[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":604},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,5,50,2670,[13,34,46,58,70,82,94,106,118,130,142,152,164,176,188,200,212,224,236,248,260,272,284,296,308,320,332,344,352,364,376,388,400,408,420,432,444,455,467,479,490,502,514,526,538,545,557,569,580,592],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1021950,1,"单选题","某生活区安装一台8OOkVA变压器，高压侧电压为10kV，其保护采用熔断器保护。 此台变压器若仅作生活用电，其熔断器规格应为（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","RN1-10\u002F50,熔管额定电流\u002F熔体額定电流50\u002F50；",false,{"key":24,"text":25,"correct":26},"B","RN1-10\u002F75,熔管额定电流\u002F熔体颏定电流100\u002F75；",true,{"key":28,"text":29,"correct":22},"C","RN1-10\u002F100,熔管額定电流\u002F熔体額定电流100\u002F100；",{"key":31,"text":32,"correct":22},"D","RN1-10\u002F150,熔管額定电流\u002F熔体额定电流150\u002F150。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},1021951,"某生活区安装一台8OOkVA变压器，高压侧电压为10kV，其保护采用熔断器保护。 该变压器若除生活用电外，还接有两台消防水泵，其溶断器规格应为（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"RN1-10\u002F50,1OkV,熔管額定电流\u002F熔体額定电流50\u002F50；",{"key":24,"text":41,"correct":22},"RN1-10\u002F75,1OkV,熔管额定电流\u002F熔体额定电流100\u002F75；",{"key":28,"text":43,"correct":26},"RN1-10\u002F100，1OkV,熔管额定电流\u002F熔体额定电流100\u002F100；",{"key":31,"text":45,"correct":22},"RN1-10\u002F150,1OkV,熔管额定电流\u002F熔体額定电流150\u002F150。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},1021952,"某发电厂发电机装机容量为2x 50MW，功率因数cosψ=0.85，额定电压为10.5kV，接线均为发电机，变压器组接上11OkV升压站，发电机回路和升压变压器绕组及1OkV导体的电容电流为11A。 该两台发电机中性点一般情况下应采用的接地方式为（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"中性点不接地；",{"key":24,"text":53,"correct":22},"中性点直接接地；",{"key":28,"text":55,"correct":26},"中性点经消孤线圈接地（欠补偿方式）；",{"key":31,"text":57,"correct":22},"中性点经消弧线圈接地（过补偿方式）。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1021953,"某发电厂发电机装机容量为2x 50MW，功率因数cosψ=0.85，额定电压为10.5kV，接线均为发电机，变压器组接上11OkV升压站，发电机回路和升压变压器绕组及1OkV导体的电容电流为11A。 两台发电机中性点经消弧线接地，单台消弧线圏的容量应选择（）（脱谐度按小于30%计）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"31~61kVA；",{"key":24,"text":65,"correct":26},"38~76kVA；",{"key":28,"text":67,"correct":22},"61~122kVA；",{"key":31,"text":69,"correct":22},"76~152kVA。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},1021954,"某发电厂发电机装机容量为2x 50MW，功率因数cosψ=0.85，额定电压为10.5kV，接线均为发电机，变压器组接上11OkV升压站，发电机回路和升压变压器绕组及1OkV导体的电容电流为11A。 3~66kV电网采用中性点不接地方式，但当电网架空线路单相接地故障电流最小大于（）又需在接地故障条件下运行时，主变压器中性点应经消弧线圈接地。",[74,76,78,80],{"key":20,"text":75,"correct":22},"40A；",{"key":24,"text":77,"correct":22},"30A；",{"key":28,"text":79,"correct":22},"20A；",{"key":31,"text":81,"correct":26},"10A。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1021955,"在断路器的配置及功能上的叙述中： 一个短路点同时跳两台断路器，该短路点不可能位于（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"一台半断路器接线的进出线；",{"key":24,"text":89,"correct":26},"双母线接线的进出线；",{"key":28,"text":91,"correct":22},"多角形接线的进出线；",{"key":31,"text":93,"correct":22},"外桥接线的出线。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},1021956,"在断路器的配置及功能上的叙述中： 对出线断路器检修时，（）将中断对用户供电。",[98,100,102,104],{"key":20,"text":99,"correct":26},"双母线带分段断路器；",{"key":24,"text":101,"correct":22},"双母线设专用旁路断路器；",{"key":28,"text":103,"correct":22},"分段断路器兼作旁路断路器；",{"key":31,"text":105,"correct":22},"内桥接线（带跨条）。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},1021957,"在断路器的配置及功能上的叙述中： 以下关于断路器的设置的叙述错误的有（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"双母线220kV进出线回路数为10~14回时，在一组母线上用断路器分段；",{"key":24,"text":113,"correct":22},"双母线220kV进出线回路数为15回及以上时，两组母线均用断路器分段；",{"key":28,"text":115,"correct":22},"在220kV双母线分段中，均装设两台母联兼旁路断珞器；",{"key":31,"text":117,"correct":26},"200MW机组高压厂用分支应装设断路器。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1021958,"隔离开关的设置与功能。 下面不作倒闸操作电器使用的隔离开关有（）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"双母线接线的母线隔离开关；",{"key":24,"text":125,"correct":26},"单母线接线的母线隔离开关；",{"key":28,"text":127,"correct":22},"桥形接线的跨条隔离开关；",{"key":31,"text":129,"correct":22},"—台半接线的母线隔离开关。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},1021959,"隔离开关的设置与功能。 关于隔离开关的设置正确的有（）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"330~500kV避雷器和线路电压互感器均应装设隔离开关；",{"key":24,"text":137,"correct":22},"中小型发电机出口一般可不装设隔离开关；",{"key":28,"text":139,"correct":22},"220kV及以下线路避雷器和接在发电机与变压器引出线的避雷器均应装设隔离开关；",{"key":31,"text":141,"correct":26},"在出线装设电抗器的6~10kv配电装置中，当向不同用户供电的两回线共用一台断路器和一组电抗器时，每回线上应各装设一组出线隔离开关。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1021960,"隔离开关的设置与功能。 下面所列隔离开关，仅作检修时隔离电器用的隔离开关有（）。",[146,147,148,150],{"key":20,"text":123,"correct":22},{"key":24,"text":125,"correct":26},{"key":28,"text":149,"correct":22},"断路器两侧的隔离开关；",{"key":31,"text":151,"correct":22},"一台半接线的进出线装设的隔离开关。",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":31,"analysis":33},1021961,"有一中型凝汽式火电厂，装机容量为2X1OOMW+2X55MW，发电机出口电压为10.5kV,发电机电压出线10回，10回的最大综合负荷为80MW,最小为40MW,110kV出线共4回，每回输送容量相同。 对主变压器的选择，正确的是（）。",[156,158,160,162],{"key":20,"text":157,"correct":22},"1台330MVA的双绕组变压器；",{"key":24,"text":159,"correct":22},"2台170MVA的双绕组变压器；",{"key":28,"text":161,"correct":22},"2台200MVA的双绕组变压器；",{"key":31,"text":163,"correct":26},"2台240MVA的双绕组变压器。",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":20,"analysis":33},1021962,"有一中型凝汽式火电厂，装机容量为2X1OOMW+2X55MW，发电机出口电压为10.5kV,发电机电压出线10回，10回的最大综合负荷为80MW,最小为40MW,110kV出线共4回，每回输送容量相同。 100MW发电机出线如选用组合导i，应选择（）。",[168,170,172,174],{"key":20,"text":169,"correct":26},"2XLGJ-800\u002F55+24XLJ-240；",{"key":24,"text":171,"correct":22},"2XLGJ-630\u002F45+16XLJ-185；",{"key":28,"text":173,"correct":22},"2XLGJ-630\u002F45+24XLJ-240；",{"key":31,"text":175,"correct":22},"2XLGJ-500\u002F35+16XLJ-185。",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":24,"analysis":33},1021963,"有一中型凝汽式火电厂，装机容量为2X1OOMW+2X55MW，发电机出口电压为10.5kV,发电机电压出线10回，10回的最大综合负荷为80MW,最小为40MW,110kV出线共4回，每回输送容量相同。 11OkV采用双母线，其母联断路器的额定电流应选择（）。",[180,182,184,186],{"key":20,"text":181,"correct":22},"1000A；",{"key":24,"text":183,"correct":26},"1600A；",{"key":28,"text":185,"correct":22},"2000A；",{"key":31,"text":187,"correct":22},"2500A。",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":20,"analysis":33},1021964,"发电厂主变压器容量及台数选择。 发电机容量60MW及以下，具有发电机电压母线的主变压器容量，不需满足的要求为（）。",[192,194,196,198],{"key":20,"text":193,"correct":26},"具有发电机电压母线的主变压器，其容量应与接在发电机电压母线的发电机容量相匹配；",{"key":24,"text":195,"correct":22},"发电机电压母线的负荷为最小时，能将剩余有功和无功功率送入地区电力系统;",{"key":28,"text":197,"correct":22},"当发电机电压母线上的容量最大的一台发电机停运时，应能从电力系统受电，以满足发电机电压母线最大负荷的需要；",{"key":31,"text":199,"correct":22},"当发电厂为热电厂，因供热机组热负荷的变动而需要限制本厂出力时，应能从电力系统受电，以满足发电机电压母线的最大负荷的需要。",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":24,"analysis":33},1021965,"发电厂主变压器容量及台数选择。 发电机容量为60MW及以下，发电机电压母线与系统的主变压器台数，下面所述不正确的是（）。",[204,206,208,210],{"key":20,"text":205,"correct":22},"发电机电压母线与系统连接的变压器不应少于2台；",{"key":24,"text":207,"correct":26},"发电机电压母线与系统连接的变压器不应少于3台；",{"key":28,"text":209,"correct":22},"对主要向发电机电压供电的地方电厂，而系统电源仅作备用，则允许只装设1台主变压器作为发电厂与系统间的联络；",{"key":31,"text":211,"correct":22},"对小型发电厂，接在发电机电压母线上的主变压器宜设置1台。",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":24,"analysis":33},1021966,"发电厂主变压器容量及台数选择。 发电厂主变压器绕组的数量，下面所述错误的是（）。",[216,218,220,222],{"key":20,"text":217,"correct":22},"最大机组容量为125MW及以下的发电厂以两种升高电压向用户供电或与电力系统连接时，其主变压器宜采用三绕组变压器；",{"key":24,"text":219,"correct":26},"对于机组容量在200MW及以上的发电厂，当有两种升高电压等级时，宜采用三绕组变压器；",{"key":28,"text":221,"correct":22},"机组容量在200MW及以上的发电厂，一般都采用与双绕组变压器组成单元接线；",{"key":31,"text":223,"correct":22},"当机组容量在200MW及以上时，一般都采用与双绕组变压器组成单元接线，而不与三绕组变压器组成单元接线，当发电机具有两种升髙电压等级时，則装设联络变压器。",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":28,"analysis":33},1021967,"额定电压为35kV的系统中，电气设备允许最高工作电压（即设备的额定电压）为（ ）。",[228,230,232,234],{"key":20,"text":229,"correct":22},"35kV；",{"key":24,"text":231,"correct":22},"38.5kV；",{"key":28,"text":233,"correct":26},"40.5kV；",{"key":31,"text":235,"correct":22},"42kV。",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":31,"analysis":33},1021968,"额定电压为11OkV的系统中，电气设备允许最高工作电压（即设备的额定电压）为（）。",[240,242,244,246],{"key":20,"text":241,"correct":22},"11OkV；",{"key":24,"text":243,"correct":22},"115kV；",{"key":28,"text":245,"correct":22},"121kV；",{"key":31,"text":247,"correct":26},"126kV。",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":24,"analysis":33},1021969,"选用的电器额定电流不得低于所在回路各种可能运行方式下的持续工作电流，即IN≥I g,则发电机回路电流按（）选择。",[252,254,256,258],{"key":20,"text":253,"correct":22},"发电机铭牌标注的额定电流；",{"key":24,"text":255,"correct":26},"1.05倍发电机铭牌标注的额定电流；",{"key":28,"text":257,"correct":22},"1.1倍发电机铭牌标注的额定电流；",{"key":31,"text":259,"correct":22},"1.2倍发电机铭牌标注的额定电流。",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":20,"analysis":33},1021970,"选用的电器额定电流不得低于所在回路各种可能运行方式下的持续工作电流，即IN≥I g则带电抗器出线回路电流按（）选择。",[264,266,268,270],{"key":20,"text":265,"correct":26},"电抗器額定电流；",{"key":24,"text":267,"correct":22},"1.05倍电抗器額定电流；",{"key":28,"text":269,"correct":22},"1.1倍电抗器額定电流；",{"key":31,"text":271,"correct":22},"1.2倍电抗器額定电流。",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":28,"analysis":33},1021971,"验算电器动稳定、热稳定以及电器开断电流所用的短路电流，应按工程的规划容量计算，电力系统的远景发展规划容量宜按（）考虑。",[276,278,280,282],{"key":20,"text":277,"correct":22},"3~5年；",{"key":24,"text":279,"correct":22},"4~8年；",{"key":28,"text":281,"correct":26},"5~10年；",{"key":31,"text":283,"correct":22},"8~15年。",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":28,"analysis":33},1021972,"对带电抗器的6~1OkV出线回路，按电抗器前短路计算的设备为（）。",[288,290,292,294],{"key":20,"text":289,"correct":22},"6~1OkV电抗器前的断路器；",{"key":24,"text":291,"correct":22},"6~1OkV电抗器前的母线隔离开关；",{"key":28,"text":293,"correct":26},"6~1OkV母线隔离开关前的穿墙套管；",{"key":31,"text":295,"correct":22},"6~1OkV电抗器前的支柱绝缘子。",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":24,"analysis":33},1021973,"电压为110kV的电器和金具，在（）倍最髙工作相电压下，晴天夜晚不应出现可见电晕。",[300,302,304,306],{"key":20,"text":301,"correct":22},"1.05；",{"key":24,"text":303,"correct":26},"1.1；",{"key":28,"text":305,"correct":22},"1.2；",{"key":31,"text":307,"correct":22},"1.3。",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":28,"analysis":33},1021974,"下面所列绝缘子的安全系数有误的是（）。",[312,314,316,318],{"key":20,"text":313,"correct":22},"套管、支持绝缘子：荷载长期作用时为2.5，荷载短期作用时为1.67；",{"key":24,"text":315,"correct":22},"悬式绝缘子：荷载长期作用时为4,荷载扭期作用时为2.5；",{"key":28,"text":317,"correct":26},"套管、支持绝缘子的金具：荷载长期作用时为4，荷载短期作用时为2.5；",{"key":31,"text":319,"correct":22},"悬式绝缘子的金具：荷载长期作用时为4，荷载短期作用时为2.5。",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":28,"analysis":33},1021975,"普通髙压电器在环境最髙温度为+40℃时，允许按额定电流长期工作。当电器安装点的环境温度高于+40℃（但不髙于+60℃）时，每增高1℃，建议额定电流按（）数值减少。",[324,326,328,330],{"key":20,"text":325,"correct":22},"1.2%；",{"key":24,"text":327,"correct":22},"1.5%,",{"key":28,"text":329,"correct":26},"1.8%；",{"key":31,"text":331,"correct":22},"2.0%。",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":24,"analysis":33},1021976,"普通高压电器在环境最高温度为+40℃时，允许按额定电流长期工作，当电器安装点的环境温度低于+40°C时，每降低1℃,建议额定电流按（）增加.",[336,338,340,342],{"key":20,"text":337,"correct":22},"O.4%,",{"key":24,"text":339,"correct":26},"0.5%；",{"key":28,"text":341,"correct":22},"0.6%；",{"key":31,"text":343,"correct":22},"0.7%。",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":28,"analysis":33},1021977,"以下电压互感器的变比中，适用于发电厂6kV厂用电母线的是（）。",[348,349,350,351],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":28,"analysis":33},1021978,"对限流电抗器的电抗百分值的选择后，还应进行一些校验，以下说法正确的是（）。",[356,358,360,362],{"key":20,"text":357,"correct":22},"应校验母线分段电抗器当一側母线短路时另一侧母线的剩余电压；",{"key":24,"text":359,"correct":22},"不必校验分裂电抗器两臂同时流过反向短路电流时的动稳定；",{"key":28,"text":361,"correct":26},"应校验正常工作时普通电抗器的电压损失；",{"key":31,"text":363,"correct":22},"应校检出线电抗器后短路时的母线剩余电压。",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":24,"analysis":33},1021979,"当断路器两端为互不联系的电源时，断路器同极断口间的泄漏比距应取对地的（）。",[368,370,372,374],{"key":20,"text":369,"correct":22},"1.0倍；",{"key":24,"text":371,"correct":26},"1.5倍；",{"key":28,"text":373,"correct":22},"1.7倍；",{"key":31,"text":375,"correct":22},"1.9倍。",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":28,"analysis":33},1021980,"选择户外髙压断路器时必须校验的环境条件是（）。",[380,382,384,386],{"key":20,"text":381,"correct":22},"环境温度、相对湿度、污秽、地震烈庋；",{"key":24,"text":383,"correct":22},"环境温度、相对湿度、日温差、地震烈度；",{"key":28,"text":385,"correct":26},"环堍温度、最大风速、污秽、地震烈度；",{"key":31,"text":387,"correct":22},"日温差、相对湿度、最大风速、污秽。",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":28,"analysis":33},1021981,"断路器的额定关合电流满足（）。",[392,394,396,398],{"key":20,"text":393,"correct":22},"不小于短路电流有效值即可；",{"key":24,"text":395,"correct":22},"不大于短路电流有效值即可；",{"key":28,"text":397,"correct":26},"不小于短路电流冲击伹即可；",{"key":31,"text":399,"correct":22},"不大于短路电流冲击值即可。",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":31,"analysis":33},1021982,"发电机转子应进行超速试验，超速值为（）倍的额定转速。 A.1.05； B.1.1； C1.15； D.1.2。",[404,405,406,407],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":20,"analysis":33},1021983,"在不需要进行绝缘配合计算时，选择金属氧化物避雷器应校验的项目是（）。",[412,414,416,418],{"key":20,"text":413,"correct":26},"避雷器的持续工作电压；",{"key":24,"text":415,"correct":22},"避雷器的額定电压；",{"key":28,"text":417,"correct":22},"避雷器的冲击放电电压；",{"key":31,"text":419,"correct":22},"避雷器的通流容量。",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":28,"analysis":33},1021984,"220kV的耐张绝缘子串应预留的零值绝缘子片数为（）。",[424,426,428,430],{"key":20,"text":425,"correct":22},"0；",{"key":24,"text":427,"correct":22},"1；",{"key":28,"text":429,"correct":26},"2；",{"key":31,"text":431,"correct":22},"3。",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":24,"analysis":33},1021985,"在校验35kV及以上水平安装的支柱绝缘子的机械强度时，不需计及的项目是（）。",[436,438,440,442],{"key":20,"text":437,"correct":22},"绝缘子自重；",{"key":24,"text":439,"correct":26},"风速；",{"key":28,"text":441,"correct":22},"母线重量；",{"key":31,"text":443,"correct":22},"短路电动力。",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":31,"analysis":33},1021986,"隔离开关采用软导线引下连接时，其接线端机械荷载不需计及（）。",[448,450,452,454],{"key":20,"text":449,"correct":22},"引下线的张力；",{"key":24,"text":451,"correct":22},"风力；",{"key":28,"text":453,"correct":22},"冰雪；",{"key":31,"text":443,"correct":26},{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":20,"analysis":33},1021987,"正常运行条件下，GIS外壳上的感应电压不应超过（）。",[459,461,463,465],{"key":20,"text":460,"correct":26},"24V；",{"key":24,"text":462,"correct":22},"36V；",{"key":28,"text":464,"correct":22},"60V；",{"key":31,"text":466,"correct":22},"100V。",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":24,"analysis":33},1021988,"500kV支柱绝缘子的干弧距离不应小于（）。",[471,473,475,477],{"key":20,"text":472,"correct":22},"2500mm；",{"key":24,"text":474,"correct":26},"3800mm；",{"key":28,"text":476,"correct":22},"4300mm；",{"key":31,"text":478,"correct":22},"4550mm,",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":31,"analysis":33},1021989,"GW10-330型母线隔离开关动、静触头之间的最小电气距离不应小于（）。",[483,484,486,488],{"key":20,"text":472,"correct":22},{"key":24,"text":485,"correct":22},"2600mm；",{"key":28,"text":487,"correct":22},"2800mm；",{"key":31,"text":489,"correct":26},"3250mm。",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":28,"analysis":33},1021990,"对220kV及以下悬式绝缘子型式及每串片数的选择，以下说法错误的是（）。",[494,496,498,500],{"key":20,"text":495,"correct":22},"应按額定电压和爬电比距选择；",{"key":24,"text":497,"correct":22},"应按内过电压倍数和绝缘子串的工頻湿闪电压选择；",{"key":28,"text":499,"correct":26},"应按避雷器的操作过电压保护水平和绝缘子串正极性操作沖击50%放电电压选择；",{"key":31,"text":501,"correct":22},"应按雷电过电压选择。",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":20,"analysis":33},1021991,"SF6全封闭组合电器内，各元件应分成若干气隔。气隔中气体系统的压力，除（）外，宜采用相同气压。",[506,508,510,512],{"key":20,"text":507,"correct":26},"断路器；",{"key":24,"text":509,"correct":22},"隔离开关；",{"key":28,"text":511,"correct":22},"电流互感器；",{"key":31,"text":513,"correct":22},"避雷器。",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":24,"analysis":33},1021992,"可以兼作并联电容器组的泄能设备的是（）。",[518,520,522,524],{"key":20,"text":519,"correct":22},"电容式电压互感器；",{"key":24,"text":521,"correct":26},"电磁式电压互感器；",{"key":28,"text":523,"correct":22},"瓷绝缘结构电流互感器；",{"key":31,"text":525,"correct":22},"树脂浇注绝缘结构电流互感器。",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":28,"analysis":33},1021993,"为尽量节省占地，220kV悬吊管母配电装置的母线隔离开关应采用（）。",[530,532,534,536],{"key":20,"text":531,"correct":22},"GW4型",{"key":24,"text":533,"correct":22},"GW7型；",{"key":28,"text":535,"correct":26},"GW1O型；",{"key":31,"text":537,"correct":22},"GW11型。",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":540,"answer":28,"analysis":33},1021994,[541,542,543,544],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":24,"analysis":33},1021995,"地震烈度为8度时，电器需承受的地震力地面水平加速度值和地面垂直加速度值应分别为（）。",[549,551,553,555],{"key":20,"text":550,"correct":22},"0.15g，0.1g",{"key":24,"text":552,"correct":26},"0.2g,0.1g；",{"key":28,"text":554,"correct":22},"0.2g,0.15g；",{"key":31,"text":556,"correct":22},"0.4g,0.2g。",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":31,"analysis":33},1021996,"对两班制调峰运行的电机，转子在它的使用寿命期限内，在机械上应能承受的启动次数应为（）。",[561,563,565,567],{"key":20,"text":562,"correct":22},"不少于3000次；",{"key":24,"text":564,"correct":22},"不少于5000次；",{"key":28,"text":566,"correct":22},"不少于8000次；",{"key":31,"text":568,"correct":26},"不少于10000次。",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":31,"analysis":33},1021997,"1台35kV、2000kV A、35±2X2.5%\u002F0.4kV的配电变压器，其低压侧中性点电流互感器的一次额定电流一般取（）。",[573,575,577,578],{"key":20,"text":574,"correct":22},"4000A；",{"key":24,"text":576,"correct":22},"3000A；",{"key":28,"text":185,"correct":22},{"key":31,"text":579,"correct":26},"1000A。",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":28,"analysis":33},1021998,"断路器的额定峰值耐受电流是说明断路器（）。",[584,586,588,590],{"key":20,"text":585,"correct":22},"开断短路电流的能力；",{"key":24,"text":587,"correct":22},"承受短路电流热效应的能力；",{"key":28,"text":589,"correct":26},"承受短路电流电动力作用的能力；",{"key":31,"text":591,"correct":22},"关合短路不至于发生触头熔焊的能力。",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":28,"analysis":33},1021999,"普通高压电器一般在环境最低温度为（）时正常运行。",[596,598,600,602],{"key":20,"text":597,"correct":22},"-20℃；",{"key":24,"text":599,"correct":22},"-25℃；",{"key":28,"text":601,"correct":26},"-30°C；",{"key":31,"text":603,"correct":22},"—35℃。",[605,608,611,614,617,620],{"id":15,"name":606,"category":7,"favorite":607},"领导干部任职前廉政法规知识测试题",92,{"id":609,"name":610,"category":7,"favorite":15},595,"建筑结构与设备",{"id":612,"name":613,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":615,"name":616,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":618,"name":619,"category":7,"favorite":8},534,"BIM工程师",{"id":621,"name":619,"category":7,"favorite":8},535]