW,18.20kV；",{"key":30,"text":89,"correct":22},"200MW,20.22kV。",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":30,"analysis":33},1022006,"发电机定子绕组在空载及额定电压、额定转速时线电压波形畸变率应不超过（）。",[94,96,98,100],{"key":20,"text":95,"correct":22},"1%；",{"key":24,"text":97,"correct":22},"2%,",{"key":27,"text":99,"correct":22},"4%；",{"key":30,"text":101,"correct":32},"5%",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":30,"analysis":33},1022007,"发电机在额定功率因数下，电压变化范围及频率变化分别为（）时，能连续输出额定功率。",[106,108,110,112],{"key":20,"text":107,"correct":22},"±1%、±0.5%；",{"key":24,"text":109,"correct":22},"±1.5%、±0.8%；",{"key":27,"text":111,"correct":22},"±2.5%、±1.0%；",{"key":30,"text":113,"correct":32},"±5%、±2.0%,",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":24,"analysis":33},1022008,"当最大机组容量为125MW及以下的发电厂以两种升高电压向用户供电或与电力系统连接时，其主变压器宜采用三绕组变压器，但每个绕组的通过功率应达到该变压器额定容量的（）。",[118,120,122,124],{"key":20,"text":119,"correct":22},"10%以上；",{"key":24,"text":121,"correct":32},"15%以上；",{"key":27,"text":123,"correct":22},"20%以上；",{"key":30,"text":125,"correct":22},"30%以上。",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},1022009,"无励磁调压变压器，调整范围通常在（）以内。",[130,132,134,136],{"key":20,"text":131,"correct":22},"±2.5%",{"key":24,"text":133,"correct":32},"±5%；",{"key":27,"text":135,"correct":22},"±7%；",{"key":30,"text":137,"correct":22},"±10%。",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":33},1022010,"110~500kV有载调压变压器，调整范围通常为（）。",[142,144,146,148],{"key":20,"text":143,"correct":22},"15%；",{"key":24,"text":145,"correct":32},"20%；",{"key":27,"text":147,"correct":22},"25%；",{"key":30,"text":149,"correct":22},"30%。",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":27,"analysis":33},1022011,"电容器组的接线方式，下面叙述欠妥的是（）。",[154,156,158,160],{"key":20,"text":155,"correct":22},"高压电容器组接线方式宜采用单星形接线直接接地或双星形接线通过电压互感器接地；",{"key":24,"text":157,"correct":22},"在中性点非直接接地的电网中，星形接线电容器组的中性点不应接地；",{"key":27,"text":159,"correct":32},"高压电容器組的每相或每个桥臂由多台电容器串并联组合时，有先并联后串联和先串联后并联两种接线方式，目前多采用先串联后并联的接线方式；",{"key":30,"text":161,"correct":22},"低压电容器或电容器组，可釆用三角形接线或中性点不接地的星形接线方式。",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":30,"analysis":33},1022012,"在分析系统经常发生的各种短路形式时，在11OkV及以下的中性点非直接接地系统中，应取首相开断系数为（）倍的额定开断电流。",[166,168,170,172],{"key":20,"text":167,"correct":22},"1.2；",{"key":24,"text":169,"correct":22},"1.3；",{"key":27,"text":171,"correct":22},"1.4；",{"key":30,"text":173,"correct":32},"1.5。",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":20,"analysis":33},1022013,"根据《交流高压断路器》GB 1984—2000,11OkV断路器应能切断架空线路的空载电流为（）时，不会发生重击穿。",[178,180,182,184],{"key":20,"text":179,"correct":32},"31.5A；",{"key":24,"text":181,"correct":22},"32.5A,",{"key":27,"text":183,"correct":22},"33A；",{"key":30,"text":185,"correct":22},"35A。",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":27,"analysis":33},1022014,"在正常运行和短路时，11OkV断路器接线端子的水平机械荷载不应大于（）。",[190,192,194,196],{"key":20,"text":191,"correct":22},"250N；",{"key":24,"text":193,"correct":22},"500N；",{"key":27,"text":195,"correct":32},"750N；",{"key":30,"text":197,"correct":22},"1000N。",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":20,"analysis":33},1022015,"多油断路器重合闸时其开断电流要降低，其降低系数为下面给出的几组数据，有错误的是（）。",[202,204,206,208],{"key":20,"text":203,"correct":32},"1OkA以下是0.85；",{"key":24,"text":205,"correct":22},"11~20kA是0.75；",{"key":27,"text":207,"correct":22},"21~40kA是0.7；",{"key":30,"text":209,"correct":22},"40kA以上是0.65。",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":30,"analysis":33},1022016,"下列高压设备，一般只在屋外使用的是（）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"高压断路器；",{"key":24,"text":217,"correct":22},"高压负荷开关；",{"key":27,"text":219,"correct":22},"高压隔离开关；",{"key":30,"text":221,"correct":32},"跌开式高压熔断器。",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":30,"analysis":33},1022017,"35kV及以下通用型负荷开关能开断（）的电缆电容电流.",[226,228,230,232],{"key":20,"text":227,"correct":22},"不小于5A；",{"key":24,"text":229,"correct":22},"小于8A；",{"key":27,"text":231,"correct":22},"等于9A；",{"key":30,"text":233,"correct":32},"不大于10A。",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":27,"analysis":33},1022018,"35kV及以下通用型负荷开关应能开断（）容量的配电变压器的空载电流。",[238,240,242,244],{"key":20,"text":239,"correct":22},"800kVA；",{"key":24,"text":241,"correct":22},"1OOOkVA；",{"key":27,"text":243,"correct":32},"1250kA；",{"key":30,"text":245,"correct":22},"1500kA。",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":27,"analysis":33},1022019,"高压隔离开关选择技术条件，下列所列各项中可以不需要考虑的是（）。",[250,252,254,256],{"key":20,"text":251,"correct":22},"电流、电压；",{"key":24,"text":253,"correct":22},"动稳定电流、热稳定电流和持续时间；",{"key":27,"text":255,"correct":32},"开断电流、操作循环；",{"key":30,"text":257,"correct":22},"接线端子的机械荷载，",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":24,"analysis":33},1022020,"关于高压隔离开关装设地点和方式的说法不合适的是（）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"中小型发电机出口一般应装设隔离开关；",{"key":24,"text":265,"correct":32},"容量为200MW及以上大型机组与双绕组变压器为单元连接时，其出口一般均应装设隔离开关；",{"key":27,"text":267,"correct":22},"在出线装设电抗器的6~1OkV配电装置中，当向不同用户供电的两因线共用一台断路器一组电抗器时，每回线上各装一组出线隔离开关；",{"key":30,"text":269,"correct":22},"中性点直接接地的自耦变压器中性点接地不必装设隔离开关。",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":27,"analysis":33},1022021,"下面几种电压屋外双柱、三柱式隔离开关施加于其接线端子的允许水平拉力，错误的是（）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"1OkV及以下，250N；",{"key":24,"text":277,"correct":22},"35~63kV，500N；",{"key":27,"text":279,"correct":32},"11OkV,800N；",{"key":30,"text":281,"correct":22},"220kV,1000N.",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":24,"analysis":33},1022022,"关于隔离开关的使用方式，正确的是（）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"接在母线上的避雷器和电压互感器宜合用一组隔离开关；",{"key":24,"text":289,"correct":32},"接在发电机或主变压器引出线或发电机中性点的避雷器，不宜装设隔离开关；",{"key":27,"text":291,"correct":22},"当主变压器的中性点接地方式采用接地或经消弧线圈接地时，应经隔离开关接地；",{"key":30,"text":293,"correct":22},"对330~500kV线路上电压互感器应装设隔离开关。",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":27,"analysis":33},1022023,"关于接地开关或接地器的配置，下面说法有误的是（）。",[298,300,302,304],{"key":20,"text":299,"correct":22},"母线接地开关，宜装在母线电压互感器的隔离开关上和母联隔离开关上；",{"key":24,"text":301,"correct":22},"63kV及以上配电装置的断路器的两侧隔离开关和线路隔离开关的线路侧，宜配置接地开关；",{"key":27,"text":303,"correct":32},"旁路母线一般装设一组接地开关，设在旁路田路的隔离开关上任意一侧；",{"key":30,"text":305,"correct":22},"63kV及以上主变压器进线隔离开关的主变压器侧宜装设一组接地开关。",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":20,"analysis":33},1022024,"关于断路器的配置，下面说法有误的是（）。",[310,312,314,316],{"key":20,"text":311,"correct":32},"容量为125MW及以下的发电机与双绕组变压器为单元连接时，在发电机与变压器之间宜装设断路器；",{"key":24,"text":313,"correct":22},"容量为125MW及以下的发电机与三绕组变压器或自耦变压器为单元连接时，在发电机与变压器之间宜装设断路器；",{"key":27,"text":315,"correct":22},"容量为200~300MW的发电机与双绕组变压器为单元连接时，发电机与变压器之间不宜装设断路器；",{"key":30,"text":317,"correct":22},"两台发电机与一台变压器作扩大单元连接时，在发电机与变压器之间应装设断路器。",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":30,"analysis":33},1022025,"关于髙压熔断器选择原则，叙述不确切的是（）。",[322,324,326,328],{"key":20,"text":323,"correct":22},"熔体的额定电流应按高压熔断器的保护特性选择，应满足保护的可靠性、选择性和灵敏庋的要求；",{"key":24,"text":325,"correct":22},"熔体的額定电流选择过大，将延长熔断时间、降低灵敏度和选择性；",{"key":27,"text":327,"correct":22},"C熔体的額定电流选择过小，则不能保证保护的可靠性；",{"key":30,"text":329,"correct":32},"熔体的额定电流选择，应在最短的时间内切断故障，以防止熔断时间过长而加剧被保护电器的损坏。",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":27,"analysis":33},1022026,"保护35kV及以下电力变压器的高压熔断器的熔体，下面选择原则有误的是（）.",[334,336,338,340],{"key":20,"text":335,"correct":22},"电力变压器回路最大工作电流通过熔体时，不应熔断；",{"key":24,"text":337,"correct":22},"电力变压器的励磁涌流通过熔体时，不应熔断；",{"key":27,"text":339,"correct":32},"熔断器熔体，通过任何地点短路时，应该熔断；",{"key":30,"text":341,"correct":22},"电动机自启动引起的冲击电流时不应熔断。",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":20,"analysis":33},1022027,"I IN=KI bgm是35kV及以下电力变压器选择高压熔断器溶体额定电流计算公式，系数满足（）。",[346,348,350,352],{"key":20,"text":347,"correct":32},"不考虑电动机启动时的K为1.1~1.3，考虑电动机自启动时的K为1.5~2.0；",{"key":24,"text":349,"correct":22},"不考虑电动机启动时的K为1.1~1.3，考虑电动机自启动时的K为1.8~2.2；",{"key":27,"text":351,"correct":22},"不考虑电动机启动时的K为1.5~2.0，考虑电动机自启动时的K为1.8~2.2；",{"key":30,"text":353,"correct":22},"不考虑电动机启动时的K为2.2，考虑电动机自启动时的K为2.5。",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":24,"analysis":33},1022028,"电力变压器中性点电流互感器的一次额定电流应大于变压器允许的不平衡电流，一般可按变压器额定电流的（）选择。",[358,359,361,363],{"key":20,"text":145,"correct":22},{"key":24,"text":360,"correct":32},"30%；",{"key":27,"text":362,"correct":22},"40%；",{"key":30,"text":364,"correct":22},"45%。",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":20,"analysis":33},1022029,"装在电力变压器中性点放电间隙回路中的电流互感器，一次额定电流可按（）选用。",[369,371,373,375],{"key":20,"text":370,"correct":32},"100A；",{"key":24,"text":372,"correct":22},"150A；",{"key":27,"text":374,"correct":22},"200A；",{"key":30,"text":376,"correct":22},"250A。",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":27,"analysis":33},1022030,"关于电流互感器的准确度，下列用法不合适的是（）。",[381,383,385,387],{"key":20,"text":382,"correct":22},"用于电度计量的电流互感器，准确度不应低于0.5级；",{"key":24,"text":384,"correct":22},"用于500kV的电度计量的电流互感器，准确度宜为0.2级；",{"key":27,"text":386,"correct":32},"用于电流电压测量的准确度，不应低于3级；",{"key":30,"text":388,"correct":22},"TP级电流互感器用于继电保护。",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":27,"analysis":33},1022031,"关于电压互感器选择，下列选择有误的是（）。",[393,395,397,399],{"key":20,"text":394,"correct":22},"3~20kV配电装里一般采用油浸绝缘结构，在高压开关拒内可采用树脂浇注绝缘结构；",{"key":24,"text":396,"correct":22},"用于中性点直接接地系统的电压互感器，其第三绕组电压应为100V；",{"key":27,"text":398,"correct":32},"用于中性点非直接接地系统的电压互感器，其第三绕组电压应为1OO\u002F√3V",{"key":30,"text":400,"correct":22},"用于接在11OkV及以上线路侧的电压互感器，当线路上装有栽波通信时，应尽量与耦合电容量结合，统一选用电容式电压互感器。",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":30,"analysis":33},1022032,"关于SF 6封闭式组合电器的使用环境和条件，叙述有误的是（）。",[405,407,409,411],{"key":20,"text":406,"correct":22},"在大城市中心地区的变电所采用；",{"key":24,"text":408,"correct":22},"地下式配电装置；",{"key":27,"text":410,"correct":22},"布置场所特别狭窄的地区；",{"key":30,"text":412,"correct":32},"环境湿度低于-40℃的地区，但应附加电热装置。",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":33},1022033,"在海拔高度为1OOOm及以下的一级污秽地区，当采用X-4.5或XP-6型悬式绝缘子时，35kV耐张绝缘子串片数不宜少于（）。",[417,419,421,423],{"key":20,"text":418,"correct":22},"3片；",{"key":24,"text":420,"correct":32},"4片；",{"key":27,"text":422,"correct":22},"5片；",{"key":30,"text":424,"correct":22},"6片.",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":20,"analysis":33},1022034,"在海拔1OOOm及以下空气清洁无明显污秽的地区，11OkV悬垂绝缘子串的片数为不宜少于（）。",[429,431,433,435],{"key":20,"text":430,"correct":32},"7片；",{"key":24,"text":432,"correct":22},"8片；",{"key":27,"text":434,"correct":22},"9片；",{"key":30,"text":436,"correct":22},"10片。",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":30,"analysis":33},1022035,"在海拔髙度为1OOOm及以下地区，按操作过电压及雷电过电压要求，220kV耐张绝缘子单片的髙度为146mm时，耐张绝缘子串不应少于（）。",[441,443,445,447],{"key":20,"text":442,"correct":22},"11片；",{"key":24,"text":444,"correct":22},"12片；",{"key":27,"text":446,"correct":22},"13片；",{"key":30,"text":448,"correct":32},"14片。",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":24,"analysis":33},1022036,"泪弧线圈过补偿的补偿容量的计算公式为（）",[453,454,455,456],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":32},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":30,"analysis":33},1022037,"中性点经消弧线圈接地的电网，在正常情况下，长时间中性点位移电压不应超过额定相电压的（）",[461,463,465,467],{"key":20,"text":462,"correct":22},"10%；",{"key":24,"text":464,"correct":22},"12%；",{"key":27,"text":466,"correct":22},"13%；",{"key":30,"text":468,"correct":32},"15%。",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":27,"analysis":33},1022038,"安装在YNd接线双绕组或YNynd接线三绕组变压器中性点上的消弧线圈的容量，不应趙过变压器总容量的（），并且不得大于三绕组的任一绕组的容量。",[473,475,477,479],{"key":20,"text":474,"correct":22},"40%,",{"key":24,"text":476,"correct":22},"45%；",{"key":27,"text":478,"correct":32},"50%；",{"key":30,"text":480,"correct":22},"55%,",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":20,"analysis":33},1022039,"对于选择安装于屋外的电器，环境温度宜采用（）。",[485,487,489,491],{"key":20,"text":486,"correct":32},"年最高温度（多年平均值）；",{"key":24,"text":488,"correct":22},"最高月平均温度（多年平均值）；",{"key":27,"text":490,"correct":22},"最热月平均最高温度（多年平均值）",{"key":30,"text":492,"correct":22},"多年极端最高温度。",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":24,"analysis":33},1022040,"在荷载长期作用及短时作用情况下，选择支柱绝缘子的力学安全系数应分别取（）。",[497,499,501,503],{"key":20,"text":498,"correct":22},"2.0，1.67；",{"key":24,"text":500,"correct":32},"2.5,1.67；",{"key":27,"text":502,"correct":22},"4，2.5；",{"key":30,"text":504,"correct":22},"5.3,3.3。",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":24,"analysis":33},1022041,"对高压断路器，进行电晕校验的电压等于（）。",[509,511,513,515],{"key":20,"text":510,"correct":22},"1.1倍断路器額定电压；",{"key":24,"text":512,"correct":32},"1.1\u002F√3倍断路器額定电压；",{"key":27,"text":514,"correct":22},"1.1倍电网額定电压；",{"key":30,"text":516,"correct":22},"1.1\u002F√3倍电网額定电压。",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":20,"analysis":33},1022042,"以下髙压设备需要校验短路热稳定的有（）。",[521,523,525,527],{"key":20,"text":522,"correct":32},"负荷开关；",{"key":24,"text":524,"correct":22},"电压互感器；",{"key":27,"text":526,"correct":22},"熔断器；",{"key":30,"text":528,"correct":22},"支柱绝缘子，",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":24,"analysis":33},1022043,"对于电气设备动热稳定的校验，以下说法不正确的是（）。",[533,535,537,539],{"key":20,"text":534,"correct":22},"开关类设备必须校验热稳定和动稳定；",{"key":24,"text":536,"correct":32},"互感器类设备必须校验热稳定和动稳定；",{"key":27,"text":538,"correct":22},"绝缘子不需校驗热稳定；",{"key":30,"text":540,"correct":22},"消弧线面不需校猃热稳定和动稳定。",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":27,"analysis":33},1022044,"对于发电厂主变压器的选择，以下说法错误的是（）。",[545,547,549,551],{"key":20,"text":546,"correct":22},"受运输条件眼制时，300MW及以下发电机组的主变压器也可选用单相变压器组；",{"key":24,"text":548,"correct":22},"容量为200MW的机组不宜采用三绕组变压器；",{"key":27,"text":550,"correct":32},"容量为1OOMW的机組以两种升高电压向用户供电或与电力系统连接时，应采用三绕组变压器；",{"key":30,"text":552,"correct":22},"发电机升压变压器不能选用自耦变压器。",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":27,"analysis":33},1022045,"装设在变压器中性点的消弧线圈，其补偿方式应为（）。",[557,559,561,563],{"key":20,"text":558,"correct":22},"补偿容量应与系统中总的电容量相等；",{"key":24,"text":560,"correct":22},"欠补偿；",{"key":27,"text":562,"correct":32},"过补偿；",{"key":30,"text":564,"correct":22},"只要补偿系数合适，欠补偿和过补偿都可以。",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":30,"analysis":33},1022046,"220~330kV断路器接线端子应能承受的静态拉力为（ ）。",[569,571,573,575],{"key":20,"text":570,"correct":22},"纵向水平拉力1000N,横向水平拉力750N，垂直力750N；",{"key":24,"text":572,"correct":22},"纵向水平拉力2000N，横向水平拉力700N，垂直力500N；",{"key":27,"text":574,"correct":22},"纵向水平拉力1250N，横向水平拉力750N，垂直力1000N；",{"key":30,"text":576,"correct":32},"纵向水平拉力1500N,横向水平拉力1000N，垂釓力1250N。",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":24,"analysis":33},1022047,"550kV隔离开关切合电容电流的能力应不小于（）。",[581,583,585,587],{"key":20,"text":582,"correct":22},"0.5A；",{"key":24,"text":584,"correct":32},"1A；",{"key":27,"text":586,"correct":22},"2A；",{"key":30,"text":588,"correct":22},"4A。",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":30,"analysis":33},1022048,"在我国的330kV双母线接线系统中，母线电压互感器的变比应选择（ ）（只考虑1个主二次绕组和1个辅助二次绕组）。",[593,594,595,596],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":32},{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":20,"analysis":33},1022049,"交流系统中电力电缆缆芯的相间额定电压，不得低于使用回路的工作()。",[601,603,605,607],{"key":20,"text":602,"correct":32},"线电压；",{"key":24,"text":604,"correct":22},"相电压；",{"key":27,"text":606,"correct":22},"工頻过电压；",{"key":30,"text":608,"correct":22},"冲击电压，",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]