[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-50":3},{"library":4,"page":9,"limit":9,"total":10,"questions":11,"related":628},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,50,2670,[12,34,47,60,73,86,99,111,123,135,147,159,171,183,196,208,221,233,245,257,270,282,294,306,318,330,342,354,366,378,390,402,414,424,436,448,460,472,484,496,508,520,532,544,556,568,580,592,604,616],{"id":13,"libraryId":5,"type":14,"typeLabel":15,"stem":16,"options":17,"answer":32,"analysis":33},1024289,2,"多选题","水电厂厂用电变串器容量选择的具体要求是（）。",[18,22,25,28],{"key":19,"text":20,"correct":21},"A","两台互为备用时，每台的额定容量应满足所有I、II类负荷或短时厂用电最大负荷；",true,{"key":23,"text":24,"correct":21},"B","三台互为备用或其中一台为明备用时，每台的额定容量宜为厂用电最大负荷的50%~60%；",{"key":26,"text":27,"correct":21},"C","三台以上时，按接线的运行方式及所连接的负荷分析确定；",{"key":29,"text":30,"correct":31},"D","择迫风冷时厂用电变压器的榆出容量作为額定容量.",false,"ABC","",{"id":35,"libraryId":5,"type":14,"typeLabel":15,"stem":36,"options":37,"answer":46,"analysis":33},1024292,"水电厂厂用电最大负荷的计算原则是（）.",[38,40,42,44],{"key":19,"text":39,"correct":21},"经常连续及经常短时运行的负荷；",{"key":23,"text":41,"correct":21},"经常断续运行资荷应考虑同时率；",{"key":26,"text":43,"correct":31},"同一电源供电的互为备用的电动机均应计入；",{"key":29,"text":45,"correct":21},"不经常断续运行的负荷，仅在机组检修时考虑。","ABD",{"id":48,"libraryId":5,"type":14,"typeLabel":15,"stem":49,"options":50,"answer":59,"analysis":33},1024313,"经过技术经济比较论证，水电厂如需设柴油发电机组作应急电源，应考虑的负荷有(）。",[51,53,55,57],{"key":19,"text":52,"correct":31},"电厂生活用电、地区用电；",{"key":23,"text":54,"correct":21},"启动机组、渗漏排水泵；",{"key":26,"text":56,"correct":21},"亊故照明、消防用电；",{"key":29,"text":58,"correct":21},"自控、远动及电子计算机。","BCD",{"id":61,"libraryId":5,"type":14,"typeLabel":15,"stem":62,"options":63,"answer":72,"analysis":33},1024316,"接于水电厂发电机电压母线上的厂用电变压器，调压方式选择正确的有（）。",[64,66,68,70],{"key":19,"text":65,"correct":31},"发电机电压母线电压波动不超过±5%,宜选用带负荷调压变压器；",{"key":23,"text":67,"correct":21},"发电机电压母线电压波动不超过±5%，宜选用无励磁调压变压器；",{"key":26,"text":69,"correct":31},"由系统倒送供厂用电时，经验算电压偏差值如超过容许值，选用无励磁调压变压器；",{"key":29,"text":71,"correct":21},"由系统倒送供厂用电时，经验算电压偏差值如蟑过容许值，选用带负荷调压变压器。","BD",{"id":74,"libraryId":5,"type":14,"typeLabel":15,"stem":75,"options":76,"answer":85,"analysis":33},1024319,"水电厂厂用电变压器阻抗选择，说法正确的是（）。",[77,79,81,83],{"key":19,"text":78,"correct":21},"高压厂用电变压器应选用与普通变压器相同的阻抗值；",{"key":23,"text":80,"correct":31},"低压厂用电变压器应选用与普通变压器相同的阻抗值；",{"key":26,"text":82,"correct":21},"低压厂用电变压器宜选用与普通变压器相同的阻抗值；",{"key":29,"text":84,"correct":21},"引自大机组机端或大容量低压厂用电变压器是否用高阻抗值，应进行比较论证。","ACD",{"id":87,"libraryId":5,"type":14,"typeLabel":15,"stem":88,"options":89,"answer":98,"analysis":33},1024322,"水电厂电动机正常启动需要验算电压水平的是（）。 A.除水电厂过坝设施用的以外的高压电动机；",[90,92,94,96],{"key":19,"text":91,"correct":31},"低压电动机的功率（kW)小于电源变压器容量（kV",{"key":23,"text":93,"correct":31},"的20外时，所连接的母线电压；",{"key":26,"text":95,"correct":21},"配电支线较长的低压电动机的端子电压降；",{"key":29,"text":97,"correct":21},"水电厂过坝设旅用的高压电动机。","CD",{"id":100,"libraryId":5,"type":14,"typeLabel":15,"stem":101,"options":102,"answer":85,"analysis":33},1024324,"水电厂厂用电动机型式选择，说法正确的是（）?",[103,105,107,109],{"key":19,"text":104,"correct":21},"水轮机室、蜗壳层、闸门室、坝内廊道等处，外壳防护等级宜达到IP44级要求；",{"key":23,"text":106,"correct":31},"湿热带和屋外等处外壳坊护等级与上相同；",{"key":26,"text":108,"correct":21},"其他一般场所，外壳防护等级不低于IP23级；",{"key":29,"text":110,"correct":21},"有爆炸危险的场所应采用防爆型电动机。",{"id":112,"libraryId":5,"type":14,"typeLabel":15,"stem":113,"options":114,"answer":46,"analysis":33},1024327,"低压电器和导体的动、热稳定校验，说法正确的是（）",[115,117,119,121],{"key":19,"text":116,"correct":21},"用眼流熔断器保护的可不校验动、热稳定；",{"key":23,"text":118,"correct":21},"用60A以下的熔断器保护的可不校猃动、热稳定；",{"key":26,"text":120,"correct":31},"满足额定短路分断能力的断路器要校验动、热稳定；",{"key":29,"text":122,"correct":21},"采用保护式磁力启动器，可不校验动、热稳定。",{"id":124,"libraryId":5,"type":14,"typeLabel":15,"stem":125,"options":126,"answer":46,"analysis":33},1024329,"高、低压厂用电系统中，电缆截面选择，一般要校验（）。",[127,129,131,133],{"key":19,"text":128,"correct":21},"长期允许工作电流；",{"key":23,"text":130,"correct":21},"电压损失；",{"key":26,"text":132,"correct":31},"经济电流密度；",{"key":29,"text":134,"correct":21},"短路时热稳定。",{"id":136,"libraryId":5,"type":14,"typeLabel":15,"stem":137,"options":138,"answer":32,"analysis":33},1024332,"厂用电器设备布置，说法正确的是（）。",[139,141,143,145],{"key":19,"text":140,"correct":21},"干式变压器可不设单独小间；",{"key":23,"text":142,"correct":21},"油漫式变压溶应设单独小间；",{"key":26,"text":144,"correct":21},"潮湿场地的配电屏宜布置在单独房间内；",{"key":29,"text":146,"correct":31},"大型水电厂的高、低压配电装置可集中布置在同一室内。",{"id":148,"libraryId":5,"type":14,"typeLabel":15,"stem":149,"options":150,"answer":85,"analysis":33},1024335,"火力发电厂髙压厂用电系统的接地方式选择，以下各项正确的有（)。",[151,153,155,157],{"key":19,"text":152,"correct":21},"当接地电容电流小于等于7A时，中性点采用高电阻接地方式；",{"key":23,"text":154,"correct":31},"当接地电容电流小于等于7A时，中性点采用低电阻接地方式；",{"key":26,"text":156,"correct":21},"当接地电容电流大于7A时，中性点采用低电电阻接地方式；",{"key":29,"text":158,"correct":21},"采用不接地方式。",{"id":160,"libraryId":5,"type":14,"typeLabel":15,"stem":161,"options":162,"answer":72,"analysis":33},1024338,"火力发电厂主厂房内的380V低压厂用电系统接地方式，选项中正确的有（）。",[163,165,167,169],{"key":19,"text":164,"correct":31},"采用中性点不接地；",{"key":23,"text":166,"correct":21},"釆用三相三线制，中性点经高电阻接地；",{"key":26,"text":168,"correct":31},"采用三相三线制，中性点经低电阻接地；",{"key":29,"text":170,"correct":21},"采用动力与照明共用的三相四线制中性线直接接地。",{"id":172,"libraryId":5,"type":14,"typeLabel":15,"stem":173,"options":174,"answer":72,"analysis":33},1024341,"220~500kV变电所所用电引接配置，下列选项正确的有（）.",[175,177,179,181],{"key":19,"text":176,"correct":31},"330~500kV变电所，当有2台主变压器时，应从主变压器低庄侧各引1台所用变压器，变压器容量应至少考虑2台主变压器冷却用负荷；",{"key":23,"text":178,"correct":21},"220kV变电所，当有2台主变压器时，应从主变压器低压例分别接2台容量相同可互为备用的所用变压器，每台工作变压器的容量按全所计算负荷选择；",{"key":26,"text":180,"correct":31},"220kV变电所，当只有1台主变压器时，应选2台容量相同所用变压器，均接于1号主变压器低压侧；",{"key":29,"text":182,"correct":21},"220kV变电所，当只有1台主变压器时，2台所用变压器其中1台宜从所外电源引接。",{"id":184,"libraryId":5,"type":14,"typeLabel":15,"stem":185,"options":186,"answer":195,"analysis":33},1024344,"火力发电厂当主厂房低压厂用电系统采用三相三线制时，主厂房照明供电，下述正确的是（）。",[187,189,191,193],{"key":19,"text":188,"correct":21},"容量为200MW及以上机組，每个单元设1台照明变压器，接于机组6kV母线，二次侧为380V\u002F220V中性点直接接地，照明母线采用单母线接线。2台机组的照明变压器互为备用；",{"key":23,"text":190,"correct":31},"照明变压器分散设置，引接于机组6kV母线，二次侧采用380V\u002F220V中性点直接接地；",{"key":26,"text":192,"correct":21},"每台机组设1台照明变压器二次侧为380V\u002F220V中性点直接接地，照明变压器引接于380V母线；",{"key":29,"text":194,"correct":31},"每台机组设1台工作照明变压器，再设1台作备用照明变压器。","AC",{"id":197,"libraryId":5,"type":14,"typeLabel":15,"stem":198,"options":199,"answer":85,"analysis":33},1024347,"火力发电厂高压厂用工作电源引接方式，下述正确的有（）。",[200,202,204,206],{"key":19,"text":201,"correct":21},"当有发电机电压号线时，高压厂用工作电源由各母线段引接、供给接在该軟母线上的机组厂用负荷；",{"key":23,"text":203,"correct":31},"当有发电机电压母线时，高压厂用工作电源由发电机出口引接，供给该机组的厂用负荷；",{"key":26,"text":205,"correct":21},"当发电机与主变压器线路成单元连接时，由主变压器低压側引接，供给该机_的厂用负荷；",{"key":29,"text":207,"correct":21},"当发电机与主变压器线路成发变线组接线时，高压厂用电源可由发电机出口引接。",{"id":209,"libraryId":5,"type":14,"typeLabel":15,"stem":210,"options":211,"answer":220,"analysis":33},1024350,"火力发电厂低压厂用工作电源引接方式，下述正确的有（)?",[212,214,216,218],{"key":19,"text":213,"correct":31},"按炉分段的低压厂用母线，其工作变压器可由任何高压厂用母线供电；",{"key":23,"text":215,"correct":21},"按炉分段的低压厂用母线，其工作变压器应由对应的高压厂用母线供电；",{"key":26,"text":217,"correct":21},"当200MW发电机与主变压器为单元接线时，低压厂用电源可从高压厂用变压器低压侧的母线引接；",{"key":29,"text":219,"correct":31},"当有高压厂用母线段时，由发电机出口引接。","BC",{"id":222,"libraryId":5,"type":14,"typeLabel":15,"stem":223,"options":224,"answer":59,"analysis":33},1024353,"火力发电厂600MW机组的高压厂用工作电源，不考虑脱硫负荷，可供选择的方案是（）。",[225,227,229,231],{"key":19,"text":226,"correct":31},"采用3台双绕组变压器供电；",{"key":23,"text":228,"correct":21},"采用2台分裂变压器供电；",{"key":26,"text":230,"correct":21},"采用2台双绕组变压器供电；",{"key":29,"text":232,"correct":21},"采用1台分裂变压器。",{"id":234,"libraryId":5,"type":14,"typeLabel":15,"stem":235,"options":236,"answer":98,"analysis":33},1024355,"火力发电厂主厂房低压电动机的供电方式的叙述中，下述有错的是（）。",[237,239,241,243],{"key":19,"text":238,"correct":31},"主厂房低压电动机可采用明备用动力中心和电动机控制中心的供电方式，也可采用暗备用动力中心和电动机控制中心的供电方式；",{"key":23,"text":240,"correct":31},"对暗备用的动力中心和控制中心，都应成对设置；",{"key":26,"text":242,"correct":21},"C对晴备用的动力中心，电动机控制中心由对应的动力中心单电源供电，但I类电动机应由动力中心供电；",{"key":29,"text":244,"correct":21},"对明备用的动力中心，接有II类负荷的电动机控制中心应双电源供电，75kW及以下的电动机应由电动机控制中心供电。",{"id":246,"libraryId":5,"type":14,"typeLabel":15,"stem":247,"options":248,"answer":85,"analysis":33},1024358,"220~500kV变电所所用电接线方式下述正确的是（），",[249,251,253,255],{"key":19,"text":250,"correct":21},"所用低压系统应采用三相四线制，系统的中性点直接接地，系统额定电压采用380V\u002F220V,动力和照明共用供电；",{"key":23,"text":252,"correct":31},"所用低压系统采用三相三线制，系统的中性点经高电阻接地，系统额定电压采用380V供动力负荷，另设.1台380V\u002F220V照明变压器；",{"key":26,"text":254,"correct":21},"所用电母线采用按工作变压器划分的单母线接线方式，相邻两狹工作母线间可设分段或联络断路器，但宜同时供电分列运行且两段母线间不宜设自动投入装置；",{"key":29,"text":256,"correct":21},"当任一台工作变压器退出时，设有专用的备用变压器应自动切换至失电的工作母线段继续供电。",{"id":258,"libraryId":5,"type":14,"typeLabel":15,"stem":259,"options":260,"answer":269,"analysis":33},1024361,"火力发电厂中，在厂用电系统交流保安电源设置的叙述中，正确的是()。",[261,263,265,267],{"key":19,"text":262,"correct":21},"200MW及以上的机组应设交流保安电源；",{"key":23,"text":264,"correct":21},"交流保安电源宜采用自动快速启动的柴油发电机组}",{"key":26,"text":266,"correct":31},"正常运行时，保安段应经1回线路由本机组低压动力中心供电；",{"key":29,"text":268,"correct":31},"若机组低压工作变压器为10OOkVA,柴油发电机为500kW；厂用电采用高电阻接地方式，变压器中性点接地电阻为500,柴油发电机中性点接地电阻可用25Ω。","AB",{"id":271,"libraryId":5,"type":14,"typeLabel":15,"stem":272,"options":273,"answer":85,"analysis":33},1024364,"火力发电厂交流保安电源设置的主要原则，正确的是（）。",[274,276,278,280],{"key":19,"text":275,"correct":21},"宜用自动快速启动的柴油发电机组，按允许加负荷的程序，分批投入保安负荷》",{"key":23,"text":277,"correct":31},"交流保安电源的电压和中性点接地方式可不与低压厂用电系统一致；",{"key":26,"text":279,"correct":21},"每两台200MW机组宜设里一台柴油发电机组，每台300MW或600MW机组立设置一台柴油发电机组；",{"key":29,"text":281,"correct":21},"正常运行的保安母线段应由本机组的低压或暗备用PC供电，当确认本机组PC真正失电后应能切换到交流保安电源供电。",{"id":283,"libraryId":5,"type":14,"typeLabel":15,"stem":284,"options":285,"answer":85,"analysis":33},1024367,"水力发电厂厂用电源设计必须满足的基本要求是（）。",[286,288,290,292],{"key":19,"text":287,"correct":21},"各种运行方式下的厂用电负荷需要，并保证供电；",{"key":23,"text":289,"correct":31},"设置亊故柴油发电机组；",{"key":26,"text":291,"correct":21},"电源相对独立；",{"key":29,"text":293,"correct":21},"当一个电源故障时，另一电源应能自动或远方操作切换投入。",{"id":295,"libraryId":5,"type":14,"typeLabel":15,"stem":296,"options":297,"answer":32,"analysis":33},1024370,"水电厂的外引电源可通过（ ）方式取得。",[298,300,302,304],{"key":19,"text":299,"correct":21},"高压联络自耦变压器的第三绕组；",{"key":23,"text":301,"correct":21},"主变压器倒送；",{"key":26,"text":303,"correct":21},"电厂的高压侧母线引接；",{"key":29,"text":305,"correct":31},"独立的地区电网。",{"id":307,"libraryId":5,"type":14,"typeLabel":15,"stem":308,"options":309,"answer":85,"analysis":33},1024373,"水电厂厂用变压器型式选择，下列描述正确的是（）。",[310,312,314,316],{"key":19,"text":311,"correct":21},"布置在厂房内的厂用变压器应采用干式变压器；",{"key":23,"text":313,"correct":31},"与离相封闭母线分支连接时，宜采用三相干式变压器；",{"key":26,"text":315,"correct":21},"安装在潮湿地点时，应选用防潮性能良好的干式变压器；",{"key":29,"text":317,"correct":21},"低压厂用变压器接线组別宜选用Dynll。",{"id":319,"libraryId":5,"type":14,"typeLabel":15,"stem":320,"options":321,"answer":59,"analysis":33},1024376,"水电厂最大负荷计算原则，下列描述正确的是（）。",[322,324,326,328],{"key":19,"text":323,"correct":31},"经常连续及不经常连续运行的负荷均应计算；",{"key":23,"text":325,"correct":21},"经常断续运行负荷应考虑同时率后计入；",{"key":26,"text":327,"correct":21},"互为备用的电动机，只计算参加运行的部分；当由不同变压器供电时，应分别计入；",{"key":29,"text":329,"correct":21},"不经常连续及不经常短时运行的负荷应按设备组合运行情况计算，但不计入仅在亊故情况下运行的负荷。",{"id":331,"libraryId":5,"type":14,"typeLabel":15,"stem":332,"options":333,"answer":85,"analysis":33},1024378,"水电厂厂用电系统电器设备和导体选择原则，下列描述正确的是（）。",[334,336,338,340],{"key":19,"text":335,"correct":21},"高压厂用电系统电源回路电力电缆应采用铜芯；",{"key":23,"text":337,"correct":31},"高压厂用电系统的导体截面按经济电流密度选择；",{"key":26,"text":339,"correct":21},"高压厂用断路器开断能力可不考虑短路电流非周期分量对断路器分断能力的影响；",{"key":29,"text":341,"correct":21},"校验容量为315kVA及以下的变压器供电的主配电屏的分断能力时，可不计及电动机的反馈电流。",{"id":343,"libraryId":5,"type":14,"typeLabel":15,"stem":344,"options":345,"answer":32,"analysis":33},1024381,"水电厂厂用电系统设计时，对电动机回路在（）情况下，应校验电缆的电压损失。",[346,348,350,352],{"key":19,"text":347,"correct":21},"P 20kW,L 60m；",{"key":23,"text":349,"correct":21},"25kW≤P≤50kW,L 100m,",{"key":26,"text":351,"correct":21},"50kW≤P≤100kW,L 150m；",{"key":29,"text":353,"correct":31},"P〉100kW，L 200m。",{"id":355,"libraryId":5,"type":14,"typeLabel":15,"stem":356,"options":357,"answer":32,"analysis":33},1024384,"水电厂高压厂用电电压主要根据（）综合比较确定，",[358,360,362,364],{"key":19,"text":359,"correct":21},"发电机电压；",{"key":23,"text":361,"correct":21},"厂用电动机电压；",{"key":26,"text":363,"correct":21},"地区电源电压；",{"key":29,"text":365,"correct":31},"负荷大小。",{"id":367,"libraryId":5,"type":14,"typeLabel":15,"stem":368,"options":369,"answer":72,"analysis":33},1024387,"水电厂机组厂用电负荷中，属于I类负荷的是（）。",[370,372,374,376],{"key":19,"text":371,"correct":31},"隔离开关操动机构电源；",{"key":23,"text":373,"correct":21},"主变压器冷却电源；",{"key":26,"text":375,"correct":31},"机组盘车电源；",{"key":29,"text":377,"correct":21},"机组起助电源。",{"id":379,"libraryId":5,"type":14,"typeLabel":15,"stem":380,"options":381,"answer":59,"analysis":33},1024389,"火力发电厂高压用电系统，关于短路电流非周期分量对断路器开断电流的影响，下述正确的是（）。",[382,384,386,388],{"key":19,"text":383,"correct":31},"当主保护动作时间与断路器固有分闸时间之和大于0.15s时，应计及非周期分量影响；",{"key":23,"text":385,"correct":21},"B当主保护动作时间与断路器固有分闸时间之和小于0.11s时，应计及非周期分量影响；",{"key":26,"text":387,"correct":21},"当主保护动作时间与断年器固有分闸对间之和为0.11~0.15s,且短路电流周期分量为断路器额定开断电流的90%以上，应计及非周期分量影响；",{"key":29,"text":389,"correct":21},"当主保护动作时间和断路器固有分闸之和大于0.15s时，可不计及非周期分量影响。",{"id":391,"libraryId":5,"type":14,"typeLabel":15,"stem":392,"options":393,"answer":59,"analysis":33},1024392,"火力发电厂为了保证I类电动机的自启动，应对成组电动机自启动时的厂用母线电压进行校验，并不低于以下规定，自启动要求的最低母线电压为（，）。",[394,396,398,400],{"key":19,"text":395,"correct":31},"高压厂用母线75%~80%；",{"key":23,"text":397,"correct":21},"高压厂用母线65%~70%；",{"key":26,"text":399,"correct":21},"低压厂用母线，单独自启.动60%；",{"key":29,"text":401,"correct":21},"低压厂用母线，低压母线与高压母线串接自启动55%。",{"id":403,"libraryId":5,"type":14,"typeLabel":15,"stem":404,"options":405,"answer":32,"analysis":33},1024395,"火力发电厂装机容量为2X300MW, 6kV厂用电设2段公用段，正常运行由启动\u002F备用变压器供电，2台机组高压工作变压器作备用电源，则启动\u002F备用变压器应考虑自启动方式有()。",[406,408,410,412],{"key":19,"text":407,"correct":21},"空载自启动；",{"key":23,"text":409,"correct":21},"失压自启动；",{"key":26,"text":411,"correct":21},"带负荷自启动；",{"key":29,"text":413,"correct":31},"只考虑空载自启动和带负荷自启动.",{"id":415,"libraryId":5,"type":14,"typeLabel":15,"stem":416,"options":417,"answer":220,"analysis":33},1024398,"火力发电厂高压变压雜应考虑的启动方式有（）。",[418,419,420,422],{"key":19,"text":411,"correct":31},{"key":23,"text":409,"correct":21},{"key":26,"text":421,"correct":21},"最大容量的电动机正常启动；",{"key":29,"text":423,"correct":31},"空载自启动。",{"id":425,"libraryId":5,"type":14,"typeLabel":15,"stem":426,"options":427,"answer":32,"analysis":33},1024401,"火力发电厂髙压厂用变压器或电抗器的阻抗选择,在已满足母线电压偏移的情况下还应考虑的外部因素有（）。",[428,430,432,434],{"key":19,"text":429,"correct":21},"使厂用电系统能采用轻型的电器设备；",{"key":23,"text":431,"correct":21},"满足电动机正常启动和成组自启动时的电压水平；",{"key":26,"text":433,"correct":21},"对电缆热稳定的影响；",{"key":29,"text":435,"correct":31},"对母线及出线导体的动穗定要求。",{"id":437,"libraryId":5,"type":14,"typeLabel":15,"stem":438,"options":439,"answer":220,"analysis":33},1024403,"火力发电厂容量为200MW及以上机组，宜采用的高压厂用设备有()。",[440,442,444,446],{"key":19,"text":441,"correct":31},"少油断路器}",{"key":23,"text":443,"correct":21},"真空断路器；",{"key":26,"text":445,"correct":21},"高压熔断器串真空接触组合设备；",{"key":29,"text":447,"correct":31},"SF6断路器，",{"id":449,"libraryId":5,"type":14,"typeLabel":15,"stem":450,"options":451,"answer":59,"analysis":33},1024406,"火力发电厂高压厂用设备采用髙压熔断器串真空接触器时，其选择应考虑（）。",[452,454,456,458],{"key":19,"text":453,"correct":31},"限流熔断不宜降压使用，也不宜串联使用；",{"key":23,"text":455,"correct":21},"高压熔断器应根据保护设备特性，逸择专用的高压限流器熔断器；",{"key":26,"text":457,"correct":21},"熔断器的額定开断电流应大于回路中最大预期钱路电流用期分量有效值；",{"key":29,"text":459,"correct":21},"真空接触器应能承受和关合眼洗熔断器的切断电流。",{"id":461,"libraryId":5,"type":14,"typeLabel":15,"stem":462,"options":463,"answer":85,"analysis":33},1024408,"火力发电厂高压厂用电案统中性点的确定，以下正确的是（）。",[464,466,468,470],{"key":19,"text":465,"correct":21},"高压厂用工作变压器负载侧的中性点；",{"key":23,"text":467,"correct":31},"由高压厂用电系统供电的一台低压厂用工作变压器髙压侧的中性点；",{"key":26,"text":469,"correct":21},"专用的三相变压器，构成人为的中性点；",{"key":29,"text":471,"correct":21},"由高压厂用电系统供电的两台低压厂用工作变压器髙压例的中性点.",{"id":473,"libraryId":5,"type":14,"typeLabel":15,"stem":474,"options":475,"answer":72,"analysis":33},1024411,"某火力发电厂6kV厂用电系统电缆总对地电容经计算为1.71评，其中性点宜（可）采用（）(单相接地电容电流Ic=√3UcωCX103、ω=2πf)。",[476,478,480,482],{"key":19,"text":477,"correct":31},"低电阻接地方式；",{"key":23,"text":479,"correct":21},"不接地方式；",{"key":26,"text":481,"correct":31},"经消孤线圈、过补楼方式；",{"key":29,"text":483,"correct":21},"高电阻接地方式。",{"id":485,"libraryId":5,"type":14,"typeLabel":15,"stem":486,"options":487,"answer":195,"analysis":33},1024414,"水力发电厂I类负荷，应由两个电源供电，供电方式可（）。",[488,490,492,494],{"key":19,"text":489,"correct":21},"机械上互为备用的I类负荷，应从不同分段的主配电盘或不同分段主配电盘供电的分配电盘分別引出电源供电？",{"key":23,"text":491,"correct":31},"机械上互为备用的I类负荷，应从不同分段的主配电盘分别引出电源供电；",{"key":26,"text":493,"correct":21},"机械上只有一套的I类负荷，应从不同分段的主配电盘或不同分段主配电盘供电的分配电盘分别引出两个电源供电，两个电源经切换操作亙为备用；",{"key":29,"text":495,"correct":31},"机械上互为备用的I类负荷，应从不同分段的主配电盘分別引出电源供电，两个电源经切换操作互为备用。",{"id":497,"libraryId":5,"type":14,"typeLabel":15,"stem":498,"options":499,"answer":85,"analysis":33},1024417,"下述变电所所用电接线要求、备用方式和配置原则的叙述中正确的是（）。",[500,502,504,506],{"key":19,"text":501,"correct":21},"35~110kV变电所，在有两台及以上主变压器的变电所中，宜装设两台容量相同可互为备用的所用变压器；",{"key":23,"text":503,"correct":31},"330~500kV变电所如主变压器为两台（组）及以上时，所用工作变压器不宜少于两台，工作变压器从主变压器高压侧引接，并应装设一台从所外可靠电源引接的专用备用变压器；",{"key":26,"text":505,"correct":21},"220kV变电所两台所用工作变压器低压侧采用单母线分段接线，两台工作变压器平时分列运行；",{"key":29,"text":507,"correct":21},"35~110kV变电所，若有两台所用工作变压器，变压器之间不考虑并列运行。",{"id":509,"libraryId":5,"type":14,"typeLabel":15,"stem":510,"options":511,"answer":220,"analysis":33},1024419,"火力发电厂低压厂用电设备选择中，关于断路器额定短路分断能力校验的叙述，下面正确的是（）?",[512,514,516,518],{"key":19,"text":513,"correct":31},"当利用断路器延时过电流脱扣器作短路保护时，应采用断路器的额定分断能力校验；",{"key":23,"text":515,"correct":21},"另装继电保护、满足額定分断能力的断路器可不校驗动稳定；",{"key":26,"text":517,"correct":21},"断路器的瞬时和短延时脱扣器的整定卷流应按躲开电动机启动电流的条件进行整定，并按最小短路电流校验灵敏系数；",{"key":29,"text":519,"correct":31},"断路器另装继电保护时，保护的动作时间不能超过断路器延时脱扣器的最长延时时间。",{"id":521,"libraryId":5,"type":14,"typeLabel":15,"stem":522,"options":523,"answer":85,"analysis":33},1024422,"水电厂厂用变压器容量选择，应满足（）",[524,526,528,530],{"key":19,"text":525,"correct":21},"各种运行方式下可能的最大负荷；",{"key":23,"text":527,"correct":31},"电动机自启动时，母线电压不低于额定电压的",{"key":26,"text":529,"correct":21},"两台互为备用的变压器，其额定容量应满足所有I、II类负荷或短时满足厂用电最大负荷的需要；",{"key":29,"text":531,"correct":21},"选择变压器容量时，可不计温度修正系数的影响。",{"id":533,"libraryId":5,"type":14,"typeLabel":15,"stem":534,"options":535,"answer":85,"analysis":33},1024425,"水电厂低压厂用电短路电流计算，应考虑()。",[536,538,540,542],{"key":19,"text":537,"correct":21},"应计及电阻，导体的电阻应取額定溫升的电阻值；",{"key":23,"text":539,"correct":31},"采用一级电压供电时，厂用变压器低压側的系统阻抗可忽略不计；",{"key":26,"text":541,"correct":21},"厂用电額定电压为380V时，计算三相短路电流，回路电压取400V；计算单相短路电流时，回路电压取220V；",{"key":29,"text":543,"correct":21},"计算配电盘母线短路电流时，应在第一周期内计及20kW及以上的异步电动机的反馈电流.",{"id":545,"libraryId":5,"type":14,"typeLabel":15,"stem":546,"options":547,"answer":46,"analysis":33},1024428,"火力发电厂厂用电动机选择应考虑的有（）。",[548,550,552,554],{"key":19,"text":549,"correct":21},"厂用电动机宜采用高效、节能的交流电动杌，如新设计的Y系列交流电动机；",{"key":23,"text":551,"correct":21},"厂用电动机宜采用鼠笼式，启动力矩要求大的设备应采用深槽式或双鼠笼式；",{"key":26,"text":553,"correct":31},"对启动力矩要求大的设备采用一般鼠笼式，不采用深槽或双鼠笼式电动机；",{"key":29,"text":555,"correct":21},"在潮湿、多灰尘的车间（如锅炉房、煤场等）外壳防护等级要求达到IP54要求，其他一般场所可采用不低于IP23级，对有防爆危险场所应采用防爆型电动机。",{"id":557,"libraryId":5,"type":14,"typeLabel":15,"stem":558,"options":559,"answer":32,"analysis":33},1024449,"火力发电厂厂用电动机容量需要校验的有（ ）。",[560,562,564,566],{"key":19,"text":561,"correct":21},"对于机械转动惯量大或重载启动的电动机，当使用条件与制造厂配套不符时，应按启动条件校检其容量；",{"key":23,"text":563,"correct":21},"对鼠笼式电动机，应按冷状态启动2次或热状态启动1次进行校验，当定子导体温度超过绝缘允许温度时，应加大电动机容量或与制造厂协商采用其他措施；",{"key":26,"text":565,"correct":21},"当电动机用于1000~4000m的高海拔地区时，应按海拔高度校验电动机容量是否降低；",{"key":29,"text":567,"correct":31},"对鼠笼型电动机可不考虑冷态或热态启动时定子绕组的温升。",{"id":569,"libraryId":5,"type":14,"typeLabel":15,"stem":570,"options":571,"answer":32,"analysis":33},1024451,"火力发电厂厂用配电室对门、窗的要求正确的是()。",[572,574,576,578],{"key":19,"text":573,"correct":21},"配电装置宜采用固定窗，并应采用钢丝乳白（或其他不易破碎能避免阳光直射）玻璃；",{"key":23,"text":575,"correct":21},"对配电装置室门的通风措施（如门上有通风百页）应加装防小动物，防灰的细孔防腐蚀的网格；",{"key":26,"text":577,"correct":21},"厂用配电室的门应为向外开的防火门，并装有内侧不用钥匙可开启的锁，如弹簧锁，相邻配电室之间的门，应能双向开启；",{"key":29,"text":579,"correct":31},"厂用配电室门的宽度应按搬运的最大设备外形尺寸再加200~400mm，且不小于900mm，门高度不低于2100mm；维护门的尺寸不小于800mmX1900mm。",{"id":581,"libraryId":5,"type":14,"typeLabel":15,"stem":582,"options":583,"answer":85,"analysis":33},1024453,"火力发电厂厂用配电装置对通风的要求，下述正确的是（）。",[584,586,588,590],{"key":19,"text":585,"correct":21},"厂用配电装置室、变压器室和电抗器间的通岚应使室温满足设备技术条件的要求；",{"key":23,"text":587,"correct":31},"油浸变压器室的通风系统可以与邻近厂用配电装置室的通风系统合并考虑；",{"key":26,"text":589,"correct":21},"厂用配电装里室应设置亊故排风机，所有进、出风口应有避免灰、水、汽、小动物进入厂用配电装置室的措施；",{"key":29,"text":591,"correct":21},"有多台油浸变压器时变压器室的通风系统不应合并。",{"id":593,"libraryId":5,"type":14,"typeLabel":15,"stem":594,"options":595,"answer":46,"analysis":33},1024456,"照明光源宜采用（）。",[596,598,600,602],{"key":19,"text":597,"correct":21},"荧光灯；",{"key":23,"text":599,"correct":21},"白炽灯；",{"key":26,"text":601,"correct":31},"卤钨灯；",{"key":29,"text":603,"correct":21},"高强气体放电灯。",{"id":605,"libraryId":5,"type":14,"typeLabel":15,"stem":606,"options":607,"answer":32,"analysis":33},1024459,"下列工作场所，照明光源可选用白炽灯的是（）。",[608,610,612,614],{"key":19,"text":609,"correct":21},"需要亊故照明的场所；",{"key":23,"text":611,"correct":21},"需防止电磁波干扰的场所；",{"key":26,"text":613,"correct":21},"因光源频闪影响视觉效果的场所；",{"key":29,"text":615,"correct":31},"照度高，照明时间较长的场所。",{"id":617,"libraryId":5,"type":14,"typeLabel":15,"stem":618,"options":619,"answer":269,"analysis":33},1024462,"下列场所照明光源宜采用高压纳灯的是（）。",[620,622,624,626],{"key":19,"text":621,"correct":21},"道路；",{"key":23,"text":623,"correct":21},"煤场；",{"key":26,"text":625,"correct":31},"办公室；",{"key":29,"text":627,"correct":31},"控制室。",[629,633,636,639,642,645],{"id":630,"name":631,"category":7,"favorite":632},1,"领导干部任职前廉政法规知识测试题",92,{"id":634,"name":635,"category":7,"favorite":630},595,"建筑结构与设备",{"id":637,"name":638,"category":7,"favorite":630},715,"招标采购专业知识与法律法规",{"id":640,"name":641,"category":7,"favorite":630},848,"市政方向-通用基础",{"id":643,"name":644,"category":7,"favorite":8},534,"BIM工程师",{"id":646,"name":644,"category":7,"favorite":8},535]