[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-53":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":589},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,53,50,2670,[13,35,48,61,74,83,95,108,121,133,145,158,170,179,191,203,216,228,240,252,263,275,287,295,303,311,323,334,346,358,366,374,382,394,406,418,430,442,454,466,478,490,502,514,524,533,545,553,565,577],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1024831,2,"多选题","交流单相回路的电力电缆的外护层，不得有未经磁性处理的（）",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","膨胀式阻水层；",false,{"key":24,"text":25,"correct":22},"B","挤塑外套",{"key":27,"text":28,"correct":29},"C","金属带；",true,{"key":31,"text":32,"correct":29},"D","钢丝铠装","CD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1024835,"直埋电缆承受较大压力或有机械损伤危险时，外护层应有（）。",[39,41,43,45],{"key":20,"text":40,"correct":29},"加强层；",{"key":24,"text":42,"correct":22},"挤塑外套；",{"key":27,"text":44,"correct":22},"铅管；",{"key":31,"text":46,"correct":29},"钢带铠装。","AD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},1024839,"电缆终端的机械强度，应满足安置处（）作用的要求。",[52,54,56,58],{"key":20,"text":53,"correct":22},"热膨胀力；",{"key":24,"text":55,"correct":29},"引线拉力；",{"key":27,"text":57,"correct":29},"风力；",{"key":31,"text":59,"correct":29},"地震力","BCD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},1024843,"电缆接头的构造类型选择，应按连接电缆的（），满足工程的所需可靠性和经济 合理。",[65,67,69,71],{"key":20,"text":66,"correct":29},"绝缘类型；",{"key":24,"text":68,"correct":22},"气象条件；",{"key":27,"text":70,"correct":29},"安置条件",{"key":31,"text":72,"correct":29},"作业条件。","ACD",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":82,"analysis":34},1024846,"交流系统用单芯电力电缆的（），应同时满足电缆金属护层正常或感应电压不超 过允许值，并使按持续工作电流选择电缆截面尽可能较小的原则来确定. A.金属屏蔽线； B.相序配里； C相间距离； D.罩盒。",[78,79,80,81],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},"BC",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":33,"analysis":34},1024851,"在（）的土壤范围,电缆不得采取直埋敷设方式。",[87,89,91,93],{"key":20,"text":88,"correct":22},"厂区管网较多的地方；",{"key":24,"text":90,"correct":22},"待开发将有频繁开挖的地方；",{"key":27,"text":92,"correct":29},"C化学腐蚀；",{"key":31,"text":94,"correct":29},"杂散电源腐蚀。",{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":97,"options":98,"answer":107,"analysis":34},1024854,"在（）的场所，或有载重车辆频繁经过的地面，不得用电缆沟进行电缆敷设。",[99,101,103,105],{"key":20,"text":100,"correct":29},"有化学腐蚀液体；",{"key":24,"text":102,"correct":29},"有高温熔化金属溢流",{"key":27,"text":104,"correct":22},"地下电缆较多；",{"key":31,"text":106,"correct":22},"城镇人行道开挖不便。","AB",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":120,"analysis":34},1024857,"电缆在（）的场所，厂房内应采用支持式架空敷设。",[112,114,116,118],{"key":20,"text":113,"correct":29},"地下水位较高；",{"key":24,"text":115,"correct":22},"交通流量较大；",{"key":27,"text":117,"correct":29},"化学腐蚀液体溢流；",{"key":31,"text":119,"correct":22},"各种管线较多。","AC",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":60,"analysis":34},1024861,"直埋电缆与铁路、公路或街道交叉时，应穿于保护管中，且保护范围超出（） 0. 5m以上。",[125,127,129,131],{"key":20,"text":126,"correct":22},"交通标志边",{"key":24,"text":128,"correct":29},"路基；",{"key":27,"text":130,"correct":29},"街道路两边；",{"key":31,"text":132,"correct":29},"排水沟边",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":107,"analysis":34},1024865,"水下电缆相互间严禁（），相邻电缆应保持足够的安全间距.",[137,139,141,143],{"key":20,"text":138,"correct":29},"交叉；",{"key":24,"text":140,"correct":29},"重查；",{"key":27,"text":142,"correct":22},"平行；",{"key":31,"text":144,"correct":22},"连接。",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":157,"analysis":34},1024868,"电气设施布置应根据（）和其他环境条件，并结合电气总布置及运行、检修条 件，通过技术经济分析确定。",[149,151,153,155],{"key":20,"text":150,"correct":22},"电气设备；",{"key":24,"text":152,"correct":29},"设防烈度；",{"key":27,"text":154,"correct":22},"出线方向；",{"key":31,"text":156,"correct":29},"场地条件。","BD",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":47,"analysis":34},1024872,"当抗震设防烈度为7度及以上时,（）应进行抗震设计",[162,164,166,168],{"key":20,"text":163,"correct":29},"电压等级为300kV及以上的电气设施；",{"key":24,"text":165,"correct":22},"电压等级为200kV及以上的电气设施；",{"key":27,"text":167,"correct":22},"电压等级为110kV及以上的电气设施；",{"key":31,"text":169,"correct":29},"安装屋内二层及以上和屋外高架平台上的电气设施。",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":178,"analysis":34},1024876,"电力设备和线路应有（）必要时可增设辅助保护。 A.主保护； B.后备保护； C异常运行保护； D.信号保护。",[174,175,176,177],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},"ABC",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":73,"analysis":34},1024880,"断电保护和自动装置应满足（）和速动性的要求，并应符合其他规定。",[183,185,187,189],{"key":20,"text":184,"correct":29},"可靠性；",{"key":24,"text":186,"correct":22},"广泛性；",{"key":27,"text":188,"correct":29},"选择性；",{"key":31,"text":190,"correct":29},"灵敏性。",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":33,"analysis":34},1024884,"在安装各种设备（）的联锁接点、端子排和接地时，应能在不断开3kV及以上一次线情况下,保证在二次回路端子排上安全工作。",[195,197,199,201],{"key":20,"text":196,"correct":22},"信号装置；",{"key":24,"text":198,"correct":22},"监视屏；",{"key":27,"text":200,"correct":29},"断路器；",{"key":31,"text":202,"correct":29},"隔离开关",{"id":204,"libraryId":5,"type":15,"typeLabel":16,"stem":205,"options":206,"answer":215,"analysis":34},1024888,"配电装置的布置和（）的选择，应满足在当地环境条件下正常运行、安装维修、 短路和过电压状态的要求。",[207,209,211,213],{"key":20,"text":208,"correct":29},"导体；",{"key":24,"text":210,"correct":29},"电器；",{"key":27,"text":212,"correct":22},"保护方式；",{"key":31,"text":214,"correct":29},"架构。","ABD",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":33,"analysis":34},1024891,"充油电气设备的布置，应满足在常电时观察（）的安全和方便的要求，并便于抽 取油样。",[220,222,224,226],{"key":20,"text":221,"correct":22},"油品；",{"key":24,"text":223,"correct":22},"油色；",{"key":27,"text":225,"correct":29},"油位；",{"key":31,"text":227,"correct":29},"油温",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":215,"analysis":34},1024896,"当电压等级为63?110kV时，（〉应装设在有防爆隔墙的间隔内。",[232,234,236,238],{"key":20,"text":233,"correct":29},"屋内断路器",{"key":24,"text":235,"correct":29},"油浸式电流互感器；",{"key":27,"text":237,"correct":22},"干式变压器；",{"key":31,"text":239,"correct":29},"电压互感器。",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":60,"analysis":34},1024899,"充油型电气设备，应在（）的条件下采用。",[244,246,248,250],{"key":20,"text":245,"correct":22},"没有地震；",{"key":24,"text":247,"correct":29},"没有振动；",{"key":27,"text":249,"correct":29},"不会倾斜；",{"key":31,"text":251,"correct":29},"固定安装。",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":215,"analysis":34},1024903,"爆炸性粉尘环境进行电气线路设计和安装时，电缆选用应考虑（）以及周围环境 温度及用电设备进线盒方式等因素。",[256,258,260,261],{"key":20,"text":257,"correct":29},"环境腐蚀；",{"key":24,"text":259,"correct":29},"鼠类危害；",{"key":27,"text":57,"correct":22},{"key":31,"text":262,"correct":29},"白议危害。",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":47,"analysis":34},1024907,"在火灾危险的环境内，（）线路的绝缘导线和电缆的额定电压，不应低于线路的 额定电压且不低于500V",[267,269,271,273],{"key":20,"text":268,"correct":29},"电力；",{"key":24,"text":270,"correct":22},"通信；",{"key":27,"text":272,"correct":22},"报警；",{"key":31,"text":274,"correct":29},"照明。",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":60,"analysis":34},1024910,"第一类防雷建筑物采取防直接雷措施时，（）至少设一根引下线。",[279,281,283,285],{"key":20,"text":280,"correct":22},"避雷带的各支点；",{"key":24,"text":282,"correct":29},"独立避雷针的杆塔",{"key":27,"text":284,"correct":29},"架空避雷线的端部；",{"key":31,"text":286,"correct":29},"架空避雷网的各支柱处。",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":73,"analysis":34},1024914,"第二类防雷建筑物采取防直接雷措施时，应按要求沿（）和槍角等易受雷击部分 敷设避雷网（带) A.屋脊； B.屋面； C屋角； D.屋檐。",[291,292,293,294],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":29},{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":157,"analysis":34},1024918,"第三类防雷建筑物按规定敫设避雷网（带），并应在屋面组成不大于（）的网格。 A. 30mX30m； B. 20mX 20m； C 15mX25m； D. 24mX16m。",[299,300,301,302],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":60,"analysis":34},1024921,"埋于土壤中的人工垂直接地体宜采用（）。 A.扁钢； B.角钢； C钢管； D圆钢。",[307,308,309,310],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":29},{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":215,"analysis":34},1024925,"配电室的位置应靠近用电负荷中心，设置在（）和振动轻微的地方，并宜适当留 有发展余地。",[315,317,319,321],{"key":20,"text":316,"correct":29},"尘埃少；",{"key":24,"text":318,"correct":29},"腐蚀介质少；",{"key":27,"text":320,"correct":22},"噪声低；",{"key":31,"text":322,"correct":29},"干燥。",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":60,"analysis":34},1024929,"电缆排管敷设在（）时，应设电缆人孔井。",[327,328,330,332],{"key":20,"text":138,"correct":22},{"key":24,"text":329,"correct":29},"转角；",{"key":27,"text":331,"correct":29},"分支；",{"key":31,"text":333,"correct":29},"变更敷设方式为直埋或电缆沟敷设",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":215,"analysis":34},1024932,"选择竖井位置时应符合（）等要求，",[338,340,342,344],{"key":20,"text":339,"correct":29},"靠近负荷中心，尽可能减少干线电缆长度；",{"key":24,"text":341,"correct":29},"不应和电梯、管道间共用一竖并；",{"key":27,"text":343,"correct":22},"不和通风共用一竖井；",{"key":31,"text":345,"correct":29},"避免靠近烟囱、热力管道及其他散热量大或湖湿的设施。",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":178,"analysis":34},1024936,"竖井内的（）的电气线路，相互之间的距离应不小于300mm,或采用隔离措施， 并且高压线路应设有明显标志。",[350,352,354,356],{"key":20,"text":351,"correct":29},"高压；",{"key":24,"text":353,"correct":29},"低压；",{"key":27,"text":355,"correct":29},"应急电源；",{"key":31,"text":357,"correct":22},"通信。",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":60,"analysis":34},1024939,"屋外配电装置带电部分的上面和下面，不应有（）线路架空跨越或穿越。 A.动力； B.照明； C通信； D.信号。",[362,363,364,365],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":29},{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":215,"analysis":34},1024943,"屋外配电装置的构架设计应考虑芷常运行、安装、检修时的各种荷载组合，正常运 行时，应取设计（）三种情况中最严重者。 A.最大风速； B.最低气温； C最大地震力； D.最厚覆冰。",[370,371,372,373],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":73,"analysis":34},1024947,"能对地构成电流闭合回路的直流电力回路中，不得利用自然接地体作为电流回路的( ). A.零线; B.中性线； C接地线； D.接地体。",[378,379,380,381],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":29},{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":73,"analysis":34},1024950,"符合下列情况者（）应设为一级负荷。",[386,388,390,392],{"key":20,"text":387,"correct":29},"中断供电将造成人身伤亡时；",{"key":24,"text":389,"correct":22},"中断供电将造成用电户財产大量损失；",{"key":27,"text":391,"correct":29},"C中断供电将在政治、经济上造成重大损失时；",{"key":31,"text":393,"correct":29},"中断供电将影响有重大政治、经济意义的用电单位的正常工作。",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":82,"analysis":34},1024954,"对100MW及以上的汽轮发电机变压器组，应装设双重主保护，多套保护宜具有 ( )。",[398,400,402,404],{"key":20,"text":399,"correct":22},"电流速断保护；",{"key":24,"text":401,"correct":29},"发电机纵联差动保护；",{"key":27,"text":403,"correct":29},"C变压器纵联差动保护；",{"key":31,"text":405,"correct":22},"发电机变压器组共用纵联差动保护。",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":60,"analysis":34},1024958,"300MW及以上发电机宜装设失步保护，保护可由双阻抗元件或测量振动中心电压 变化率等原理构成，在（）等情况下，保护不应误动作。",[410,412,414,416],{"key":20,"text":411,"correct":22},"程序跳闸；",{"key":24,"text":413,"correct":29},"短路故障；",{"key":27,"text":415,"correct":29},"系统稳定振荡",{"key":31,"text":417,"correct":29},"电压回路断线。",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":178,"analysis":34},1024961,"对变压器（），应按有关规定装设相应保护为主保护，保护瞬时动作于断开变压 器的各侧断路器。",[422,424,426,428],{"key":20,"text":423,"correct":29},"引出线路故障；",{"key":24,"text":425,"correct":29},"套管短路故障；",{"key":27,"text":427,"correct":29},"C内部短路故障；",{"key":31,"text":429,"correct":22},"产生大量瓦斯。",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":215,"analysis":34},1024964,"在电力系统中，应装设安全自动装置，以防止（）。",[434,436,438,440],{"key":20,"text":435,"correct":29},"系统稳定破坏或亊故扩大；",{"key":24,"text":437,"correct":29},"造成大面积停电；",{"key":27,"text":439,"correct":22},"造成设备损坏；",{"key":31,"text":441,"correct":29},"对重要用户的供电长时间中断。",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":178,"analysis":34},1024969,"自动投入装置应符合以下要求（)",[446,448,450,452],{"key":20,"text":447,"correct":29},"应保证在工作电源或设备断开后，才投入备用电源或设备；",{"key":24,"text":449,"correct":29},"工作电源或设备上的电压，不论因任何原因消失时，自动投入装置均应动作；",{"key":27,"text":451,"correct":29},"自动投入装里应保证只动作一次；",{"key":31,"text":453,"correct":22},"自动投入装置应有保护和记录。",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":215,"analysis":34},1024972,"电力系统应按规定装设控制保护和安全自动装置，为了保持系统稳定，对功率过剩 与频率上升一侧采取以下自动措施（）。",[458,460,462,464],{"key":20,"text":459,"correct":29},"对发电机快速减力；",{"key":24,"text":461,"correct":29},"切除部分发电机；",{"key":27,"text":463,"correct":22},"在预定地点将系统解列；",{"key":31,"text":465,"correct":29},"投入动态电阻制动。",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":73,"analysis":34},1024976,"6kV或10kV屋内配电装置到各用户去的（）等，宜采用就地控制。",[470,472,474,476],{"key":20,"text":471,"correct":29},"线路；",{"key":24,"text":473,"correct":22},"全厂的公用设备；",{"key":27,"text":475,"correct":29},"供辅助车间用的厂用变压器；",{"key":31,"text":477,"correct":29},"交流亊故保安电源",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":47,"analysis":34},1024980,"厂用电动机宜采用（）的交流电动机。",[482,484,486,488],{"key":20,"text":483,"correct":29},"高效；",{"key":24,"text":485,"correct":22},"安全；",{"key":27,"text":487,"correct":22},"低噪；",{"key":31,"text":489,"correct":29},"节能",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":73,"analysis":34},1024984,"电动机用于特殊环境，如（）等时，应选用相应的专用电动机。",[494,496,498,500],{"key":20,"text":495,"correct":29},"髙原；",{"key":24,"text":497,"correct":22},"严寒地区；",{"key":27,"text":499,"correct":29},"热带；",{"key":31,"text":501,"correct":29},"户外。",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":215,"analysis":34},1024988,"厂用电抗器宜装设下列保护（）。",[506,508,510,512],{"key":20,"text":507,"correct":29},"纵联差动保护；",{"key":24,"text":509,"correct":29},"过电流保护；",{"key":27,"text":511,"correct":22},"电源速断保护",{"key":31,"text":513,"correct":29},"单相接地保护。",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":33,"analysis":34},1024992,"3?10kV厂用线路应装设下列保护（)。",[518,520,521,523],{"key":20,"text":519,"correct":22},"过负荷保护；",{"key":24,"text":509,"correct":22},{"key":27,"text":522,"correct":29},"C相间短路保护；",{"key":31,"text":513,"correct":29},{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":73,"analysis":34},1024995,"柴油发电机应装设下列保护（）。",[528,529,530,531],{"key":20,"text":509,"correct":29},{"key":24,"text":519,"correct":22},{"key":27,"text":507,"correct":29},{"key":31,"text":532,"correct":29},"单相接地保护",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":60,"analysis":34},1024999,"蓄电池室应使用防爆型照明和防爆型排风机的（）等，并应装在蓄电池室外面。",[537,539,541,543],{"key":20,"text":538,"correct":22},"排风管；",{"key":24,"text":540,"correct":29},"开关；",{"key":27,"text":542,"correct":29},"熔断器；",{"key":31,"text":544,"correct":29},"插座",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":215,"analysis":34},1025003,"厂用电负荷宜装设单独保护器，但下列情况（）也可数个负荷共用一套保护 箱，但应保证能迅速切除任一个负荷的短路故障。 A.工艺上密切相关的一组电动机 B不重要负荷；C.单个大容量负荷； D.不经常运行且容量不大的负荷。",[549,550,551,552],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":60,"analysis":34},1025007,"送电线路位于（）以及山谷口等容易产生强风地带时，其最大设计风速应较附近 —般地区适当增大。",[557,559,561,563],{"key":20,"text":558,"correct":22},"海边；",{"key":24,"text":560,"correct":29},"河岸",{"key":27,"text":562,"correct":29},"湖岸；",{"key":31,"text":564,"correct":29},"高峰",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":33,"analysis":34},1025010,"地线应满足电气和机械使用条件要求，可选用（）之一。",[569,571,573,575],{"key":20,"text":570,"correct":22},"钢芯铝绞线；",{"key":24,"text":572,"correct":22},"钢芯铝合金绞线；",{"key":27,"text":574,"correct":29},"镀锌钢绞线；",{"key":31,"text":576,"correct":29},"复合型纹线。",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":73,"analysis":34},1025015,"各类杆塔的正常运行情况下，应计算下列荷载组合（）。",[581,583,585,587],{"key":20,"text":582,"correct":29},"最大风速、无冰、未断线；",{"key":24,"text":584,"correct":22},"最高气温、最大风速、未断线；",{"key":27,"text":586,"correct":29},"最大覆冰、相应风速及气温、未断线；",{"key":31,"text":588,"correct":29},"最低气温、无冰、无风、未断线（适用于终端和转角杆塔，不含大跨越直线塔)。",[590,594,597,600,603,606],{"id":591,"name":592,"category":7,"favorite":593},1,"领导干部任职前廉政法规知识测试题",92,{"id":595,"name":596,"category":7,"favorite":591},595,"建筑结构与设备",{"id":598,"name":599,"category":7,"favorite":591},715,"招标采购专业知识与法律法规",{"id":601,"name":602,"category":7,"favorite":591},848,"市政方向-通用基础",{"id":604,"name":605,"category":7,"favorite":8},534,"BIM工程师",{"id":607,"name":605,"category":7,"favorite":8},535]