[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-51":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":630},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,51,50,2670,[13,35,48,60,72,85,98,111,124,136,148,161,173,185,197,209,221,233,245,257,269,282,294,306,318,330,342,354,366,378,390,401,412,424,436,448,461,473,486,498,510,522,534,546,558,570,582,594,606,618],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1024465,2,"多选题","选择应急灯时下列要求正确的是（）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","应急灯的放电时间应按1h计算；",true,{"key":24,"text":25,"correct":22},"B","应急灯充电电源，宜接在220V交流回路上，宜采用插座连接方式；",{"key":27,"text":28,"correct":29},"C","应急灯的放电时间应按计算；",false,{"key":31,"text":32,"correct":29},"D","应急灯宜选用隔爆式。","AB","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1024468,"室内照明灯具布置时，下列要求正确的是（）。",[39,41,43,45],{"key":20,"text":40,"correct":29},"使整个房间或房间的部分区域内照度均匀，边排照明灯具距墙的距离可取0.3L~0.6L（L为灯具的间距）；",{"key":24,"text":42,"correct":22},"应限制直接眩光和反射眩光；",{"key":27,"text":44,"correct":22},"应便于维护和安全检修；",{"key":31,"text":46,"correct":22},"应与建筑相互协调。","BCD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":33,"analysis":34},1024471,"控制室照明灯具宜遵循的原则是（）。",[52,54,56,58],{"key":20,"text":53,"correct":22},"小型控制室及无人值班控制室宜采用嵌入式或吸顶式荧光灯具；",{"key":24,"text":55,"correct":22},"中型控制室宜采用嵌入式阻燃栅格荧光灯光带、光块式发光天棚；",{"key":27,"text":57,"correct":29},"可采用花式吊灯照明；",{"key":31,"text":59,"correct":29},"可采用中配光的灯具。",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":33,"analysis":34},1024473,"髙建筑物航空障碍标志灯的装设原则是（）。",[64,66,68,70],{"key":20,"text":65,"correct":22},"在机场的内水平面，当高度在45m以上的建筑物和构筑物必须设里航空障碍标志灯；",{"key":24,"text":67,"correct":22},"在机场净空区的锥形面内，从内水平面边缘向外，沿其径轴线，高度由45m逐渐递増至145m高的建筑物和构筑物应装设航空障碍标志灯；",{"key":27,"text":69,"correct":29},"在上述锥形面以外的地区，高出地面髙程达160m及以上的建筑物和构筑物应装设航空障碍标志灯；",{"key":31,"text":71,"correct":29},"在机场的外水平面，当高度在45m以上的建筑物和构筑物必须设里航空障碍标志灯。",{"id":73,"libraryId":5,"type":15,"typeLabel":16,"stem":74,"options":75,"answer":84,"analysis":34},1024476,"航空障碍标志灯装设位置应符合（）。",[76,78,80,82],{"key":20,"text":77,"correct":29},"当建筑物髙出地面45m及以上时，还应在中部増设，増设的中间灯应尽可能自顶至地面等距离设置，当为低或中光强灯时，间距不应大于60m；省为高光铎灯时，间距不应大于80m；",{"key":24,"text":79,"correct":29},"烟囱顶部的顶灯应设在顶部端以下3~5m之间；",{"key":27,"text":81,"correct":22},"低、中光铎降碍标志灯应为红色玻璃灯罩，高光强障碍标志灯应为白色闪光，烟囱每层4个，互成90°,并宜采用自动换泡装里；",{"key":31,"text":83,"correct":22},"其他高建筑物和筑物航空障碍灯的装设应依工程具体情况而定。","CD",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":97,"analysis":34},1024479,"下列关于开关、插座的选择、原则，正确的是（）。",[89,91,93,95],{"key":20,"text":90,"correct":22},"对不同电压等级的插座，其插孔形抉应有所区别；",{"key":24,"text":92,"correct":29},"生产车间单相插座，应为二极式；",{"key":27,"text":94,"correct":22},"在有爆炸、火灾危险的场所，不宜装设开关及插座s当需要装设时，应选用防爆型开关及梯应；",{"key":31,"text":96,"correct":22},"潮湿、多尘场所及屋外装设的开关和插座，应选用防水防尘型。","ACD",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":110,"analysis":34},1024482,"下列场所，宜用逐点计算法校验其照度值的是（）。",[102,104,106,108],{"key":20,"text":103,"correct":22},"主控制室、网络控制室、单元控制室、计算机控制屏、台上垂直面和賴斜面；",{"key":24,"text":105,"correct":22},"主厂房、化水处理室、水泵房、灰浆泵房重要设备或重要观察点；",{"key":27,"text":107,"correct":22},"反射条件较差的场所，如运煤系统；",{"key":31,"text":109,"correct":29},"办公室水平照度。","ABC",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":123,"analysis":34},1024485,"下列场所，宜采用等照度曲线法计算照度的是（）。",[115,117,119,121],{"key":20,"text":116,"correct":22},"贮煤场；",{"key":24,"text":118,"correct":22},"屋外配电装置；",{"key":27,"text":120,"correct":29},"道路；",{"key":31,"text":122,"correct":22},"码头，","ABD",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":47,"analysis":34},1024488,"道路照明和户外节能措施，正确的是（）。",[128,130,132,134],{"key":20,"text":129,"correct":29},"户外照明和道路照明，均宜采用荧光高压汞灯；",{"key":24,"text":131,"correct":22},"户外照明宜采用自动控制；",{"key":27,"text":133,"correct":22},"道路照明宜分组布置；",{"key":31,"text":135,"correct":22},"道路照明宜采用半夜节能控制方式。",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":47,"analysis":34},1024491,"照明种类可分为（）。",[140,142,144,146],{"key":20,"text":141,"correct":29},"局部照明；",{"key":24,"text":143,"correct":22},"亊故照明；",{"key":27,"text":145,"correct":22},"警卫照明；",{"key":31,"text":147,"correct":22},"障碍照明。",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":160,"analysis":34},1024494,"在气体放电灯的频闪效应对视觉作业有影响的场所，应采用下列措施之一（）。",[152,154,156,158],{"key":20,"text":153,"correct":29},"采用调光开关；",{"key":24,"text":155,"correct":22},"采用高頻电子镇流器；",{"key":27,"text":157,"correct":29},"采用节能电感镇流器；",{"key":31,"text":159,"correct":22},"相邻灯具分接在不同相序。","BD",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":97,"analysis":34},1024497,"照明灯具的最低悬挂高度，在下列房间可降低0.5m，但不应低于2.2m的是（）。",[165,167,169,171],{"key":20,"text":166,"correct":22},"一般照明照度小于301x的房间；",{"key":24,"text":168,"correct":29},"长度不超过照明灯具悬挂髙度3倍的房间；",{"key":27,"text":170,"correct":22},"人员短期停留的房间；",{"key":31,"text":172,"correct":22},"屋内配电装置。",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":110,"analysis":34},1024500,"架空送电线路设计的总体原则应（）。",[177,179,181,183],{"key":20,"text":178,"correct":22},"贯彻国家技术经济政策，做到安全可靠，经济适用，符合国情；",{"key":24,"text":180,"correct":22},"从实际出发，结合地区特点，积极慎重地推广采用成熟的新材料、新结构等先进技术；",{"key":27,"text":182,"correct":22},"符合现行有关标准、规范和电力行业标准规定的要求；",{"key":31,"text":184,"correct":29},"满足电力系统今后5~10年的发展需求。",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":110,"analysis":34},1024503,"架空送电线路的路径选择应（）。",[189,191,193,195],{"key":20,"text":190,"correct":22},"综合考虑施工、运行、交通条件和线路长度等因素，进行方案比较，做到安全可靠，经济合理；",{"key":24,"text":192,"correct":22},"尽量避开重冰区，不良地质地带，原始森林；",{"key":27,"text":194,"correct":22},"考虑与邻近设施如电台、机场、弱电线路等的相互影响；",{"key":31,"text":196,"correct":29},"对规划中的两回路和多回路线路应采用同杆塔架设。",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":97,"analysis":34},1024506,"送电线路中的大跨越，其特征是（）。",[201,203,205,207],{"key":20,"text":202,"correct":22},"跨越通航的大河流、湖泊或海峡等；",{"key":24,"text":204,"correct":29},"交通困难山区的特大档距( 1OOOm）；",{"key":27,"text":206,"correct":22},"跨越档距较大（＞1OOOm）,杆塔较高（＞lOOm）；",{"key":31,"text":208,"correct":22},"发生故障严重影响航运或修复特别因难。",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":123,"analysis":34},1024509,"送电线路导线的材质和结构的选择的一般原则是（）。",[213,215,217,219],{"key":20,"text":214,"correct":22},"有较高的导电率（但一般不考虑用铜线）；",{"key":24,"text":216,"correct":22},"有较高的机械强度、耐振性和耐化学腐蚀性；",{"key":27,"text":218,"correct":29},"满足输送容量和短路电流热稳定的要求；",{"key":31,"text":220,"correct":22},"尽量选用国家标准的定型产品。",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":33,"analysis":34},1024513,"送电线路导线截面选择时，还应校验（）等。",[225,227,229,231],{"key":20,"text":226,"correct":22},"电晕；",{"key":24,"text":228,"correct":22},"长期允许电流；",{"key":27,"text":230,"correct":29},"系统稳定；",{"key":31,"text":232,"correct":29},"短路时热稳定。",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":47,"analysis":34},1024516,"用于腐蚀性较强地区的送电线路的导线宜选用（）。",[237,239,241,243],{"key":20,"text":238,"correct":29},"钢芯铝统线；",{"key":24,"text":240,"correct":22},"防腐钢芯铝纹线；",{"key":27,"text":242,"correct":22},"铝包钢芯铭纹线；",{"key":31,"text":244,"correct":22},"铝合金绞线。",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":123,"analysis":34},1024521,"送电线路的大跨越线段或外荷载较大的重冰线段，其导线宜选用（）。",[249,251,253,255],{"key":20,"text":250,"correct":22},"加弦型钢芯铝绞线；",{"key":24,"text":252,"correct":22},"钢芯铝合金纹线；",{"key":27,"text":254,"correct":29},"铜包钢绞线；",{"key":31,"text":256,"correct":22},"铝包钢绞线。",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":33,"analysis":34},1024524,"送电线路通过腐蚀性较强地区的地线应选用（）。",[261,263,265,267],{"key":20,"text":262,"correct":22},"铝合金绞线；",{"key":24,"text":264,"correct":22},"铝包钢纹线；",{"key":27,"text":266,"correct":29},"钢芯铝绞线；",{"key":31,"text":268,"correct":29},"镀锌钢绞线。",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":281,"analysis":34},1024529,"电晕条件校验导线直径取决于（）。",[273,275,277,279],{"key":20,"text":274,"correct":22},"导线表面电场强度不大于全面电晕电场强度E0的80%~85%；",{"key":24,"text":276,"correct":29},"导线表面电场强度E大于导线临界电场强度；",{"key":27,"text":278,"correct":22},"年平均电晕损失不宜大于线路电阻有功损失的20%；",{"key":31,"text":280,"correct":29},"导线表面电场强度E小于全面电晕电场强度E0。","AC",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":33,"analysis":34},1024532,"当电晕校验不满足要求时，常用的方法是（）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"加大截面；",{"key":24,"text":289,"correct":22},"采用总截面相近的分裂导线；",{"key":27,"text":291,"correct":29},"同截面空心导线；",{"key":31,"text":293,"correct":29},"加大相间距离。",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":110,"analysis":34},1024536,"钢芯铝绞线的弹性系数E为钢芯铝绞线承受的应力在单位长度上所产生的伸长值之比，因此与以下（）因素有关。",[298,300,302,304],{"key":20,"text":299,"correct":22},"钢丝的弹性系数；",{"key":24,"text":301,"correct":22},"铝线的弹性系数；",{"key":27,"text":303,"correct":22},"铝钢截面比；",{"key":31,"text":305,"correct":29},"铝线和钢丝的拉断《度。",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":123,"analysis":34},1024540,"钢芯铝纹线的温度线膨胀系数E为钢芯铝绞线温度升髙1℃时单位长度的伸长值， 因此与以下（）因素有关。",[310,312,314,316],{"key":20,"text":311,"correct":22},"钢丝的弹性系数和线膨胀系数；",{"key":24,"text":313,"correct":22},"铝线的弹性系数和线膨胀系教；",{"key":27,"text":315,"correct":29},"铝线和钢丝的拉断强度；",{"key":31,"text":317,"correct":22},"铝钢截面比.",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":110,"analysis":34},1024545,"高压送电线路最常用的绝缘子类型为（",[322,324,326,328],{"key":20,"text":323,"correct":22},"悬式瓷绝缘子（XPXX）；",{"key":24,"text":325,"correct":22},"悬式玻璃绝缘子（LXPXX）；",{"key":27,"text":327,"correct":22},"合成绝缘子；",{"key":31,"text":329,"correct":29},"针式绝缘子。",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":110,"analysis":34},1024548,"送电线路最常用的耐张线夹为（）。",[334,336,338,340],{"key":20,"text":335,"correct":22},"螺栓耐张线夹；",{"key":24,"text":337,"correct":22},"楔型耐张线夹；",{"key":27,"text":339,"correct":22},"压接式耐张线夹；",{"key":31,"text":341,"correct":29},"并沟线夹。",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":47,"analysis":34},1024552,"作用于杆塔上的荷载按其性质可以分为（）。",[346,348,350,352],{"key":20,"text":347,"correct":29},"经常荷载；",{"key":24,"text":349,"correct":22},"可变荷载；",{"key":27,"text":351,"correct":22},"偶然荷载；",{"key":31,"text":353,"correct":22},"永久荷载。",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":97,"analysis":34},1024557,"各类杆塔在设计时，应计算以下（）。",[358,360,362,364],{"key":20,"text":359,"correct":22},"正常运行情况；",{"key":24,"text":361,"correct":29},"事故情况；",{"key":27,"text":363,"correct":22},"安装情况；",{"key":31,"text":365,"correct":22},"断线情况。",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":110,"analysis":34},1024561,"各类杆塔的正常运行情况的荷载组合为（）。",[370,372,374,376],{"key":20,"text":371,"correct":22},"最大覆冰，相应风速及气温，无断线；",{"key":24,"text":373,"correct":22},"最大风速，无冰，无断线；",{"key":27,"text":375,"correct":22},"最低气温，无冰，无风，无断线（转角及终端杆塔）；",{"key":31,"text":377,"correct":29},"年平均气温，无冰，无风，无断线。",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":110,"analysis":34},1024565,"导地线在档中的接头是强度弱点和事故多发点，因此规程要求重要跨越档不准接头，下列（）情况不漼接头。",[382,384,386,388],{"key":20,"text":383,"correct":22},"标准轨铁路；",{"key":24,"text":385,"correct":22},"高速及一级公路；",{"key":27,"text":387,"correct":22},"110kV及以上电力线路；",{"key":31,"text":389,"correct":29},"—、二级弱电线路。",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":47,"analysis":34},1024570,"直线塔一侧断导线后，由于悬垂绝缘子串偏移，其邻档弧垂显著增大，将导致对重要跨越距离不够，因此规程规定对重要跨越应验算邻档断线时对被跨越物满足规定距离，请指出以下（）情况需验算。",[394,396,397,399],{"key":20,"text":395,"correct":29},"110kV及以上电力线；",{"key":24,"text":385,"correct":22},{"key":27,"text":398,"correct":22},"一级通信线；",{"key":31,"text":400,"correct":22},"标准轨铁路。",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":110,"analysis":34},1024573,"送电线路在运行中，由于雷电、污秽及老化等，时有绝缘子断串发生，因此规程对重要跨越要求悬垂绝缘子用双联串或两个单串，请指出双联串运用于以下（）跨越。",[405,407,409,410],{"key":20,"text":406,"correct":22},"220kV及以上线路；",{"key":24,"text":408,"correct":22},"铁路；",{"key":27,"text":385,"correct":22},{"key":31,"text":411,"correct":29},"通航河流。",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":110,"analysis":34},1024577,"电线常用的防振措施有（）。",[416,418,420,422],{"key":20,"text":417,"correct":22},"降低平均运行应力；",{"key":24,"text":419,"correct":22},"加装防振锤；",{"key":27,"text":421,"correct":22},"加装护线条；",{"key":31,"text":423,"correct":29},"自阻尼电线。",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":97,"analysis":34},1024580,"送电线路对临近电信线路可能产生危险影响的故瘅状态，应考虑下列（）情况。",[428,430,432,434],{"key":20,"text":429,"correct":22},"三相对称中性点直接接地系统的送电线路一相接地短路；",{"key":24,"text":431,"correct":29},"三相对称中性点直接接地系统的送电线路两相接地短路；",{"key":27,"text":433,"correct":22},"三相对称中性点不直接接地系统的送电线路一相接地短路；",{"key":31,"text":435,"correct":22},"三相对称中性点不直接接地系统的送电线路两相在不同地点同时接地短路。",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":84,"analysis":34},1024585,"音频双线电话回路噪声计电动势允许值符合下列（）规定。",[440,442,444,446],{"key":20,"text":441,"correct":29},"兼作电话用有线广播双线回路噪声计电动势允许值应为7mV；",{"key":24,"text":443,"correct":29},"业务电话回路为1OmV；",{"key":27,"text":445,"correct":22},"县电话局至县及以上电话局的电话回路为4.5mV；",{"key":31,"text":447,"correct":22},"县及以下电话局的电话回路为10mV。",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":460,"analysis":34},1024588,"危险影响计算应符合（）规定。",[452,454,456,458],{"key":20,"text":453,"correct":22},"送电线路对地下电信电缆线路同时产生感性耦合和阻性耦合两种影响时，应按两者平方和的平方根计算合成影响；",{"key":24,"text":455,"correct":29},"对电气化铁道的铁路信号线路宜考虑危险影响；",{"key":27,"text":457,"correct":29},"送电线路对地下电信电缆线路应考虑地电流影响，并应按中性点不直接接地的送电线路发生一相接地短路故障时，流入或流出电力设备接地装置的短路电流计算；",{"key":31,"text":459,"correct":22},"带有避雷线的送电线路，可考虑避雷线的返回电流效应来计算避雷线的屏蔽系数。","AD",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":110,"analysis":34},1024591,"干扰影响计算应符合（）规定。",[465,467,469,471],{"key":20,"text":466,"correct":22},"在进行干扰影响计算时，应计入电信线传播效应的衰减系数；",{"key":24,"text":468,"correct":22},"当有展蔽体时，应计入屏蔽体800Hz的屏蔽系数；",{"key":27,"text":470,"correct":22},"对兼作电话用的有线广播双线回路宜按音频双线电话回路计算干扰影响；",{"key":31,"text":472,"correct":29},"当有屏蔽体时，应计入屏蔽体50Hz的屏蔽系数。",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":485,"analysis":34},1024596,"—般情况下，中性点直接接地系统的送电线路对音频双线电话回路的干扰影响，可利用简化公式只计算不平衡影响的噪声计电动势分量，下列（）分量是正确的。",[477,479,481,483],{"key":20,"text":478,"correct":29},"送电线路电压平衡分量感应引起的平衡影响噪声计电动势分量；",{"key":24,"text":480,"correct":22},"送电线路电流平衡分量感应引起的不平衡影响噪声计电动势分量；",{"key":27,"text":482,"correct":22},"送电线路电流剩余分量感应引起的不平衡影响噪声计电动势分量；",{"key":31,"text":484,"correct":29},"送电线路电流平衡分量感应引起的平衡影响噪声计电动势分量。","BC",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":110,"analysis":34},1024599,"送电线路对电信线路的磁危险影响计算应符合（）规定。",[490,492,494,496],{"key":20,"text":491,"correct":22},"在中性点直接接地系统中，应按送电线路发生单相接地短路故障计算；",{"key":24,"text":493,"correct":22},"在中性点不直接接地系统中，对长途电信电缆线路应按送电线路两相不同地点同时发生接地故障计算；",{"key":27,"text":495,"correct":22},"在中性点不直接接地系统中，除长途电信电缆外，对其他电信线路不考虑此項影响；",{"key":31,"text":497,"correct":29},"在中性点不直接接地系统中，对各类电信线路，均不作危险影响计算。",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":160,"analysis":34},1024602,"当有多条送电线路与电信线触近时，其危险影响计算应符合（）规定。",[502,504,506,508],{"key":20,"text":503,"correct":29},"只考虑故障送电线路短路电流的影响；",{"key":24,"text":505,"correct":22},"除考虑故障送电线路短路电流影响外，宜同时考虑邻近的非故障送电线分布电流的影响；",{"key":27,"text":507,"correct":29},"各条邻近线故障分布电流按平方和平方根计算；",{"key":31,"text":509,"correct":22},"对各条邻近线故障分布电流的影吻应考虑电流方向分别计算。",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":33,"analysis":34},1024607,"送电线路对地下电信电缆线路的危险影响计算应符合（）规定。",[514,516,518,520],{"key":20,"text":515,"correct":22},"考虑地电流影响，并按中性点直接接地的送电线路发生单相接地短路故障时，流入或流出搶电线路种塔接地装置的短路电流计算；",{"key":24,"text":517,"correct":22},"当同时产生感性耦合和阻性耗合两种影响时，按两者平方和的平方根计算合成影响；",{"key":27,"text":519,"correct":29},"不考虑地电流影响；",{"key":31,"text":521,"correct":29},"地电流应为故障点的总零序电流。",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":123,"analysis":34},1024611,"中性点不直接接地系统的送电线路的干扰影响计算应符合（）规定.",[526,528,530,532],{"key":20,"text":527,"correct":22},"对音頻双线电话的千扰影响按送电线路单相接地短路故障状态计算，同时应考處送电线路基波和谐波电压的感应影响；",{"key":24,"text":529,"correct":22},"对线一地电报回路的干扰影响按送电线路单相接地短路故障状态计算，应考虑基波电压的感应影响；",{"key":27,"text":531,"correct":29},"对受多条送电线干扰影响的电信线应按平方和的平方根计算合成千扰影响；",{"key":31,"text":533,"correct":22},"不考虑多条送电线路的合成干扰影响。",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":123,"analysis":34},1024615,"我国目前对电力发展规划划分为三个设计阶段，以下说法正确的是（）。",[538,540,542,544],{"key":20,"text":539,"correct":22},"五年规划，中期规划（5~15年），长期规划（15年以上）；",{"key":24,"text":541,"correct":22},"五年规划，中期规划，长期规划；",{"key":27,"text":543,"correct":29},"五年规划，十年规划，十五年規划；",{"key":31,"text":545,"correct":22},"近期规划，中期规划，长远规划。",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":47,"analysis":34},1024619,"电力系统规划设计推荐的方案，应满足的要求是（）。",[550,552,554,556],{"key":20,"text":551,"correct":29},"充裕性；",{"key":24,"text":553,"correct":22},"经济性；",{"key":27,"text":555,"correct":22},"可靠性；",{"key":31,"text":557,"correct":22},"灵活性。",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":460,"analysis":34},1024623,"电力负荷按物理性能分类是（）。",[562,564,566,568],{"key":20,"text":563,"correct":22},"有功负荷；",{"key":24,"text":565,"correct":29},"机械负荷；",{"key":27,"text":567,"correct":29},"电炉负荷；",{"key":31,"text":569,"correct":22},"无功负荷，",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":27,"analysis":34},1024627,"负荷根据对供电可靠性的要求及中断供电所造成的损失程度可分为（）。",[574,576,578,580],{"key":20,"text":575,"correct":29},"一级负荷；",{"key":24,"text":577,"correct":29},"二级负荷；",{"key":27,"text":579,"correct":22},"三级负荷；",{"key":31,"text":581,"correct":29},"四级负荷。",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":110,"analysis":34},1024631,"电力平衡的目的主要是满足规划期电力需求预測的需要，主要确定以下（）的内容。",[586,588,590,592],{"key":20,"text":587,"correct":22},"确定电力系统需要的发电设备总容量；",{"key":24,"text":589,"correct":22},"确定规划期内逐年新增的发电趴容量和退役机组容量；",{"key":27,"text":591,"correct":22},"确定电力系统备用容量在水、火电厂之间的合理分配；",{"key":31,"text":593,"correct":29},"确定电力系统需要的受阻容量。",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":97,"analysis":34},1024635,"确定电力系统电源布局和电源结构的主要原则是（）。",[598,600,602,604],{"key":20,"text":599,"correct":22},"能保证发电能源的稳定供应、能源流向合理，系统安全可靠、经济合理；",{"key":24,"text":601,"correct":29},"发电趴容量和水电电量得到充分利用，满足系统负荷要求；",{"key":27,"text":603,"correct":22},"保护生态，节约能源，减少污染；",{"key":31,"text":605,"correct":22},"规划地区有电厂建设条件。",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":97,"analysis":34},1024638,"核电站具有燃料运输量小、减轻交通运输和环境保护压力的优势，但用水量大和安全可靠性要求较高，因此其站址选择要尽量做到的是（）。",[610,612,614,616],{"key":20,"text":611,"correct":22},"要靠近电力负荷中心；",{"key":24,"text":613,"correct":29},"宜选在人口密度较高地区、离城镇的距离应近一些；",{"key":27,"text":615,"correct":22},"要靠近大江、大河或沿海；",{"key":31,"text":617,"correct":22},"工程地质、地震和防洪等应符合国家要求。",{"id":619,"libraryId":5,"type":15,"typeLabel":16,"stem":620,"options":621,"answer":123,"analysis":34},1024642,"核电站可布局在以下（ ）地区。",[622,624,626,628],{"key":20,"text":623,"correct":22},"发电能源资源缺乏地区；",{"key":24,"text":625,"correct":22},"交通运输紧张地区；",{"key":27,"text":627,"correct":29},"距城镇较近和人口密集地区；",{"key":31,"text":629,"correct":22},"经济比较发达和电力负荷中心地区。",[631,635,638,641,644,647],{"id":632,"name":633,"category":7,"favorite":634},1,"领导干部任职前廉政法规知识测试题",92,{"id":636,"name":637,"category":7,"favorite":632},595,"建筑结构与设备",{"id":639,"name":640,"category":7,"favorite":632},715,"招标采购专业知识与法律法规",{"id":642,"name":643,"category":7,"favorite":632},848,"市政方向-通用基础",{"id":645,"name":646,"category":7,"favorite":8},534,"BIM工程师",{"id":648,"name":646,"category":7,"favorite":8},535]